computer servers Average Turn Over of Last 3 Years 44 Lakh (s) Experience with Gov. Required 3 Year (s) Computer Servers ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values Specification Form Factor Rack Rack
Tower Size (RU) 2 - Processor Make Intel Intel
AMD
SPARC Max. Number of sockets available on chipset 2 Max. Number of sockets populated with processor 2 2 Number of core per Processor 8 As per GeM Catalogue. Processor Configuration Intel Xeon Silver 4110 ( 2.10GHz/8-core/11MB/8 5W) As per GeM Catalogue. Chipset compatible with CPU LATEST INTEL CHIPSET - Availability of Co- Processor No - If Yes Co-Processor Configuration NA As per GeM Catalogue. PCI Slots (Express Gen 8 - 1/4 3.0) Type of RAM DDR4 - RAM Size (GB) 128 128 RAM upgradable upto (GB) 3000 DIMM Slots (No.) 24 - Type of Hard Disk Drive SAS SAS
NL SAS
SSD
SATA Hard disk drive Capacity (GB) 1800 Hard disk drive Speed (RPM) 10K - RAID Controller Cache (MB) 2048 - RAID Type 5 - RAID Controller Ports @12 Gbps 2 - Video Controller (support VGA or above resolution) Yes - Keyboard Yes - Mouse Yes - Bays (min. 2 internal or more hot plug) 8 - USB Ports (version 2.0/3.0) 4 - Certifications Compliance support by Windows
Red Hat or Novell or Oracle Cluster S/W Yes - DVD ROM (or better) 8x or better - Network Card Supported 1G
10G
25G - FC HBA Dual port card NA - FC HBA Dual port card Speed NA - Power Management - - Redundant Power Supply Yes - Redundant Fan Yes - Total No of Ports 4 x 1GE - Declare SPEC int_rate_base 2006 ; SPEC CPU® 2006 benchmark should be - 2/4 specfp_rate_2006 for 1
2
4
8 prcessor as applicable 687 (60% SPECint_rate _base2006+ 40% SPECfp_rate_base2006) Server scalability to be achieved within the box without adding nodes Yes - RoHS Compliance Yes - BIS Registration number & its Validity - - Max. power consumption of the system (Watt) 750 - Availability of Type test reports consisting of verification of all the features & functional parameters & environmental tests sequences as under: a Dry heat test (For 16 hrs at a temperature of 45 degree C in accordance with IS: 90 00/part-3/section-5/197 7) b Cold test(For 4 hrs at a temperature of 0 degree C in accordance with IS: 9000/part-2/sec tion-4/1977 c Damp Heat Cyclic Test ( For 2 cycles of 24 hrs at a temperature of 40 degree C & 95% RH in accordance with IS: 90 00/part-5/section-1/198 1) Note:- The server shall be checked for all the parameters before conditioning
After completion of the above environmental tests sequence
with a recovery period of 1 to 2 hrs
the server shall be functional No - Name address of Lab - - Test Report No. date - - Power Supply 230 V +/-10%
50 Hz - On Site OEM Warranty (years) 3 1
3
5 (or higher) * Bold specifications are the golden parameters. 3/4 Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sanjeev Kumar 801507
AIIMS
Phulwarisarif
PATNA PIN-851507 2 15