| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 LAccepted-Finance | L1 | Accepted-Finance L1 Bidder | |
| 2 | L2₹15.3 L+₹16,676.50 (1.10%)Accepted-Finance | L2 | Accepted-Finance L2 Bidder | |
| 3 | Rejected-Technical | - | Rejected-Technical TECHNICALLY DISQUALIFIED |
Tender Value
₹15.6 L
EMD Value
₹20,000
Closing Date
13 Dec 2021, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE OMC IV CTPS PTPP PARICHHA
OFFICE OF SE OMC IV CTPS PTPP PARICHHA
Routine and Breakdown Maintenance of lighting illumination system and HT LT cables systems of main plant service building and BOP area including 250 MW Chimney of 250 MW of Unit 5 6 PTPP Parichha Jhansi and switching ON OFF of lighting fixture
2021_RVUNL_643845_1
T-09/OMC-IV/EMD-II/PTPP/2021 22
Open Tender
Electrical Works
Fixed-rate
365 days
PARICHHA
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
DY CAO CFA AND BO PTPP
₹20,000
18 Dec 2021
16 Nov 2021
13 Dec 2021
16 Nov 2021
13 Dec 2021
16 Nov 2021
120 days
Amount
Routine and Breakdown Maintenance of lighting/illumination systems of main plant, service building and BOP area including 250 MW Chimney of 2x250 MW, of Unit 5&6 PTEP, Parichha, Jhansi and switching ON/OFF of lighting fixtures and panels as per scope of work Part-A.1
Routine maintenance and up keeping of power cables, control cables and associated cable trays as per scope of work Part-A (I) from Sl. No. 1 to 3 and Part-A (II) from Sl. No. 1 to 9.
Salvaging/laying of 1CX800/3CX185 HT UE XLPE Cable
Salvaging/laying of 1CX800 /3CX240/3CX300/1CX630 LT Cable
Salvaging/laying of 3CX150/3CX185/1CX400 LT Cable
Salvaging/laying of 3CX120/1CX300/2CX120 LT Cable
Salvaging/laying of 3CX95/3CX70/1CX185/1CX150 LT Cable
Salvaging/laying of 1CX120/3CX50 LT Cable
Salvaging/layingCABLE SIZE BELOW 35 MM2 (1CX35,3CX35, 3.5CX35)
Salvaging/layingCABLE SIZE BETWEEN 35 MM2 TO 50 MM2(1CX50, 3CX50,3.5CX50)
end termination of 1CX800/3CX185 HT UE XLPE Cable
end termination of 1CX800 /3CX240/3CX300/1CX630 LT Cable
end termination of 3CX150/3CX185/1CX400 LT Cable
end termination of 3CX120/1CX300/2CX120 LT Cable
end termination of 3CX95/3CX70/1CX185/1CX150 LT Cable
end termination of 1CX120/3CX50 LT Cable
end terminationCABLE SIZE BELOW 35 MM2 (1CX35,3CX35, 3.5CX35)
end terminationCABLE SIZE BETWEEN 35 MM2 TO 50 MM2(1CX50, 3CX50,3.5CX50)
Straight through jointing of 1CX800/3CX185 HT UE XLPE Cable
Straight through jointing of 1CX800 /3CX240/3CX300/1CX630 LT Cable
Straight through jointing of 3CX150/3CX185/1CX400 LT Cable
Straight through jointing of 3CX120/1CX300/2CX120 LT Cable
Straight through jointing of 3CX95/3CX70/1CX185/1CX150 LT Cable
Straight through jointing of 1CX120/3CX50 LT Cable
Straight through jointingCABLE SIZE BELOW 35 MM2 (1CX35,3CX35, 3.5CX35)
Straight through jointingCABLE SIZE BETWEEN 35 MM2 TO 50 MM2(1CX50, 3CX50,3.5CX50)
Relugging only of 1CX800/3CX185 HT UE XLPE Cable
Relugging only of 1CX800 /3CX240/3CX300/1CX630 LT Cable
Relugging only of 3CX150/3CX185/1CX400 LT Cable
Relugging only of 3CX120/1CX300/2CX120 LT Cable
Relugging only of 3CX95/3CX70/1CX185/1CX150 LT Cable
Relugging only of 1CX120/3CX50 LT Cable
Relugging onlyCABLE SIZE BELOW 35 MM2 (1CX35,3CX35, 3.5CX35)
Relugging onlyCABLE SIZE BETWEEN 35 MM2 TO 50 MM2(1CX50, 3CX50,3.5CX50)
Laying of cables of all sizes power cables covered in Part-A above including end termination.
Laying of all type of control cables etc. including end termination. (as per scope of work)
Fabrication and fixing of cable racks & other M.S. structures. (as per scope of work)
Laying of cable trays of different type alongwith Accessories. (as per scope of work) width upto 300 mm.
Laying of cable trays of different type alongwith Accessories. (as per scope of work) width more than 300 mm.
Erection of various type of TPN switch/starter upto 63 A rating. (as per scope of work)
Erection of various type of TPN switch/starter above 63 A rating. (as per scope of work)
Cleaning of cable tray by removal of tray cover during O/H or S/D for attending cable fault or removal of accumulated coal dust and cleaning of tray and reffixing. (as per scope of work)
Providing new tray cover at different location and clamping thereof as per size.(as per scope of work)
Digging of earth for locating and attending the faulty portion Of cable and refilling in the same manner after attending the fault. (as per scope of work)
Providing cable markers as danger board at every 10 metre to Avoid damage to under ground cable by grouting 2 Ft. long angle Pieces wherever required. (as per scope of work)
Removal & refixing of chequer plate or grid or fire proof board for attending cable fault on beneath the racks or for maintenance purpose. (as per scope of work)
Removal of cable from Trench/Tunnel & cartage/storage at site store by proper re-rolling.Power cables less than 50 sqmm.
Removal of cable from Trench/Tunnel & cartage/storage at site store by proper re-rolling. Control cables of all types. (as per scope of work)
Writing of nomenclature in the size of 1-1/2 inch as and when required anywhere on the panel board. (as per scope of work)
Proper filling of holes/gaps in cable gallery area with Plastic of Paris (POP) to avoid air/dust ingress in this area
Painting of trays/plates or other M.S. structures with red oxide primer with material. (as per scope of work)
Painting of trays/plates or other M.S. structures with synthetic enamel of reputed brands. Asian paints/Berger /Nerolac with material. (as per scope of work)
Checking & Cleaning of cables in open cable tray during O/H or S/D for locating/attending cable fault or removal of accumulated coal dust and cleaning of tray and reffixing. (as per scope of work)
Removing dry/oil bound distemper, water proofing cement paint, and making the wall surface smooth by using Sand Paper/Emery Paper, also remove/clear scratches etc by other means as per scope of work Sr.No. 18 of Part-B
Applying two coatings of distempering on wall/roofs after making surface clean and clear as per scope of work Sr.No. 19 of Part-B
Cleaning of cable galleries of 140Mx9.0M size floors at zero meter & ten meter elevation and out side area of DG sets building and Weekly cleaning of cable gallery roofs of 140Mx9.0M and all four side walls with doors of cable galleries at zero meter & ten meter elevation as per scope of work Part-C(I)-1( a to e) and C(I)-2( a to c).
“Routine cleaning of floors and collection and proper disposal of garbage of .4KV LT panels of main plant and BOP areas of unit # 5&6 , 2x250 MW And Cleaning of roofs , walls and windows of 0.4KV LT panels of main plant and BOP areas of unit # 5&6 , 2x250 MW. All the spider nets etc. shall be disposed off.” As per scope of work Part C(II) Sr. No. 1 to 7.
KRISHNA ENTERPRISES
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .