Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹89.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹1.0 Cr+₹14.3 L (16.0%)Rejected-Finance PLOT NO 21 5 6 ROAD NO 11 BAIGANWADI GOVANDI MUMBAI 400 043 | MUMBAI | MUMBAI | MAHARASHTRA | 400043 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹1.1 Cr+₹25.4 L (28.6%)Rejected-Finance ROMA BANJARA TANDA CHS BUILDING NO 1 ROOM NO 506 MANKHURD W MUMBAI 400 043 | MUMBAI | MUMBAI | MAHARASHTRA | 400043 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹1.2 Cr+₹34.9 L (39.2%)Rejected-Finance 506 5TH FLOOR GRANDE EDIFICE AKURLI ROAD OFF W E HIGHWAY KANDIVALI EAST 400101 MUMBAI MAHARASHTRA 400101 INDIA UDYAM MH 18 0005535 27AAGFE2360M1ZA R M MII STATUS AS VERIFIED | MUMBAI SUBURBAN | MAHARASHTRA | 400101 | L4 | Rejected-Finance Being L4 | |
| 5 | Rejected-Technical F 8 7 SECTOR 5 CBD BELAPUR NAVI MUMBAI | - | Rejected-Technical Not meeting NIT Criteria |
Tender Value
₹1.1 Cr
EMD Value
₹2.1 L
Closing Date
16 Feb 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Engineer, CED, BARC
Civil Engineering Division, BARC, Mumbai
Replacement of Old Roofing sheet with double skin insulated Roofing system and re-grading of existing truss profile of Light Motor Vehicle -LMV Garage, TMS, North site, BARC, Trombay, Mumbai.
2022_BARC_668956_1
BARC/CED/ET/56/2021-2022 Dated 18.01.2022
Open Tender
Civil Works
Item Rate
240 days
LMV Garage, TMS, North site, BARC, Trombay, Mumbai
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹2.1 L
4 Aug 2022
21 Jan 2022
18 Feb 2022
21 Jan 2022
16 Feb 2022
21 Jan 2022
180 days
Amount
Dismantling plain cement concrete manually / by mechanical means carefully without damaging adjacent structures including disposal of debris within 200 m lead as per direction of Engineer-in-charge.
Dismantling of RCC works including Cutting and stacking of steel reinforcement bars and disposal of unserviceable materials within 100 m lead as per direction of Engineer-in-charge.
Dismantling brick work in Cement mortar carefully without damaging adjacent structures including stacking of materials and dispoal of unserviceable materials within 100 m lead as per direction of Engineer-in-charge.
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismantling and stacking within 100 m lead.
Dismantling roofing including ridges, valleys and gutter etc and stacking the material within 50 m lead. G.S Sheet / FRP Sheet / AC Sheet.
Lead charges for lead Exceeding 2 KM but not exceeding 3 KM, by mechanical transport including loading, unloading, stacking / levelling etc. Debris Beyond 2 Km but up to and including 3 km. Note: The rates in respect of this item is applicable for NET Quantities arrived at after making deduction for voids @ 30% from corresponding TRUCK Measurement.
Providing and constructing Brickwork in cement mortar 1:4 using crushed sand with Flyash/ Flyash Lime bricks with minimum 70 kg/ sq.cm strength of approved make and size in super structure up to and including Floor II Level including, scaffolding, raking out joints, curing, cleaning complete all as per specifications and drawings.
Providing 15 mm thick plastering using Ready mix internal plastering compound of approved make for internal faces of brickwork / concrete surfaces including preparation of the surface, curing, cleaning, scaffolding complete all as per specifications and as directed at site by the Engineer-in-charge.
Providing 20 mm thick plastering using Ready mix external plastering compound of approved make for external faces of brickwork / concrete surfaces including preparation of the surface, curing, cleaning scaffolding up to 10 metres height complete.all as per specifications including forming drip moulds wherever necessary and as directed by the Engineer-in-charge.
Providing Structural steel work in M.S Plain Plates and chequrred Plates for Embedded Parts, Trench Covers, Connection plates etc.including cutting, hoisting, fixing in position and applying a priming coat of approved zinc chromate steel primer etc.including cost of structural steel Plates, welding all labour charges etc. complete as per drawings and specifications. Using materials confirming to IS 2062. All test reports to be provided along with the supply of the materials.
Providing Structural steel work using angles, channels, joists and other sections, welded and / or bolted in built up sections for trusses , structural steel floors, frame works, monorails and other structures including supplying, cutting, welding, fabricating, hoisting, fixing in position, applying a priming coat of approved steel primer etc. complete all as per specifications, drawings and as directed by the Engineer in charge. Up to and including 300 mm Joists, 350 mm channels, and below sections Using materials confirming to IS 2062. All test reports to be provided along with the supply of the materials.
Providing, supplying, cutting, welding, fabricating, hoisting and fixing in position structural steel members like trusses, purlins, posts etc. using MS hollow / circular / square / rectangular tubular sections including appling a coat of Zinc chromate primer of approved make all as per specifications, drawings and as directed by the Engineer in charge. Notes for Item No. 10, 11 & 12: 1. The contractor shall supply documentary evidence of purchase of steel, Test certificate from approved manufacturers. 2. Welding weights, connections, bolts and nuts shall not be measured for payment but the cost of which shall be deemed to have been included in the rates. 3. Welding Electrodes of specified suitable grade only shall be used. 4. Holes to be drilled only by Drilling machines and gas cutting of holes are not permitted. 5. Rate inclusive of all consumables like GAS, welding electrodes and tools and tackles etc.
Supply and installation of Built at site double skin insulated Roofing systems comprising of the following layers : Inner/Liner sheets : The base metal shall be hot dip galvanised steel with minimum 250 MPa with 120gsm of zinc coating mass as per IS 277. The sheets shall be permanently colour coated in a continuous coating line with pre-treatment / conversion by dip process, applied with special flexible primer (PU primer)(non epoxy) on both surfaces (each of avg. DFT 5 micron), followed by a finish coat of of avg. DFT 20 microns using RMP paint (Special Polyester Paint), on the exposed surface and special polyester paint in mill standard grey shade to an avg. DFT 5 micron on the unexposed surface. The total coated thickness of the metal, inclusive of galvanising , chemical treatment, primer and finish coats shall be 0.50 mm. ( Tolerances +/- 5% as per IS 513 (ISO 16162). Inner sheets shall be factory finish sheets . Profile used shall be of 32-36mm depth, pitch shall be 230 - 270 mm c/c , overall width 1060-1080 mm (corresponding effective width as per profile manufacturer details) with stiffening ribs on each pan of the sheets. The sheets shall be fixed with SDST screws with EPDM washers conforming to AS 3566 class 3 specifications. The screws shall be fixed on valley of the sheets . At interim level it will be spaced at 500mm c/c and at eaves level, end laps it will be spaced at every 250mm c/c. The end laps shall be minimum 200mm and shall be sealed with neutral curing sealent or rubber sealent. Sub girt : Suitable spacer as per design shall be fixed by SDST screws through the inner sheet to the underlying purlin.Galvanised (hot dip 120 gsm as per IS 277) sub girt in shape of Z or HAT section shall be used to support outer sheets. The thickness shall be minimum 1.5mm. INSULATION : Mineral wool conforming to IS 8183 of min. density 48 Kg. per cu.m. built up in two layers of 50 mm each (laid perpendicular to each other) to make 100 mm total insulation thickness. VAPOUR CONTROL BARRIER below OUTER SHEET : The vapour control barrier below the outer sheet shall comprise of a polyethylene bubble pack between two aluminium foils of 9 microns on either side, making up a composite thickness of 4 ± 0.20 mm. Outer sheets/Weathering Sheets : Base Metal shall be Aluminium Magnesium Alloy i.e 5754 in minimum 0.70mm thick , Ultimate tensile strength: minimum 280 N/mm2, 0.2% Proof Stress :minimum 240 N/mm2 The paint systems shall be PVdF paint system, with PVdF compatible primer of 5 micron on each surface, 20 micron avg DFT PVdF paint on exposed surface and min. 7 micron DFT PVdF compatible back coat on unexposed surface .The colour coating shall be meet the requirements of AS 2728 class 3. The profile shall have width of 400 – 560mm with depth of 45-65mm and shall be fixed with Halters/Aluminium clip for zipped lock/ machine seaming and acetalyte bracket for snap lock systems. The quoted rate shall include all cost towards material,spacers,clips,accessories,consumables,sealant tape,sealants, loading, unloading, fixing , wastages, freight, entry permit etc no additional cost whatsoever nature shall be charged or claimed at later date for the said item.(Note: Contractor to arrange for witnessing of third party test and pre-dispatch inspections.Inspection shall also be arranged for the painting process.All such inspection and testing costs shall be included in the quoted rate. All sheets shall have manufacturers name and Grade of roofing sheet printed at reqular intervals. Completing the work with all necessary flashing of same material, colour and thickness as for outer sheet for closures, trims, corners, ridges, aprons, caps etc. as required for completion of the work as per approved drawings(Note:The quoted rate shall include the cost of all materials mentioned in the item description including fixtures,fittings,freight ,transportation,entry permit, unloading/loading,fixing at roof level, wastages(if any),all accessories,butyl tape,tools and tackles,etc complete). Note : Ridge & Flashing will be measured as per actuals under the relevant items.
Ridges/Flashings irrespective of girth in same material, thickness and colour as Inner sheets as directed by the Engineer-in Charge
Ridges/Flashings irrespective of girth in same material , thickness & Colour as Outer sheets as Directed by the Engineer-in Charge
Providing and Painting two coats of synthetic enamel paint on Steel Surfaces of approved brand and manufacture to give an even shade without primer coat.including preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in-charge.
Providing and fixing Hilti make HST3-R M16x145 45/25 or approved equivalent quality/ product meeting technical parameters, expansion hold fasteners in CC / RCC surface backing including drilling necessary holes and the cost of bolt etc complete as per direction of Engineer-in-charge and finished smooth.
Providing and fixing double tubular scaffolding system using H- frames with cup lock type on the exterior side upto seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre horizontal and vertical tubes joining with cup and lock system with M.S. tubes, M.S. tube challies, M.S clamps and M.S staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and as approved by the Engineer -in - charge. The elevational area of the scaffolding shall be measured for payment purposes. The payment shall be made once irrespective of duration of scaffolding.
Providing SFMC Micro concrete for strengthening of structural members including mixing, pouring, curing as per manufacturer specifications and as directed by the Engineer-in-charge. Using 100% SFMC
Providing structural repairs in old damaged concrete structures / surfaces with approved Polymer with following operations 1) Removal of loose/Spalled or damaged concrete by chipping and cleaning the concrete surface and reinforcement steel with wire brush and with water 2) Cleaning the re bars with Acetone for complete rust removal and washing with water to make the surface clean. 3) Applying protective coat / bond coat using polymer and cement in the proportion of 1; 1.5 (1 part of polymer and 1.5 parts of cement in synthetic enamal paint like consistancy with brush 4) Reinstate the area with polymer modified mortar in layers of maximum 20 mm with the proportion of Cement 50 Kg : washed and dried river sand 87.50 kg ; silica sand 37.50 Kg. mixed with 10 litres of Polymer (or 1 Kg cement : 1.75 kg washed and dried river sand ; 0.75 Kg silica sand : 200 ml polymer) 5) If thickness of repair exceeds 20mm , after every 20 mm thick repair, bond coat as per 2 above to be applied and further thick of repair to be continued for each layer. This work is inclusive of all materials, labour, complete all as directed at site using approved polymer suitable for structural repair shall be used). Note: Scaffolding will be paid separately under relevant item.
Disposal of diamantled structural steel /aluminium of all sections, plates etc by mechanical means, including loading, transporting, unloading to approved location/TVS dumping ground or as directed by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Supplying man power along with necessary pans, spades, shovels pickaxe, punjas, ropes, small special spade, raincoats, safety shoes, etc. minimum two number of labour per day upto maximum any number of labour as and when decided by Project Engineer to work for eight hours per day or monsoon period to carry out the cleaning of choked drains grating grills/hume pipes /footpath by removing the dry leaves, silt etc. and also carry out seasonable departmental work allotted by Project Engineer from time to time.
shoiab construction
SUNIL CONSTRUCTION
ENTERPRISING ENTERPRISE LLP
stage.html
html • 0.05 MB
techsummary_704046.pdf
PDF • 0.37 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_704046.pdf
PDF • 0.34 MB
WOVikasConstruction.pdf
PDF • 6.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .