Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹56.3 LAccepted-Finance C 9 53 SECTOR 8 ROHINI NEW DELHI 110085 | NEW DELHI | NEW DELHI | DELHI | 110085 | L1 | Accepted-Finance L1 | |
| 2 | L2₹61.6 L+₹5.3 L (9.43%)Accepted-Finance | L2 | Accepted-Finance L2 | |
| 3 | L3₹65.4 L+₹9.2 L (16.3%)Accepted-Finance C 88 NIRALA NAGAR NEAR 8 NO CHAURAHA LUCKNOW 226 020 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226020 | L3 | Accepted-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹99,700
Closing Date
22 Jul 2021, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Executive Officer
Delhi Cantonment Board, Sadar Bazar, Delhi Cantt.
Provision of HT connection and allied works to electric crematorium at Uri Enclave, Delhi Cantt
2021_DGDE_456950_1
DCB/8/E and M/C-1/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Uri Enclave, Delhi Cantt
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
Chief Executive Officer, Delhi Cantonment Board
₹99,700
12 Oct 2021
5 Jul 2021
23 Jul 2021
5 Jul 2021
22 Jul 2021
5 Jul 2021
5 Jul 2021 - 22 Jul 2021
120 days
Amount
Supplying, Installation, Testing and Commissioning of 11 KV, 630 Amps having short circuit capacity 20 kA/3-sec, Outdoor (IP54), RMU (Ring main unit) 10-way comprising of 02 Nos motorized operated Load Break Switch and 08 Nos 630 Amp Fixed-Type motorized spring-charging VCB electrolytic grade copper busbars all inside single, gas-filled, robotically welded stainless steel 304 (Non Ferrite Non Magnetic Grade) tank with min. thickness 3± mm, IP 67 Degree of Protection, internal-arc classified 20kA/1sec, on-site-repairable with site replacable bushing/ coupling/ mechanism, gas refilling etc. The enclosure shall have padlockable double-door access with anti-theft higes, fully covering the front facia and cable boxes to ensure fail-safe anti-theft protection. The unit alongwith Bus-connected, fixed-type Auxiliary transformer shall include the following along with all necessary accessories and fittings as required at site. Make :- ABB/Schneider/Siemens
(A) 02 Nos. Incoming Load Break Switch module each consisting of following accessories:- (i) Each switching-unit is designed as a three position switch. This three function switch combines the functions of switch-disconnector and earthing switch. (ii) 11kV, 630A Load Break Switch with interlocked line-earthing scheme both short circuit current – 20kA/3-sec, Making Capacity – 50kAp- 01No (iii) Auxiliary contacts – 1 NO + 1 NC - 01 No (iv) Spring-assisted snap-action motorised mechanism with un-inhibited operating shaft for emergency manual operation with integrated earthing switch - 01 No (v) Cable terminals (site replacable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes) with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access upto 11 KV, 300 Sqmm, 3 Core, XLPE AL cable termination in live-condition, Each set of 03 (vi) Right angle boots (push on type) - Each Set of 03 (vii) Arc proof cable covers having cable entry from bottom, front with interlocking mechanism including earth switch - 01 No (viii) Capacitive voltage indication fixed type system as per IEC61243 with LED - 01 Set ix) Fault Passage Indicator - it si to be provided for each incomer load break unit, FPI with LED/ digital display to be added for detection of cable fault - 01 No. (x) ON, OFF, EARTH mechanical indication on the front mimic of the panel - 01 No
(B) 08 Nos. Outgoing VCB module each consisting of following accessories:- (i) Each function-unit consists of a vacuum-circuit breaker in combination with a three position-switch. The three-position-switch fulfills the operation of the disconnector-function and earthing function. (ii) 11kV, 630A Fixed – Type VCB module with series disconnector cum earthing switch of short circuit breaking current/withstand – 20kA/3-sec, Making Capacity -50kAp - 01 No (iii) Aux. contacts - 1NO+1NC - 01 No (iv) Stored-energy motorized high-endurance spring charging mechanism (M1+), with inbuilt spring-charging lever and mechanically latched ON/OFF push-buttons to allow handle-less and un-inhibited operation - 01 No (v) Cable terminals (site replacable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes) with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access upto 11 KV, 185 Sqmm, 3 Core, XLPE AL cable termination in live-condition. Each Set of 3 (vi) Right angle boots (push on type) - Each set of 3 (vii) 3O/C + 1E/F self powered numerical protection relay with Low and High set for Over current and Earth Fault. Relay should have facility to display the maximum loaded phase current also. Relay shall record minimum 5 fault records with time stamping. Relay shall be communicable with RS 485 Port on MODBUS Protocol - 01 No (viii) Associated ring-core cast resin insulated CTs 100/1 amp, 2.5 VA, 10P10 for protection for six outgoing and CTs 200/1 amp, 2.5 VA, 10P10 for two outgoing - Each Set of 3 (ix) Arc proof cable covers with self interlocking mechanism with earth switch – 01 No (x) Capacitive voltage indication fixed type system as per IEC61243 with LED - 01 No (xi) Push button for breaker trip (xii) Shunt trip coil 24V DC - 01 (xiii) ON, OFF, TRIP mechanical indication on the front mimic of the panel - 01 No (xiv) Emergency Trip Push Button - 01
(C) 01 No. Bus-connected, fixed-type Auxiliary transformer with floor-mounted compartment of matching height and depth, positioned along-side RMU to provide required aux. supply and metering consisting of following accessories:- (i) 1 – Ph (11kV/rt3):230VAC, 500VA Auxiliary transformer - 01 No (ii) 2x12 Volt DC battery - 01 Set (iii) Battery charger - 01 No (iv) HRC fuse-links for primary side isolation and AC/DC MCBs for secondary isolation - 01 Set (v) Voltmeter & RYB LED indications to confirm AC/DC supply availability - 01 Set (vi) Anti-condensation space-heater - 01 No (vii) LED lamp for illumination and 3-pin socket with switch - 01 No
(D) Additional equipment delivered separately or mounted separately:- (i) Operating Handle for Manual isolator/ Disconnector/ Earthing Operation – 02 Nos (ii) Standard Manometer - 01 No (iii) Operation and Maintenance Manual - 01 No (iv) Installation & Commissioning Manual - 01 No (v) Cable clamping provision (standard) - 01 No
Note:- (i) It is preferable to have all feeder-switches inside single stainless steel compartment with incomer feeders at the extremities to prevent chances of failure due to plug-in coupling arrangement. (ii) Necessary interlocking arrangement shall be provided for safety and operations (iii) Above switchgear shall confirm to relevant IEC (62271-200) for design, manufacturing and internal arc compliance. Any claims towards internal arc compliance, number of mechanical/electrical/short-circuit operations, gas-leakage rates etc. shall not be accepted unless proven via type-test reports of model being offered. (iv) Cost of provn of plinth for RMU as per OEM drawing is deemed to be included in the cost.
Material and labour for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of earth plate not less than 2.5 mtr below ground level connected to galvanized iron strip 32 x6 mm by means of electric arc welding of galvanized iron or steel all as shown in electrical plate No5 of SSR Part I connected to earth test point and the equipment to be earthed all as specified including testing and commissioning complete all as directed at site.
M&L XLPE insulted, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 95 sqmm, 3 core. Make : Polycab, finolex, gloster, RR Cable, Havells.
M&L Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 95 sqmm to 120 sqmm.
M&L Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 150 sqmm to 185 sqmm.
M&L Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm.
M&L Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 95 Sqmm to 120 Sqmm
M&L Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 Sqmm to 185 Sqmm
Boring of hole under road/ pavement/hard standing or mechanically or any other situation by manual means and including GI pipe 100 mm bore (medium grade) and making good both ends all specified and directed
Supply and lay GI pipe light grade in replacement as cable protection laid on trench/floor, fixed on pole/wall etc of following sizes all as specified of size : -100 mm dia
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in any type of soil (soft/losse/hard/dense soil) for laying/ taking up/ taking down of cables and getting out and levelling of bottom surface required level all as specified and directed by Engineer-in-charge
Returning filling in, including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material (ie soil) from site to a distance n.exc 50 mtrs away and depositing where directed at a level n.exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-charge.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables, filling in existing Cable duct in side the sub station situated at different location for cushioning of cables and Sand filling under floors or in foundations of transformers including watering and consolidation etc complete all as specified
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mm x 180mm x 40mm
S&F MS work of angles for post and struts of fencing around transformers and RMU etc drilling holes, flat iron, fillet for securing wire mess by welding to angle iron frame and framed work as in gate of angle and wire mess. Door to be fixed by 03 Nos 100mm long hinges and one sliding door bolt of 300mm long for locking arrangement and MS channel for plinth of transformer complete all as specified and directed.
S&F 3.15 mm dia MS wire 75x75mm mesh, made up into mattress or cages appx 2.00 mtr height and fixed with flate iron/ angle by welding in position complete all as specified and directed
M&L for 2 coat of synthetic enamel painting over a coat of red oxide to steel surfaces including preparation of newly surface complete all as specified.
Dismantling of HT insulators any type, any size complete all as specified and directed
Dismantling of air break gang operated switches vertical/ horizontal mounted including insulators and operating mechanism.
Dismantling of cross-arms or MS channel or angle sections
Dismantling of GI pipe 80mm dia
Dismantling of existing 4/6 pole structure (rate is deemed to be inclusive of T&P and manpower) complete all as specified and directed
Bidder Name
Amount
LUMOS INFRA PVT LTD(GSTN-09AACCL9983E1Z1)
Rajindera Enterprises(GSTN-07AJDPK9984H1Z0)
AMIT ASSOCIATES(GSTN-07ACUPG0847K1Z7)
Rajindera Enterprises
LUMOS INFRA PVT LTD
Rajindera Enterprises
LUMOS INFRA PVT LTD
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .