Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.7 LAccepted-AOC AT BENUPUR PO CHASAPADA P S BALIKUDA DIST JAGATSINGHPUR | NAYAGARH | ODISHA | 752024 | L1 | Accepted-AOC OK | |
| 2 | OK₹15.7 LRejected-Finance AT PO PUNANGA PO MAHIPUR DIST JAGATSINGHPUR | OK | Rejected-Finance OK | |
| 3 | OK₹15.7 LRejected-Finance AT GOPALPUR PO GUMUDA DIST RAYAGADA | RAYAGADA | ODISHA | OK | Rejected-Finance OK |
Tender Value
₹18.4 L
EMD Value
₹18,430
Closing Date
3 Sept 2020, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE LI DIVISION, CUTTACK
OFFICE OF THE EXECUTIVE ENGINEER LI DIVISION, CUTTACK
INSTALATION AND ENERGISATION OF DIGHOR LI PROJECT
2020_OLIC_62142_25
08 / 2020-21, OLIC (CTC) / Dt. 27/07/2020
Open Tender
Civil Works - Lift Irrigation Schemes
Item Rate
365 days
BALIKUDA BLOCK
Please refer Tender documents.
2 documents required · 2 mandatory
₹6,000
Yes
₹18,430
Yes
21 May 2021
14 Aug 2020
4 Sept 2020
14 Aug 2020
3 Sept 2020
14 Aug 2020
14 Aug 2020 - 2 Sept 2020
90 days
Amount
CIVIL AND MATERIALS ITEMS
Earth work in hard soil for excavation of foundation including dressing and levlling the bed and depositing the soil within 50 mtr. initial lead and 1.5 mtr. initial lift as per direction of Engineer-in-charge.
Filling in foundation and plinth with sand watered and rammed including cost of sand as per direction of Engineer-in-charge.
Cement concrete (1:4:8) with 4 cm size h.g. metal as per direction of Engineer-in-charge.
Ist Class K.B.Brick (25cm x 12 cm x 8 cm ) having crushing strength not less than 75kg./cm2 with dimensional tolerance + 8% in cement mortar (1:6) in foundation and plinth.
CC(1:2:4) in foundation and plinth
Cement concrete (1:2:4) with 12mm size h.g chips for R.C.C. works including hoisting and laying.
Rigid smooth centering and shuttering for R.C.C. works including false work and dismentling them after casting including cost of materials complete in roof slab & Chajja. .
Labour cost for cutting, bending and binding of M. S. rod placing in position including cost of M. S. rod.Qty. @ 0.9% of R. C. C. work or 1.40qtl @ 78 qtl / cum
12mm thick cement plaster (1:6) for brick masonary
Cement Punning
Labour charges for lettering the display board in black colour , yellow back ground painting including the cost of materials.
Filling F & P with excavated materials including watering and ramming as directed by the Engineer-in-charge.
Labour charges for laying and jointing of 200mm dia PVC Pipe including carriage from stacking yard to site.
Labour charges for laying and jointing of 160mm dia PVC Pipe including carriage from stacking yard to site.
Provision for M. S. bolt for foundation 4 nos and MS hook for handling of FF
Dismantling of Lime Concrete, cement concrete grade M-10 and below including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres Unit = cum
Cost of laying and fitting of MS Tee and other PVC fitthing along the pipe line.
Extra labour and materials required for fitting and fixing of 25mm dia GI pipe for 50mm dia CI Air release valve at the sutable location of PVC pipe inside the air realease chamber including cost of petty materials.
Labour charges for lowering of S/S pump , fitting of delivery pipes , sluice valve, NR valve, Air Valve and riser Tee etc. including hire charges of T & P materials as required.
2.5 cm AS stone flooring with CC ( 1:2:4)
Wall painting two coats with cement paint of approved shade on new work
Provision of iron door and iron window each 1 no
Painting 3 coats over iron work
Cost of ventilator and sky light including fitting
Laying and fitting of 100mm dia GI pipe
Ist Class K.B.Brick (25cm x 12 cm x 8 cm ) having crushing strength not less than 75kg./cm2 with dimensional tolerance + 8% in cement mortar (1:6) in superstructure.
Electrical earthing with the help of 1½" GI pipe 2 Nos including all labour and materials required such as GI wire , GI socket , Charcoal, Salt, small size nut and bolts and all other materials required including excavation of earth pit and fitting thereoff complete.
10 H.P.Submersible Pump set ( BEE STAR Lebeled Energy efficient ) coupled with totally enclosed squirrel cage induction motor with delivery discharge 900 LPM at 25 mtrs. Head with cable, cable clip, support clamp etc. suitable for operation at 415+6% ,-15% volt,3 phase ,50 Hz, AC power supply with ISI mark and guarantee . The materials of construction as given below. (a) Motor casing.. stainless steel AISI 304 (b) Impeller ... bronze (c) Pump shaft... stainless steel (d) Sand guard...... bronze. (e) Non-return valve... CIFG 200.
Automatic Control Pannel wth sheet steel enclosure suitable for operation of squirrel cage induction motor for 10HP having full load current of 16 Amp at 415V +6%- 15%, 3phase,50Hz, AC supply with over load relay range 7 to 10 Amp and No volt coil suitab
Main Switch 63 Amp including fitting and fixing as per IS No.-4064(Part-I & II) with utilisation capacity category AC-22.
3 ph. 4 wire 20 - 100 Amp. 3 x 230 Volt (P-N) current meter with ISI mark as approved by DISTCO,CESU with matching fibre glass with T.P Box(M.S)
4 KVAR Capacitor
3 x 10 sqmm Trapoder cable XLPE (Cross link polyethylin ) including laying below the ground and filling the excavated materials including watering and ramming with ISI mark and guarantee.
100 mm dia GI socket
100mm dia nominal bore G.I.Pipe having wall thickness 4.5mm electrical resistance welded of medium class conforming to IS - 1239 (part-I/2004) with latest Amendments,screwed at both ends as per IS -554 socketed at one end and the other end protected with plastic threaded protector. The socket conforming to IS:1239 (Part-II/1992) with latest Amendments in random length of 4 to 7 mtrs. Each pipe should bear ISI Certification and manufacturers name/trademark , for fitting in Suction & Delivery Pipes.
100 mm dia C.I.Reflux valve(N.R)
100 mm dia C.I.Sluice valve
100 mm dia GI Bend
100 mm dia GI Flange
100 mm dia MS clamp
200mm dia PVC end cap
Cost of 2.5mm Sqx3 core submersible flat cable of IXI mark suitable for 10 HP pumpset
160mm dia PVC pipe
Unplasticised rigid UPVC pipe ivory gray in colour having specific gravity of 1.40 to 1.46 gms/cc of straight length of 6(six) meter for portable water supplies conforming to IS - 4985 / 2000 of BIS - Amendment - 2 read with Table-1 of IS - specification bearing ISI marks for working pressure Cl-II UPVC pipe to withstand pressure of 2.5 kgf/sqcm & the specification and manufacturer name should be prominently marked on body of each pipe as per the latest Amendment of IS-4985. It includes the cost of sockets in case of plain ended pipe. PDI test are to be conducted and should be marked on body of each pipe and report is to be obtained from CIPET, Bhubaneswar / EPM., Orissa, Bhubaneswar for necessary approval of authority including transportation and laying at site all complete. (i) 200 mm dia P.V.C. Pipe.
160mm equal Tee
200 mm dia PVC Equal Tee
160 mm dia PVC End cap
Solvent Cement
Cost of 50 mm Ø Air release valve with acessories
160x160x100 mm dia MS Tee with closing arrangement
160mm dia PVC coupler
200mm dia PVC coupler
200mm dia butterfly valve
200x100 mm T/W cap
12mm dia PVC insulated wire rope
200x160 PVC reducer
200x200x100mm PVC Tee with accessories
ELECTRICAL ITEM
Construction of 3 phase 11 KV line as per REC standard confirming to IE Rules 1956 with 300 kg 9 M long PSC Pole with 55 Sqmm AAAC , 11 KV "V" Cross arm, with required No.of 11 KV T & C Disc. Insulators in tension point & 11 KV Pin insulators, Couping & Padding of Poles. Danger Board at each Pole, Anti Climbing Devices, Stay Set at Bending point & double stay at end point with 18 mm G.I.H.T.Stay, concreting of Stay with Anchor plate, guarding at Road crossings etc. including cost of all materials, labour transportation,inspection & commissioning etc. complete.
Construction and erection of 11 /0.4 KV , 25 KVA Double Pole mounted Substation Star rated confirming to RE Rules 1956, mounted on 2.44 Mtr. Long structure, supported in 300 kg 9 mtr long PSC pole,transformer hard channel & top channel made of 2.8 M long 100 X 50 X 6 mm M.S.Channel, Transformer belting on 2.80 M long 50 X 50 X 5 mm M.S.Angle, (all REC SPN Std.F-3) with all accessories like 3 pole 11 KV HG Fuse(F-5)& A.B.Switches(F-9) both mounted on 2.8 M long 75 X 40 X 6 mm M.S.Channel and supported by 1.0 M long 50 X 50 X 5 mm M.S.Angle, with 3 No. 11 KV Lightening Arrestors & Distribution box for 25 KVA S/S, G.I.pipe earthing with 25X5mm G.I.Flats including cost of 25 KVA 11/0.4 K.V.Transformer , 35 Sqmm 3 1/2 Core PVC Cable - 40 mtr couping & padding of Poles, Danger board at each Pole, Anti climbing Devices & all other necessary fittings i.e required size Nuts & Bolts, Brackets, Cable, Cable Sockets, barbed fencing ( size (15'x10') with constn. of retaining wall, erection of RCC fencing post , sand filling and metal spreading ,fixing of iron grill gate etc as per cesu specification etc. including cost of all materials, labour , transportation complete with liasioning for testing inspection & commissioning.
11 KV line DP
HUIKA MANMATHA
TRILOCHAN NAYAK
stage.html
html • 0.05 MB
techsummary_326901.pdf
PDF • 0.28 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_326901.pdf
PDF • 0.02 MB
DIGHOR1.pdf
PDF • 0.40 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .