Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.0 LAccepted-AOC 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹34.9 L+₹8.9 L (34.1%)Rejected-Finance BUDOOBAGH NOWPORA 0 KHANYAR SRINAGAR JAMMU KASHMIR 190003 | SRINAGAR | JAMMU AND KASHMIR | 190003 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹39.9 L+₹13.9 L (53.4%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L3 | Rejected-Finance Other than L1 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
17 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Cdr, HQ 138 WE
HQ 138 Works Engineers PIN-914138 C/O 56 APO
MISC MAINT WORKS OF CENTRAL HEATING SYSTEM AND HOT WATER PLANTS AT SEC HOSP ROCKFALL, HUNDER , KHALSAR, STN HQ, BDE HQ AND BDE LIVING AREA UNDER GE 873 EWS
2024_MES_660525_1
138WE/L-33/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE 873 EWS
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE 873 EWS
₹96,000
Yes
7 Oct 2024
19 Jun 2024
25 Jul 2024
19 Jun 2024
17 Jul 2024
3 Jul 2024
Amount
M&L dismantling carefully of Chimney smoke exhaust outlet fabricated extension MS pipe of boiler cleaning, removal carbon by scraping out and washing with scalent and acid/kerosene oil etc and removing of fume waste carbonized materials and disposal of fume waste every after 500 Hrs operation incl re-assembling all the dismantled component to its original position for smooth functioning of chimney, Complete all as specified and directed by Engineer-in-Charge.
M&L for dismantling oil fired hot water generator/boiler of 4 Lakh K.Cal/hour capacity any model by unscrewing and removal of boiler side/end plates, CHS control panel, cleaning drum and hot water coil with scalent de-carbonizing, scraping out carbon ,dirt acculated in drum and across coil, overhauling, servicing incl re- assembling all the dismantled component to its original position with testing and commissioning, Complete all as specified and directed by Engineer-in-Charge.
M&L for dismantling oil fired hot water generator of 2.0/2.50 Lakh K.Cal/hour capacity any model by unscrewing and removal of boiler side/end plates, CHS control panel, cleaning drum and hot water coil with scalent de-carbonizing, scraping out carbon ,dirt acculated in drum and across coil, overhauling, servicing incl re- assembling all the dismantled component to its original position with testing and commissioning, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of heat tracing cable (heating element) suitable for water supply pipe line complete all as specified and directed by Engr-in- Charge
M&L for dismantling oil fired hot water generator of 0.5 Lakh K.Cal/hour capacity any model by unscrewing and removal of boiler side/end plates, CHS control panel, cleaning drum and hot water coil with scalent de-carbonizing, scraping out carbon ,dirt acculated in drum and across coil, overhauling, servicing incl re- assembling all the dismantled component to its original position with testing and commissioning, Complete all as specified and directed by Engineer-in-Charge.
M&L for dismantling carefully CHS pump and motor assembly 7.5 HP for repair and remove the broken impeller and worn out nuts/bolts washer's complete incl rewinding removal of burnt winding for field and stator, rewinding the same with super enamel copper conductor of existing gauge varnishing, heating, baking complete with re-assembling all the dismantled component to its original position with testing, Complete all as specified and directed by Engineer-in-Charge. Note: Spares parts required for repair work will be measured in relevant item of BOQ as under
Supply only brass impeller
Copper winding wire suitable gauge of existing motor
M&L for disconnecting and removal of burner assembly, cleaning of Ecoflame burner for de-carbonized/deposited on combustion tank/blast tube with cleaning acid and fixing of burner nozzle for smooth functioning and re-assembling burner and fixed to its original position with testing , Complete all as specified and directed by Engineer-in-Charge. Note: Spares parts required for repair work will be measured in relevant item of BOQ as under
Supply only burner nozzle jet suitable for burner
Supply only photocell suitable for burner
Supply only fuel pump suitable for burner
Supply ony flexible metal fuel line suitable for plant
Supply only fuel filter
Supply only magnetic lead(Electrode)
Supply time relay suitable for CHS burner assembly
Supply only fuel Ignition transformer suitable for burner (ECOFLAME)
M&L for taking down carefully by disconnecting and removing Fan coil units of different sizes from hot water circulation line for cleaning with scalent and acid to remove the scale and dirt accumulated in copper tube, fins and cleaning of radiator parts of FCU and welding /brazing where ever necessary and arrest the leakage of the body incl re-assembling and connect the same to its original position with testing complete for smooth flow of water, complete all as specified and directed by Engineer-in-Charge. Note: Spares parts required for repair work will be measured in relevant item of BOQ as under
Supply only fan motor suitable for fan coil unit
Supply only PCB board suitable for existing FCU
M&L for disconnecting hot water inlet & outlet of glycol base storage tank of capacity 1000 Ltrs draining out complete old water cleaning, removal of sludge acculated by scraping out, washing with scalent/acid for properly cleaning and welding wherever necessary to arrest leakages with re-assembling the disconnected pipes to original position and filling water including refilling/ charging of glycol (monoethylene glycol) MEG concentrate along with necessary additives and inhibitor in cognition and mixed in ratio 40% (glycol concentrate) 60 % of water and the freezing temperature of mixture shall be -40 degree centigrade, Complete all as specified and directed by Engineer-in-Charge. (Note : Monoethylene glycol will be measeured and paid separetely)
Supply and fixing in replacement of unserviceable fan coil unit and Supply and fixing new fan coil unit of capacity 3000 K/Cal capacity High Wall mounted motorised valve alongwith Inlet outlet valves and remote control complete all as specified and as directed. Make-GET/Bluestar/Voltas.
Supply and fixing inreplacement of unserviceable fan coil unit and Supply and fixing new fan coil unit of capacity 4500 K/Cal capacity High Wall mounted motorised valve alongwith Inlet outlet valves and remote control complete all as specified and as directed. Make-GET/Bluestar/Voltas.
Supply and fix replacement of monoblock pump mtor for circulation of hotwater 5HP 3 phase 415 volt 50 Hz complete all as specified and directed.
Supply and fix replacement of monoblock pump mtor for circulation of hotwater 3HP 3 phase 415 volt 50 Hz complete all as specified and directed.
Supply and fix ball brass valve with adapter screwed both ends of 15 MM bore suitable for heat radiator hot water inlet/outlet, Complete all as specified and directed. Make : CE /Zoloto/Leader/ R&N
S&F metal coupling of the CHS pump 2 HP male/female star couppling as per sample, Complete all as specified and directed.
Supply and fixing coupler with fiber super impregnated suitable to match the male/female couplings as per sample held with Sub Div AGE E/M Partapur, complete all as specified and directed.
Supply and fixing PVC flexible pipe insulated model SAE 100 RIAT 1/2" suitable for fixing with heat radiator hot water inlet and out let with locking clips, complete all as specified and directed.
S&F in replacement of U/S chimney exhaust extension pipe of size 200 mm dia 3 length 6 mm thick, Complete all as specified and directed.
M & L Calibration of humidity control system to maintain required humidity for smooth functioning & maintaining the humidifier to required humidity, complete all as specified and directed.
S&F in replacement of U/S phase sequence meter 230 volt 50 Hz AC as per sample for each phase , complete all as specified and directed. Make : L&T/C&S/Havells/Legrand
Supply, mixing and filling of mono ethylene Glycol concentrate along with necessary additives and inhibitor in congnition and sealed in barrels. The mixture freezing tempreture shall be (-) 35°C, all as specified. The mode of payment and operation involved for this item shall be as under:- Note: (a) Mono Ethylene Glycol in concentrated from shall only be measured and paid under this item. (b) Material and labour for mixing, filling, preparation fo Gylocol Charge to get total quantity of mixture including first filling required for operation of CHS plant and network having 40% quantity of treated water available at site and 60% of mono ethylene glycol supplied as above to attain the freezing temperature of mixture as (-) 35°C. The quoted rates shall be deemed to include the above activity/work. (c) The water for preparation of mixture will be supplied by MES without any extra charges for this item (only). The water shall be supplied at a point decided by GE and quoted rates shall deemed to be included for transportation of same from the take off point. (d) Any other additives and inhibitors as per the requirement laid down in relevat IS shall also deemed to included in quoted rates. (e) Empty barrels shall be the property of contractor. Make: Indian oil/Hindustan petroleum/Bharat Petroleum/Caltax
S&F copper tubing of size 15 mm including necessary fittings like union and adopter including all fitting for inlet and outlet complete all as specified and as directed.
M & L for Insulation of MS pipe with PUF slab 30/40 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet for following sizes :-
(a) 80mm bore pipe
(b) 65mm bore pipe
(c) 50mm bore pipe
(d) 40mm bore pipe
(f) 32mm bore pipe
Excavation in trenches not exceedng 1.5 mtr wide and n. exceeding 1.5 mtr in depth for laying of pipe and getting out all in any type of soil complete all as specified and as directed.
Returning filling in including spreading watering and well ramming in layer not exceeding 25mm thick in any type of soil complete all as specified and as directed.
Removing excavated material (soil) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point complete all as specified and as directed.
M&L for cement concrete in foundation, filling and mass concrete type B-1 1:2:4 using 20mm graded crushed stone aggregate for foundation complete all as specified and as directed.
M&L for arc/gas welding for repair any leakages of hot water pipeline if necessary complete all as directed. Note:- Necessary tool & plant will be provided by the contractor
M&L for duct insulation with resin bonded fibre glass wool roll of density 24 kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation as specified and including the following:- (a) M&L for cleaning the duct surface (to be insulated ) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) M&L for applying rubber based adhesive CPRX compound. (c) M&L for sealing of alllongitudinal joints and circular overlaps with and including Aluminium foil tape 50 mm wide, to make the insulation leakproof. (d) M & L for securing the insulation with and including mechanically fastened nylon/ steel straps of size 12 mm/50 mm at maximum intervals of 1.2 mt
M&L for dismantling of AHU including taking down blower and blower motor,servicing of AHU,replacing of damaged parts like thermal sensor, blower shaft bearing, blowerbelt, hepafiter, refix the same after repair and making it functional complete all as specified and directed Note: Spares parts required for repair work will be measured in relevant item of BOQ as under
Blower fan belt suitable for existing size
Heppa filter (99.9 Micron)
Blower shaft bearing
Control relay suitable for existing capacity
Supply and fixing of fins type heating element 3 KW each and make necessary arrangement and electrical conections in duct complete all as specified and directd
Supply, laying, testing and commissioning in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross-sectional area 25 Sqmm 3.5 core complete all as specified and directed
Top Mind Industries Pvt Limited (BID ID -3054833)
national engineering (BID ID -3056766)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .