| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC FLAT NO 601 TOWER NO 30 SECTOR NO 21 AMANORA PARK TOWN HADAPSAR PUNE 411028 | PUNE | MAHARASHTRA | 411028 | ₹18.5 L | L1 | Accepted-AOC THE LOWEST TENDERER |
| 2 | L2₹18.7 L+₹20,483.05 (1.11%)Rejected-Finance HOUSE NO 206 GAIKWAD ALI NEAR DATTA CHOWK MUNDHWA PUNE 411036 | PUNE | MAHARASHTRA | 411036 | ₹18.7 L+₹20,483.05 (1.11%) | L2 | Rejected-Finance NOT THE LOWEST TENDERER |
| 3 | L3₹23.4 L+₹4.9 L (26.4%)Rejected-Finance | ₹23.4 L+₹4.9 L (26.4%) | L3 | Rejected-Finance NOT THE LOWEST TENDERER |
| 4 | L4₹24.1 L+₹5.5 L (29.9%)Rejected-Finance | ₹24.1 L+₹5.5 L (29.9%) | L4 | Rejected-Finance NOT THE LOWEST TENDERER |
| 5 | L5₹28.2 L+₹9.7 L (52.4%)Rejected-Finance | ₹28.2 L+₹9.7 L (52.4%) | L5 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
Refer Docs
EMD Value
₹38,400
Closing Date
28 Sept 2024, 6:00 pmClosed
GE MH AND RH KHADKI
Military Engineer Services Garrison Engineer MH and Range Hills Range Hills Road Khadki, Pune 411003
PROVN OF COMPOUND WALL ALONG WITH INTERLOCKING TILES FOR OR INSTITUTE AT KLP HQ 41 ATRILLERY DIV AT WADGAON SHERI AND PROVN OF 60 ELECTRIC GEYSERS IN OTHER THAN MD ACCN OF JCO AND OR OLD GOVT MD ACCN OF 24 MARATHA LI UNDER GE MH AND RH KHADKI
2024_MES_668774_1
8595/E8
Open Tender
Civil Works
Item Rate
180 days
GE MH AND RH KHADKI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MH AND RH KHADKI
₹38,400
3 Nov 2024
31 Aug 2024
30 Sept 2024
31 Aug 2024
28 Sept 2024
14 Sept 2024
31 Aug 2024 - 21 Sept 2024
Amount
surface excavation n. exc 30 cm deep and averaging 15cm deep and getting out in any kind of soil complete all as specified and directed.
Excavation by mechanical means (Hydraulic excavator) over areas incl getting out & disposal of excavated n. exc 1.5 m deep and getting out in hard/ dense soil & disposal of excavated earth upto a lead of 50m and lift of 1.5m complete all as specified and directed.
M&L for removing excavated soil exceeding 250 m and not exceeding 500 m and depositing where directed at a level not exc 1.50m from starting point complete.
M&L for Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick watered and rammed to a true surface complete all as specified and directed.
M&L for plain cement concrete, type D2 1:4:8 (using 40mm graded stone aggregrates) in foundations, filling and mass-concrete complete all as specified and directed.
M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
M&L for providing plain cement concrete Type B1 1:2:4 (using 20mm aggreagates) in plinth courses, string courses, lacing courses, copings, kneelers, apex stones, bed plates, and the like including weathering, slightly rounded for chamfered angles and throating complete all as specified and directed.
M & L for Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), in all kinds of rocks including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m complete all as directed by Engr-In-Charge
M&L for plain cement concrete, type D2 1:4:8 (using 40mm graded stone aggregrates) in foundations, filling and mass-concrete complete all as specified and directed.
M & L for RCC M-25 (design mix) 20 mm graded aggregates for foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified and directed
M & L for RCC M-25 (design mix) (20 mm graded aggregates) for columns, pillars, piers, struts & posts complete all as specified and directed
M&L for RCC M-25 as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions finished even and fair complete all as specified and directed.
S&F for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M & L for mild steel bars 5mm dia and over upto and including 10mm dia, cut to length, bent to shape required, including cranking, in stirrups, spacers and binders, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and directed.
M&L rendering 5mm thick plaster in CM 1:4 over concrete surfaces finished even and fair complete all as specified and directed.
M&L for rendering 10mm thick in CM 1:6 on fair faces of brick wall surfaces finishing surfaces even and fair without using extra cement complete all as specified and directed.
M&L preparing newly plastered surface of wall and finishing walls with Acrylic Smooth exterior paint of required shade as in new work (two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed.
Providing precast cement concrete 1:2:4, type B0 louvres and jallies, 35mm thick (measured solid), including all mouldings but excluding frame set in CM 1:4 complete all as specified and directed.
Returning, filling in, including spreading, levelling watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and directed.
M&L for removing excavated soil exceeding 250 m and not exceeding 500 m and depositing where directed at a level not exc 1.50m from starting point complete.
M&L for cement concrete (type D-2 1:4:8) (40 mm grade aggregate) in foundations, fillings and mass concrete complete all as specified and directed
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed
Formwork to sides of pillars, posts, struts, piers, columns, and stanchions complete all as specified and directed
S & F for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed
M&L for preparing newly plastered surfaces and providing 3 coats of white wash complete all as specified and directed
M&L for preparing steel surfaces of any description, over 10cm in width or girth, not otherwise described and providing 2 coats of synthetic enamel paint over a coat of primer complete all as specified and directed
Supply and fix (Geyser) water heater storage type of capacity 25 Liters vertical type wall mounted including 15/16 Amps plug top with suitable wall supports and for manual operation, digital temperature display, feather touch buttons, built in thermostat, auto shut off, powder coated single line weld container with PUF insulation, heating element capacity of 2 KW, voltage rating 230 Volt, frequency 50 Hz, 5 star rated with and including steel braided connecting hoses of required length for Hot and cold water pipe, connecting to CPVC and GI pipe complete all as specified and directed by Engr-in-Charge. Make: Jaquar Cat part No MET-WHT-PV025 or equivalant in Crompton/ Bajaj. Note : (i) The rates are inclusive of all the minor spares, fittings and fixtures (Fasteners, Nut bolts washers etc) required for making the geyser fully functional. (ii) The rates are inclusive of charges of OEM of the geyer who has to visit the site and brief the user about the functioning of the water Heater.
M & L for point wiring complete with 2.5 Sqmm PVC insulated multistranded copper conductor cable including 2.5 sqmm PVC insulated but sheathed copper conductor FRLS cable 1100Volts grade and 2.5 sqmm as earth continuity conductor for one switch socket outlet 15 Amps on independent board drawn through concealed non metallic medium grade rigid PVC conduit of required size and accessories in surface of walls/ceilings etc complete all as specified and directed by Engr- in - Charge.
M&L for sub main wiring using two single core multistranded PVC insulated copper conductor FRLS Cable of size 4 sqmm 1100 volt grade drawn into PVC Cassing capping of suitable size including 4.0 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including chislling/cutting of wall, floor, making hole through wall & making good disturbed surfaces of wall/floor/ceiling to match with existing surface including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge.. Note: Two single core cable, earth wire and PVC conduit shall be measured as one length.
Supply and fix in industrial wall mounted plug socket suitable for IP 44 degree of protection with MCB SP 20Amps 'C' series, 10 KA, 2P+E complete all as specified and directed. Make: Indoasian/L&T/C&S.
Supply and fix Hot water pillar taps 15 mm bore cast copper alloy with capstan heads, chromium plated, screwed down high pressure with lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and directed by Engr-in-Charge.
Supply and fix Stop Valves , cast copper alloy, screwed down , high pressure with crutch or butter fly handle , screwed both ends for iron pipe or for unions and fixed of size 15/20 mm complete all as specified and directed by Engr-in-Charge.
M & L for Cutting existing GI pipe of any size, and Material and labour for CPVC 20 mm dia pipes with all fittings (Tees, bends, elbow, reducers etc) and fixed complete to wall and ceilings or laid in floors connecting hot water pipe from geyser complete all as specified and directed by Engr-in-charge.
Supplying, laying, jointing, commissioning and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade confirming to IS-7098 (Part-I-1988) laid in trenches/ducts/wall / floor / pipes/ poles including cable glands and aluminium lugs of appropriate size, PVC sleeve etc complete all as directed by Engr in -Charge for following sizes. Make :- Havells / Gloster / Finolex / Polycab Note : Earth work , bricks , riddled earth , GI pipe for protection of cable will be measured & paid under under relevant items of schdule.
50 sq mm 3.5 core
35 sq mm 3.5 core
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation of poles stays laying of electric cables, pipes etc and getting out in soft/loose soil complete all as specified and directed.
All as per item No 39 here-in above but in hard/dense soil.
Removing excavated material soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed
M & L for riddled earth for cushioning to under ground electric cable including spreading , levelling and hand punning complete all as directed. Note - Punned thickness shall only be measured & paid.
M & L for road cutting / foot path and making good with PCC 1:3:6 TYPE C-2 ( using 40 mm graded stone aggregate ) of 150 mm
M & L for Brick "class B" protection for under ground cable complete all as specified & directed .
Supply and laying GI tubes light grade, galvanized, 40 mm bore in repair ,laid in trenches or under floor or fixed with poles/walls for protection of electric cable all as directed
AJINKYA VIKRAM GAIKWAD (BID ID -3114076)
M/S JAYCONSTRUCTION CO (BID ID -3103171)
Aishwarya Constructions (BID ID -3103976)
Priyanka Power line (BID ID -3118933)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .