Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹69.8 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹73.6 L+₹3.7 L (5.36%)Rejected-Finance 443 V P O PUTHI 131301 | PUTHI | SONIPAT | HARYANA | 131301 | L2 | Rejected-Finance Rejected due to high rate. | |
| 3 | L3₹84.7 L+₹14.9 L (21.4%)Rejected-Finance GHARCHE | L3 | Rejected-Finance Rejected due to high rate. | |
| 4 | Not Admitted-Fee/PreQual/Technical BATHINDA | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
31 Dec 2024, 11:00 amClosed
Executive Engineer,
Executive Engineer, Bathinda Canal and Ground Water Division, Bathinda
Renovation of Canal Rest House, Virk Kallan
2024_WR_131169_7
32/22A/2024-25
Open Tender
Civil Works
Item Rate
Bathinda
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,000
₹80,000
Bathinda
20 Jan 2025
5 Dec 2024
31 Dec 2024
5 Dec 2024
31 Dec 2024
5 Dec 2024
13 Dec 2024
Amount
12.5 mm thick cement plaster 1:4
Plastering on underside of ceiling 10mm thick cement plaster 1:4
Scraping Lime Plaster
Providing and fixing chicken mesh for brick work and RCC junction of galvanized low carbon wire, annealed wire of diametre 0.6 to 2.0mm distance between the faces of the hexagon 13 to 50mm complete in all respact
Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. Doors of area 3 sqm and below
Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. Windows of area 3 sqm and below
First class burnt brick work laid in cement sand mortar 1:3 in first storey upto 4 metres above plinth level
Dismantling brick or flagged stone flooring without concrete base
Cement rendering on plaster 1mm thick
Laying of dry brick ballast 40mm gauge for flooring
Providing and laying vitrified floor tiles ofdifferent sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption`sless than 0.08% and confirming to IS:15622of approved make in all colours ans shade, laid on 20mm thick cement mortar 1:4,complete Size 800x800mm
Grouting the joints of flooring tiles having joints of 3mm width, using epoxy grout mix of 0.70kg of organic coated filler of desired shade(0.10 kg of hardner and 0.20 kg of resin per kg) i/c filling/grouting and finishing complete as per directionof Engineer-in-charge. Size 800x800mm
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly gloss finish/Highter/emboss conforming to IS 15622 thickness to be specified by the manufacture of approved make in all colours,shades except burgundy , bottle green,black of size 600 x600mm as approved by engineer - in -charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:4 and jointing with grey cement slurry @33kg per sqm i/c pointing in white cement mixed with pigment of matching shade complete
Preparation of plastered or concrete surfaces for painting (i/c sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67litre/10sqm over and i/c base coat of water proofing cement paint applied @2.2kg/10sqm
Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade( two or more coats)
Recessed PVC conduit pipe wiring system with modular switches Wiring in pvc insulated copper conductor single core FR cable ISI marked overall 1.5sq.mm, 1100 volts grade to be laid in heavy gauge pvc conduit pipe 20mm/25mm dia. ISI marked recessed in wall etc., complete with powder coated/anodized concealed metal boxes(1.6mm thick with brass lugs) required for suitable no of modules for having step type electronic fan regulators (two modules) 100watts, bell push, 6amp 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc and covered with frame plate etc. PVC connector (for fan box Bell), steel Hooks, sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes(four way PVC 1.5" deep for walls and CI 3" deep for ceiling), bonding to earth with pvc insulated copper conductor single core FR cable ISI marked 1sq.mm., 1100 volts grade(for 6amp wall socket and plug control point) and other petty material etc. i/c the cost of above material, cutting and filling up of chases(with finishing the surfaces):- (1) Wiring fan point (w/o fan box)
Wiring light point
Wiring call-bell point
Wiring 6Amp. Wall socket point
Wiring 16/20Amp. Powerplug control point
Recessed AC Supply Terminal Point(Used for HGW, PVC Conduit and HDPE Pipe Wiring System With modular accessories): Wiring AC supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable no of modules for having 25Amp. Combined/ universal socket(Shuttered) and modular motor startar 25 Amp. (2Modules), covered with frame plate and other petty material etc. i/c the cost of above material, cutting and filling up of chases(with finishing the surfaces):-
Wiring AC supply terminal pointhaving 1no. 25amp universal socket (shuttered) erected at AC height and 1 no. motor startar 25Amp. Erected at switch board light.
Recessed Computer Supply Terminal Points (Used for HGW, PVC Conduit and HDPE pipe wiring system with modular accessories): Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable no of modules for having 6Amp. 2/3 universal socket (shuttered), 16/20 Amp. Combined/ universal socket(shuttered), 3/10/16/20Amp. awitches and blanking plate etc., and covered with frame plate and other petty material etc. i/c the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring computer terminal point having 3 nos. 6Amp. 2/3 universal socket(shuttered), 1no. 16/20Amp. Universal socket (shuttered), 2nos. 16/20 Amp. Switches with indicator and 2 nos. blanking plate
Supply and erection of TV socket, Telephone socket and networking socket point inpowder coated/anodized concealed metal boxes recessed in wall reqd. for suitable no of modules for having TV sockets, Telephone socket RJ11 and networking socket RJ45 one module, covered with frame plate and petty material etc. i/c the cost of above material, cutting and filling up of chases (with finishing the surfaces);- (1) Wiring Telephone socket point RJ11 (one module)
PVC insulated FR copper conductor cables:Supply and erection of PVC insulated FR single core unsheathed copper conductor cable Isi marked suitable upto 1100 volts grade confirmto IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the engineer-in-charge:- (ii) Overall size 2.5sq.mm (un-sheated)
Overall size 4.0sq.mm (un-sheated)
PVC, HDPE pipes and PVC Flexible Pipes:
PVC, HDPE pipes and PVC Flexible Pipes: Supply and erection of PVC conduit pipes ISI marked as per IS 9537:part III and HDPE pipes ISI marked as per IS4984:1995 for wiring purposes i/c bends, junction boxes, steel hooks, M.S. saddle clamps and other petty materials rtc., as per pwd general specifications:- (1) Medium Gauge PVC conduit Pipe 25mm dia. (flushed)
Heavy Gauge PVC conduit pipe 32mm dia. (flushed)
Miniature Circuit Breaker: Supply and erection of MCB`s for circuit protection against overload and short circuit current fault suitable for 240/415 volts 50cycles AC supply with breaking capacity of 10Ka Curve c and low watt losess as per IS/IEC 60898-1, energy limitation class-3, true contact indication, labelholder facility inthe existing MCB distribution board as per PWD general Specifications i/c connections with suitable sizes of thimbles/lugs:- (1) MCB single pole 6-32amp. (10ka, curve-c)
MCB double pole 50,63 amp. (10ka, curve-c)
Sheet Metal Double Door Distribution Board For MCB`s/RCBO`s/RCCB`s: Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door as per IS 8623-1&3,IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, eath bars, cement spill protector, color coded interconnecting wire set, cable ties, blanking plates and circuit indentifications label and of reqd. no of ways for mounting MCB`s/RCBO`s/RCCB`s in the distribution board asper PWD General specifications i/c connections with suitable sizes of timbles and bonding to existing eartg etc:-
SP&N Double Door Distribution Board 12 way each
Wiring overhead line in PVC insulated and PVC sheathed two single core aluminium conductor cable overall 1100 volts grade binding with G.I. wire 2mm dia.(14SWG) with brass/aluminium link clips complete inall respect as approved and desired by the engineer-in-charge ar site.
PVC insulted & PVC sheated aluminium conductor cable overall Size 10mm2 (1/1.40mm) Twin core
Laying of under ground cables, dismantling and erection of poles and cement concrete muffs: Laying of under ground cable to be laid 1 m below ground level i/c excavation, sand cushioning, covering with sand and first class bricks and back filling the trench etc.
Sail wood chowkats i/c iron hold fasts iron hinges corner straps clears, stops wooden knobs fixed in position. (1) Double Rebate (60mm x 150mm)
Single Rebate (60mm x 60mm)
Red meranti Normal Super (18 to 19 kg per cft approx.) doors shutter windows shutter i/c hinges, screw and cords etc. complete fixed in position 35 mm thick
Wire gauge Red meranti wood super (18 to 19 kg per cft approx.) door shutter w/o springs housed in chowkats 35mm thick
Providing and fixing 6" stainless steel handles ISI marked on door and windows frame complete in all respect as per the directions of engineer in charge
Providing and fixing 8" stainless steel tower bolt ISI marked on door and windows frame complete in all respect as per the directions of engineer in charge
Curtain rod 25mm dia aluminium pipe with brackets fixed in position i/c nails and screws etc.(Deodar wood)
Tailoring of curtains
Dismentlling brick work tile,masonry or tile lining
Iron grated doors ,including pintle hinges and arrangement(Lumpsum)
Dismantling, disjointing, removal of G.I. pipe lines, specials, valves and fittings complete in all respects.
CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.
Providing and fixing in position Chinaware extended wall mounted E. W.C. type suite (size 66 x 46 x 77.5 cm ) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) with or without 10 ltr. chinaware matching flushing cistern and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.
Black granite stone tile 15mm to 20mm thick in skirting,risers of steps, dado walls and pillars laid in 12.5mm thich cement mortar 1:3 and jointed with neat cement slurry mixed with pigment to match the shade of stone,i/c rubbing and polishing i/c labour for fixing dowel pins and cramps
Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete
Earth work in excavation in foundation trenches etc in all kinds of siol where pick- jumoer work is not involved and not exceeding 2.0 meter depth including dressing of bottom and sides of trenches ,stacking etc.
Painting two or more coats with synthetic enamel paints in all shades on old wood work or metalic or plastered or concrete surface to give an even shade including rubbing down old paint
Applying pink primer or aluminium priming coat on wood work i/c preparation of surface knotting and stopping etc.
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
Earth work over Roofs with good earth free of any admixture of foreign matter including breaking of clods, ramming, watering, dressing and horizontal lead upto 30 metres.
Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16
Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3
Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Design is homogenous throughout the tile body Size 600 x 600 mm
Dismantling of brick work in cement sand mortar / lime mortar including T&P scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material. & staking the serviceable material with all lifts & lead of 100 metre (By Mechanical Means)
First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level.
First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
12.5 mm thick cement plaster 1:4
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in super structure
Providing and laying 60 mm thick factory made cement concrete interlocking paving blocks of M-35 grade manufactured by block making machine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRC SP 63-2014 and of approved size and design/shape laid in ordinary grey colour and pattern over and including 40 mm thick compactedbed of coarse sand, filling the joints with fine sand etc, all complete as per engineer-in-charge.
Cement concrete 1:8:16 With stone aggregates 20mm gauge mixing by mechanical means using concrete mixer volumetric type
MOHAN LAL (BID ID -608141)
SURINDER KUMAR CONTRACTOR (BID ID -608041)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .