GE NEW DELHI
GE NEW DELHI, SP MARG NAR ABHM GATE NO 5
REPAIR/ COMPREHENSIVE MAINT OF 910 KVA DG SETS AND AC PLANT AT NCN DATA CENTRE UNDER GE NEW DELHI
2023_MES_624309_1
NIT No GE/ND-69/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE NEW DELHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE NEW DELHI
₹76,928
Yes
15 Jan 2024
20 Oct 2023
25 Nov 2023
20 Oct 2023
23 Nov 2023
10 Nov 2023
Amount
Comprehensive maintenance and repair of 910 KVA - 02 NOs DG Set including replacement of defective parts/ fitting inclunding all required electrical and mechanical Spares required for smooth functioning of DG sets during the entire contract period. Make- Cummins Note:1. (01 service visit monthly + unlimited Breakdown visit If require during the contract period) and covered panel side, contactor, relay, battery charger, under voltage relay, over voltage relay, and engine side fuel filter and ring, LO filter,oil filter, air filter , fit insrt with O ring,fit element with O ring,self starter, hose pipe set, clip, controller etc. for each DG Sets. 2.Contractor is required to enter in to MOU with M/s Cummins Pvt Ltd. The contractor shall upload scanned copy of MOU with M/s Cummins Pvt Ltd alongwith his application in Cover No 01 and also submit hard copy of MOU with his application before the last date for bid submission failing which Cover 02 shall not be opened and No claim what so ever on this account shall be entertained. The service Engineer from M/s Cummins Pvt Ltd (original OEM) will visit the System minimum one time in a month and will submit inspection report to the Engr-in-Charge. Necessary repair action will be taken immediately if/as required and periodical maintenance of DG Sets will be carried out by contactor as per technical instructions OEM. 3.Spare parts to be replaced as listed in sch 'A' to be measured and paid seperately as supply only. Fixing charge is deemed to be included in item No. 01. 4. Any items not covered under as supply only shall be deemed to be included in this section for the smooth functioning of DG Sets and the contractor may quote the rate accordingly. Contractor is expected to inspect the DG Sets before quoting the rate. 5. Contractor shall be attending complaints round the clock i.e. 24 hrs. If contractor is not able to rectify the complaint, panelty shall be charged as given below:- (a) upto 12 Hrs- NIL (b) 13 to 24 Hrs - Rs 1000/- (c) Subsequency for every days - Rs 2000/- per day
Supply only in replacement following Spare parts of DG Set 910 KVA Make :Cummins installed at NCN Data Centre complete all as specified and as directed:-
Separator
Filter
Kit Air cleaner elements (K,QSK.V series)
Inhibitor
Foil sealed test strips CC2602B
Indicator
Valvoline premium blue
Material and labour for Cleaning of fuel tank of 910 KVA DG Set made out of MS sheet of capacity 1000 litre capacity approx by draining out fuel in a separate container, taking out all silt/ dirt deposition inside the tank, cleaning it completely by manual mean and necessary T&P and refitting and connecting with fuel pipes with DG sets all as per site requirement complete all as specified and as directed.
Comprehensive maintenance and repair of 150 KVA - 02 NOs UPS including replacement of defective parts/ fitting inclunding all required electrical and mechanical Spares required for smooth functioning of DG sets during the entire contract period. Make- ABB
Comprehensive maintenance and repair of 60 KVA - 01 NOs UPS including replacement of defective parts/ fitting inclunding all required electrical and mechanical Spares required for smooth functioning of DG sets during the entire contract period. Make- ABB
Comprehensive maintenance and repair of 60 KVA - 01 NOs UPS including replacement of defective parts/ fitting inclunding all required electrical and mechanical Spares required for smooth functioning of DG sets during the entire contract period. Make- Delta
Note for item no 05 to 07-. •1.(a) Contractor shall ensure UPS are working properly at NCN Data Cenre and no call pending in branch. (b) Checking of power supply source for proper grounding/earthing and safety of equipment. (c) Ensuring that the covers, screws, switches etc. are firmly fastened in respect of each equipment. (d) checking of voltage level, periodically checking earthing of the UPS, lodging complaints with OEM in case of UPS is down (e) Repair/Replacement of card (f) The quoted rate also include (01 service visit monthly + unlimited Breakdown visit If require during the contract period) and covered AC Capacitor,DC Capacitor,switchgear,power module etc. 2.Contractor is required to enter in to MOU with M/s ABB/Delta or authorised dealer. The service Engineer from M/s ABB/Delta (original OEM) will visit the System minimum one time in a month and will submit inspection report to the Engr-in-Charge. Necessary repair action will be taken immediately if/as required and periodical maintenance of UPS will be carried out by contactor as per technical instructions OEM. 3. Contractor shall be attending complaints round the clock i.e. 24 hrs. If contractor is not able to rectify the complaint, panelty shall be charged as given below:- (a) upto 12 Hrs- NIL (b) 13 to 24 Hrs - Rs 1000/- (c) Subsequency for every days - Rs 2000/- per day
S&F in replacement of battery 200 Ah,12 Volts maintencance free including battery termail alongwith connectiing wire of suitable gauge upto 2 mtr length min as required on site all as specified and directed by Engineer-in-Charge. Make/model :- As per sample
S&F in replacement of battery 100 Ah,12 Volts maintencance free including battery termail alongwith connectiing wire of suitable gauge upto 2 mtr length min as required on site all as specified and directed by Engineer-in-Charge. Make/model :- As per sample
S&F in replacement of battery 42 Ah,12 Volts maintencance free including battery termail alongwith connectiing wire of suitable gauge upto 2 mtr length min as required on site all as specified and directed by Engineer-in-Charge. Make/model :- As per sample
Comprehensive/ Routine maintenance of Scroll type Chiller plant for following size and capacity. (Make: Swegon Blue Box) (A) OUT DOOR UNIT 22 TR:- Air cooled system - 04 Nos (B) IN DOOR UNIT ( Liquid cooling package) :- cooling capacity 10 KW - 08 Nos (C ) IN DOOR UNIT (Air handling Unit):- Capacity (500 CFM ) - 04 Nos.
Note:- 1 (a) Three preventive Maintenance Calls shall be provided during the contract period of Nine Month. They shall be as per dates and time provided by user during normal working hours ( Monday to Friday between 9:30 AM to 6:00 PM). (b)Checking the chiller system, comprising of the refrigeration plant, and their respective motors and starters. (c) Health checkup of the system including spare part replacement (Labor) if any parts found faulty at the time of maintenance by our service engineer. (d) Checking / rectifying of alignments of couplings in direct driven components. (e) Free replacement of defective / worn out parts with new or repaired parts for compressor will be based on our assessment. (f) Inspection of the safety and operating controls for proper operation. (g) Leak testing and rectifying leaks in the refrigeration system if any at the time of maintenance by our service engineer. (h) Checking the plant performance in relation to indoor room temperatures. (i) Checking the System Refrigerant Pressures, Water Pressure, Delta Pressures, and Temperatures etc. Water flow if required on the Condenser and Evaporator will be checked. (j) Checking the Input Voltage and component amps etc. (k) Compressor will be checked for its proper working/ readjustment if necessary. Attending break down calls and trouble diagnosis. (l) Water cleaning of condenser coil fins in air cooled condenser systems. (m) Repairs / Overhaul of the components of the plant if possible to avoid replacement. (n) Checking the performance of the air cooled condenser fans. (o) Microprocessor control panel, control boards, transducers of packaged chillers/ condensing unit will be checked for their correctness and replaced if necessary. (p)Advising plant operating personnel about possible improvement in method of operation.
2. The quoted rate include comprehensive maintenance, including attending All major/minor breakdown like repair/replacement of compressor ,fan motor,replacement of defective/wornout parts,leak testing and rectifying leak,De-scaling of heat exchanger if requirtedrefrigerant piping,ducting pipe,duct insulation,gas chqarging. The quoted rate include the periodical washing of filters as per OEM recommendations. , replacement/ rewinding of motors and pumps, electrical contactor and relays, repair and replacement of filters etc, required for smooth operation of Chiller plant system shall be provide by contractor at his own cost as per the OEM instructions. 3. The qouted rates also includes cost of spares and labour (as recommended by the OEM during inspection/analysis report) shall be provided by the contractor at no extra cost and rate for the same shall deemed to be included in the unit rates of item as above. 4. Cost of refrigerant gas and compressor oil will be included in quoted rate. 5. Contractor is required to enter in to MOU with M/S Swegon Blue box Pvt Ltd. The contractor shall upload scanned copy of MOU with M/S Swegon Blue box Pvt Ltd alongwith his application in Cover No 01 and also submit hard copy of MOU with his application before the last date for bid submission failing which Cover 02 shall not be opened and No claim what so ever on this account shall be entertained. The service Engineer from M/S Swegon Blue box Pvt Ltd (original OEM) will visit the System minimum one time in a month and will submit inspection report to the Engr-in-Charge. Necessary repair action will be taken immediately if/as required and periodical maintenance of plant will be carried out by contactor as per technical instructions OEM. 6. Contractor shall be attending complaints round the clock i.e. 24 hrs. If contractor is not able to rectify the complaint, panelty shall be charged as given below:- (a) upto 12 Hrs- NIL (b) 13 to 24 Hrs - Rs 500/- per hours (c) Subsequency for every days - Rs 10000/- per day
Comprehensive/ Routine maintenance of VRF/VRV type Acs for following size and capacity. (Make: Hitachi) (A) OUT DOOR UNIT 24 HP:- Air cooled VRF/VRV system - 01 Nos OUT DOOR UNIT 20 HP:- Air cooled VRF/VRV system - 02 Nos OUT DOOR UNIT 16 HP:- Air cooled VRF/VRV system - 01 Nos OUT DOOR UNIT 14 HP:- Air cooled VRF/VRV system - 02 Nos (B) IN DOOR UNIT CASETTE TYPE :- (i) 1.14 TR - 05 Nos (ii) 1.17 TR- 02 Nos (iii)1.6 TR- 02 Nos (iv) 2.0 TR- 15 Nos (v) 3.2 TR- 03 Nos (C ) IN DOOR UNIT DUCTABLE TYPE:- 8.3 TR - 04 Nos.
Note:-1 (a) Three preventive Maintenance Calls shall be provided during the contract period of Nine Month. They shall be as per dates and time provided by user during normal working hours ( Monday to Friday between 9:30 AM to 6:00 PM). (b) Cleaning up of Unit, Air Filter, cooling coil & condenser coil. (If required with water). (c) Cleaning of Humidifier bottle, electrodes, water supply strainer and drain inside the machine. (d) Checking of drive belt & replace if necessary. (e) Lubrication of bearings if necessary. (f) Checking up of operation of Unit, Controller & condenser. (g) Combing of fins of condenser & Evaporator coil if necessary. (h) Measurement of current of each individual equipment. (i) Checking of all the overload relay settings. (j) Checking of all electrical components for loose connections and tightening if necessary. (k) Checking of refrigeration piping for any gas leakages. (l) Checking of refrigeration system and pressure readings. (m) Checking of pulleys, Motor mounts, Condenser fan mounts etc. (n) Checking of panel insulation. (o) Checking of temperature readings. (p) Checking of Microprocessor controllers for operation.
2. The quoted rate include comprehensive maintenance, including attending All major breakdown like repair/replacement ofcompressor ,fan motor,PCB,magnetic switch,transformer,refrigerant charging,air filter,evaporating coil/condensing coil, replacement of electrical control panels , Remote control etc,gas chqarging. The quoted rate include the periodical washing of filters as per OEM recommendations. Repairing and replacement of expansion valve, safety devices and valves, replacement/ rewinding of motors and pumps, electrical contactor and relays, repair and replacement of filters etc, and other routine items such as Refrigerant gas, compressor oil and grease, Lugs, Gland, Wires and cables etc required for smooth operation of VRF/VRV system shall be provide by contractor at his own cost as per the OEM instructions. 3. The qouted rates also includes cost of spares and labour (as recommended by the OEM during inspection/analysis report) shall be provided by the contractor at no extra cost and rate for the same shall deemed to be included in the unit rates of item as above. 4. Contractor is required to enter in to MOU with M/S Hitachi or authprised dealer of Hitachi Company. The contractor shall upload submit scanned copy of MOU with M/S Hitachi alongwith his application in Cover No 01 and also submit hard copy of MOU with his application before the last date for bid submission failing which Cover 2 shall not be opened and No claim what so ever on this account shall be entertained. The service Engineer from M/S Hitachi will visit the VRV/VRF System minimum one time in a month and will submit inspection report to the Engr-in-Charge. Necessary repair action will be taken immediately if/as required and periodical maintenance of plant will be carried out by contactor as per technical instructions OEM. 5.Contractor shall be attending complaints round the clock i.e. 24 hrs. If contractor is not able to rectify the complaint, panelty shall be charged as given below:- (a) upto 12 Hrs- NIL (b) 13 to 24 Hrs - Rs 1000/- (c) Subsequency for every days - Rs 2000/- per day
Comprehensive/ Routine maintenance of PAC System following capacity. (Make: Swegon Blue Box) PAC Capacity (5 TR) - 03 Nos
Note:- 1 (a) Three preventive Maintenance Calls shall be provided during the contract period of Nine Month. They shall be as per dates and time provided by user during normal working hours ( Monday to Friday between 9:30 AM to 6:00 PM). (b) Checking the Air conditioning system, comprising of the refrigeration plant, air cooled condensers and their respective motors and starters. (c) Health check up of the system including spare part replacement (Labor) if any parts found faulty at the time of maintenance by our service engineer. (d) Checking / rectifying of alignments of couplings in direct driven components. (e) nspection of the safety and operating controls for proper operation. (f) Leak testing and rectifying leaks in the refrigeration system if any at the time of maintenance by our service engineer. (g) Checking the plant performance in relation to indoor room temperatures. (h)Checking the System operating pressure and desired super heat. (i) Checking the Voltage and component amps. (j) Attending break down calls and trouble diagnosis. (k) Water cleaning of condenser coil fins in air cooled condenser systems. (l) Repairs / Overhaul of the components of the plant if possible to avoid replacement. (m) Checking the performance of the air cooled condenser fans. (n) Checking the Microprocessor Parameter settings in respect to model configuration. (o)Advising plant operating personnel about possible improvement in method of operation.
2. The quoted rate include comprehensive maintenance, including attending All major/minor breakdown like repair/replacement of compressor ,fan motor,replacement of defective/wornout parts,Repair/replacement of condenser and cooling coils,sheet metal parts,return air filter,humidifier bottle etc,and any other part required for smooth operation of PAC system shall be provide by contractor at his own cost as per the OEM instructions. 3. The qouted rates also includes cost of spares and labour (as recommended by the OEM during inspection/analysis report) shall be provided by the contractor at no extra cost and rate for the same shall deemed to be included in the unit rates of item as above. 4. Contractor is required to enter in to MOU with M/S Swegon Blue box Pvt Ltd. The contractor shall upload scanned copy of MOU with M/S Swegon Blue box Pvt Ltd alongwith his application in Cover No 01 and also submit hard copy of MOU with his application before the last date for bid submission failing which Cover 2 shall not be opened and No claim what so ever on this account shall be entertained. The service Engineer from M/S Swegon Blue box Pvt Ltd (original OEM) will visit the System minimum one time in a month and will submit inspection report to the Engr-in-Charge. Necessary repair action will be taken immediately if/as required and periodical maintenance of plant will be carried out by contactor as per technical instructions OEM. 5. Contractor shall be attending complaints round the clock i.e. 24 hrs. If contractor is not able to rectify the complaint, panelty shall be charged as given below:- (a) upto 12 Hrs- NIL (b) 13 to 24 Hrs - Rs 1000/- (c) Subsequency for every days - Rs 2000/- per day
SNOWY ENGINEERING INC
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .