Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC 28 SAMBHU BABU LANE KOLKATA 700014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L1 | Accepted-AOC AOC Issued | |
| 2 | L2₹28.1 L+₹13,347 (0.48%)Rejected-Finance 49 1 ISWAR GUPTA ROAD KOLKATA 700 028 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | L2 | Rejected-Finance that the bid is not L1 | |
| 3 | L3₹28.8 L+₹85,646 (3.07%)Rejected-Finance VILL P O NARIT P S AMTA DIST HOWRAH PIN 711413 | HOWRAH | WEST BENGAL | 711413 | L3 | Rejected-Finance that the bid is not L1 | |
| 4 | Rejected-Technical | - | Rejected-Technical Rejected due to absence of credential in similar nature of work within last 5(Five) years from the date of NIQ |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
24 May 2022, 1:00 pmClosed
EE KNHED PW Dte
KIT Building Annex, 4th Floor,P-16, India Exch. Place Extn., Kolkata -700073
Repair Renovation EI work of Old ladies Hostel building 2nd floor Administrative Building under R G Kar Medical College Hospital Kolkata
2022_WBPWD_379445_1
WBPWD/EE/KNHED/NIQ-11/22-23
Open Tender
ELECTRICAL WORKS ORG
Item Rate
21 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹50,000
22 Mar 2023
6 May 2022
26 May 2022
8 May 2022
24 May 2022
8 May 2022
Amount
.Cubicle Panel [General Description]:- Supply & installation of L.T.Cubicle type fully compartmnetalised wall mounted panel board with multi- tier arrangement, having rigid & self supporting structure and covered by 16SWG CRCA sheet with two coated ena-melled paint along with Louvre arrangement at side cable entry at bottom of the panel & cable exit at top of the panel with two sides cable alley.All in- coming & out -going SFU's are to be open execution type & housed in respective compartments with hinged & rubber gasketed doors at the front. All the doors should have panel lock arrangement in such a fashion that it can not be unlocked unless the respective feeder remains 'OFF'. The rear of the panel should have gasketed wire net guard for ventilatiion and arrangement should be made for easy access to each
compartment by providing front door with locking system.The panel is to be properly gasketed to preevent the dust & vermin. All vertical /horizontal busbar chamber are to be properly arranged & All electrical Switches, Bus-bars are to be fixed by MS nut,bolts on suitable hylam board/non hygroscopic insulators of adeq -uate size & dimension.The outgoing feeders connection respective switches are to be made by means of multi core copper (25sq. mm.) cables to be terminated on bolted type terminals for cable connections.There should be plate fas per direction of E.I.C. :- Incomer : i) 320A, 415V, Mainswitch with Switch disconnector fuse unit conforms to IS;13947 three pole & neutral 50Hz.,AC,415V.with 3nos. din type HBC fuse link (Make : L&T/ABB/Siemens) as below:-- 1 no.
Busbar Chamber: 400A.4-bar electrolytic tinned copper falts. The busbar is to be rigidly supported on suitable DMC/SMC moulded non-hygroscopic insulating materials FRP chairs.of robust fashion to withstand electromechanical stresses. All connections to bus is to be made by suitable nut bolt. The bus bar is to be wrapped with heat shrinkable PVC tape(Red,Yellow, Blue & Black) for identification with suitable box within the cubicle panel & hinged type door. Connections to bus is to be made by suitable nut bolt. The bus bar is to be wrapped with heat shrinkable PVC tape(Red,Yellow, Blue & Black) for identification with suitable box within the cubicle panel & hinged type door. Outgoing : Switch disconnector nfuse unit conforms to IS;13947 three pole & neutral 50Hz.,AC,415V.with 3nos. din type HBC fuse link
(Make : L&T/ABB/Siemens) as below:- (a).160Amps.--------------------------- 01 No. b) 125Amps...............01 C) 63 A................................06 Nos. Inter Connections :-The outgoing feeder connections from respective switches are to be made by power wiering shall be done from 50 sqmm for 160A & 125 A mainswitch , 35 sqmm single core flexible copper wires for 63A mainswitch with socketing & control wiring shall be done by 1.5sq.mm.copper wires with bolted type terminals for cable connections duct,ferrul,soxcket etc. Earthing : Two separate earth terminals. Errection : The Cubicle Panel to be installed at wall with proper hanging arrangement as per direction of EIC. Metering panel: a) Multifunction meter—1 set. b) S&F current transformer of size 400/5A Kappa make --- 3 nos.
c) S&F 20A Bakelite fuse base & bridge with 4A HRC fuse link GE make. – 3 nos. d) S&F 220V, AC resistance type LED indicator best quality indigenous make (Red, Yellow, Green) --- 3 nos. e) S&F Danger board --- 1 no. ( Location- Old ladis Hostel) with arrangement of double earthing connection main panel to near earth bus here to be connected (25x6) mm Galvanized (Hot dip) MS Flat as necessary requirment basis.
.Cubicle Panel [General Description]:- Supply & installation of L.T.Cubicle type fully compartmnetalised wall mounted panel board with multi- tier arrangement, having rigid & self supporting structure and covered by 16SWG CRCA sheet with two coated ena-melled paint along with Louvre arrangement at side cable entry at bottom of the panel & cable exit at top of the panel with two sides cable alley.All in- coming & out -going SFU's are to be open execution type & housed in respective compartments with hinged & rubber gasketed doors at the front. All the doors should have panel lock arrangement in such a fashion that it can not be unlocked unless the respective feeder remains 'OFF'. The rear of the panel should have gasketed wire net guard for ventilatiion and arrangement should be made for easy access to each compartment
by providing front door with locking system.The panel is to be properly gasketed to preevent the dust & vermin. All vertical /horizontal busbar chamber are to be properly arranged & All electrical Switches, Bus-bars are to be fixed by MS nut,bolts on suitable hylam board/non hygroscopic insulators of adeq -uate size & dimension.The outgoing feeders connection respective switches are to be made by means of multi core copper (25sq. mm.) cables to be terminated on bolted type terminals for cable connections.There should be plate fas per direction of E.I.C. :- Incomer : i)125A,Four Pole 415V, MCCB of breaking capacity 25kA/35kA ,hmake L&T/ABB/Legrand- 1 no. Busbar Chamber: 200A.4-bar electrolytic tinned copper falts. The busbar is to be rigidly supported on suitable DMC/SMC moulded non-hygroscopic insulating materials
FRP chairs.of robust fashion to withstand electromechanical stresses. All connections to bus is to be made by suitable nut bolt. The bus bar is to be wrapped with heat shrinkable PVC tape(Red,Yellow, Blue & Black) for identification with suitable box within the cubicle panel & hinged type door. Connections to bus is to be made by suitable nut bolt. The bus bar is to be wrapped with heat shrinkable PVC tape(Red,Yellow, Blue & Black) for identification with suitable box within the cubicle panel & hinged type door. Outgoing : 63A,Four Pole 415V, MCCB of breaking capacity 25kA/35kA with fixed thermal/adjustable thermal and fixed magnetic setting in the existing panel, (Make : L&T/ABB/Legrant).................5 Nos Inter Connections :-The outgoing feeder connections from respective switches are to be made by power
wiering shall be done from 35 sq.mm. flexible copper wires with socketing & control wiring shall be done by 1.5sq.mm.copper wires with bolted type terminals for cable connections duct,ferrul,soxcket etc. Earthing : Two separate earth terminals. Errection : The Cubicle Panel to be installed at wall with proper hanging arrangement as per direction of EIC. Metering panel: a) Multifunction meter—1 set. b) S&F current transformer of size 200/5A Kappa make --- 3 nos. c) S&F 20A Bakelite fuse base & bridge with 4A HRC fuse link GE make. – 3 nos. d) S&F 220V, AC resistance type LED indicator best quality indigenous make (Red, Yellow, Green) --- 3 nos. e) S&F Danger board --- 1 no. ( Location - Police Morgue) with arrangement of double earthing connection main panel to near earth bus here to be connected (25x6) mm Galvanized (Hot dip) MS Flat as necessary requirment basis.
Dismentling the existing E.I. work incl existing Panels( 2 nos ) by Co's own tools & tackles by maintening normalcy as far as possible as per direction of EIC
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Make-Legrand/ Siemens/L&T 4 way Enclosure (607913) as to GS ( location - Four star new ladis hostel)
Supplying and fixing 415 V four pole MCCB of breaking capacity 25kA/35kA with fixed thermal and fixed magnetic/adjustable thermal and fixed magnetic setting in existing DBs/ enclosure and necessary connection Make-Legrand / Siemens/L&T , as to GS.100 A FP for VTPNDB
Supply & Fixing the double door Horizontal TPN MCB Distribution board with IP-42/43 protection, on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Make-Legrand/ Siemens /L&T as to GS 6 way Enclosure (607715)
Supply & fixing the double-door SPN MCB Distribution Board with IP-42/43 protection, concealed on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Make-Legrand / Siemens/L&T/ABB ,2+12 way Enclosure (607712) as to GS
Supplying and fixing 240/415 V Isolator on din rail of existing DBs and necessary connection Make-Legrand/ Siemens/L&T, as to GS. i) 415 V, 100A FP for PBDB
ii) 240 V, 40A DP for LBDB
Supplying and fixing 240/415V, MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Make-Legrand/ Siemens/L&T as to GS. i) 6A - 32A SP MCB for PBDB & LBDB
ii) 63A TP MCB for VTPNDB
Supplying and Laying of following sizes Al. armoured PVC/XLPE cable surface on wall / on wall by clamp (Havells/Glostar/KEI/Polycab) with 2X10 SWG GI wire as per direction of EIC i) 4 core 120 sqmm (from Feeder piller box-8 to Electrical panel)
ii)4 core 95 sqmm ( from feeder piller box-8 to new ladis hostel Electrical pannel & Morgue Mortuary cooler incomer of Panel)
iii) 4 core 35 sqmm (from VTPNDB to TPNDB of Four star new Ladis Hostel)
iv)4 core 25 sqmm (from Old ladis hostel pannel to TPNDB & small pannel of morgue)
v) 2 core 10 sq mm ( for compund light)
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : i) 4 core 120sqmm
ii) 4 core 95 sqmm
iii) 4 core 35 sqmm
iv) 4 core 25 sqmm
v)2 core 10sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : i) 4 core 120sqmm
ii) 4 core 95 sqmm
iii) 4 core 35 sqmm
iv) 4 core 25 sqmm
v)2 core 10sqmm
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex/ Havells/KEI approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, with drop Concealed type if reqd as per direction of EIC to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish as to GS Av. run 9 mtr
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex/ Havells/KEI approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, with drop Concealed type if reqd as per direction of EIC to 5A 3 pin flush type plug socket & piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish as per G S i) On Board
ii) Separate plug (average run 7.5 mtr)
Supply & Fixing of following plug socket with separate Piano key type switch (Brand approved by EIC) on suitable sizes (16SWG) sheet metal switch board on wall incl. S & F bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required as to GS. i) 2 x 5 A Piano key type switch & Socket ( Separate Plug)
ii) 1 x 15/20A Piano key type switch & Socket
iii) 1 x 15/20A + 3 x 5 A Piano key type switch ,Socket , fuse & Indicator
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (make-Finolex/Havells/KEI) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required i) 2 x 1.5 sqmm + 1 x 1.5sqmm (for Separate Plug)
ii) 2 x 2.5 sqmm + 1 x 1.5sqmm (for Power plug)
iii) 2 x 6 sqmm + 1 x 4 sqmm (For SPN BDB )
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per G S i) 1.5sqmm
ii) 2.5sqmm
iii) 4.0sqmm
iv) 6.0sqmm
S&F angular holder (Anchor) incl. S&F 100 Watt BC lamp Philips make.as per direction of EIC
S & Fixing 240V superior type 6" size Gong bell (Anchor / PWD Appvd ) on HW board incl. S&F HW board .as per direction of EIC ( in each floor )
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting
Supply & Fixing Socket type fan regulator (Step type) (Anchor) on existing sheet metal switch board with bakelite/ perspex top cover by screw incl. making necy. connections etc. as per G.S.
Taken down the following existing fittings from its original position & storing properly incl . handed over the same at Section Store of R. G. Kar (MCH ) & than refixing the existing cealing and Exhaust fan as per direction of EIC i) Ceiling fan / Exhaust fan
ii) Single / Twin tube fitting (various type )
Supply & delivery 4 feet single commercial LED type fluorescent light fittings complete with all accessories with 1 x 20 Wt.Master LED Tube lamp similar to Philips make cat No. TMC-501 P 1xTLED 22 WP3241 corresponding to( Wipro / Bajaj / Crompton /Majic) as per direction of EIC
Fixing 4 feet LED tube with fitting & suspended bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp (125mmx125mm) as per direction of EIC
Supply & delivery exhaust fan (Make -- EPC, Heavy duty) of following sizes . length of PVC insulated wire and making connection for exhaust of dia incl. Fixing louver shutter as per GS i) 9" (23 cm)
Fixing 9'' & 12" ehaust fan on the wall with proper nut bolt arrangement as per GS.
Supply & Fixing of 60 W LED outdoor street light fitting ( Philips make cat No. BRP 062 LED 65 CW SLA SIPSU GR/CG ) complete with all accessories.
60 W LED outdoor street light fixed / Projected from the wall of the building incl. making holes to the building .S & F 40 mm dia / suitable size GI pipe 1.5 m average length (ISI-Medium) with GI socket at one end & thread at other end with suitable bend to house fitting and making necy. connections with S& F necy. length of Copper coductor and mending goods to wall incl. painting as per direction of E.I.C.
Supplying & Fixing of PVC water proof type Loop box(Make-Sintex) of size 8"X10" comprising of 4 way 100 Amp. Capacity brass stud/terminal make- AC /DC.,having hinged PVC top cover & 4 mm thick with rubber gasket lining,railway type mechanical locking arrangement,comprising of one 250V,15A kit-kat fuse unit,one NL on porcelain insulator etc. conceal in wall as per direction of EIC
S & F 230V 15A Piano Key type switch (Anchor) to be fixed on suitable size SM (16 SWG) Box in conceal in wall incl. S&F SM Box & wall matching perpex/bakelite top cover (3 mm thk) as to GS. (for controlling outdoor street light fitting fittings)
S & F 230V, 6A Piano Key type call bell switch (Anchor) to be fixed on suitable size MS (16 SWG) Box in conceal in wall incl. S&F SM Box & wall matching perpex/bakelite top cover (3 mm thk) as to GS. (for controlling Gong Bell from Gr Floor) )
Excavation of soil for installation of Earth Electrode and filling & ramming as to GS. For morrum soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed (:For Morrum Soil ISI-Medium GI pipe as to GS.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required as to GS.
Connecting the equipments to earth busbar including S & F No. 10 SWG GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages as to GS.
Supply & Delivery 240V 50 Hz 48" sweep (1200 mm) ceiling fan complete with down rod ,Canopy,fork etc. with out regulator, (Make- Usha (Technix) / Crompton Greaves (HS Plus 5 star) Orient ( 5 Star ) as per direction of EIC
Supply & Delivery 240V 50 Hz 48" sweep (1200 mm) ceiling fan complete with down rod ,Canopy,fork etc. with out regulator, (Make- Usha (Technix) / Crompton Greaves (HS Plus 5 star) Orient ( 5 Star ) as per direction of EIC
Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agency itself. (Defect Libilities period for 01 year from the date of completion of work)(Rate should be quotated including all taxes and duties)
Electromech Engineers Co-Operative Society Ltd.
ELEGANT POWER
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .