| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹78.5 LAccepted-AOC ASADUNA TODRAN TEHSIL BAHADURGARH DISTRICT JHAJJAR 124505 HARYANA | BAHADURGARH | JHAJJAR | HARYANA | 124505 | L1 | Accepted-AOC ok | |
| 2 | L2₹79.8 L+₹1.3 L (1.71%)Rejected-AOC NEAR GOVT MIDDLE SCHOOL VILLAGE KHERI SANWAL TEHSIL AND DISTRICT CHARKHI DADRI | CHARKHI DADRI | CHARKHI DADRI | HARYANA | L2 | Rejected-AOC ok | |
| 3 | Not Admitted-Fee/PreQual/Technical 171 B 4 MADHUR VIHAR DELHI | EAST DELHI | DELHI | 110092 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 4 | Not Admitted-Fee/PreQual/Technical CHARKHI DADRI | CHARKI DADRI | HARYANA | 127022 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹67.6 L
EMD Value
₹1.4 L
Closing Date
10 Mar 2021, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
W/S Feeder Division, Rohtak
Construction of 4th class quarter (P.H. JF-II at RD 343100 of JLN Feeder) Salhawas, Distt. Jhajjar.
2021_HRY_161628_2
No. 1210-30/2-A
Open Tender
Civil Works - Buildings
Item-rate/Agreement basic
180 days
Rohtak
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
₹1.4 L
Yes
15 Apr 2021
3 Mar 2021
12 Mar 2021
3 Mar 2021
10 Mar 2021
3 Mar 2021
90 days
Amount
Earth work in excavation in foundations, trenches, etc. in all kinds of soils, not exceeding 2 meters depth including dressing of bottom and sides of trenches stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry, in 15 cm layers with compaction, including disposal of all surplus soil, as directed with in a lead of 30 meters. (HSR. 6.6)
Earth work in filling under floor with lead up to 60 mtr. As per HSR item No-6.2 ( b ) (i) & 6.3 (i)
Cement concrete 1:8:16 with stone aggregate 40 mm nominal size in foundation and plinth (HSR 10.28)
Cement concrete 1:4:8 with stone aggregate 20 mm nominal size in foundation and plinth (HSR 10.38)
Cement concrete 1:11/2:3 with stone aggregate 20 mm nominal size for reinforced concrete work in footings, strips, foundations, beams, rafts, pedestals and approach slabs of bridges etc. excluding steel reinforcement and including centering and shuttering, laid in position, complete in all respects. (For works upto 1.5 meters below ground level (HSR 10.90 + 10.95 a)
First class brick work laid in cement sand mortar 1:6 in foundation and plinth (HSR 11.2)
Damp proof course 40 mm thick of cement concrete 1:2:4 using stone aggregate 20 mm nominal size with 2 coats of bitumen 20/30 preparation at 1.65 kg per sqm laid hot and sanded (HSR 10.114)
Base course of floors consisting of 100 mm thick cement concrete 1:8:16 and 100 mm sand or stone filling (HSR 14.1)
Conglomerate floor 50 mm thick cement concrete topping 1:2:4 (HSR 14.10)
Steel reinforcement TMT bars FE-500 EQR/FE-500 D grade or more for RCC work, where no included in the complete rate of RCC including straightening, bending, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. and placing in position complete in all respects for all heights /depths/storeys/basements etc. NOTE:- Reinforcement shall be measured in length including hocks, if any, separately for different diameters as actually used in work, excluding overlaps, Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. (HSR 18.22)
First class brick work laid in cement sand mortar 1:6 in first storey upto 4 meters above plinth level (HSR 11.7)
First storey
Third storey/mumty
11.43 cm thick brick wall laid in cement sand mortar 1:4 in superstructure (HSR 11.48) (a)
First storey
Second storey
Cement concrete 1 :11/2 :3 with stone aggregate 20 mm nominal size for reinforced concrete work in shelves excluding steel reinforcement, but including centering and shuttering, laid in position, complete in all respects. (HSR 10.81+ 10.95 (a)
First Storey
Second storey
Cement concrete 1:11/2:3 with stone aggregate 20 mm nominal size for reinforced concrete work for walls exceeding 20 cm thickness (straight and curved) beams, girders, stairs, columns, (square or rectangular) battens and lintels etc. excluding steel reinforcement but including centering and shuttering, laid in position complete in all respects. (HSR 10.86 + 10.95 (a))
First storey
Third storey/mumty
Cement concrete 1:11/2:3 with stone aggregate 20 mm nominal size for reinforced concrete work in slabs with inclination not exceeding 25 degree with horizontal, excluding steel reinforcement, but including centring and shuttering, laid in position, complete in all respects. (HSR 10.82 + 10.95 (a)
First storey
Third storey/mumty
Terracing consisting of tiles 22.86 cm x 11.43 cm x 3.81 cm laid over 87.50 mm mud filling on a layer of 25 mm mud plaster and another layer of mud mortar for laying the tiles, including two coats of bitumen laid hot at 1.65 kg per sqm on top of RCC slab including grouting with cement sand mortar 1:3 and top surface to be left clean etc. (HSR 13.13)
Second Storey/mumty
Top khurra 0.6 m x 0.6 m for rain water pipe in 25 mm thick cement concrete 1:2:4 ovr 50 mm thick cement concrete 1:8:16 (HSR 13.50)
Supplying & fixing in position G.I pipe class 'B' spouts in chajjas and cantilevers. (HSR 13.55 (e) 50mm i/d G.I. pipe
Bottom khurra on ground 1.2 m x 0.6 m consisting on brick-on-edge laid in cement mortar 1:3 over 75 mm cement concrete 1:8:16 including 12 mm thick cement plaster 1:3 (HSR 13.57)
First storey
Cement concrete 1:2:4 gola 10 cm x 10 cm quadrant along junction of roof with parapet wall finished smooth, where specially specified (HSR 13.64)
Second Storey
Providing & fixing PVC rainwater pipe 6 kg. pressure of ISI mark in cement mortar during masonary work (b) 150 mm dia PVC pipe 6 kg pressure (Note:- Reputed make PVC pipe such as Supreme, Finolex, Prince will be used as approved by Engineer-in-charge (HSR. 13.89) (b).
First storey
Providing and fixing PVC bend ISI mark (b) 150 mm dia PVC bend (Note:- Reputed make PVC bend such as Supreme, Finolex, prince will be used as approved by Engineer-in-charge. (HSR 13.90)(b) Note The Agency to whom the work ia alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material.
First storey
Screed of 50 mm thick cement concrete 1:8:16 to be laid below the topping (HSR 14.4)
First floor
Second floor/mumty
Marble stone flooring 20 mm to 25 mm thick slab including matching grains of marble laid in any pattern as specified over base of 12 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of marble including rubbing and polishing (using marble stone slab of size more than 0.38 sqm each) (HSR no. 14.49) (a) (i) white marble
Ground floor
First floor
Marble stone 20 mm to 25 mm thick in risers of step, skirting, dado, pillars and wall lining including matching the grains of marble slab in any pattern as specified laid on 12 mm thick cement coarsed sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of marble including rubbing and polishing, including labour for fixing cramps, pins and dowels etc. HSR-14.52 (a) (i) White marble
Ground floor
First floor
Kotah stone flooring minimum 34 mm to 40 mm thick in any pattern as specified over 12 mm thick base of cement coarse sand mortar 1:3 ladi and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishing (HSR 14.62)
Ground floor
First floor
Second floor/Mumty
Extra for noising in treads of steps of kotah stone slab (HSR 14.65)
Ground floor
First floor
Kotah stone 20 mm thick in skirting risers of steps, dados and wall facing (lining ) and pillars laid on 12 mm thick cement coarse sand plaster 1:3 ladi and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishing including labour for fixing cramps, dowels and pin etc. (HSR 14.66)
Ground floor
First floor
Second floor/Mumty
Providing & Fixing Ist Quality ceramic glazed wall tiles conforming to IS. 15622 ( thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy bottle green, black of any size as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 coarse and jointed with grey cement slurry including ointing in white cement mixed with pigment of matching shades complete. (b) size of ceramic glazed tiles 300 x 450 mm of reputed manufacturer like:- RAK, N"ITCO, Kajaria, SIMPOLO & ORIENT BELL shall be used as approved by Engineer-in-charge (HSR 14.92) (b)
Ground floor
Providing and laying Baroda Green marble stone 17 mm & above thick in skirting/dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of marble including rubbing and polishing. (HSR 14.95)
Ground floor
First floor
Providing and laying Baroda Green marble stone 17 mm & above thick in flooring including matching the grains of marble slab laid in any pattern as specified over base of 12 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of marble including rubbing and polishing. (HSR 14.96)
Ground floor
First floor
Plastering on walls 12 mm thick cement plaster 1:4 (HSR 15.5)
External Plaster
First storey
Second storey
Third storey/mumty
Plastering on wall 12 mm thick cement plaster 1:6 (HSR 15.7)
First storey
Second storey
Third storey/mumty
Plastering on wall 15 mm thick cement plaster 1:6 on the rough side of single or half brick wall 1:6 (HSR 15.12)
Internal Plaster
First storey
Second storey
Third storey/mumty
10 mm thick cement plaster 1:4 under side of ceiling (HSR 15.52)
Ground floor
First floor
Second foor/mumty
Preparation of ply wood surface for painting including sand paparing the surface and applying filling with approved quality filler consisting of with lead, linseed oil, varnish and chalk miti including finishing the surface to required finish complete. Painting on wooden surfaces etc. (HSR 16.1) Through Rate
Applyng pink primer or aluminium priming coat on wood work including preparation of surface knotting and stopping etc. (Note:- First quality paint/primer of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, drum of paint shall be opened in presence of Engineer-in-charge) (HSR 16.2) Through Rate
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (Note:- First quality paint of reputed make firm such as goodlass- Neolac, Berger, Garware, Jenson, Nicholson, Asian & shalimar shall be used as approved by Engineer-in-charge in writing, drum of paint shall be opened in presence of Engineer-in-charge. (HSR 16.3) Through Rate
Applying priming coat with metal primer on new steel or iron work including preparation of surface, painting on mettalic surfaces etc. (Note:- First quality paint/primer of reputed make firm such as goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & shalimar shall be used as approved by Engineer-in-charge in writing, drum of paint shall be opened in presence of Engineer-in-charge) (HSR 16.9) Through Rate
Painting two coats excuding priming coat with ready mixed paint for metelic surfaces in all shades on new steel or iron work (Note:- First quality paint of reuted make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, drum of paint shall be opened in presence of Engineer-in-charge) (HSR 16.17) Through Rate
Distempering with washable oil bound distemper (of approved manufacture) two coats over one priming coat on new work. (Note:- First quality paint of reputed make firm such as goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar shall be used as approved by Engineer-in-charge in writing, drum of paint shall be opened in presence of Engineer-in-charge. (HSR 16.58) Through Rate
Providing two coats of exterior acrylic emulsion paint. (Note:- First quality paint of reputed make firm such as goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar shall be used as approved by Engineer-in-charge in writing, drum of paint shall be opened in oresence of Engineer-in-charge.) (HSR 16.79) (b) Through Rate
Providing and applying two coats white cement based putty over plastered surface and grindling the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material, labour charges, scaffolding, sundries etc. complete. (Note:- Reputed make putty such as JK/Birla shall be used as approved by Engineer-in-charge). (HSR 16.81) Through Rate
Providing and fixing commercial type block board, plain lining, butt jointed, including wooden plugs (teak) placed at 45 cm to 60 cm centers, complete with necessary nails (frame work shall be payable extra) (b) 19 mm thick (HSR 17.49 (b))
First storey
Second Storey
Supplying and fixing hydraulic door closer, ISI mark, with necessary screws, etc. complete (HSR 17.82) (C.) ISI designation no. III size of door 851 mm to 1000 mm)
Providing & fixing sliding bolt with nuts & screws, etc. complete (HSR 17.83) (b) (i) Aluminium size 300 mm x 16 mm
Providing & fixing 0.50 mm thick aluminium sheet including cost of necessary screws etc. complete (HSR 17.87)
Factory manufactured solid flush door shutters with block board core as per I.S no. 1659-1669 bonded with water proof type phenol formaldehyde synthetic resin, hot-pressed, conforming to I.S 2202 part-I anf II fixed in position, including iron hinges, screws, chocks/cleats, and stops etc. (Excluding the cost of any fittings, other than specified above, but including labour for fixing the same in position) -(Note) : - Commercial veneering with vertical grains or cross bands and face veneer on both sides commercial facing with laminatyed core and lipped edges. (Duro, green) 35 mm thick (HSR 17.93) (a) (iii))-Note I under 17.18.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS 733 and IS : 1285 fixed with rawl plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom, and sides with required neoprene felt etc. Aluminium sections shall be smooth, rust free straight mitred and jointed mechanically wherever required including cleat angle. Aluminium snap beading for glazing/paneling C.P brass/stainless steel screws, etc. complete. Shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of PVC/neoprene gasket required including aluminium fitting (HSR 17.96) + note (i) Add Rs. 15/- per kg. extra if powder coating of 50 micron is done instead of anodizing in above item no. 9 & 10.
Providing and fixing glazing in aluminium door, windows, ventilator shutter and partitions etc. with PVC/neoprene gasket etc. complete (cost of aluminium snap beading shall be paid in basic items) (HSR 17.98 (b) with float glass panes of 5.00 mm thickness
Wrought iron and mild steel (using angles, flats, square bars, tees and channels), ladders, grills gratting frames, window guards, iron doors openable or fixed staircase or parapet or any other type of railing, gates and tress guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position (HSR 18.12)
Pressed steel sheet frames (Chowkhats) consisting of 2 mm thick steel sheet of the specified section including ironlugs (hold fasts) iron hinges, conforming to PWD specifications, including bolts for fixing stops, locknotch, provision for receiving tower bolts and finished with one coat of ready mixed paint red lead non-setting primer of approved quality fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:3:6 for lugs complete. (a) Door and window frame of size 89 mm x 50 mm with 40 mm wide single rebate (Item no. 18.34)(a)
First storey
Door and window frame of size 127 mm x 50 mm with 40 mm wide double rebate (HSR 18.34) (c)
Dismentling Brick Work / Tile Lining in C.M as per HSR Item No. 8.5 (b)
Dismentling Reinforced cement concrete with cleaning & straightening & cutting of bassis required HSR Item No. 8.6 (e)
Removing Door with the dismanteling of walls as per HSR item no- 58 (b), 8.17 (a) (b) Remom Window 8.17 (b).
Dismentling of C.C Plain 1:2:4 as per HSR item no- 8.6 (d)
Cement Concrete (1:2:6) gola 10cm x 10cm junction of roof with parapet as per HSR item No- 13.64
Credit of Brick Bats
Credit of Steel
Excavation of trenches in streets, lanes or in open areas for storm sewer, sewers running by gravity and manholes to full depths as shown in drawings including shoring, timbering of poling boards, frame system type, dressing to correct sections and dimensions, according to templates and levels, dewatering, provision for diversion of traffic, cutting trees and bushes, etc. night signals profiles, pegs, sight rails, boning rods, crossing over trenches for access to the houses, watching fencing etc. fixing and maintenance of caution board refilling of trenches, watering of refill, in 15 cm layers ramming and restoration of unmetalled or unpaved surface to original condition and removal of surplus soil, from site of work, upto a lead of 1 Km in oridnary soil. (a) for depths excavation not exceeding 3 metres below ground level. [HSR 6.10 (a)].
Cement concrete 1:8:16 with stone aggregate 40mm nominal size in foundation and plinth. (HSR 10.28).
Cement Concrete 1:2:4 with stone aggregate 20 mm nominal size in foundation and plinth. (HSR 10.41).
Providing for laying, jointing, fixing and testing G.I. (Medium class "B" type of Tata & Jindal make) pipe lines and specials tees bends, sockets, elbows etc. inside building and testing etc. complete including cutting threading. Including cost of Special. G.I. specials shall be of Make:- UNIK, TATA, ZOLOTO. (NS)
(i) 15 mm internal diameter of pipeline
(ii) 20 mm internal diameter of pipeline
(iii) 25 mm internal diameter of pipeline
(v) 40 mm internal diameter of pipeline
Extra for fixing and jointing union couplings in G.I. and W.I. pipelines. [HSR 28.21].
(a) 15 mm internal diameter
(b) 20 mm internal diameter
(c) 25 mm internal diameter
(e) 40 mm internal diameter
Drilling and Tapping cast iron pipe lines of all diameters and screwing in ferrule and connections-Size of ferrule. [HSR 28.22].
40 mm internal diameter of pipeline.
Cutting holes upto 23 cm square through brick work in mud walls for pipes and making good including repointing replastering and finishing according to existing finish where required. [HSR 28.23].
(i) 11.43 cm thickness of walls
(ii) 22.86 cm thickness of walls
Fixing and jointing gun metal peet valves (heavy pattern) with hand wheels, on G.I. pipelines laid in the ground or inside building including cartage from divisional stores or nearest railway station to site of works. (HSR 28.29).
20 mm internal diameter
25 mm internal diameter
Constructing brick masonry inspection chamber sizes as given below upto 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 percent limer mortar 2:3 in foundation cement concrete 1:2:4 benching 12 mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2;4 slab 100 mm thick./C.C. topping 50 mm thick with 455 mm x 455 mm 610 mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint coplete as per standard design. [HSR 29.84].
(a) Size 450 mm x 450 mm
(b) Size 450 mm x 600 mm
(c) Size 600 mm x 900 mm
Constructing brick masonry road gully chamber as per standard drawings (as per sizes given below) including dressing of beds and sides of chamber to exact profiles, 15cm thick lime concrete 16:24:100 (as per specified in item no 10.6) in foundation, Ist class brick work laid in cement sand mortar, 1:5, 40mm thick cement concrete 1:2:4, topping inside the chamber with a floating coat of 1.5 mm thick neat cement laid in one operation to the topping the entire inner surface of the chamber rendered with neat cement not less than 12 mm in thickness of 1:2 cement sand plaster and finished with a floating coat of neat cement 1 mm thickleft absolutely smooth polished and correct to templates including labour for fixing the C.I. road gully grating and frame including painting with coal tar (as specified in item no. 29.48 complete and to the requirement of the Engineer-In-charge). (a) Single Road Gully Chamber (i) Size 610 mm x 457 mm x 800 mm. [HSR 29.87 (a) (i)].
CONSTRUCTION OF RECTANGULAR STANDARD BRICK MASONRY MANHOLE CHAMBERS to standard drawings on S.W pipe sewers or other circular pipe sewers upto the required depth in 1.5 CEMENT SAND MORTAR, lime concrete in bed and sides of pipe sewer and cement concrete 1:2:4 in benching, 12 mm thick water tight 1:2 cement sand plaster with a floating coat of neat cement and finished with 2 coats of sodium solicate on interior surface where required, reinforced cement concrete slab 180 mm thick fixing 560 mm internal diameter C.I. manhole cover and frame weight not less than 2.5 quintal painted with 3 coats of black bitumen paint, fixing galvanised malleable iron steps embedded in 1:2 cement sand mortar complete. The rate cover the cost of M.S steel for R.C.C slab Labour for fixing and carriage of C.I manhole frame and cover and malleable iron steps from the stores of the Engineer-in-charge of the works to the site of works. The rate also includes the cost of accurately planned and fitted centring, supports for all works as well as for all curves and special work, cleaning out their beds etc. Sodium silicate shall be supplied free of cost at the stores of Engineer- in-charge. [HSR 29.90 (ii)].
(ii) On 150 mm I/d Pipe sewer
(a) For 1.20 Mtrs. depth below ground level
Providing, lowering, laying, cutting (cut surface to be uniformity finished) jointing with rubber rings marked with IS:5382 and testing of SPIGOT AND SOCKETTED RCC NP2 MARKED WITH IS:458-1988 and specials into trenches for all depths including carriage, loading, unloading, stacking, handling, re-handling etc. complete in all respects to the satisfaction to the Engineer -in-charge. (c) 300 mm dia. (HSR 29.93).
Providing and fixing in position best indian make (as approved by the engineer-in-charge European type water closet suite, syphonic type consisting of- (i) VITREOUS CHINAWARE SYPHONIC SUITE WITH 15 LITRES CAPACITY MATCHING CHINAWARE CISTERN and all internal brass fittings COMPLETE WITH ‘P’ or ‘S’ TRAP with or without vent; (as approved by the Engineer-in-charge). (ii) One piece SEAT AND LID IN HOLLOW BLACK OR WHITE PLASTIC fitted with chromium plated hinges and rubber buffers, (to the approval of the Engineer-in-charge) COMPLETE in all respects INCLUDING CUTTING AND MAKING GOOD THE WALLS AND FLOORS. (b) Double trap syphonic (ii) Single Color. [HSR 30.5 (b) (ii)].
EXTRA OVER item nos. 30.1 to 30.4 and 30.6 FOR PROVIDING AND FIXING 15 LITRES CAPACITY C.I. LOW LEVEL VITREOUS CHINAWARE CISTERN complete with flush bend all other necessary Fittings instead of C.I high level cistern complete with fittings. (i) White. [HSR 30.12 (i)].
EXTRA OVER item nos. 30.3 to 30.6 FOR PROVIDING AND FIXING BEST INDIAN MAKE PLASTIC HYGENIC SEAT with lid complete instead of hollow Black or white plaster seat and lid.(i) White plastic seat (Solid). [HSR 30.13 (i)].
EXTRA FOR providing and fixing 32 MM dia G.I./C.P FLUSH PIPE complete with accessories instead of 32/MM dia galvanized telescopic flush pipe with clips (as required by the Engineer-in-charge). (i) 32 mm dia G.I. flush pipe. [HSR 30.15 (i)].
Providing & Fixing in position best indian make (ordinary) lavatory suites consisting of:- (v) Size 560 mm x 450 mm with one no. tap. [HSR 30.41(v)].
PROVIDING AND FIXING IN POSITION 32 MM DIA G.I. WASTE PIPE EMBEDDED IN WALL or lead waste pipe (weighing 3.47 kg. per metre and 2.8 mm thick) upto floor Level including cost of wipped solder joint etc., complete (as required by the Engineer-in-charge). [HSR 30.48].
Providing and fixing in position best quality Stainless Steel Sinks with Complete fittings as fully described in item No. 30.51. (a) 600 mm x 450 mm x 200 mm. [HSR 30.53 (a)].
Providing and fixing in position best Indian make towel rails fixed in with rawlslugs embedded in walls with C.P. Brass screws, complete in all respect including cutting and making goods the walls etc.: (a) 25 mm dia, C.P. Brass adjustable. (i) 750 mm long. [HSR 30.68 (a)]
Providing and fixing in position super quality 65 mm i/d opening C.P brass dome type hinged grating weighing about 750 gms fixed in cement mortar 1:2 complete in all respects (as required by the Engineer-in-charge). [HSR 30.74].
Providing and fixing in position 15mm i/d C.P. brass bib cocks of best quality (as required by the Engineer-in-charge). [HSR 30.75].
(a) Bib cock long body.
Providing & fixing in position C.P. brass stop cock (as approved by the engineer-in-charge). (a) 15 mm Stop cock. (ii) Concealed stop cock with flange. [HSR 30.76 (a) (ii)].
Providing and fixing in position best Indian make flexible tube connection. (b) C.P. Brass (iii) 15mm x 450 mm. [HSR 30.82 (b) (iii)].
Providing and fixing in position H.C.I. Soil waste vent or antisyphonage pipes to I.S.I. specifications of E.L.C. manufacture or of any other reputed firm including cutting and wastage etc. and cutting holes in walls, roofs or floor etc. and making good to its original condition but excluding cost of lead jointing. (HSR 30.84)
(a) 100 mm internal diameter.
Providing and fixing in position C.I. Gully trap cover weighing approximately 7.26 Kg. and frame for gully trap chamber clear opening size 300 mm x 300 mm and out side size 330 mm x 330 mm including painting the exposed surfaces with 3 coats of black bitumastic superior paint of approved manufacture etc. (HSR 30.85).
Providing and fixing in position M.S. or heavy flat iron clamps made out of M.S. flat not less than 5 mm of the approved design for fixing C.I. soil waste vent or anti pipes to walls complete in all respects. (a) for 100 mm interal diameter pipes. (HSR 30.88).
(a) for 100 mm interal diameter pipes.
Providing & Fixing H.C.I. floor traps I.S.I. marked of the self cleaning design with C.P. brass hinged grating with frame with or without vent arm and including cement concrete 1:2:4 under and around the floor trap where required upto floor level complete in all respects including cutting and making good the walls and floors, etc. minimum depth of water should be 50 mm with a minimum seal of 50 mm. (b) with 75 mm i/d outlet. [HSR 30.89 (b)].
Providing and fixing in position H.C.I. specials for soils, waste, vent or anti-syphonage pipes to I.S.I. marked including cutting and waste etc. cutting holes in walls roofs or floors etc., and making good to its original condition but excluding cost of lead jointing. (HSR 30.91).
(a) For 100 mm dia pipes
(2) Double Junction with door 100 mm x 100 mm x 100 mm x 100 mm
(4) Single Junction with door 100 mm x 100 mm x 100 mm x 100 mm
(16) Cowls
(22) Collars
Providing and fixing in position automatic brass ball valves in tanks. (b) With Plastic Ball (ii) 20 mm internal diameter. [HSR 30.110 (b) (ii)].
Providing & Fixing in position gully traps fixed in cement concrete 1:4:8 complete with H.C.I. grating 150 mm x 150 mm cast iron cover weighing approximately 7.26 Kg. and frame clear opening 300 mm x 300 mm and outside size 330 mm x 330 mm and chamber including cost of all brick work in cement mortar 1:5 cement concrete 1:2:4, in coping black bitumastic superior paint of approved manufacture on all C.I. work as per standard design, minimum depth of water should be 150 mm with a minimum seal 50 mm. (b) 100 internal diameter H.C.I. gull trap. [HSR 30.114 (b)].
Providing and Fixing HDPE WATER STORAGE TANKS of Sintex, Diplast, O.K. Supreme make with covers/lids marked with IS:12701 on roof top of buildings including cost of hoisting and placing in position, making connections with inlet and outlet pipes, providing overflow and scour provisions with suitable plug on scour pipe including cost of nipples, washers flages for connections in tanks complete in all respects to the satisfaction to the Engineer-in-Charge. [HSR 30.119].
700 Ltrs. Capacity Water Tank
M.S.Sheet .
Supply and erection of 3 mm thick mild steel sheet duly welded on existing M.S. angle iron frame for fixing the main switches etc. as required, duly painted with three coats of approved paint including one coat of red oxide.
(K) Distrubution board with plug and socket.
Supply and erection of sheet steel enclosure 2 pole / 3 pole with earth plug and socket suitable for incorporating single pole / triple pole MCB on wall / on existing pedestal complete with necessary connections etc.
S.P.N. enclosure for single pole MCB 20 amp.
Blanking sheet .
Supply and erection of blanking sheet in existing distribution board.
(L) Miniature Circuit Breaker and Isolator.
Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections.
SP MCB of 9 KA breaking capacity 6 amp. to 32 amp.
TP MCB of 9 KA breaking capacity 40 Amp.. to 63 Amp..
TPN MCB of 9 KA breaking capacity 40 amp. to 63 amp.
(M) Supply and erection of Fittings and Accessories.
Bell push with 4 metres 2-core , 0.50 sqmm (16 / 0.20 mm).PVC flexible wire.
Bakelite angle / straight button holder large size.
Bakelite sheet including fixing with brass screws and washers.
3 mm thick .
Ceiling rose flush / surface type .
Supply and erection of hexagonal M.S. box 1.60 mm thick having each side 8 cms , 7.5 cms deep top covered with M.S. lid by means of screws including 10 mm dia 30 cm long mild steel rod made into suitable suspension hook and erected in RCC slab for erection of fan , the bottom covered with 3 mm thick bakelite sheet with suitable holes , painting etc. complete with all labour and material required to complete the job. .
Pdg., one extra junction box with 0.55 metre long 20mm dia conduit pipe for the erection of fluorescent tube fitting complete with all required labour and material.
(P) Pipe Laying.
Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required.
Heavy guage welded conduit pipe 20 mm dia 1.60 mm thickness flushed.
Heavy guage welded conduit pipe 25 mm dia 1.60 mm thickness flushed.
Heavy guage welded conduit pipe 32 mm dia 1.60 mm thickness flushed.
(Q) Earthing
Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
Extra for charcoal or coke and salt for G.I. Plate or copper plate earth electrode.
Pdg. and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required .
Pdg. and fixing 25 mm x 5 mm G.I. Strip on surface or in recess for connections etc. as required with all labour and material.
Pdg. and fixing 4.00 mm dia G.I.wire on surface or in recess for loop earthing as required .
(b) Lightning conductor Galvanised iron.
Excavation of earth pit 180 cm. round at top and 90 cm. at bottom 4.5 metres deep and refilling the same in plains including supply of necessary charcoal / coke and salt mixture.
Supply and erection of 60 cm. X 60 cm. X 6 mm thick galvanised Iron plate including nacessary bolts and nuts to G.I. tape .
Supply and erection of under ground cable ,loose in existing pipe or trenches complete with necessary connections .
25 Sq. mm 3.5 Core Armoured Cable.
(X) Miscellaneous .
Supply of M.S.pipe (B-Class) for suspension rod of ceiling fan including threading if required.
15 mm dia.
Supply and erection of caution notice plate in three languages.
Supply and erection of shock restoration chart in glass frame
Supply and erection of aluminium lugs heavy duty including crimping etc. upto the entire satisfaction of the Engineer-in-charge of the work.
Wiring in 1.5 sq.mm PVC Insulated copper conductor cable in 1.6 mm thick conduit pipe.
1) Fan Point
Medium Point
Long Point
Light point
Short point
Medium Point
Long point
Twin control light point with 2 ways 5 amp single pole switch
Medium Point
Long point
Call bell point i/c MS box of size 180mmx100mmx60mm deep for call bell.
Long point
3 pin, 5 amp. Plug point i/c earthing the 3rd pin etc.
Short point
Medium Point
Long Point
3 pin,15amp plug point with 4 sqmm PVC insulated copper conductor cable i/c earthing the 3rd pin etc.
Medium Point
Long Point
Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe.
Size 1.5 sqmm (3 / 0.81mm).
Size 2.50 sqmm (3 / 1.05mm).
Size 4 sqmm (7 / 0.85mm).
Supply and erection of double door sheet steel enclosures distribution boards suitable for MCBs and ELCBs etc. recessed in wall including bonding to earth with all labour and material requared complete the job in all respect upto the entire satisfaction of the Engineer-in Charge of the work.
4-way, TP & N (Horizontal) (8+24)
8-way, TP & N (Horizontal) (8+24)
4-way, TP & N (Vertical) (8+12)
Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall / ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of work.
20 mm dia
25 mm dia
Supply and erection of MS box made of 16 gauge MS Sheet recessed in wall, with arrangement of fixing brass screws, 2 Nos. check nuts and one No. PVC bush of required size including all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of work.
with 2 coats of primer.
PAWAN KUMAR CONTRACTOR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .