Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.2 LAccepted-Finance | ₹4.2 L | 1 | Accepted-Finance 1 |
| 2 | 2₹4.3 LRejected-Finance 0 KALAMBAGH CHOWK MUZAFFARPUR BIHAR 842002 UDYAM BR 23 0013096 | MUZAFFARPUR | BIHAR | 842002 | ₹4.3 L | 2 | Rejected-Finance 2 |
| 3 | 3₹4.5 LRejected-Finance NULL | ₹4.5 L | 3 | Rejected-Finance 3 |
| 4 | 4₹4.8 LRejected-Finance | ₹4.8 L | 4 | Rejected-Finance 4 |
Tender Value
₹4.9 L
EMD Value
₹9,900
Closing Date
30 Mar 2026, 10:00 amClosed
EEE/KPZ
EEE/KPZ
Provision of lighting arrangement at MPL (Ramesh Park) Park A-1/320 Pashim Vihar Ward No-58 (Saraswati vihar) under Keshav Puram Zone
2026_MCD_273140_1
TC/ENGG./EEE/KPZ/2025-26/62.1
Open Tender
Electrical Works
60 days
EEE/KPZ
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
₹9,900
30 Mar 2026
25 Mar 2026
30 Mar 2026
25 Mar 2026
30 Mar 2026
25 Mar 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1ABC | |||||
| 1.01 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal/ coke and salt ) as required. | 3 | Set | 5,368 | ₹16,104 |
| 1.02 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. | 300 | PM | 42 | ₹12,600 |
| 1.03 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existingRCC/HUME/METAL pipe as required. Up to 35 sqmm | - | PM | 37 | - |
| 1.04 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Up to 35 sqmm | 30 | PM | 28 | ₹840 |
| 1.05 | S/L of following size DWC HDPE Pipe ISI marked along with all accessories like socket ,bend ,couplers etc.conforming to IS 14930 ,part II complete with fitting and cutting ,jointing etc .direct in ground (75 cm below ground level )including excavation and refilling the trench but excluding sand cushioning and protective covering etc, complete as required (a)63mm dia (OD-63mm ID -51mm nominal ). | 270 | PM | 247 | ₹66,690 |
| 1.06 | Providing and laying of HDPE PIPE OF 40mm outer dia with PN 4 rating by hand Moling/Mannual method Confirming to IS 4984 592 | 40 | PM | 592 | ₹23,680 |
| 1.07 | Supply of XLPE insulated, PVC sheathed Al. Conductor Armoured cable 1.1 KV grade confirming to IS-7098 of following Size (a) 2 X 6 Sq. mm | - | PM | 95 | - |
| 1.08 | Supplying, installation, Testing & Commissioning of Street light LED
fixture, powder coated pressure die cast aluminum body with built in or
separate driver as per the requirement with Driver efficiency >85%, Input
voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50
deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-
5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP66,IK-10, CRI >80 , under voltage and over voltage protection,EMIEMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as
per the width of the road and the project requirement., suitable to fit in up to
65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum
50000 Burning Hours with 70% of initial Lumen maintained till life
ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K /
4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard
Deviation Color Matching) <5, Maximum power consumption should not
more than the specified rating and Fixture shall be of relevant BIS standard
complete in all respect i/c connections with 1.5 sq mm FRLS, PVC
insulated copper conductor single core cable and earthing etc. as required
with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt
output . LM79 & LM80 Test report from NABL lab for all testing required
for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be
as approved by Engineer-in-Charge as per requirement. (Thermal
management: heat sink of aluminum housing such that LED junction
temperature shall not rise above 90°C).. 45 watt | - | Each | 1,879 | - |
| 1.09 | Fabrication, supplying and fixing class B galvanised single overhang arm bracket made out of 250 mm long galvanized top tube with cap and 250 mm long 32 mm dia galvanised pipe with tightening bolts complete as required. | 11 | Each | 1,380 | ₹15,180 |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
Tender_Condition_1.pdf
Tender Documents • 0.43 MB
MCD_GCC_Circulars_2025updated.pdf
Tender Documents • 13.95 MB
BOQ_318779.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid