Provision of CCTV cameras at Goods shed at Aligarh, Hathras Fort, Chunar, Shakteshgarh and Shankargarh stations.
PRYJ-Sig-016-2026-27
PRYJ-Sig-016-2026-27
Open
12 Months
Aligarh, Uttar Pradesh
₹0
₹3.5 L
17 Jun 2026
17 Jun 2026
1 Jul 2026
Supply of 8 port Gigabit Lite Managed PoE Layer 2 Switch supports 8 nos 01 10/100/1000BASE-T ports, along with 2 Gigabit SFP ports as per RDSO specification no. RDSO/SPN/TC/83/2020, Rev- 2.1 or latest. Make - DIGISOL / CISCO/JUNIPER or similar. Inspection by - Consignee
Supply of UTP CAT-6 cable of reputed Make- Siemen, Systemax, D-Link, Tyco, Krone, AMP, Digisol, Organic or similar. Inspection by - Consignee
Supply of power cable 3 core, 2.5 sq mm, multi strand cable as per IS 694:1990 reaffirmed 1995 or latest suitable for Railway electrification area, shall be of reputed make like Havells, Delton, LAPP, Finolex, or superior. Inspection by - RITES
Laying of Data cable/Communication cable/Power cable etc. in PVC conduit pipe with all fittings and accessories [As per site requirement]. Inspection by - Consignee
Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes etc. as per the site requirement and as per approved cable route plan. This also includes 05 laying of cables in track crossings & road crossings. (Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. Inspection by - Consignee
Supply and fixing of PVC conduit pipe 25 mm with accessories such as bend, tee, coupling, elbow, saddle, clamp, screw, PVC/ wooden plugs etc. on walls, angle or on rail of platform shelter etc. MS clamp made of 3 mm MS flat to be manufactured and supplied and fixed to clamp the PVC pipe or angle/ rail run of platform shelter. The clamp should be painted with red oxide primer over which two coats of aluminium paint to be given. Where ever necessary jumper holes to be made in wall and above PVC pipe threaded and wall to be repaired to its original condition. Inspection by - Consignee
Supply and Installation of RJ-45 patch cord, seven feet long, of reputed make like Molex or similar, with 02 no. of RJ-45 connectors for every patch cord. Inspection by - Consignee
Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO sketch No. SDO/CABLE LAYING/003, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest, alongside the track in normal soil/strata (including soft rock), conforming to distances as per cable route plan and refilling and ramming of 08 loose soil. This work includes clearing of route from bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately. The work shall be done as per the extant practice on North Central Railway and instructions of Railway Engineer at site. In case 1.2 m depth of trench is not achievable due to site conditions, specific approval of JAG/SG Officer will be required for each site where trench depth of 1.2m is not possible, only after approval of JAG/SG Officer proportionate payment can be done. Inspection by - Consignee
Cutting of all types of platforms/road crossing and trenching and excavation to a width and depth of 300 mm x 300 mm, laying of DWC/HDPE/GI pipe in the trench and refilling and 09 concreting it afterwards as per original condition. In hard rocky ground area, cables will be laid normally on layer of soft earth of 0.05 Mtr. thickness previously deposited at bottom of the trench. The cutting to be filled and finished with cement/concrete, as per the RDSO drawing no. SDO/Cable laying/008, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest. Inspection by - Consignee
Horizontal direction drilling (HDD)/Trenchless digging/machine drilling without damage to surface road /track for laying/insertion of HDPE/GI/DWC pipe. The bore shall be done at the depth 10 of minimum 1400 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. Note: - DWC/HDPE/GI Pipe Supply is not covered under this item. Contactor shall provide all material required for work and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Inspection by - Consignee
Horizontal Boring/Manual moling without damage to surface road /track for laying/insertion of DWC/GI/HDPE pipe. The bore shall be done at the depth of minimum 1400 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of 11 the road. Note: - DWC/HDPE/GI Pipe Supply is not covered under this item. Contactor shall provide all material required for work and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Payment of boring shall be made only after DWC/HDPE/GI pipe is laid in the bore. Inspection by - Consignee
Supply of basic material to construct unit maintenance free earth as per RDSO Specs. No RDSO/SPN/197 Ver. 1.0 or latest to achieve a resistance less than 1 ohm. It consists of following: (a) Copper bonded steel electrode of minimum 3.0 m long, minimum 17.0 mm dia with copper bonding thickness of minimum 250 microns and UL listed and marked = 1 no. (b) Earth enhancement material supplied in sealed bags of minimum 10 kg = 3 nos. (c) Copper strip of 150x25x6 mm, to 12 terminate earth rod = 1 no. (d) Copper strip of 300x25x6 mm (MEEB) = 1 no. (e) Copper strip of 150x25x6mm (SEEB) = 1 no. (ii) Supply of 35 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate. (minimum 10 meter) (iii) Supply of 16 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 meter) (iv) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipments to SEEB (v) Supply of copper lug sleeve for 3/16 cable Inspection by - RDSO
Installation of Unit Maintenance Free Earth to achieve a resistance less than 1 ohm as supplied under item no. 13002 of Chapter 13 of SOR. It includes (i) Digging the earth to the required depth. (ii) Insertion of electrode. (iii) Filling of earth enhancing compound (Approx.30 Kg) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for weld will be arranged by contractor. (v) This also includes CC cover 1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3-inch thickness. Cables 35 Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and busbars to various equipments. Earth electrode of 17.20 mm dia and 3.00-meter-long high tensile low carbon steel circular rods molecularly bonded with copper and outer surface (minimum copper bonding thickness of 250 microns to made requirement of under writer's laboratories (UL) 467-2007 or latest. Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300 mm x 25 mm x 6 mm for main equip- potential busbar, copper strips of 150 mm x 25 mm x 6 mm sub equip-potential busbar in relay room, power room and panel room. GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300 mm x 300 mm x 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover the earth pits. Note: The installation of this item shall be carried out by the contractor as per RDSO Spec. No. RDSO/SPN/ 197 Ver 1.0 or latest. Typical RDSO approved drawings referred in the RDSO specification document are: (i) SDO/RDSO/E&B/001 for typical installation of Earth. (ii)SDO/RDSO/E&B/002 for typical bonding and earthing connections, (iii) SDO/RDSO/E&B/003 for typical arrangement for earth resistance measurements Inspection by - Consignee
Supply of Remote service terminal (portable) fully compatible with NMS software. 14 Service terminal shall be workable from any location of the network. It should be possible to read the fault status of the STM, MUX, cross connect etc. in the network from the service terminal. Make and model to be approved by railways before supply. Inspection by - RITES
Supply of permanently lubricated HDPE duct, 40 mm outer dia, as per RDSO spec. No. RDSO/ SPN/ TC/ 45/ 2013 Rev.2 Amndt.3 or latest, along with all accessories like end caps, collars, bends, couplers etc. Inspection by - RITES
Laying of HDPE duct as per the approved cable route plan in the exavated trenches/other protected works/RCC channel etc. including all accessories like end caps, collars, 16 bends, couplers etc. The ends of the duct to be sealed with end plugs till OFC blowing is done. Important: The laying of OFC cable independently or along with Quad cable/PIJF cable in the same trench shall be governed by the RDSO drawings no. RDSO/TCDO/COP-6 [a] and RDSO/TCDO/COP-8 [a] respectively, issued vide Chapter-XIII of the Telecomm Manual. Inspection by - Consignee
Supply of 2.048 Mbps, Managed SHDSL modems, as per RDSO spec. no. RDSO/SPN/TC/80/2020, Rev.2.0 or latest with suitable connector. A pair consists of V.35 and G.703 interfaces. Inspection by - Consignee
Construction of OFC jointing pit of size 1mx1mx0.6m, using bricks, sand and cement in 18 the ratio 1:3. The thickness of the wall shall be 120 mm. The top cover shall be of concrete of thickness 75 mm with two iron handles on top of it. The pit shall be covered with sand after putting the joint enclosure. All construction material to be supplied by contractor. Inspection by - Consignee
Blowing/drawing of OFC cable in the HDPE pipe duct and protective work already 19 provided in the trench. The cable shall be laid only after the successful completion of the DIT (Duct Integrity test). The DIT should be certified by the Railway engineer at site. All the equipments/machinery required shall be arranged by the contractor. Inspection by - Consignee Above/
Supply, Installation, Testing & Commissioning of Full HD Resolution Fixed Bullet type IP Colour Camera with memory card and all accessories as per RDSO Specification No RDSO/ SPN/ TC/ 65/ 2021 Version 6.0 with Amdt. 1, 2 & 3 or latest. Inspection by - RDSO
Supply of Full HD Resolution PTZ [Pan, Tilt, Zoom] IP Colour Camera with varifocal lenses along with housing and mount with all accessories as per RDSO Specification No RDSO/ SPN/ TC/ 65/ 2021 Version 6.0 with Amdt. 1, 2 & 3 or latest. Inspection by - RDSO
Installation, Testing & Commissioning of Full HD Resolution PTZ [Pan, Tilt, Zoom] IP Colour Camera along with, Mount. All the accessories and fixing materials including mount required for this installation are to be supplied by contractor within the same cost. Inspection by - Consignee
Supply and Installation of fully functional multipurpose digital Key Board [Joy stick] compatible with PTZ camera as RDSO Specification No RDSO/ SPN/ TC/ 65/ 2021 Version 6.0 with Amdt. 1, 2 & 3 or latest. Inspection by - RDSO
Supply, Installation, Testing & Commissioning of PC Workstation hardware as per clause no. 11.0 of RDSO Spec RDSO/ SPN/ TC/ 65/ 2021 Revision 6.0 with Amdt. 1, 2 & 3 or latest for 24 Viewing, Monitoring and System Management with digital keyboard and loaded with Graphic User Interface Client Software Features per clause no, 18.2.0 of RDSO Specification No RDSO/ SPN/ TC/ 65/ 2021 Version 6.0 or latest. Software licenses conditions as per RDSO spec Clause 20.0 of RDSO Specification No RDSO/ SPN/ TC/ 65/ 2021 Version 6.0 with Amdt. 1, 2 & 3 or latest. Inspection by - RDSO
Supply, Installation, testing and commissioning of Full HD resolution Large Format display LED monitor screen size minimum 55 inch as per RDSO Specification No RDSO/ SPN/ TC/ 65/ 2021 Version 6.0 with Amdt. 1, 2 & 3 or latest Inspection by - RDSO
Supply of Server Hardware for Video Management and recording along with all accessories as per RDSO Specification No RDSO/ SPN/ TC/ 65/ 2021 Version 6.0 with Amdt. 1, 2 & 3 or latest. Inspection by - RDSO
Supply, Installation, Testing & Commissioning of Video Management Software with 27 License as per RDSO Specification No. RDSO/ SPN/ TC/ 65/ 2021 Version 6.0 with Amdt. 1, 2 & 3 or latest amendment [Per camera licence means Video Management [Viewing] at multiple locations such as Station, RPF Post & Server room by same license] Inspection by - RDSO
Supply, Installation, Testing & Commissioning of Video Recording Software with 28 License as per RDSO Specification No. RDSO/ SPN/ TC/ 65/ 2021 Version 6.0 with Amdt. 1, 2 & 3 or latest amendment [Per camera Licence means Video Recording at multiple locations such as Station, RPF Post & Server room by same license] Inspection by - RDSO
installation, Testing & Commissioning of Server for Video Management and recording along with all accessories as per RDSO Specification No RDSO/ SPN/ TC/ 65/ 2021 Version 6.0 with Amdt. 1, 2 & 3 or latest. Inspection by - Consignee
Supply, Installation, Testing & Commissioning of Core Switch [20x 10 G SFP+ ports and additional minimum 4x10G BASE-T/SFP+ combo ports] as per RDSO Specification No RDSO/ SPN/ TC/ 65/ 2021 Version 6.0 with Amdt. 1, 2 & 3 or latest. Inspection by - RDSO
Supply, Installation, Testing & Commissioning of Aggregate Switch [24x GE SFP ports and 4x10G SFP+] as RDSO Specification No RDSO/ SPN/ TC/ 65/ 2021 Version 6.0 with Amdt. 1, 2 & 3 or latest. Inspection by - RDSO
Supply of SFP-s with specification as follows- Data Rate 10 GBPS, TX/RX wavelength - 1310/ 1550 nm, Upto distance - 20 Km, Media Type - Single Mode fiber [SMF], Compatibility - Multi- vendor MSA Compatible. Inspection by - RDSO
Supply of SFP-s with specification as follows- Data Rate - 1 GBPS, TX/RX wavelength - 1310/ 1550 nm, Upto distance - 20 Km, Media Type - Single Mode fiber [SMF], Compatibility - Multi- vendor MSA Compatible. Inspection by - RDSO
Installation of single mode single fibre SFP modules compatible with the layer-3, Core, layer-2 aggregate switches taken in the schedule Inspection by - Consignee
Supply, Installation, testing, wiring & commissioning of internal storage with 35 [Hardware and Software] compatible with server with minimum 32 TB RAW usable storage capacity with all accessories as per clause 12,0 as per RDSO Specification No RDSO/ SPN/ TC/ 65/ 2021 Version 6.0 with Amdt. 1, 2 & 3 or latest. Inspection by - RDSO
Supply of Armoured Outdoor CAT-6 cable [305 Mtrs. Roll] as per ANSI/TIA 568-C.2 & ISO /IEC 11801 2nd Edition or latest. Inspection by-Consignee
Supply of 12 fiber OFC - Armoured. Inspection by - Consignee
Supply of 19" 42 U size floor mountable covered network racks with complete fixing 38 accessories. Front door of transparent type with lock and key arrangement. Rack to be fitted with (1) trays - 1Nos (2) 6x15A/5A SURGE protected vertical power socket (minimum 2 nos), (3) cable manager / organiser strip- 2Nos (4) cooling exhaust fans (2Nos)in one tray of 230V AC working. Inspection by - Consignee
Installation of 19" 42 U size floor mountable covered network racks with complete fixing accessories and fixing materials required for this installation are to be supplied by contractor within the same cost. Inspection by - Consignee
Supply, installation and fixing of 6U Outdoor IP66 rack with 1 PDU, 500 mm depth and other accessories. Inspection by - Consignee
Supply, erection, foundation, fixing & commissioning of Hot Dip Galvanised octagonal pole 5 Mtrs. Long confirming to IS:2629/BSEN ISO: 1416 latest version, Manufacturer should be ISO certified firm. Inspection by - Consignee
Supply, fixing, termination, indoor wiring, testing and commissioning of PVC Flexible Pipe dia 1 inch Inspection by - Consignee
Supply, termination, testing and commissioning of RJ-45 Connector of reputed make. Inspection by - Consignee
Supply of Armoured optical Patch Cords LC- SC[APC]/SC[APC]-SC[APC] or as per site requirement- 3 mtrs. Inspection by - Consignee
Supply of Armoured optical Patch Cords LC- SC[APC]/SC[APC]-SC[APC] or as per site requirement [1 Mtr]. Inspection by - Consignee
Supply of Armoured optical Patch Cords LC-LC/ SC[APC]-SC[APC] or as per site requirement- 5 mtrs. Inspection by - Consignee
Preparation of drawing mentioning the location of cameras wiring diagrams showing clearly the STP CAT-6, OFC, Power cable OTDR test reports of OFC cable, earth resistance test reports, 47 technical details of servers, switches, work stations, media convertors, storages and submission In soft as well 3 sets in printed to the consignee. A diagram of camera location either in pictorial view or in descriptive manner as decided by the officer in charge should be prepared on a suitable sheet and displayed in RPF CCTV control room. Inspection by - Consignee
Supply and installation of miniature circuit breaker [MCB], 32 Ampere. Make - Anchor or similar as per site requirement in suitable PVC/ Metallic Box. Inspection by - Consignee
Supply of Miniature Circuit Breaker, 3 Ampere, 2 pole as per ISI Standard as per site requirement. Make - Schneider, L&T, Havells or similar. Inspection by - Consignee
Supply of Fibre Distribution Management system [FDMS]/LIU for 24 Fiber complete with all accessories with patch cord and pigtail. Make- R&M, Rackom, D-Link or similar. Inspection by - Consignee
Installation and commissioning of Fibre Distribution Management system [FDMS] for 24 Fiber complete with all accessories. Inspection by - Consignee
Supply and fixing of 12 port FDMS/ LIU with connectors. [Pigtails and other miscellaneous materials required for the work shall be supplied by the contractor]. Make- R&M, Rackom, D-Link or similar. Inspection by - Consignee
Fiber splicing/termination and testing of spliced joint of all fibers of 12 F OFC Inspection by - Consignee
Supply, Installation, testing and Commissioning of on line UPS 5 KVA, with 240 minutes battery backup on full load with battery trolley. Make- APC, Luminious, Microtec, Liebert, Numeric or similar. Backup time for number of batteries and AH will be calculated as per calculation given as follows-Battery AH = VA X backup(Hrs)/Total battery voltage. Inspection by - RITES
Supply of self supporting heavy duty Aluminium flat step Ladder 10 Feet height as per the instruction of consignee. Inspection by - Consignee
Supply, installation, testing & commissioning of Layer-2 managed Switch [8 Port 10/100 BASE-T and 2 SFP 1G uplink ports] as per RDSO Specification No RDSO/ SPN/ TC/ 65/ 2021 Version 6.0 with Amdt. 1, 2 & 3 or latest. Inspection by - RDSO
Supply of non-executive open standard SIP phone. Inspection by - Consignee
Supply of STP CAT-6 cable and all the accessories required for installation (should be compliant with latest EIA/TIA-568-B.2-1 standard for CAT 6 cable). Make : Siemen/ Systemax / D-Link/ Tyco/ Krone/ AMP/Digisol/organic or similar. Inspection by - Consignee
Supply of Miniature Circuit Breaker, 6 Ampere, 1 pole as per ISI Standard as per site requirement. Make - Schneider, L&T, Havells or similar. Inspection by-Consignee
Supply of Miniature Circuit Breaker, 16 Ampere, 2 pole as per ISI Standard as per site requirement. Make -Schneider, L&T, Havells or similar. Inspection by - Consignee
Supply of straight joint enclosure [SJC] complete with all accessories of 48 Fiber OFC and splicing of 2 X 48 F OFC. Inspection by - Consignee
Supply of Fibre Distribution Management system [FDMS]/LIU for 48 Fiber cable with all accessories. This also include supply of installation accessories. Make- R&M, Rackom, D-Link or similar. Inspection by - Consignee
Installation, splicing and commissioning of Fibre Distribution Management system [FDMS] for 48 Fiber cable. this includes testing of fibres in the section/block. Inspection by - Consignee
Supply, installation and Fixing of 19 inch 9 U Racks with Front Glass Door, 06 Socket Power DB with MCB, 02 Fan-Fan Tray, Cable Manager , Hardware Packet , Earthing etc. with required accessories for mounting the equipment. Inspection by - Consignee
Supply of Media Converter [OFC to Ethernet] of make D-Link or MROTEK or DAX or similar as per RDSO Spec No.RDSO/SPN/TC/103/2013 Rev 2.0 or latest. Inspection by - Consignee
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC-CorrectionSlip1-2-3-4-5-6-7-8-9-10-11_compressed.pdf
ATTACHMENT
2023UndertakingtheworkoflayingundergroundSignTelecablesandEnggdiggingwork24- JPO 05 2023
ATTACHMENT
LASTFYDECLARATION.pdf
ATTACHMENT
BankGuaranteeforBidsecurityformatAnnVIA.pdf
ATTACHMENT
TenderDoc22_5.pdf
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27-04-22.pdf
ATTACHMENT
AnnexureAcl.pdf
ATTACHMENT
JPO-05-2023UndertakingtheworkoflayingundergroundSignTelecablesandEnggdiggingwork24-1-24.pdf
ATTACHMENT
Download all tender documents and submit your bid