Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.6 LAccepted-AOC | L1 | Accepted-AOC Lowest Bid | |
| 2 | L2₹19.1 L+₹22,230 (1.18%)Rejected-Finance 1 6 620 CHAITANYAPURI INDRA NAGAR DILSUKHNAGAR HYDERABAD TELANGANA 500060 UDYAM TS 09 0007870 37AAEPO0535A1Z8 B 36AAEPO0535A1ZA R MSME STATUS AS VERIFIED | RANGA REDDY | TELANGANA | 500060 | L2 | Rejected-Finance Being Not Lowest | |
| 3 | L3₹19.5 L+₹65,010 (3.44%)Rejected-Finance | L3 | Rejected-Finance Being Not Lowest | |
| 4 | L4₹19.8 L+₹93,317 (4.94%)Rejected-Finance | L4 | Rejected-Finance Being Not Lowest | |
| 5 | L5₹20.5 L+₹1.6 L (8.64%)Rejected-Finance | L5 | Rejected-Finance Being Not Lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
24 Jan 2022, 6:00 pmClosed
GE MCEME SECUNDERABAD
GE MCEME Secunderabad MCEME Campus, Trimulgherry (Post) Secunderabad - 500 015
REPAIRS AND REPLACEMENT OF UNSERVICEABLE ELECTRICAL WIRING EARTHING AND CONNECTED ITEMS OF MCEME UNDER GE MCEME SECUNDERABAD
2021_MES_497532_1
GE/MCEME/TOK/53 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SECUNDERABAD
Class E Category a(i) or b(i)
7 documents required · 7 mandatory
₹500
GE MCEME SECUNDERABAD
₹50,000
Yes
11 Feb 2022
27 Dec 2021
26 Jan 2022
27 Dec 2021
24 Jan 2022
11 Jan 2022
Amount
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / Hylam sheet/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes complete all as specified and directed. Note: Taking down for existing surface point wiring including removal of conduit.
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on conduit including Hylam sheet/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes complete all as specified and directed. Note: Taking down for existing concealed point wiring without removing conduit.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multistranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked of suitable dia, surface conduit wiring on walls including Tee, Junction boxes and provision of 2.0mm thick MS terminal boxes duly painted with red oxide metal primer and covered with 3 mm thick sheet cover of suitable size including suitable screws with washer for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to common earth dolly complete all as specified & as directed for One light point controlled by one, one way switch 5 amps, SP complete all as specified and directed. Note: For the wiring made concealed, cutting and chasing will be measured and paid seperately.
All as per item No. 3 above but for One Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator
All as per item No. 3 above but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
All as per item No. 3 above but for One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per item No. 3 above but for One light point controlled by two 2 - way switch 5 amps, SP
All as per item No. 3 above but for One Bell point controlled by one bell bush switch 5 amps, single pole
All as per item No. 3 above but using 4.0 Sqmm single core copper conductor cable multistranded PVC insulated unsheathed 1100 volts grade for 3 pin 15 Amps switch socket combination point including running 4.0 Sqmm copper conductor PVC wire as earth continuity conductor on independant board.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multistranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through any type of existing concealed/ existing surface conduit wiring and utilise the exiting MS terminal boxes duly painting reuqired with red oxide metal primer , covered with 3 mm thick sheet cover of suitable size including suitable screws with washer for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to common earth dolly complete all as specified & as directed for One light point controlled by one, one way switch 5 amps, SP complete all as specified and directed.
All as per item No. 10 above but for One Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator
All as per item No. 10 above but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
All as per item No. 10 above but for One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per item No. 10 above but for One light point controlled by two 2 - way switch 5 amps, SP
All as per item No. 10 above but for One Bell point controlled by one bell bush switch 5 amps, single pole
All as per item No. 10 above but using 4.0 Sqmm single core copper conductor cable multistranded PVC insulated unsheathed 1100 volts grade for 3 pin 15 Amps switch socket combination point including running 4.0 Sqmm copper conductor PVC wire as earth continuity conductor on independant board.
S & F Switch piano , single pole one way, flush type 5 Amps capacity 230 volts complete all as specified and directed.
S & F Switch piano , single pole two way, flush type 5 Amps capacity 230 volts complete all as specified and directed.
Supply and fixing bell push of 5 amps, single pole flush type complete all as specified and as directed.
Supply and fixing electric bell of 230 Volts AC single pole complete all as specified and as directed.
S & fixing switch socket combination 2 in 1 multipurpose 2/3 pin 5 amps flush type complete all as specified and directed.
S & fixing Socket outlet 3 pin, 5A, flush type complete all as specified and directed.
S & fixing switch socket combination 2 in 1 multipurpose 3pin 5/15 amps flush type complete all as specified and directed.
S & fixing electronic ceiling fan regulator stepped type heavy duty suitable to work on 230 volts complete all as specified and directed.
S& fixing lamp holder insulated body with black plate for angle/batten fittings fixed with round blocks complete all as specified and directed.
S & fixing ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65 x 50 mm complete all as specified and directed.
Supply and fixing capacitor 2.15 Mfd for ceiling fan complete all as specified and directed.
M & L Submain wiring on surface with 2 runs of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not not less than 25 mm dia including one run of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed.Note:-Two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured as one unit length. Note: For the concealed wiring made concealed, cutting and chasing will be measured and paid seperately.
M & L Submain wiring with 2 runs of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through existing conduit and conduit accessories including one run of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed.Note:-Two runs of cable and one run of earth contuinity conductor shall be measured as one unit length.
M & L Submain wiring on surface with 4 runs of single core 10 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not not less than 32 mm dia including two run of single core 10 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed.Note:-Four runs of cable, two run of earth contuinity conductor and one run of conduit shall be measured as one unit length. Note: For the wiring made concealed , cutting and chasing will be measured and paid seperately.
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of andings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
S &F Vertical type TPN DB 4 way double door for incoming MCCB TPN 415 volts AC 3 phase 50 Hz 16 KA, 125 Amps made out of CRCA sheet housing with powder coating complete all as specified and directed. Note: MCCB will be measured and paid seperately.
Supply and Fixing MCCB 415V,16KA, 4 pole, 125 amps suitable for VTPN DB all as specified and directed.
Supply and Fixing MCB DB double door TPN 4 way with 200 Amps busbar including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface complete all as specified and directed.
Supply and fixing MCB TPN, 63 Amps, C curve, 415 volts complete all as specified and directed
Supply and fixing MCB TP, 63 Amps, C curve, 415 volts complete all as specified and directed
Supply and fixing MCB double door DB SPN 8 way with 200 Amps busbar including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface complete all as specified and directed.
Supply and fixing MCB SPN 32 Amps C curve, 240 volts for fixing on MCB DB complete all as specified and directed.
Supply and fixing MCB SP 6 to 32 Amps C curve, 240 volts for fixing on MCB DB complete all as specified and directed.
S & F LED retrofit type polycarbonate lamp with integrated electronic drive of 18 Watt of 6500 K colour temp. complete all as specified and directed .
Supply and fixing ultra modern recess mounted 36W LED luminaire suitable for armstrong grid /POP ceiling of 2'x2' and complete including electronic driver including taking down old light fitting complete all as specified and directed.
Supply and fixing round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling /false ceiling including connecting up with three core flexible copper conductor cable of suitable size including taking sown old light fitting complete all as specified and directed.
Supply and fixing highbay LED luminair Energy saving, environment friendly & robust Highbay/Mediumbay LED IP65 luminaire with high efficacywith presssure die cast aluminium housing of capacity 150 W, with all accessories including necessary electrical connection and provision of 3 core multistranded coper conductor for electric connection of highbay light complete. Make : Havells Model No. SAUCERPLUSHBP150WLED85760DTOLTG or equivalent in Wipro, Bajaj, CG and Phillips /Luker/shakti fictures. NOTE :- Highbay light to be fixed at a hight of 15 meter approx
Supply and replace old unserviceable false ceiling fitting with ultra modern reces mounting 15/20 W LED luminaire suitable for armstrong surface type light of 1'x1' including electronic driver complete all as specified and directed.
M&L Copper strip 32x6 mm with saddles including insulators for every 1 m length and fixing screws etc. for down conductors above ground all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GI earth wire 4 mm dia drawn through and including GI protection pipe of light grade 15 mm bore by means of bolts, nuts, checknuts and washers all as shown in Electrical Plate No.3 of SSR Part-I and connected to main switch board including excavation and earth work, PCC chamber in 1:3:6, RCC Cover in 1:2:4 type B-1 reinforced, 20 mm dia medium grade GI pipe with funnel and wire mesh complete and watering arrangement all as specified. (Note: GI pipe 15mm dia, GI wire 4mm dia upto 7.5m deemed to be included in quoted rate.) complete all as specified and directed.
Ditto as per item no. 46 above but using copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead all as specified.
DPS sales and services india
gsrinivasarao
M/S Sekhar Infra Projects
M/S DIVIJA BUILDERS
BHEEMRAO PATIL CONTRACTOR
B AND H CONSTRUCTIONS
Srinivash Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .