Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.4 LAccepted-AOC D 154 ADARSH NAGAR JABALPUR MP 482001 | JABALPUR | MADHYA PRADESH | 482001 | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹42.5 L+₹2.7 L (6.79%)Rejected-Finance 14 L N Y MARKET RANJHI JABALPUR MP 482005 | JABALPUR | MADHYA PRADESH | 482005 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹44.4 L+₹4.6 L (11.5%)Rejected-Finance HDLX 31 JASUJA CITY JABALPUR MP 482003 | JABALPUR | MADHYA PRADESH | 482003 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹44.6 L+₹4.8 L (12.0%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹45.8 L+₹6.0 L (15.2%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
12 Nov 2021, 6:00 pmClosed
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
WATER PROOFING TREATMENT, REPAIRS TO LEAKAGE, SEEPAGE IN ROOFS/ WALLS AND ALLIED WORKS UNDER GE (WEST) JABALPUR
2021_MES_481966_1
8385/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Jabalpur
As per tender docus
5 documents required · 5 mandatory
₹500
GE (West) Jabalpur
₹96,000
20 Nov 2021
14 Oct 2021
15 Nov 2021
14 Oct 2021
12 Nov 2021
29 Oct 2021
15 Oct 2021 - 27 Oct 2021
Amount
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for including reinforcement cut as required to facilliate demolition complete all as specified and directed.
M & L for RCC (1:2:4) nominal Mix using 20mm graded aggregate as in chajjas,parapet facia etc complete all as specified and as directed.
M & L for RCC (1:2:4) nominal Mix using 20mm graded aggregate as in slab supported on walls,beam and column in floors, roof, landing, balconies,canopies, deck slabs and in shelves and the like complete all as specified and as directed.
Fair finish form work to sides and soffits of floor or roof beams, beam hunching, girders, bressummers, lintels, cantilevers, shelves including sup-ports, overhangs, etc. also splays between floors and beams etc. complete all as specified and directed.
Formwork to chajjas, troughs and similar items including edges fair finished complete all as specified and directed.
S&F Mild steel TMT bars 6mm to 8mm dia and cut to length bent to shape required, including cranking, bending and binding as in stirrups, spacers and binders etc. with MS wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming complete all as specified and directed.
Demolition of cement concrete of any description and in any position complete all as specified and directed.
M&L for 25MM thick cement concret Type B-1 1:2:4 (Using 20mm graded aggregate ) as in flooring etc all as specified and directed.
M&L for 15MM thick rendering in CM (1:3) on brick or concrete surfaces in two layers mixed with water proofing compound @ 3% by weight of cement in top 5mm thick, finishing the surfaces with even and smooth with using extra cement complete all as specified and directed. ( Note:- WPC measured separately) complete all as specified and directed.
Supply only integral water proofing compound
M&L for Bitumen blown any grade , applied hot, two coats to concrete surfaces at the rate of 1.5Kg /sqm per coat. Including polythene film, black , 50 micron laid in floors complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as complete all as specified and directed.
M&L for cement concrete 1:1.5:3 type A-0 using 12.5 mm graded stone aggregate as in roof kerbs PCC as in kerbs/cover fillet complete all as specified and directed.
Material & Labour for repairing sunken floors leakage by taking out existing nahani trap or floor traps carefully by digging out from its position and provision of new PVC (SWR) nahani trap 100mm dia and joining the same to existing waste pipe and ensure leak proof joints including PCC 1:5:10, Type E-2 and making good the adjoining area to match with existing floor tiles etc with PVC NT / FT, CP steel grating 100 mm dia complete all as specified & directed.
M&L for repairing of cracks n.exc 10mm in width including preparation of cracks by removing loose portion of cracks with grinding, dusting with blowers and washing down, applying crack filling material (Dr Fixit, Crack -X paste) in cracks making surface good complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats, wind ties etc. conforming Fe 410 -W (GdeE- 250) qualityA complete all as specified and directed.
M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming Fe 410 -W (GdeE- 250) qualityA complete all as specified and directed.
Dismantling of timber scantlings unframed 40Sq Cm and over in section, in any position complete all as specified and directed.
M&L for Second class hard-wood in scantlings and clean sawn timber framed and fixed complete all as specified and directed.
Dismantling of Asbestos cement (corrugated, semi corrugated,etc) sheets in roof covering complete all as specified and directed.
M&L for 6mm thick non asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc Fixed with L-type or J-type or cranked hook bolts complete all as specified and directed.
M&L for refixing of 6mm thick non asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc Fixed with L-type or J-type or cranked hook bolts complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering incl ridge complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Taking down cement plaster on brick/ stone masonary including raking out joints, hacking for scrubbing down with water etc. complete all as specified and as directed.
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed..
M&L for brick work with sub class ‘B’ brick, straight or curved on plan exc 6 m mean radius built in CM 1:6 complete complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick walls with old size bricks built in cement mortar 1:4 complete all as specified and as directed.
M&L for 5mm thick cement plaster in cement mortar 1:3 as on ceiling, soffits of RCC shelves, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M&L for 15mm thick rendering in cement mortar (1:4) with WPC on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed (WPC shall be measured seperately ) (Rates included for G+2 floors, and no extra payment to be made for the same).
M&L for 15mm thick rendering in cement mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for Preparation of newly plastered surfaces of walls and applying two coats of oil emulsion distemper over a coat of primer complete all as specified.
M&L for Prepration of newly plastered surfaces of ceiling and applying three coat of white wash on ceiling etc all as specified.
M&L for Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer etc complete all as specified and directed.
M&L for preparation of old / decorated surfaces of wall by complete removal of existing treatment, filling crack with pidilite crack filling material and making total surface levelled by applying water proofing putty (Pidilite) and applying two coats of rain coat (Pidilite) over primer (over putty) complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
M&L for suspended false ceiling system using chicago metallic (E grid) exposed supended system, grid section size 600mm X 600mm comprising of GI powder coated Main Runner of dimensions 39 mm X 24mm X 0.8mm thick (thickness comprising of GI/0.4+ PPPCGS/0.3mm & weight of runner 1.35 kg for 3600mm length) Cross Tee of dimensions 29mm X24mmX0.8mm thick and thick wall angle 22.2mmX22.2mmX 0.65 mm thick ( thickness comprising of GI/0.35+ PPPCGS/0.3mm & weight of angle 0.70 kg for 3050mm length) with and including 4mm thick HPSC(High pressure steam cured) pre-primed , self embossed . textured designer board, water resistant termite resistant , fire resistant for insulation and acoustic purpose to be placed in the grid system duly suspended with 4mm dia GI bar hangers fixed with steel dash through fasteners from purlins of the roof with butterfly clips(Wt-0.007 Kg/clip)hold down clips (Wt-0.0035 Kg/clip) with Provn of light fixture complete all as specified and directed. Make :- ARMSTRONG AND EVEREST or other equivalent as approved.
S&F, in repair, stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F in repairs Sheet glass ordinary quality 3 mm thick in square n exc 0.50 Sqm each pane glazing with oil putty, clip in metal frame or wooden beading in wooden frame complete all as specified (Rates in cluded for G+2 floors, and no extra payment to be made for the same).
Supply and fix in repairs sheet glass ordinary quality 4.8 mm thick in square exc 0.50 Sqm each pane glazing with oil putty, clip in metal frame and wooden beading in wooden frame etc complete all as specified.
S&F in repairs 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S&F in repairs 110 mm dia PVC (SWR ) pipes Single socketed in any length with rubber rings joints fixed to walls complete all as specified and as directed.
S&F in repairs 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S&F in repairs 75 mm dia PVC (SWR ) pipes Single socketed in any length with rubber rings ljoits fixed to walls complete all as specified and as directed.
S&F in repairs 110 mm dia PVC (SWR ) bends any radius complete all as specified and as directed.
S&F in repairs 75 mm dia PVC (SWR ) bends any radius complete all as specified and as directed.
S&F in repairs 110 mm dia PVC (SWR ) branch piece,single (single Y) equal or unequal complete all as specified and as directed.
S&F in repairs 75 mm dia PVC (SWR ) branch piece,single (single Y) equal or unequal complete all as specified and as directed.
S&F in repairs 110 mm dia PVC (SWR ) junction,single (single T) equal or unequal complete all as specified and as directed.
S&F in repairs 75 mm dia PVC (SWR ) junction,single (single T) equal or unequal complete all as specified and as directed.
Roughening surfaces of old concrete floor/ terrace by picking incl. taking down existing detiorated / decayed tar felt PCC tiles or any type of treatment including loose surface, scraping with scraper, chiseling, scraping of surface with wire brush or any other method, sweeping clean & washing down with water to remove dust etc. complete all as specified and directed.
Removing building materials to a distance of 100m or under, beyond the lead incl in the rates incl loading, unloading and stacking at the destination complete all as specified and directed.
Material and labour for cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in roof padding 50mm thick in average complete all as specified and directed. .
M&L for 10 mm thick screed bed or bedding layer in CM 1:3 mixed with water proofing compound @ 3 % by weight of cement on concrete roof surface finished fair and even to maintain the proper slope of roof surface etc complete all as specified and directed.
M&L for Providing water proofing treatment over cleaned roof surface with super thermo APP modified water proofing memberane comprising of the following for roofs complete all as specified and directed:- (a) Cleaning of plastered roof surfaces and applying a coat of bitumen primer @ 0.30 kg/Sqm on top of dry surface of finished cement mortar plaster. (b) One coat of hot blown bitumen of grade 85/25 @ 1.2kg /sqm shall be applied over primed surfaces. (c) One layer of APP based polymeric water proofing membrane of weight not less than 3 kg/Sqm consisting 3mm thick reinforced with polyster non wove fabric shall be unrolled surfaces with lap of 100 mm and the over lap shall be sealed by flame. (d) Applying two coats of aluminum paint on top of membrane @ 0.10Kg/Sqm.
M&L for Bitumastic gola, with 80/25 bitumen and coarse sand mixture, 1:3 by weight, 8cmx8cm at the junction of roofing to vertical surfaces complete all as specified and directed.
S&F cement concrete tiles size 25cmx25cmx22mm thick machine cut pressed set jointed and pointed in neat cement slurry with grey cement and pigments in floors and cut and polished fixed over and including 15mm thick screed bed in CM 1:6 etc complete all as specified and directed
Cutting grooves in brick wall,75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
S&F in repairs for steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 15mm bore of pipe complete all as specified and directed.
S&F in repairs steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 20mm bore of pipe complete all as specified and directed.
S&F in repairs steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 25mm bore of pipe complete all as specified and directed.
M&L for disconnecting existing tanks of 250 to 500ltr capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) complete all as specified and directed
M&L for disconnecting existing tanks of 500 to 1000ltr capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) complete all as specified and directed
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid dry or laid dry and pointed complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and directed.
M&L for 75 mm thick plain cement concrete 1:4:8 type D-2 (using 40mm graded stone agg as in sub base finishing the surface even and rough to receive floor finishes complete all as specified and directed.
M&L for 60 mm thick Machine pressed rubber moulded precast concrete interlocking paver block any shape and size with grey cement and pigment, confirming to IS 15658-2006of 60mm thickness M 35 Grade fixed over and including 50mm thick sand coushioning etc complete all as specified and as directed.
M&L for coloured rubber moulded cement concrete chequered tiles 300x300x22 mm thick with cement and coloured pigment, set and jointed in neat cement slurry and pointed in coloured cement to match as in floors fixed over and including 15mm thick screed bed to floor finishes in cm 1:6 etc complete all as specified and directed.
M&L for machine cut kota stone slab flooring 20-25mm thick fixed over and including cement Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed.
M&L for machine cut kota stone slab flooring 20-25mm thick as in riser of steps, skirting, dado and pillar laid over and including 15mm thick cement screed in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed.
Rai Construction Co
ANAMIKA CONSTRUCTION
KRD ASSOCIATE
Deepesh Electricals
M/s Kehar Engineers
Tiki Water proofing Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .