Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.4 CrAdmitted-Finance | -32.55% | ₹2.4 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.6 CrAdmitted-Finance | -26.89% | ₹2.6 Cr | L2 | Admitted-Finance |
| 3 | L3₹2.6 CrAdmitted-Finance | -25.61% | ₹2.6 Cr | L3 | Admitted-Finance |
| 4 | L4₹2.6 CrAdmitted-Finance | -25.57% | ₹2.6 Cr | L4 | Admitted-Finance |
| 5 | L5₹2.7 CrAdmitted-Finance | -23.75% | ₹2.7 Cr | L5 | Admitted-Finance |
Tender Value
₹4.2 Cr
EMD Value
₹8.4 L
Closing Date
23 Feb 2026, 4:00 pmClosed
Executive Engineer PWD RNB Div Pahalgam
Executive Engineer PWD RNB Div Pahalgam
Development of Holy Ghat at Chaka Nadi Bongam Mattan, Anantnag
2026_PWDJK_301994_1
eNIT 194 of 2025-26
Open Tender
Civil Works - Others
730 days
pahalgam
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,500
MH 0059
₹8.4 L
Office of the Superintending Eng PWD Circle Ang
5 Mar 2026
2 Feb 2026
24 Feb 2026
2 Feb 2026
23 Feb 2026
2 Feb 2026
4 Feb 2026
C/o Boundary Wall Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres
Providing and laying stone soling hand packed. Incl. carriage complete.
Providing and laying in position specified grade of cement concrete excluding the cost of centering and, shuttering, All work up to plinth level 1:4:8 (1cement: 4 coarse sand: 8 graded stone aggregate (20mm nominal size) incl carriage of material from 15 kms
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level:1:1.5 :3 (1 cement: 1½ coarse sand: 3 graded stone aggregate 20 mm nominal size) incl carriage of material from 15 kms
Reinforced cement concrete work in walls (any thickness) courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1.5:3 (1) cement: 1½ coarse sand 3 graded stone aggregate 20 mm including attached pilasters, buttresses, plinth and string nominal size) incl carriage of material from 15 kms
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level: Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases for columns etc.
Columns, pillars, piers, abutments, posts and struts.
Lintel, beams, plinth beams, girders, bressumers and cantilevers.
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in: Cement mortar 1:6 (1 cement: 6 coarse sand) including carriage
Providing and applying average 15 mm thick cement plaster in single coat in cement mortar 1:6 upto 10 m above ground including scaffolding etc. complete.
Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10 sqm)
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying an priming coat of approved steel primer all complete.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new
C/o of Entry Gate A Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: All kinds of soil:
P/L Stone soling/RBM i/c leveling, conslidation with 8-10T PRR including cost andcarriage of all materials involved (complete job).
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level in 1:1.5:3 (1 cement: 1½ coarse sand: 3 graded stone aggregate 20 mm nominal size) i/c all carriages
Reinforced cement concrete work in arches, archribs, domes, vaults, shells, folded plate and roofs having slope more than 15° upto floor five level including curing but excluding the cost of centering, shuttering finishing and reinforcement with 1:1.5:3 (1 cement: 1½ coarse sand: 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of formwork for foundations footings etc
Centering and shuttering including strutting, propping etc. and removal of form for: Arches, domes, vaults upto 6 m span
Cement plaster in 12 mm thick in 1:4 mix mortar.
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar work
Stone work (machine cut edges Veneer work) for wall lining upto 10 m height, backing filled with a grout of 12 mm thick cement mortar 1:3 (1 Cement: 3 coarse sand) and jointed with Cement mortar 1:2 (1 cement: 2 stone dust), including rubbing and polishing complete. (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) 8.39.1 Kota stone slab exposed face dressed & rubbed
Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers' specifications: Two or more coats applied @ 1.25 liter/10sqm over and including one coat of special primer applied @ 0.75liter/10sqm Painting steel work with deluxe multi surface paint of required shade to give an even shade. Two or more coats applied @ 0.90litre/10sqm over and an under coat of primer applied @ 0.80litre/10sqm of approved brand and manufacture
Finishing walls with textured exterior paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @ 2.20kg/10sqm
Carriage of material by using mech tpt for an average lead of 20 km. Sand/bajree
Development of Holy Ghat BWO development of stream pathways and sitting area and hawan area. Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres, for all kinds of soil.
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including disposal of excavated earth, lead upto 50 meters and lift upto 1.5 m, for all kinds of soil, specifically for Devri Paths.
P/L stone Soling including carriage and laying hand-packed complete job at site
Providing and laying in position cement concrete of specified grades including curing but excluding the cost of centering and shuttering. All work upto plinth level with 1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40 mm nominal size)
Providinjg and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 40 mm nominal size)
P/L RBM/boulder filling including carriage and laying hand-packed complete job at site.
Providing and laying chisel dressed Devri Stone of size 300x200 mm face with 150 mm depth in cement mortar 1:6 (1 cement: 6 coarse sand) upto plinth level including curing. One face dressed Rough chisel dressed
Providing and laying rough chisel dressed Devri Stone in kerbs, of size 200x200 mm face with chamber in cement mortar 1:6 (1 cement: 6 coarse sand) including curing.
Kota stone slab 20 mm thick in risers of steps, skirting, dado, and pillars, laid on 12 mm (averaqge) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing, polishing, and curing complete.
Chequered precast cement concrete tiles 22mm thick in footpath and courtyard, jointed with neat cement slurry mixed with pigment to match the shade of the slabs, including rubbing, cleaning, and curing complete on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Ordinary cement without any pigment.
Structural steel work in built-up sections, trusses, and framed work, including cutting, hoisting, fixing, and applying a priming coat of approved steel primer all complete. Welded.
Providing High rib Colour Profiled G. S. sheets roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in orizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.50 mm thick with zinc coating not less than 275 gram/m2. Including ridges, Hips and Valleys complete job
Carriage of items by mechanical means transport from 15 km average lead. sand aggregate
C/o Langar area Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres:All kinds of Soils
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
Providing,Laying, spreading and compacting stone aggregate of specified sizes in uniform thickness, hand picking, rolling watering and compactingIncluding all carriages and lifts upto the site of work complete job
Providing and laying in position specified grade of cement concrete excluding the cost of centering and , shuttering , All work up to plinth level 1:4:8 (1cement: 4 coarse sand : 8 graded stone aggregate
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete
Supply and filling of RBM conforming to specifications, carriage of material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness not exceeding more than 200mm and compacting to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
Providing and laying in position specified grade of cement concrete excluding the cost of centering and , shuttering , All work up to plinth level 1:2:4 (1cement: 2 coarse sand : 4 graded stone aggregate (20mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and einforcement. All works upto plinth level 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately.All works upto plinth level
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately.All works above plinth level
Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases of columns etc. for mass concrete.
Walls (any thickness) including attached pilasters, buttresses, plinth and
Suspended floors, roofs, landings, balconies and access platforms
Edges of slabs and breaks in floors and walls Under 20 cm wide
Lintel, beams, plinth beams, girders, bressumers and cantilevers.
Columns, pillars, piers, abutments, posts and struts
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete
Providing and Fixing factory made UPVC door/window frame, made of UPVC extruded sections , of size 65 mm x 55 mm with wall thickness 2.0 mm ( ± 0.2 mm) , corners of the door frame to be mitred cut and jointed with plastic brackets and stainless steel screws, reinforcing hinge side vertical of the frames with PVC profile of Size 28 mm x 30 mm having wall thickness 2 mm (±0.2 mm), including providing & fixing 3 nos of 125 mm long stainless steel hinges to the frame, fixing the frame with jamb with required number & size of anchor dash fasteners, all complete as per manufacturer’s specification and direction of Engineer-in-charge.
Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Casement cum fixed panel window having both end single casement panel, middle fixed panels and at top completely fixed ventilator with S.S friction hinges (350 x 19 x 1.9) made of (big series) frame 67 x 60 mm , sash 67x 80 mm &mullion 67 x 80 mm all having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area of window above 3.00 sqmu pto 5.00 sqm).
Providing and fixing factory made uPVC white colour fixed glazed windows/ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)
Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and Drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Three track three panels sliding door made of (big series) frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of door above 5.00 sqm)
Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and Drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Two track two panels sliding door made of (big series) frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqmupto5.00 sqm)
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand)
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
12mm Cement plaster on the rough side of single or half brick wall of mix:1 : 6 ( 1 cement : 6 coarse sand)
6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand)
Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Welded.
Providing Hi-Rib roofing sheet including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers including ridges, valleys and Hips complete job.
Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete 2 mm thick
Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm)
Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm)
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/ liter, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m in -All kinds of soil.
Carriage of material by using mech transport for an average lead of 20 km. A) Sand
b) Aggregates 40 mm and above
c) Stone soling
d) Bricks
Sanitary Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid.
Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour:600 mm long towel rail with total length of 645 mm, 78 mm wide and effective height of 88 mm, weighing not less than 190 gms.
Providing and fixing toilet paper holder C.P. brass
Providing and fixing health faucet with concealed fitting arrangement of approved quality and make.
Providing & Fixing CP brass Short body bib cock including, necessary flange, cutting and making good he walls / floors wherever required complete.
Providing & Fixing CP brass long body bib cock including, necessary flange, cutting and making good he walls / floors wherever required complete.
Providing & Fixing CP brass coat hooks (double) of approved make. Including providing & fixing C.P brass screws, washers, rawal plug etc.
Providing and fixing 15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing not less than 1.970 kg.
Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (a) 15 mm nominal dia
Providing & Fixing Wall Mounted C.P. Brass Sink Mixer single hole tap with swinging costed spout of required size including cuttinig and making good the wall wherever required.
Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931
Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements,weighing not less than 106gms.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Providing and fixing PTMT grating of approved quality and colour150 mm nominal size square 100 mm diameter of the inner hinged round grating.
Providing and fixing Floor Traps including all fittings required complete job 100m dia
Providing and fixing Floor Traps including all fittings required complete job 75 mm dia
Providing, Fixing, Testing & Commissioning uPVC SWR pipes (Type-B) for soil, waste, and vent conforming to IS 13592 along with all required fittings like tees, bends, cowls, crosses with or without access doors jointed with approved solvent cement fixed to walls and ceilings including angle supports with clamps complete including cutting holes in R.C.C/brick work (slab/beam/wall) and making good the floors, beams and walls with cement mortar where required complete of outer diameter.(Soil/ Waste pipe) a) 75 mm dia.
b) 100 mm dia
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge.Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. a) PN-16 pipe , 20mm OD(SDR-7.4
b) PN-16 pipe , 25mm OD(SDR-7.4)
c) PN-16 pipe , 32mm OD(SDR-7.4)
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. 19.2.1 External work including trenching, refilling etc. PN-16 pipe, 40mm OD (SDR-7.4)
Providing, fixing, testing & commissioning of forged brass nickle plated lever operated ball valve of full bore with forged brass hard chrome plated ball with min. working pressure of 10 Kg/cm2 Hydraulic test pressure at seat & shell shall be 16 Kg/cm2 . Lever should be anti rust coating, complete in all respects (For Domestic CWS/FWS Application). a) 25 mm dia
b) 32 mm dia
c) 40 mm dia
Providing and fixing PPR Unions PPR Union 25mm
PPR Union 32mm
PPR Union 40mm
PPR Union 50mm
PPR Union 63mm
Providing and fixing 8mm dia jet with flexible tube upto 1 m long
Supply installation testing and commissioning of 2 HP water pump for lifting of water
Supply installation testing and commissioning of water heaters (Gysers) 50 litre capacity ISI marked
Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required. White glazed fire clay kitchen sink of size 600x450x250 mm
P/F PVC reducer 100-40mm dia
Construction of brick masonry inspection Chamber (600x600)mm inside depth upto 600mm in brick work in cement mortar 1:4 mix RCC top slab with 1:2:4 mix foundation concrete in 1:4:8 mix, inside plastering 12mm thick in cement mortar 1:3 mix with flitting coat of neat cement and marking channels complete including cost of manhole frame and Cover of required size of standard quality and carriage of all materials involved complete
Providing and fixing in position polyethylene septic tank type-B (Comfort or equivalent ) having capacity for 50 users, 55"x59"x157" inches in size, including excavation of put as per the size, providing and laying of 150mm thick bed concrete in 1:4:8 mix (1: cement:4 course Sand :8 graded stone agg 20mm nominal size) filling the septic tank with fresh water, connecting the inlet and outlet with the septic tank and filling the dry course of sand and bajre around the septic tank complete Job including carriage of all materials involved
C/o Pandal infront of Temple Earthwork in excavation by mechanical means (Hydraulic excavators) in trenches for foundation, drains, pipes, cabels etc (not exceeding 1.5 M, in width) and for shafts, wells, cesspits and the like not exceding 10Sqm on plan, depth upto 1.5M including disposal of excavated earth upto 1mtrs from cutting edge, disposed earth is to be levelled and neatly dressed in all kinds of soil.
Providing and laying of stone soling hand packed and compacted with hand roller including carriage complete.
Providind and laying in position cement concrete of specified grade excluding the costs of centering and shuttering-all work upto plinth level. 1:4:8 (1cement: 4coarse sand : 6 crushed aggregate 40mm) excluding coast of carriage
Providing and laying in position Specified grade of reinforced cement concrete excl c/o centering and shuttering, finishing and reinforcement all work 1:1.5:3 (1cement:1.5coarse sand: 3graded stone aggregate 20mm nom size). Excluding cost of carriage.
Providing and laying in position cement concrete of specified grade excluding the costs of centering and shuttering-all work upto plinth level. 1:3:6 (1cement: 3coarse :6 sand, crushed aggregate 20mm) excluding cost of carriage.
Providing and laying in position cement concrete of specified grade excluding the costs of centering and shuttering-all work upto floor V level. 1:2:4 (1cement: 2coarse :4 sand, crushed aggregate 20mm), excluding cost of carriage
Supply and filling of Stone dust/stone screenings at site incl loading unloading carriages complete.
Centering and shuttering including shutting, proping etc and removal of same work.
Reinforcement for R.C.C work in caps, Rafts, Grade beam, plinth beam etc, incl straightening, cutting, bending, placing in position and binding all complete.Mild steel and medium tensile steel bars
Providing and fixing of first quality ceramic glazed wall / floor tile of standard quality conforming to IS 15622 in white, ivory, grey colours including grouting of joints with white cement and matching pigment complete job as approved by EIC.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes a) Tubular Section
b) Structural Steel
Providing anf fixing of 16mm Anchor bolts (450mm length) consist of threaded end to which and nut and washer can be attached for the extenal load .
Providing and fixing wall panel (Puff panel) insulated thick panel sheets b/s with density of work 40kg/ml on steel frame necessary fitting all carriages complete with 0.5 mm
Providing hi rib sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.50 mm thick with zinc coating not less than 275 gram/m, including Ridges and Valleys.
Painting steel work with deluxe multi surface paint of required shade to give an even shade. Two or more coats applied @ 0.90litre/10sqm over an under coat of primer applied @ 0.80litre/10sqm of approved brand and manufacture
Electricification for Pandal Wiring for lighting points/fan points/exhaust fan points/call bell points with 2x1.5 sq mm FRLS/HFFR PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit, with 240V 6A modular switch ,modular plate, suitable GI box and earthing the point with 1.5 sq mm FRLS/HFFR PVC insulated copper conductor single core cable, etc. as required. (Havells/ Polycab/ Anchor/ SSK) including the cost of conduit.
Supply, Installation, Testing and Commissioning of 18W/+ LED recessed/mounted (round or square) Down lighters having aluminum body, minimum 100lm/w, average life 50000 hours, Operating temperature -10°C to +45°C.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India.The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. (Havells/ Philips/ Crompton/ Jaguar/Wipro).
Supply, installation, testing and commissioning of 1200 mm (48”) BEE Star rated energy-efficient ceiling fan, complete with 3 Nos. aluminum blades, downrod, canopy, capacitor, safety pin, nuts, bolts and washers, suitable for 230 V, 50 Hz AC supply. The fan shall have air delivery not less than 220 m³/min, rated speed (RPM) between 340–380 (as per manufacturer’s specification), power consumption not exceeding 50 watts, service value ≥ 6.0, noise level ≤ 60 dB, insulation class ‘B’ and insulation resistance > 2 MΩ. Fan shall be of approved make such as Usha / Havells / Crompton / Orient or equivalent, including installation, online RPM verification, testing, commissioning and handing over to the Engineer-in-Charge, with minimum 2-year manufacturer warranty.
Supplying and fixing ISI-marked 6 A, 250 V modular step-type electronic fan regulator (2 Module), conforming to IS:3854 or latest IS standards, mounted on suitable modular plate with GI flush box, including wiring connections, testing and commissioning, of approved make such as Anchor Roma / Legrand / Schneider / Havells, complete as per direction of the Engineer-in-Charge.
Supply, Installation, Testing and Commissioning of 50W (Havells/ PhillIps/Wipro skyline ) new generation energy saving and environmental friendly long life L.E.D Flood Light made up of pressure die cast Aluminum housing with high efficiency LEDs as lighting source with efficacy >110lm/w ,CRI>80 ,CCT>5000 ,Avg Life L70 50000 hours ,No haremful UV and IR radiators, Operating Temp -10°C to +45°C ,Surge Voltage Protection, IP66 Protection and impact resistance of IK07.The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch connections etc. as required.( Anchor roma plus/Legrand Mylinc /SSK/Schneider Zencelo /Crabtree athena make).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 No. 3 pin 5/6 A modular socket outlet and 5/6 A modular switch connections etc. as required.( Anchor roma plus/Legrand Mylinc /SSK/Schneider Zencelo /Crabtree athena make).
Wiring for AC/Power plug points (15/16A heating points) with 2x4 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit along with 1x4 sq. mm FRLS PVC insulated copper conductor single core cable for earthing, etc. as required.(Havells/ Polycab/ Anchor/ SSK) including the cost of conduit.
Wiring for 5-10A socket out lets for computer with 2X2.5 sq. mm FRLS PVC insulated copper conductor (Havells/ Polycab/ Anchor/ SSK) as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit, alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for earthing etc. as required including the cost of conduit.
Supplying and fixing of indicators on existing modular plate and switch box , incl. connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or equivalent).
Supplying and fixing modular blanking plate on the existing modular plate switch box excluding modular plate as recquired.
OUTDOOR PANEL FOR PANDAL Design, Fabrication, Supply, Installation, Testing and Commissioning of the following panel, made out of 2 mm thick M.S. sheet, vermin- and dust-proof, outdoor type, with suitably sized angle-iron legs grouted in cement concrete, provided with lockable hinged doors, duly painted, and arranged for the installation of incomer MCCB, outgoing DP MCBs, and sets of aluminium busbars of various ratings (after taking derating factors into account), along with all other allied accessories as required. The panel shall be fabricated by a reputed firm duly approved by CPRI, as per the approved design (size may vary as per site requirement)
Providing and fixing of the following protection equipment and all other allied accessories, including making the necessary connections and interconnections with suitable size PVC-insulated copper conductor cables, and including earthing, complete as required. INCOMING: a)100A DP MCB Legrand/ Shinider/L&T/ABB make.
b) 4 No. of Aluminium Bus Bar of 200 Amp.
c)Digital meters and phase indicators 1 set.
OUTGOING: a)5-32 SPMCB
Supply, laying, connecting and commissioning of 10 sq mm 2 core XLPE/ PVC Insulated and steel armored 1.1 KV grade Aluminum LT cable for pathway poles, incl. cost of required al. thimbles duly crimped. (Over head/ under ground).
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting the concrete path wherever required,jointing etc.direct in ground including excavation and refilling the trench with soft excavated earth making the surface level but excluding sand cushioning and protective covering etc., complete as required. 35-40 mm dia
Earthing with G.l. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
Supplying and laying 6 SWG G.l. wire at 0.50 Meter below ground level for conductor earth electrode, including connection/ termination with Gl thimble etc. as required
Wiring for Circuit/Sub mains along with earth wire in FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires in recessed or surface conduiting system, including the cost of conduit. (Havells/ Polycab/ SSK/ Anchor/KEI/RR or equivalent). 2x 2.5 sq mm + 1x 2.5 sq mm Lighting circuit
2x 4 sq mm + 1x 4 sq mm Lighting circuit
Development of Stream Pathways and sitting area and hawan area. Supply, erection, installation, testing, and commissioning of heritage architectural ornamental decorative cast iron (base) and mild steel (mid portion) pole with 50 W warm white LED post lamp at the top, enclosed with suitable acrylic glass and aluminium top, as per approved drawings/specifications, of make Philips / Bright Solar / Homdec / Mayfair or equivalent approved by the Engineer-in-Charge (EIC). The pole shall be 3000 mm high with an ornamental CI base of 950 mm height, round (Ø 350 mm) or square (300 mm × 400 mm) in shape, including a 12 mm thick base plate, four anchor bolts grouted in concrete, and provision for an inbuilt junction box for MCBs and connectors with a detachable window cover. The pole shall be finished in matte black/antique shade with double-coat PU paint. All dimensions are indicative and may vary within ±5%; any deviation from approved drawings shall not be accepted. The work includes supply and fixing of the 50 W LED luminaire,5A SPMCB,63A 4P Connector including their costs, submission of manufacturer’s test certificate confirming compliance with the specified parameters, and approval of the sample by the EIC. A comprehensive warranty of one (1) year shall be provided for both the pole and the LED luminaire against any manufacturing defects, commencing from the date of successful commissioning.
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres:
Providing and laying in position cement concrete including curing but excluding the cost of shuttering and centring with 1:1.5:3 (1 cement, 1.5 Coarse sand, 3 Graded stone aggregate 20 mm nominal size). The dimensions of the block should be 3'x2'x2'.
Steel reinforcement for R.C.C. work ready to use "cut and bend" rebars of approved make from factory/workshop to construction site including placing in position and binding all complete.Thermo-Mechanically Treated bars of grade Fe-500D or more with 14kg/cum.
Supply,Laying, testing and commissioning of AL cable XLPE/PVC insulated, steel armoured 1.1KV Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havells/Polycab/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size. 16 sq.mm 4 core
10 sq.mm 4 core
Providing of service connection and earthings to luminaire from the junction box in 1.5 sq mm PVC insulated, multicolour copper wire (FRLSH) . Havells/Polycab/SSK/KEI.
Supply and Installation of Spiral Earthing through 10 swg GI wire after driving in ground up to a depth of 3' in the ground from the base of the pole.
Main Panel Design, Fabrication, Supply, Installation, Testing and Commissioning of the following panel, made out of 2 mm thick M.S. sheet, vermin- and dust-proof, outdoor type, with suitably sized angle-iron legs grouted in cement concrete, provided with lockable hinged doors, duly painted, and arranged for the installation of incomer MCCB, outgoing DP MCBs, and sets of aluminium busbars of various ratings (after taking derating factors into account), along with all other allied accessories as required. The panel shall be fabricated by a reputed firm duly approved by CPRI, as per the approved design (size may vary as per site requirement)
Providing and fixing of the following protection equipment and all other allied accessories, including making the necessary connections and interconnections with suitable size PVC-insulated copper conductor cables, and including earthing, complete as required. INCOMING: a)100 amp TPN MCCB 35 KA including spreader links, (Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/L&T/ABB make.
b) 4 No. of Aluminium Bus Bar of 250 Amp.
c) digital time switch astronomical (GIC ASTRO)
d) 40/63A automatic modular contactor with manual override (Havells/L&T,Schnider)
OUTGOING: a) 63 amp TPN MCB
b)5-32 SPMCB
Supplying and laying of 63 mm dia (OD-63 mm & ID-51 mm nominal) size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
Electrification of LANGAR AREA Wiring for lighting points/fan points/exhaust fan points/call bell points with 2x1.5 sq mm FRLS/HFFR PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit, with 240V 6A modular switch ,modular plate, suitable GI box and earthing the point with 1.5 sq mm FRLS/HFFR PVC insulated copper conductor single core cable, etc. as required. (Havells/ Polycab/ Anchor/ SSK) including the cost of conduit.
Supply, Installation, Testing and Commissioning of 18W/+ LED recessed/mounted (round or square) Down lighters having aluminum body, minimum 100lm/w, average life 50000 hours, Operating temperature -10°C to +45°C.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India.The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. (Havells/ Philips/ Crompton/ Jaguar/Wipro).
Supply, installation, testing and commissioning of 1200 mm (48”) BEE Star rated energy-efficient ceiling fan, complete with 3 Nos. aluminum blades, downrod, canopy, capacitor, safety pin, nuts, bolts and washers, suitable for 230 V, 50 Hz AC supply. The fan shall have air delivery not less than 220 m³/min, rated speed (RPM) between 340–380 (as per manufacturer’s specification), power consumption not exceeding 50 watts, service value ≥ 6.0, noise level ≤ 60 dB, insulation class ‘B’ and insulation resistance > 2 MΩ. Fan shall be of approved make such as Usha / Havells / Crompton / Orient or equivalent, including installation, online RPM verification, testing, commissioning and handing over to the Engineer-in-Charge, with minimum 2-year manufacturer warranty.
Supplying and fixing ISI-marked 6 A, 250 V modular step-type electronic fan regulator (2 Module), conforming to IS:3854 or latest IS standards, mounted on suitable modular plate with GI flush box, including wiring connections, testing and commissioning, of approved make such as Anchor Roma / Legrand / Schneider / Havells, complete as per direction of the Engineer-in-Charge.
Supply, Installation, Testing and Comm. Of 200/250mm sweep exhaust fan Shutter type of havell /Bajaj/ Crompton/equivalent make as directed by engineer incharge,Air Flow capacity >850cmph, 35-50Watts,Noise level 44db, 1200 rpm,water resistant, including making of space in wall/ window as per site requirement and necessary connections.The job includes replacement warranty of fixture if damaged/burn out what so ever reason for a period of two years reckoned from the date of sucessful commissioning / handing over of site to the intending department.(To be got approved before installation from EIC)
Supply, Installation, Testing and Commissioning of 100W (Havells/ PhillIps/Wipro skyline ) new generation energy saving and environmental friendly long life L.E.D Flood Light made up of pressure die cast Aluminum housing with high efficiency LEDs as lighting source with efficacy >110lm/w ,CRI>80 ,CCT>5000 ,Avg Life L70 50000 hours ,No haremful UV and IR radiators, Operating Temp -10°C to +45°C ,Surge Voltage Protection, IP66 Protection and impact resistance of IK07.The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch connections etc. as required.( Anchor roma plus/Legrand Mylinc /SSK/Schneider Zencelo /Crabtree athena make).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 No. 3 pin 5/6 A modular socket outlet and 5/6 A modular switch connections etc. as required.( Anchor roma plus/Legrand Mylinc /SSK/Schneider Zencelo /Crabtree athena make).
Wiring for AC/Power plug points (15/16A heating points) with 2x4 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit along with 1x4 sq. mm FRLS PVC insulated copper conductor single core cable for earthing, etc. as required.(Havells/ Polycab/ Anchor/ SSK) including the cost of conduit.
Wiring for 5-10A socket out lets for computer with 2X2.5 sq. mm FRLS PVC insulated copper conductor (Havells/ Polycab/ Anchor/ SSK) as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit, alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for earthing etc. as required including the cost of conduit.
Supplying and fixing of indicators on existing modular plate and switch box , incl. connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or equivalent).
Supplying and fixing modular blanking plate on the existing modular plate switch box excluding modular plate as recquired.
Supply and fixing of 6 way (4+18), Double door surface/ recess mounting, Horizontal type,three pole and neutral, sheet steel, MCB distribution board ,415V, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer. (Havells/Legrand/SSK/Schnider/ABB)
Supply, installation, testing and commissloning of 5-32A single pole rating 240/415V, 10 KA "C" curve MCB of Legrand/ Havells/ L&T/ABB suitable for inductive load in the MCB distribution board complete with necessary connections.
Supply, installation, testing and commissioning of 40A-32A DP rating 240/415V,10 KA "C" curve MCB of Legrand/ Havells/L&T/ABB suitable for inductive load in the MCB distribution board complete with necessary connections.
Supply, installation, testing and commissioning of 63A DP rating 240/415V,10 KA "C" curve MCB of Legrand/ Havells/ L&T/ABB suitable for inductive load in the MCB distribution board complete with necessary connections.
Main Panel Design, fabrication, supply, installation, testing, and commissioning of Main Distribution Board (MDB), duly manufactured from CPRI-approved manufacturer, made out of 12 SWG CRCA (IS 375) mild steel sheet, 2 mm thick, powder-coated with RAL 7035, floor/wall-mounted, vermin and dust-proof, indoor type. The panel shall be provided with suitable size angle iron legs for grouting in the ground, lockable hinged doors, and painted finish. The enclosure shall have provisions for fixing switchgears,Aluminium bus bars of various ratings (considering derating factor), and other allied accessories as required. The panel shall be fabricated as per approved design; size may vary according to site requirements. The panel shall fully comply with IS 8623 / IEC 61439 standards for low voltage switchgear assemblies.The work includes all internal wiring, thimbles, ferrules, nuts, bolts, washers, gland plates, earthing lugs, insulation sleeves and all other accessories necessary to complete the panel in all respects as per site requirements.”
Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required. 1. Incoming: a)200A 4P MCCB 36 KA Havells/Legrand/ Schinider/ABB/L&T sample to be approved before installation.
b) 4 No. of Aluminium Bus Bar of 300 Amp.
c)Digital meters and phase indicators -1 set.
d)Onload changeover Switch 100A for generator front operated
e) 4 No. of Aluminium Bus Bar of 200 Amp.
f)Digital meters and phase indicators -1 set.
2.Outgoing a)125A 4P MCCB 36 KA Havells/Legrand/ Schinider/ABB/L&T sample to be approved before installation.
b) 4 No. of Aluminium Bus Bar of 200 Amp.
c)100A 4P MCCB 25 KA Havells/Legrand/ Schinider/ABB/L&T sample to be approved before installation.
d) 4 No. of Aluminium Bus Bar of 200 Amp.
3.INVERTER a) 32A DP MCB 10KA
b) 2 No. of Aluminium Bus Bar of 63 Amp.
c) Digital meter and phase indicators 01 set.
Wiring for Circuit/Sub mains along with earth wire in FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires in recessed or surface conduiting system, including the cost of conduit. (Havells/ Polycab/ Finolex/ Anchor/KEI/RR or equivalent). 2x10 sq mm +1x6 sq mm Heating submain
2x 6 sq mm + 1x 6 sq mm Lighting submain
2x 4 sq mm + 1x 4 sq mm Inverter submain
2x 2.5 sq mm + 1x 2.5 sq mm inverter & normal Circuit
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.Complete Job.
Providing and laying earth connection from earth electrode with 8 mm dia copper wire in 15 mm dia G.l. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Supplying,Laying and fixing of Suitable Fan Junction Box in Slab.sample to be approved by EIC
Providing and fixing of Deep boxes for lights in Slab,sample to be approved by EIC
Supply, laying, connecting and commissioning of 50 sq mm 4 core XLPE/ PVC Insulated and steel armored 1.1 KV grade Aluminum LT cable for Service line, incl. cost of required al. thimbles duly crimped. (Over head/ under ground).
Supplying and laying of 90 mm dia (OD-90 mm & ID-76 mm nominal) size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
Supply, installation, testing and commissioning of 60 kVA three-phase unbalanced type servo voltage stabilizer conforming to IS:9815 and relevant IS standards, suitable for unbalanced load conditions, with input voltage range 90–265 V AC (P-N) / 156–460 V AC (P-P), output 415 V ±1%, 50 Hz, 3-phase 4-wire, efficiency ≥98% at full load, oil-cooled, copper-wound transformer on CRGO laminations, capable of 15% overload for 4 hours, zero waveform distortion, voltage correction speed 8–20 V/sec, equipped with automatic protections for under/over voltage, overload, single phasing, phase reversal, including digital voltmeter, ammeter, phase sequence indicator, LED indications and manual bypass arrangement, complete in all respects as per direction of Engineer-in-Charge.The equipment shall be supplied with manufacturer’s routine test certificate as per IS:9815 and relevant IS standards, and shall be subject to inspection and approval by Engineer-in-Charge before commissioning.The above item shall also include providing and fixing of 125A, 4 Pole, on-load manual bypass changeover switch,inside suitable MS enclosure suitable for bypassing the servo stabilizer, mounted on wall with proper interlocking and wiring, ensuring safe manual transfer between mains and stabilized supply.The Job also includes Two-year comprehensive warranty including repair and replacement of the servo stabilizer from the date of commissioning.
Supply, installation, testing and commissioning of 2000 VA (2 kVA), 12 V, single-phase pure sine wave inverter with inbuilt charger and automatic changeover, conforming to IS 16242/IEC standards, including supply of 2 Nos. 12 V, 220 Ah tall tubular lead-acid batteries (IS 13369/IS 1651) mounted on PVC/FRP battery trolley, complete with interconnecting cables, terminals, DC fuse/isolator, AC wiring to DB, initial charging, commissioning, and all accessories, duly approved by Engineer-in-Charge.
Providing, supplying and fixing ISI-marked 4.5 kg capacity CO₂ fire extinguisher, conforming to IS:15683, suitable for Class B and electrical fires, complete with high-pressure discharge hose, squeeze-grip control valve, self-indicating pressure gauge, and wall mounting bracket, of approved make such as Ceasefire / Safex / Minimax, including transportation, installation, demonstration and all accessories, complete as per direction of the Engineer-in-Charge.
Supply and erection of Mild Steel Swaged Tubular Pole conforming to IS: 2713-1980 (Part I & II), with base plate. The pole shall be manufactured from steel tubes and pipes as per IS:1141 (Fe 410), including excavation of pit and refilling with M-15 grade cement concrete (1:2:4 mix) from base plate up to 50 cm above ground level. The pole shall include earthing terminal and cable entry through 32 mm dia B-class GI sleeves. The pole shall be painted with two coats of red oxide primer and two coats of silver enamel paint. The job includes the cost of formwork and carriage of all required materials. (9 mtr., 410 SP-28).
Providing and fixing of detachable type round or square bracket, suitable for up to 6 light fittings, fabricated from 32/35 mm diameter GI pipe, including cutting, bending, and necessary welding to form uniform arms, with proper support and fixing arrangements as required. Complete job including priming, painting, and installation as per directions of the Engineer-in-Charge.
Providing and fixing of IK08, IP66, 120W protected high-power LED flood light system, with a single-piece pressure die-cast aluminum housing and toughened glass diffuser with suitable lenses on LEDs, to achieve various beam angles of high-power LEDs of 3 to 5 watts each. Integrated potted driver, as a unique BIS R number, having more than 85% and in compliance to BIS certified and Trade Mark certificate. The system-level luminaire efficacy shall be ≥ 110 lm/W. LED driver input voltage AC 120V to 270V with high-voltage cut-off. The driver shall have auto-resetting safety, power factor > 0.95, THD < 10%, and driver current ≤ 750 mA. The driver shall be capable of phase-to-phase protection up to 440V for 4 hours. Electrical connector, surge protection minimum 24 kV internal and 10 kV external, built inside the driver compartment. System life of 50,000 burning hours with 70% of initial lumens maintained, CRI ≥ 70 and CCT 5700K ± 355K. Manufacturer’s word mark/name shall be engraved/embossed/screen-printed on die-cast housing to allow traceability/authenticity. Fixture shall be IS 10322 compliant. OEM must have its own in-house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate/report with liable warranty of product/accessories from OEM shall be submitted.
S/L, testing and commissioning of, 16 sq. mm 2 core XLPE Insulated, PVC aluminum armored cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments. Havells or Eq. standard make as directed by engineer Incharge and making end termination with brass compression gland and aluminum lugs of reqd size.
Supplying and laying of 63 mm dia (OD-63 mm & ID-51 mm nominal) size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
Supply, installation, testing and commissioning of floor-mounted, compartmentalized outdoor-type main distribution panel, fabricated from 16-gauge sheet steel, complete with 4 Nos. angle iron legs, waterproof, dustproof, duly painted and provided with earth terminal and all necessary internal wiring and accessories. The panel shall be equipped with the following switchgear and control devices: 1.NORMAL INCOMING 100A DP MCB 10KA 01 no. 200A SP&N bus bar AL. Strips 01 set Digital meter and phase indicators 01 set. Space for 08 way MCBs The panel should have a compartmental space for housing a 4 KVA voltage stabilizer. The job includes providing and laying of M15 grade cement concrete pedastal block (size 2’-0” × 3’-0” × 1’-6”), including formwork, curing, finishing and carriage of all required materials, as per directions of Engineer-in-Charge.
Supplying and drawing FRLS PVC insulated copper conductor single core cable through pole up to light inside flexible pipe conduit. 3 x 2.5 sq. mm (P + N+Loop Earth)
Providing and fixing/ laying of earthing station by way of placing GI electrode rod/ pipe in a pit , connected through GI strip. (complete job)
Providing and fixing of IP 65 proct impact resistant polycarbonate enclosure box with knock out for cable entry /out including fixing with nut bolt fastner etc required complete in all respect of following size along with 63 A connector and 3 no. 6A MCB for controlling the High Mast Lights.
Supply, installation, testing and commissioning of 4 kVA automatic relay-type Voltage Stabilizer suitable for 1.5 Ton Split Air Conditioner, designed to operate on wide input voltage range of 90–260V and deliver stabilized output of 230V ±3%, complete with low/high voltage cut-off protection, time delay feature, wall/floor mounting arrangement, indicator lamps for input/output status, necessary wiring connections and fixing hardware, including testing and demonstration at site. The stabilizer shall be ISI-marked and of approved make. (Approved Make: V-Guard / Servokon / Microtek / Bluebird / Everest / equivalent), and sample shall be approved by the Engineer-in-Charge before installation.
Providing of chemical earthing as per IS standards by way of digging 8 feet pit then embedding 3 mtr. Long GI earthing electrode, 80 mm dia. Connecting the plate with main control board by 10 SWG Copper wire with 1/2” dia. Full thread brass nut and bolts and washers, refilling the pit with chemical compound.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.32 MB
BOQ_979733.xls
BOQ • 0.55 MB
NIT194SBD.pdf
Additional Documents • 2.46 MB
Download all tender documents and submit your bid