Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹21.5 L+₹80,791.65 (3.90%)Rejected-Finance 67 AASANI BAS PALANA PALANA BIKANER BIKANER RAJASTHAN 334402 UDYAM RJ 08 0063520 | BIKANER | RAJASTHAN | 334402 | L2 | Rejected-Finance Other then lowest | |
| 3 | L3₹21.8 L+₹1.1 L (5.23%)Rejected-Finance | L3 | Rejected-Finance Other then lowest | |
| 4 | L4₹22.0 L+₹1.3 L (6.24%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L4 | Rejected-Finance Other then lowest | |
| 5 | L5₹26.3 L+₹5.6 L (27.3%)Rejected-Finance FLAT NO 330 PKT 1 SECTOR 1 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L5 | Rejected-Finance Other then lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
13 Jul 2021, 6:00 pmClosed
GE (N) DELHI CANTT-10
GE (N) DELHI CANTT-10
REPAIR MAINT OF INTERNAL ELECTRICATION WORK SERVICES INCL REPLACEMENT OF UNSV VARIOUS TYPE OF LIGHT FITTINGS FIXTURES SUBMAIN WIRING DISTRIBUTION BOARDS MCCBs MCBs ETC AT 505 ARMY BASE WORKSHOP AND ENGINEER STORE DEPOT ESD AREA AND REPAIR/MAIN
2021_MES_454020_1
GE/NORTH-14/2021-22
Open Tender
Civil Works
Works
180 days
GE (N) DELHI CANTT-10
as per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (N) DELHI CANTT-10
₹80,000
Yes
26 Jul 2021
23 Jun 2021
15 Jul 2021
23 Jun 2021
13 Jul 2021
7 Jul 2021
Amount
Taking down carefully copper / aluminium point wiring (light / fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing all as specified and directed.
M&L for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for One light / bell / buzzer point controlled by one, one way switch 06 Amps.
All as per srl item No 02 here-in-before but one fan point controlled by one, one way switch 06 Amps.
All as per srl item No 02 here-in-before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch.
All as per srl item No 02 here-in-before but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch.
All as per Serial Item No 02 above but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 1.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
S&F switch piano flush type, 06 Amps, single pole, one way, 230 volts complete
S&F bell push, flush type, 06 Amps, 230 volts with switch frame complete
S&F switch piano flush type, 16 Amps, single pole, one way, 230 volts with switch frame complete
S&F socket outlet 2 in 1, 5 pin, 06 Amps, flush type, 230 volts with socket frame complete
S&F socket outlet 2 in 1, 3 pin, 06 Amps and 3 pin, 16 Amps, flush type, 230 volts with socket frame complete
S&F ding dong bell, AC, 230 volts, single pole complete
S&F ceiling fan regulator, 2 Module stepped type of 0 to 04 rotary steps, electronic, socket type, humfree, AC, 230 volts, 100 watts complete
S&F ceiling rose, 6 Amps, 230 volts, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25mm size complete
Supply and fix lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting including 9W LED bulb complete.
S&F in repair 10/12W LED T5 TL fitting (2 fit) attractive wall mounted type suitable for mirror fittings, all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete
S&F in repair on wall / ceiling LED batten lighting fixture 20 watts LED 5700K (4'), with extruded aluminium heat sink, integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block complete
S&F in repair ultra modern recess mounting 36 Watts, 5700K, 2x2 LED flat panel complete with integrated electronic driver, soft-light and glare free symmetrical illumination, suitable for POP ceilings high brightness SMD LEDs, etc including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block complete
S&F in repair energy saving security light fitting of 70 watts LED pressure die-cast aluminium IP 66 roadway luminaire with high power LED as light source comprising with electronic driver and all accessories pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections and 50 mm bore light grade G. I. tube mounting bracket of 1.5 meter in length, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts & washers complete
Taking down of existing u/s highbay lights and Supply and fixing in repair energy saving flood light 150 watts LED 5700K die-cast aluminium IP 66 flood light with high power LEDs as light source, comprising with electronic driver and all accessories complete, arrangements for mounting of fitting i.e. bracket, clamps, nuts, bolts and washers etc all as per site requirement including connecting up with provision of PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections complete.
Material and labour for sub main wiring with 04 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified & directed, including taking down old sub main wiring.
All as as above but for 02x1.5 Sqmm for phase & neutral and 01x 1.5 Sqmm for continuous earth wire
All as above but 06 Sqmm nominal cross sectional area.
All as above but 10 Sqmm nominal cross sectional area, four single core, with and including continuous earth wire of size 06 Sqmm nominal cross sectional area.
Taking down of existing u/s highbay lights and fixing only LED flood light 100/150 watts and all accessories complete, arrangements for mounting of fitting i.e. bracket, clamps, nuts, bolts and washers etc all as per site requirement including connecting up with provision of PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections complete.
S&F in repair industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 230 volts of 20 Amps, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete
S&F in repair industrial type TPN enclosure with a three pin and neutral and earth plug and socket complete with and including 32 Amps MCB, four pole, AC, 415 volts and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete
S&F in repair industrial type TPN enclosure with a three pin and neutral and earth plug and socket complete with and including 63 Amps MCB, four pole, AC, 415 volts and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete
S&F in repair sheet metal enclosure distribution board, single pole and neutral, AC, 230 volts, 08 way, with 200 Amps rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete
S&F in repair sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volts, 04 ways with 200 Amps rated copper bus bar and metal door with IP 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed and comprising of the following :- (a) MCCB, 125 Amps, 04 pole, AC, 415 Volts,16 KA - 01 No. (b) MCB, SP, AC, 230 volts of 06 to 32 Amps, "C" curve, 10 KA - 12 Nos.
S&F sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volts, 04 ways with 400 Amps rated copper bus bar and metal door with IP 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed and comprising of the following:- (a) MCCB, 250 Amps, 03 pole, AC, 415 Volts, 25 KA - 01 No. (b) MCB, SP, AC, 230 volts of 63 Amps, "C" curve, 10 KA - 12 Nos.
S&F in repair MCB, SP, AC, 230 volts of 06 to 32 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using copper lugs complete
S&F in repair MCB, DP, AC, 230 volts of 40 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using copper lugs complete
S&F in repair MCB, DP, AC, 230 volts of 63 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using copper lugs complete
S&F Ventilating fan wall mounted type of 250 mm sweep, 230 volts, AC, 50 Hz capacity, cutting of hole in wall, making of wooden frome, all arrangements for mounting of fan including making good of disturbed surface etc complete all as directed
S&F in repair MCCB, 63 Amps, 04 pole, AC, 415 Volts of 16 KA breaking capacity complete
S&F in repair MCCB, 100 Amps, 04 pole, AC, 415 Volts of 16 KA breaking capacity complete all as specified & directed.
S&F in repair MCCB, 125 Amps, 04 pole, AC, 415 Volts of 16 KA breaking capacity complete
S&F in repair MCCB, 200 Amps, 04 pole, AC, 415 Volts of 36 KA breaking capacity complete
S&F in repair MCCB, 250 Amps, 04 pole, AC, 415 Volts of 36 KA breaking capacity complete
S&F or passing through pipe, 10 Sqmm, 2 core, 1100 Volts grade, heavy duty, multi-stranded, PVC insulated, aluminium conductor, served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed service cable for service connections from existing LT Panel/Pole to DB/busbar chamber including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete
M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete
Supply and fixing in repair on wall energy saving, eco friendly LED bulk head fitting 10Watt, IP 65surface mounted with ABS body & polycarbonate diffuser, etc and all accessories pre-wired including connecting up including taking down of existing u/s light fitting complete all as directed.
Taking down of exiting u/s security light fitting and supply and fixing energy saving LED security light fitting with lens of 45 watts Versatile pressure die-cast aluminium IP 66 roadway luminaire with high power LED as light source comprising with electronic driver and all accessories pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections and suitable GI tube bracket for mounting of light fitting, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means of suitable flat iron clamps, nuts, bolts and washers etc complete all as specified and directed.
Supply and fixing Ventilating fan wall mounted type of 200 mm sweep, 230 volts, AC, 50 Hz capacity, cutting of hole in wall, making of wooden frome, all arrangements for mounting of fan including making good of disturbed surface etc complete all as directed by Engineer - in - charge.
Sch of Credit- Total contract sum shall be calculated after deduction of Sch of Credit amount Credit amount - Rs. 77125.00
S. S. CONSTRUCTION CO.
Pall Associates
M/s Adhikari construction co.
The new hut furnitures
J.P. Enterprises
V M CONSTRUCTION
Surjit and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .