Loading
Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹37.5 L
Closing Date
15 Jun 2023, 3:00 pmClosed
PR & CC
Digitally signed and encrypted bids under two bid systems are invited for carrying out TERMINAL
23000040-HD-10120
23000040-HD-10120
Open Tender
Raipur, Chhattisgarh
₹0
₹37.5 L
15 Jun 2023
25 May 2023
15 Jun 2023
15 Jun 2023
25 May 2023 - 2 Jun 2023
| Item No | Item Title | Description | Qty | Unit |
|---|---|---|---|---|
| 1 | Supply - 3" MFM with 4" proces | Supply - 3" MFM with 4" proces — FLOWMETER,MASS,CORIOLIS; SIZE,FLANGE:4 IN; PRESSURE DESIGN,FLANGE:CLASS 150; FLANGE,TYPE:RAISED FACE; MAT,FLANGE(S):STAINLESS STEEL 316; MOUNTING,TRANSMITTER:REMOTE; CLASSIFICATION,HAZARD AREAS:ZONE 1, GROUP II A AND B T3; INGRESS PROTECTION:IP65, IEC/EN60529; COMMUNICATION-PROTOCOL:MODBUS; CONNECTION,ELECTRICAL:1/2 IN NPT FEMALE; POWER SUPPLY:230 VAC/24 VDC, 50 HZ; PRESSURE LIMIT:1/10 KG/CM2; TEMPERATURE LIMIT:0 TO 50 DEG C; RANGE,INSTRUMENT:(MIN/NORM/MAX):200/2000/2400 LPM; MFM SIZE:3 INCH, MFM FOR WHITE OIL, SERVICE:TO MEASURE VOLUMETRIC FLOW ON BATCHING APPLICATIONS FOR CUSTODY TRANSFER OF BLACK OIL,OPERATING DENSITY:REFER DESIGN CRITERIA, OPERATING VISCOSITY:REFER DESIGN CRITERIA, ALLOWABLE PRESSURE DROP(MIN/MAX):0.65 KG/CM2 AT 2000 LPM, FOR ALL MFMS, NO DEVIATION SHALL BE ACCEPTED ON THE MAXIMUM ALLOWABLE PRESSURE DROP CALCULATED AT THE GIVEN MAXIMUM LPM, RELATIVE HUMIDITY LIMIT:95 % NON-CONDENSING, TYPE:MICROPROCESSOR BASED CORIOLIS MASS FLOW AND DENSITY TRANSMITTER FOR CUSTODY TRANSFER APPLICATION, SENSOR TUBE MATERIAL:STAINLESS STEEL 316/STAINLESS STEEL 904L, WETTED PARTS:STAINLESS STEEL 316/STAINLESS STEEL 904L, FLOW DIRECTION:BI DIRECTIONAL, TUBE SIZE (SENSOR):TO BE SIZED BY VENDOR, OUTPUT:FLOW (MASS AND VOLUME), STANDARD (OPTIONAL) AND AMBIENT DENSITY, TEMPERATURE, BODY MATERIAL,TRANSMITTER:STAINLESS STEEL 304/DIE CAST ALUMINIUM, PROCESS CONNECTION:4 INCH RAISED FACE, ANSI CLASS 150, ASME B16.5 (AS PER SITE CONDITION), MATCHING FLANGE:REQUIRED, MOUNTING ACCESSORIES:REQUIRED, ACCURACY,MASS:+0.05 % FOR THE ENTIRE FLOW RANGE, VOLUME:+0.1 % FOR THE ENTIRE FLOW RANGE, DENSITY:+0.0005 GM/CC, LINEARITY:+/- 0.05 % OF THE READING, REPEATABILITY:+/-0.05 % FOR THE ENTIRE FLOW RANGE AND +0.00025 GM/CC FOR DENSITY, LOCAL DISPLAY:2 LINE, 16 CHARACTERS, SCROLL-TOUCH SCREEN PREFERRED DATA TO BE DISPLAYED VOLUME FLOW MASS FLOW, TEMPERATURE, VOLUME TOTALIZER, DENSITY AT AMBIENT TEMPERATURE, DENSITY AT 15 DEG C (OPTIONAL), DOUBLE COMPRESSION TYPE, OUTPUT:1.FREQUENCY:10000 HZ FOR FLOW RATE TO BE CONNECTED TO BATCH CONTROLLER, 2.RS 485 MODBUS FOR DATA TRANSFER OF MEASURE VARIABLES TO CLIENTS TAS. THE ABOVE FEW OR ALL MAY BE REQUIRED TO BE INTEGRATED TO EXISTING BATCH CONTROLLER, CUSTODY TRANSFER APPROVAL:YES (PTB/NMI)–OIML R117, W AND M LOCK:PROVISION FOR LOCK OF TRANSMITTER. SOFTWARE AS WELL AS HARDWARE SHALL BE PROVIDED, K FACTOR:ANY CHANGE IN METER/K FACTOR SHALL BE RECORDED IN THE TAS SYSTEM. SUITABLE OUTPUT FROM THE METER SHALL BE PROVIDED FOR THE SAME, CONNECTIVITY:THE FREQUENCY OUTPUT OF THE FLOW METER SHALL BE TAKEN TO BATCH CONTROLLER. MAXIMUM OF 4 MASS FLOW METERS SHALL BE MULTI-DROPPED OVER RS 485 MODBUS AND TAKEN TO THE CONTROL ROOM FOR DISPLAY OF DENSITY, TEMPERATURE AND FLOW RATE, HOUSING PROTECTION:WEATHER PROOF TO IP65 AND EXPLOSION PROOF, APPROVAL:CCOE/PESO AND CMRI, CALIBRATION:APART FROM SITE CALIBRATION, ALL THE MFMS SHALL BE CALIBRATED AT FACILITIES APPROVED BY REPUTED NATIONAL/INTERNATIONAL AUTHORITIES LIKE PTB/NMI/NABL ACCREDITED, PRIOR TO DISPATCH TO LOCATION. THE CALIBRATION RIG ACCURACY SHALL BE AT LEAST 2 TIMES BETTER THAN THE ACCURACY OF THE MASS FLOW-METERS | - | Set |
| 2 | Erect & comm of 4" MFM | Erect & comm of 4" MFM — ERECTION OF MASS FLOW METER: ERECTION OF MASS FLOW METER IN TT LOADING GANTRY FOR WHITE OIL MEETING THE REQUIREMENT OF HPCL ENGINEER-IN-CHARGE. | - | Each |
| 3 | Supply - 4" SAE with DPG | Supply - 4" SAE with DPG — STRAINER,PIPE,Y-TYPE,FLANGED; TYPE:AIR ELIMINATOR; MATERIAL:STAINLESS STEEL 304; MAT SPEC,BODY:N/A; MAT SPEC,SCREEN:N/A; MESH,SIZE:40; FACING,FLANGE:RAISED FACE; PRESSURE DESIGNATION:CLASS 150; SIZE:100 MM; WITH DPG FOR WHITE OIL | - | Each |
| 4 | Erect & comm of 4" SAE | Erect & comm of 4" SAE — ERECTION OF ABOVE STRAINER CUM AIR ELIMINATOR AS PER APPROVED DRAWING. SCOPE INCLUDES DISMANTLING OF OLD ITEMS AND STORAGE OF SAME AS PER INSTRUCTION OF SITE IN CHARGE. | - | Set |
| 5 | Sup 4 in DCV white oil | Sup 4 in DCV white oil — VALVE,CONTROL; MANUFACTURER:N/A; MODEL:N/A; TYPE:DIAPHRAGM,DIGITAL; MAT SPEC,BODY:N/A; PRESSURE DESIGNATION:1500 LPM; SPEC,LEAKAGE:N/A; TYPE,ACTUATOR:N/A; PRESSURE,AIR SUPPLY:N/A; SERVICE:N/A; FLOW COEFFICIENT (CV):N/A; SIZE:75 MM; EXPLOSION PROOF CLASS 1, GROUP II A AND II B, T3 AND WEATHER PROOF TO IP65 AND AS PER TENDER SPECIFICATIONS AND APPROVED DATASHEETS FOR WHITE OIL. | - | Each |
| 6 | Erect & comm of 4" DCV | Erect & comm of 4" DCV — ERECTION OF 3 INCH DIRECTIONAL CONTROL VALVES AS PER APPROVED INSTALLATION DRAWING. SCOPE INCLUDES DISMANTLING OF OLD ITEMS AND STORAGE OF SAME AS PER INSTRUCTION OF SITE IN CHARGE. | - | Each |
| 7 | Supply - 2" MFM for Ethanol | Supply - 2" MFM for Ethanol — FLOWMETER,MASS,CORIOLIS; SIZE,FLANGE:2 IN; PRESSURE DESIGN,FLANGE:CLASS 150; FLANGE,TYPE:RAISED FACE; MAT,FLANGE(S):STAINLESS STEEL 316; MOUNTING,TRANSMITTER:REMOTE; CLASSIFICATION,HAZARD AREAS:ZONE 1, GROUP II A AND B T3; INGRESS PROTECTION:IP65, IEC/EN60529; COMMUNICATION-PROTOCOL:MODBUS; CONNECTION,ELECTRICAL:1/2 IN NPT FEMALE; POWER SUPPLY:230 VAC/24 VDC, 50 HZ; PRESSURE LIMIT:1/10 KG/CM2; TEMPERATURE LIMIT:0 TO 50 DEG C; RANGE,INSTRUMENT:MIN/NORM/MAX:30/500 LPM; MFM SIZE:1.5 INCH, MFM FOR WHITE OIL, SERVICE:TO MEASURE VOLUMETRIC FLOW ON BATCHING APPLICATIONS FOR CUSTODY TRANSFER OF BLACK OIL, OPERATING DENSITY:REFER DESIGN CRITERIA, OPERATING VISCOSITY:REFER DESIGN CRITERIA, ALLOWABLE PRESSURE DROP(MIN/MAX):0.5 KG/CM2 AT 500 LPM, FOR ALL MFMS, NO DEVIATION SHALL BE ACCEPTED ON THE MAXIMUM ALLOWABLE PRESSURE DROP CALCULATED AT THE GIVEN MAXIMUM LPM, RELATIVE HUMIDITY LIMIT:95 % NON-CONDENSING, TYPE:MICROPROCESSOR BASED CORIOLIS MASS FLOW AND DENSITY TRANSMITTER FOR CUSTODY TRANSFER APPLICATION, SENSOR TUBE MATERIAL:STAINLESS STEEL 316/STAINLESS STEEL 904L, WETTED PARTS:STAINLESS STEEL 316/STAINLESS STEEL 904L, FLOW DIRECTION:BI DIRECTIONAL, TUBE SIZE (SENSOR):TO BE SIZED BY VENDOR, OUTPUT:FLOW (MASS AND VOLUME), STANDARD (OPTIONAL) AND AMBIENT DENSITY, TEMPERATURE, BODY MATERIAL,TRANSMITTER:STAINLESS STEEL 304/DIE CAST ALUMINIUM, PROCESS CONNECTION:2 INCH RAISED FACE, ANSI CLASS 150, ASME B16.5 (AS PER SITE CONDITION), MATCHING FLANGE:REQUIRED, MOUNTING ACCESSORIES:REQUIRED, ACCURACY,MASS:+0.05 % FOR THE ENTIRE FLOW RANGE, VOLUME:+0.1 % FOR THE ENTIRE FLOW RANGE, DENSITY:+0.0005 GM/CC, LINEARITY:+/- 0.05 % OF THE READING, REPEATABILITY:+/-0.05 % FOR THE ENTIRE FLOW RANGE AND +0.00025 GM/CC FOR DENSITY, LOCAL DISPLAY:2 LINE, 16 CHARACTERS, SCROLL-TOUCH SCREEN PREFERRED DATA TO BE DISPLAYED VOLUME FLOW MASS FLOW, TEMPERATURE, VOLUME TOTALIZER, DENSITY AT AMBIENT TEMPERATURE, DENSITY AT 15 DEG C (OPTIONAL), DOUBLE COMPRESSION TYPE, OUTPUT: 1.FREQUENCY:10000 HZ FOR FLOW RATE TO BE CONNECTED TO BATCH CONTROLLER, 2.RS 485 MODBUS FOR DATA TRANSFER OF MEASURE VARIABLES TO CLIENTS TAS. THE ABOVE FEW OR ALL MAY BE REQUIRED TO BE INTEGRATED TO EXISTING BATCH CONTROLLER, CUSTODY TRANSFER APPROVAL:YES (PTB/NMI)–OIML R117, W AND M LOCK:PROVISION FOR LOCK OF TRANSMITTER. SOFTWARE AS WELL AS HARDWARE SHALL BE PROVIDED, K FACTOR:ANY CHANGE IN METER/K FACTOR SHALL BE RECORDED IN THE TAS SYSTEM. SUITABLE OUTPUT FROM THE METER SHALL BE PROVIDED FOR THE SAME, CONNECTIVITY:THE FREQUENCY OUTPUT OF THE FLOW METER SHALL BE TAKEN TO BATCH CONTROLLER. MAXIMUM OF 4 MASS FLOW METERS SHALL BE MULTI-DROPPED OVER RS 485 MODBUS AND TAKEN TO THE CONTROL ROOM FOR DISPLAY OF DENSITY, TEMPERATURE AND FLOW RATE, HOUSING PROTECTION:WEATHER PROOF TO IP65 AND EXPLOSION PROOF, APPROVAL:CCOE/PESO AND CMRI, CALIBRATION:APART FROM SITE CALIBRATION, ALL THE MFMS SHALL BE CALIBRATED AT FACILITIES APPROVED BY REPUTED NATIONAL/INTERNATIONAL AUTHORITIES LIKE PTB/NMI/NABL ACCREDITED, PRIOR TO DISPATCH TO LOCATION. THE CALIBRATION RIG ACCURACY SHALL BE AT LEAST 2 TIMES BETTER THAN THE ACCURACY OF THE MASS FLOW-METERS | - | Set |
| 8 | Erect & comm of 2" MFM | Erect & comm of 2" MFM — INSTALLATION OF 2 INCH MASS FLOW METER AT NEW LOCATION BENEATH THE PLATFORM, JOB INCLUDES SHIFTING OF 2 INCH MASS FLOW METER FROM STACKED AREA A WITHIN THE HPCL PREMISES, PROVIDING ALL REQUIRED NON SPARKING TOOLS AND TACKLES ETC, AS PER REQUIREMENTS TO COMPLETE THE WORK IN ALL RESPECTS AS PER INSTRUCTIONS OF ENGINEER IN CHARGE, ADEQUATE CARE SHALL BE TAKEN BY THE CONTRACTOR NOT TO DAMAGE THE EXISTING EQUIPMENT/PIPING SYSTEM WHILE DISMANTLING, THE CONTRACTOR SHALL RECTIFY ANY DAMAGE CAUSED WITHOUT ANY IMPLICATION TO THE OWNER, JOB ALSO INCLUDING SUPPLY OF SPIRAL WOUND GASKETS, STUD AND BOLTS AS PER THE TECHNICAL SPECIFICATION. | - | Each |
| 9 | Sup 2"DCV-Ethanol | Sup 2"DCV-Ethanol — SUP 2 IN DIAPHRAGM TYPE SET STOP VALVE FOR ETHANOL AND BIODIESEL MIN FLOW 30 MAX FLOW 500 | - | Each |
| 10 | Erect & comm of 2" DCV | Erect & comm of 2" DCV — ERECTION OF 3 INCH DIRECTIONAL CONTROL VALVES AS PER APPROVED INSTALLATION DRAWING. SCOPE INCLUDES DISMANTLING OF OLD ITEMS AND STORAGE OF SAME AS PER INSTRUCTION OF SITE IN CHARGE. | - | Each |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.