SE ONM SINGRAULI
O/O SE ONM SINGRAULI
Erection/Testing - Commissioning of new 33KV/11KV/LT Lines/distribution substations etc,on turnkey basis in rural/urban areas of Singrauli District under ONM Circle, Singrauli.
2023_PKVVC_276417_1
NO.Sec/DPC/SE/ONM/110 Singrauli, Dt. 15/05/2023
Open Tender
Electrical Works
Item Wise
365 days
UNDER SINGRAULI DISTT.
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,900
Yes
₹2 L
Yes
6 Jul 2023
17 May 2023
31 May 2023
17 May 2023
30 May 2023
17 May 2023
1 KM OF 33 KV LINE ON 280 KG, 9 MTR LONG PCC POLES WITH MAXIMUM SPAN OF 70 METER USING AAAC RACCOON CONDUCTOR FOR RURAL AREA without CUT POINT
1 KM OF 33 KV LINE ON 13 Mtr H-BEAM WITH MAXIMUM SPAN OF 70 METER USING AAAC DOG CONDUCTOR FOR RURAL AREA
1 KM OF 33 KV LINE ON 13 Mtr H-BEAM WITH MAXIMUM SPAN OF 40 METER USING AAAC DOG CONDUCTOR FOR URBAN AREA
33 KV LINE ON H-BEAMS 13 MTR. LONG SUPPORTS USING AAAC DOG CONDUCTOR DOUBLE CIRCUIT SINGLE STRINGING (DCSS) MAXIMUM SPAN 40 M FOR URBAN AREA
1 KM OF 33 KV LINE ON H-BEAMS 13 MTR. LONG WITH MAXIMUM SPAN OF 40 METERS USING AAAC DOG CONDUCTOR- DOUBLE CIRCUIT DOUBLE STRINGING (DCDS) FOR URBAN AREA
AUGMENTATION OF 1 KM OF 33 KV LINE WITH AAAC DOG CONDUCTOR AND MID SPAN 280 KG. 9.1 M PCC POLE
AUGMENTATION OF 1 KM OF 33 KV LINE WITH AAAC DOG CONDUCTOR AND MID SPAN 13 M H-BEAM
1 SPAN OF 70 MTR 33 KV LINE ON 13 M H-BEAMS FOR ROAD CROSSING (OVERHEAD) WITH AAAC DOG EXCLUDING NATIONAL HIGHWAY (NH) OR STATE HIGHWAY (SH)
33 KV SINGLE POLE CUT POINT IN 13 M H BEAM FOR STRAIGHT LINE & ANGLE UPTO 45º FOR URBAN AREA
SCHEDULE FOR 33 KV SINGLE POLE CUT POINT IN 280 KG. LONG PCC POLE FOR STRAIGHT LINE & ANGLE UPTO 45º FOR URBAN AREA
HEIGHT RAISING/MID SPAN POLE/ REPLACEMENT OF DETERIORATED/ DAMAGED POLES IN 33 KV LINES- 280 KG 9.1 MTR. LONG PCC POLE
HEIGHT RAISING/MID SPAN POLE/ REPLACEMENT OF DETERIORATED/ DAMAGED POLES IN 33 KV LINES- H-BEAM 13 MTR. LONG
33 KV D.P.STRUCTURE ON 280 KG.,9.1 MTRS.LONG PCC POLES
33 KV D.P.STRUCTURE ON H-BEAMS 13MTR. LONG FOR DOUBLE CIRCUIT SINGLE STRINGING
33 KV D.P.STRUCTURE ON H-BEAMS 13MTR. LONG FOR DOUBLE STRINGING DOUBLE CIRCUIT
33 KV T.P.STRUCTURE ON 280 KG.,9.1 MTRS.LONG PCC POLES
33 KV T.P.STRUCTURE ON H-BEAMS 13MTR. LONG FOR DOUBLE CIRCUIT DOUBLE STRINGING(DCDS) & DOUBLE CIRCUIT SINGLE STRINGING(DCSS)
33 KV FOUR POLE STRUCTURE ON 280 KG.,9.1 MTRS.LONG PCC POLES
33 KV FOUR POLE STRUCTURE ON H-BEAMS 13MTR. LONG
33 KV LINE FOR UNDER GROUND RAILWAY CROSSING BY ONE+ONE CABLE 3X300 SQ.MM. SPAN 90 M
33 KV LINE FOR UNDER GROUND NATIONAL HIGHWAY BY ONE+ONE CABLE 3X300 SQ.MM. SPAN 90 M
11 KV LINE ON 11 M H-Beam Using AAAC Raccoon Conductor Max Span 50 Mtrs IN RURAL AREA
11 KV LINE ON 140 KG, 8 M PCC Pole Using AAAC Raccoon Conductor Max Span 70 Mtrs IN RURAL AREA
1 KM OF 11 KV LINE ON 11 m H-Beam Using AAAC Rabbit Conductor maximum Span 70 Mtrs IN RURAL AREA
1 KM OF 11 KV LINE ON 8 Mtr PCC Pole Using AAAC Rabbit Conductor maximum Span 70 Mtrs IN RURAL AREA
1 KM OF 11 KV LINE ON H-BEAM WITH MAXIMUM SPAN OF 30 METER USING COVERED CONDUCTOR 70 SQ.MM. XLPE FOR URBAN AREA
11 KV Line on 11 Mtr. Long H-Beam with 35 sq.mm. AB Cable maximum span 30 Mtrs.
11 KV Line on 13 Mtr. Long H-Beam with 70 sq.mm. AB Cable maximum span 30 Mtrs.
11 KV Line on 13 Mtr. H-Beam with 3x95 sq.mm. AB Cable maximum span 30 Mtrs.
11 KV Line on 13 Mtr. H-Beam with 3x185 sq.mm. AB Cable (One + One) maximum span 30 Mtrs.
11 KV Single Pole Cut Point in 13 M H-Beam for Straight Line & angle upto 45º for Urban Area
Schedule for 11 KV Single Pole Cut Point in 8 M PCC pole for Straight Line & angle upto 45º for Urban Area
Schedule for 11 KV Single Pole Cut Point in 11 M H-Beam for Straight Line & angle upto 45º for Urban Area
11 KV Line Crossing Ag & Non Ag with Raccon conductor WITH 11 MTR. H-BEAM
11 KV Line Crossing Ag & Non Ag with Cover conductor WITH 11 MTR. H-BEAM
11 KV D.P.structures on 140 Kg.,8.0 M PCC poles for straight line
11 KV D.P.structures on 200 Kg.,9.0 M PCC poles for straight line
11 KV D.P.Structure on H-Beams 11 M (Single Circuit)
11 KV D.P.Structure on H-Beams 13 M (Single Circuit)
11 KV D.P.Structure on H-Beams 13 M for DCDS
11 KV T.P.structures on 140 Kg.,8.0 M PCC poles
11 KV T.P.structures on 200 Kg.,9.0 M PCC poles
11 KV T.P.Structure on H-Beams 11 M
11 KV T.P.Structure on H-Beams 13 M
11 KV FOUR POLE Structure on H-Beams 11 M
11 KV FOUR POLE STRUCTURE ON 200 kg 9.1 mtr long PCC POLE
11 KV FOUR POLE STRUCTURE ON H-Beam 13 mtr long FOR (DCDS)
MID SPAN POLE/ REPLACEMENT OF DETORIATED/ DAMAGED POLES IN 11 KV LINES PCC Pole 8 M
MID SPAN POLE/ REPLACEMENT OF DETORIATED/ DAMAGED/11 KV HEIGHT RAISING POLES IN 11 KV LINES H-BEAM 11Mtr
Augmentaion of existing 11 KV line to AAAC Rabbit with 8 Mtr PCC for mid span
Augmentaion of existing 11 KV line to AAAC Raccoon with 8 Mtr PCC for Mid Span pole
Augmentaion of existing 11 KV line to AAAC Raccoon with 11 Mtr H-Beam for Mid Span pole
Augmentaion of existing 11 KV line to ACSR Dog with 13 Mtr H-Beam for Mid Span pole
11 kV Line under ground Railway crossing with Cable one+ one (3x300 sq.mm.)
11 KV LINE FOR UNDER GROUND ROAD CROSSING (National Highway/State Highway) BY ONE+ONE CABLE (Span 100 mtr)
Road Crossing for 11KV (Overhead) excluding National Highway (NH) OR State Highway (SH) 13 M H Beam
(i) One KM. L.T. LINES 3 PHASE 5 WIRE ON RSJ 9.3 M USING [ 3 X 35 + 1 X 16 + 1 X 35 sq.mm. (insulated nuetral massenger)] AERIAL BUNCHED XLPE CABLE IN URBAN AREA
(ii) 3 X 50 + 1 X 16 + 1 X 35 sq.mm. insulated nuetral massenger (Span of 50 Mtr)
(iii) 3X95 + 1X16 + 1X50 Sq mm. (insulated nuetral massenger)(Span of 40 Mtr)
(iv) 3X150 + 1X35 + 1X95 Sq mm. (insulated nuetral massenger)(Span of 35 Mtr) with RSJ & H-Beam
(v) 3 X 25 + 1 X 16 + 1 X 35 sq.mm. (insulated nuetral massenger)
(vi) 3 X 50 + 1 X 16 + 1 X 35 sq.mm.(insulated nuetral massenger)
(vii)3 X35+1x16+1x35 Sq.mm. XLPE WITH MAXIMUM SPAN OF 50 METERS
(viii) 3 X 50+1x16+1x35 Sq.mm. XLPE WITH MAXIMUM SPAN OF 50 METERS WITH 200 KG PCC
One Km. CONVERSION OF L.T. LINES 3 PHASE 5 WIRE (BARE CONDUCTOR TO CABLE) USING 3 X 50 + 1 X 16 + 1 X 35 sq.mm.(insulated nuetral massenger) AERIAL BUNCHED XLPE CABLE WITH MID SPAN PCC POLE
One Km. CONVERSION OF L.T. LINES 3 PHASE 5 WIRE (BARE CONDUCTOR TO CABLE) USING 3 X 50 + 1 X 16 + 1 X 35 sq.mm.(insulated nuetral massenger) AERIAL BUNCHED XLPE CABLE WITH MID SPAN RSJ POLE
One Km. CONVERSION OF L.T. LINES 3 PHASE 5 WIRE (BARE CONDUCTOR TO CABLE) USING 3 X 95 + 1 X 16 + 1 X 50 sq.mm.(insulated nuetral massenger) AERIAL BUNCHED XLPE CABLE WITH MID SPAN RSJ POLE
One Km. CONVERSION OF L.T. LINES 3 PHASE 5 WIRE (BARE CONDUCTOR TO CABLE) USING 3 X 150 + 1 X 35 + 1 X95 sq.mm.(insulated nuetral massenger) AERIAL BUNCHED XLPE CABLE WITH MID SPAN RSJ & H-BEAM POLE
One Km. CONVERSION OF L.T. LINES TO DOUBLE CIRCUIT LT LINE (BARE CONDUCTOR TO CABLE) USING 3 X 95 + 1 X 16 + 1 X 50 sq.mm.(insulated nuetral massenger) AERIAL BUNCHED XLPE CABLE WITH MID SPAN H-BEAM POLE
AUGMENTATION OF L.T. CABLE (OF ANY SIZE) TO 3 X 50 + 1 X 16 + 1 X 35 SQ.MM AERIAL BUNCHED XLPE CABLE WITH MID SPAN PCC POLE
AUGMENTATION OF L.T. CABLE (OF ANY SIZE) TO 3 X 50 + 1 X 16 + 1 X 35 SQ.MM AERIAL BUNCHED XLPE CABLE WITH MID SPAN RSJ POLE
AUGMENTATION OF L.T. CABLE OF ANY SIZE) TO 3 X 95 + 1 X 16 + 1 X 50 SQ.MM AERIAL BUNCHED XLPE CABLE WITH MID SPAN RSJ POLE
AUGMENTATION OF L.T. CABLE (OF ANY SIZE) TO 3 X 150+ 1 X 35 + 1 X 95 SQ.MM AERIAL BUNCHED XLPE CABLE WITH MID SPAN RSJ & H-BEAM POLE
AUGMENTATION OF L.T. CABLE OF ANY SIZE) TO DOUBLE CIRCUIT USING 3 X 95 + 1 X 16 + 1 X 50 SQ.MM AERIAL BUNCHED XLPE CABLE WITH MID SPAN H-BEAM POLE
Service Line PVC Insulated 2 Core 6 Sq.mm Armoured Aluminium Conductor 1100 Volts for Smart Metering
Service Line PVC Insulated 4 Core 6 Sq.mm Armoured Aluminium Conductor 1100 Volts for Smart Metering
Service Line PVC Insulated 4 Core 10 Sq.mm Armoured Aluminium Conductor 1100 Volts for Smart Metering
Service Line PVC Insulated 4 Core 16 Sq.mm Armoured Aluminium Conductor 1100 Volts for Smart Metering
Service Line PVC Insulated 3.5 Core 35 Sq.mm Armoured Aluminium Conductor 1100 Volts for Smart Metering
25 KVA on 140 Kg., 8.0 Mtrs.long PCC poles
63 KVA on 140 Kg., 8.0 Mtrs.long PCC poles
100 KVA on 140 Kg., 8.0 Mtrs.long PCC poles
63 KVA on 11.0 Mtrs.long H-Beam
100 KVA on 11.0 Mtrs.long H-Beam
200 KVA on 11.0 Mtrs.long H-Beam
315 KVA on 11.0 Mtrs.long H-Beam
SHIFTING OF 11/0.4 KV, 25KVA SUB-STATION (ON 140 kg. 8 mtr. PCC POLE )
SHIFTING OF 11/0.4 KV, 63KVA SUB-STATION (ON 140 kg. 8 mtr. PCC POLE )
SHIFTING OF 11/0.4 KV, 100KVA SUB-STATION (ON 140 kg. 8 mtr. PCC POLE )
SHIFTING OF 11/0.4 KV, 100KVA SUB-STATION (ON 11 mtr. H-Beam )
Shifting of 11/0.4 KV, 200KVA OUT DOOR SUB-STATION (ON H-Beam )
Augmentation of 11/0.4 KV Dist. Transformer (Assuming 25 years of life and 10 years in service)
25 to 63 KVA
63 to 100 KVA
100 to 200 KVA
200 to 315 KVA
25 to 63 KVA (Old)
NITESH KUMAR CHATURVEDI
ANURAG TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .