Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.1 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹9.0 L+₹1.9 L (26.8%)Rejected-Finance | 2 | Rejected-Finance Not Lowest |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
5 Mar 2021, 6:00 pmClosed
Garrison Engineer Abohar
Garrison Engineer Abohar Pin-152116
Repair/maint and replacement of UNSV CI/DI/GI pipe lines of OTM and Md Accn at Mil Stn Abohar
2021_MES_412752_2
GE ABH-46/20-21
Open Tender
Civil Works
Item Rate
180 days
Abohar Mil Stn
MES Registered Contractor enlisted in class E Category a (ii) having deposited standing security of Rs 50000 with departments. Contractors not registered in MES should meet the MES enlistment criteria corresponding to appropriate class and category
5 documents required · 5 mandatory
₹500
Garrison Engineer Abohar
₹20,000
Yes
26 Mar 2021
19 Feb 2021
8 Mar 2021
19 Feb 2021
5 Mar 2021
20 Feb 2021
Amount
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundations or laying cables/pipes etc. and getting out in soft/loose soil all as specified and directed by Engr-in-charge.
Returning, filling in including spreading leveling, watering and well ramming in layers of Soft/loose soil not exceeding 25 cm thick complete all as specifiedand directed by Engr-in-charge.
Removal of excavated material to a distance not exc 50 mtr and depositing where directed at level not exc 1.5 mtr above the starting point complete all as specified and directed.by Engr-in-charge
Disconnecting electric connection dismantling / taking up electric motor 3 phase, 440 volts, 50 Hz of capacity 12.5/15 HP, from existing foundation coupled with pumping set removing of workshop for repair , dismantling/opening for required repair work including replacement of stainless shaft , ball bearing of motors and pumps ( 04 nos), key rubber shaft coupling ,impeller, varnishing , reassembling and bringing back to installation and making functional after refixing on existing foundation , testing on full load and commissioning complete all as specified and directed by Engr-in-charge.
Disconnecting electric connection dismantling / taking up electric motor 3 phase, 440 volts, 50 Hz of capacity 40 HP, 2000 GPH, 60 mtr head, from existing foundation coupled with pumping set removing of workshop for repair , dismantling/opening for required repair work including rewinding the motor with and including copper winding wire of existing gauge and weight and replacement of stainless shaft , ball bearing of motors and pumps ( 04 nos), key rubber shaft coupling ,impeller, varnishing , reassembling and bringing back to installation and making functional after refixing on existing foundation , testing on full load and commissioning complete all as specified and directed by Engr-in-charge.Make of winding wire shall be ATLAS/Devi dayal/BPL
Disconnecting electric connection dismantling / taking up electric motor and monoblock pump 3 phase, 440 volts, 50 Hz of capacity 10 HP from existing foundation coupled with pumping set removing to workshop for repair , dismantling/opening for required repair work including rewinding the motor with and including copper winding wire of existing gauge and weight and replacement of stainless shaft , ball bearing of motors and pumps ( 04 nos), key rubber shaft coupling ,impeller, varnishing reassembling and bringing back to installation and making functional after refixing on existing foundation , testing on full load and commissioning complete all as specified and directed by Engr-in-charge.Make of winding wireshall be ATLAS/Devi dayal/ BPL
Disconnecting electric connection dismantling / taking out non clog/ monoblock centrifugal submersible pumping set 3 phase, 440 volts, 50 Hz of capacity 5 HP from existing foundation coupled with pumping set removing to workshop for repair , dismantling/opening for required repair work including rewinding the motor with and including copper winding wire of existing gauge and weight and replacement of stainless shaft , ball bearing shaft key, mechanical seal , varnishing reassembling and bringing back to installation and making functional after refixing on existing foundation , testing on full load and commissioning complete all as specified and directed by Engr-in-charge.Make of winding wireshall be ATLAS/Devi dayal/ BPL
Disconnecting electric connection dismantling / taking out submersible pumping set 3 phase, 440 volts, 50 Hz of capacity 10 HP from existing foundation coupled with pumping set removing to workshop for repair , dismantling/opening for required repair work including rewinding the motor with and including copper winding wire of existing gauge and weight and replacement of stainless shaft , ball bearing shaft key, mechanical seal , varnishing reassembling and bringing back to installation and making functional after refixing on existing foundation , testing on full load and commissioning complete all as specified and directed by Engr-in-charge.Make of winding wireshall be ATLAS/Devi dayal/ BPL
S&F run lead joint suitable for 150 mm bore spigot and socketed pipes and fittings complete all as specified and directed by Engr-in-charge.
S&F run lead joint suitable for 100 mm bore spigot and socketed pipes and fittings complete all as specified and directed by Engr-in-charge.
S & F 15 mm bore medium grade steel tubes galvanized with all fittings and laid in trenches all as specified and directed by Engr-in-charge.
S & F 20 mm bore medium grade steel tubes galvanized with all fittings and laid in trenches all as specified and directed by Engr-in-charge.
S & F 25 mm bore medium grade steel tubes galvanized with all fittings and laid in trenches all as specified and directed by Engr-in-charge.
S & F 40 mm bore medium grade steel tubes galvanized with all fittings and laid in trenches all as specified and directed by Engr-in-charge.
S & F 50 mm bore medium grade steel tubes galvanized with all fittings and laid in trenches all as specified and directed by Engr-in-charge.
S & F 80 mm bore medium grade steel tubes galvanized with all fittings and laid in trenches all as specified and directed by Engr-in-charge.
S & F in replacement of gun metal, globe or gate valve with iron wheel head secrewed both ends for iron pipes 80 mm bore as in repairs complete all as specified and directed by Engr-in-charge.
S & F in replacement of gun meteal, globe or gate valve with iron wheel head secrewed both ends for iron pipes 50 mm bore as in repairs complete all as specified and directed by Engr-in-charge.
S & F in replacement of gun metal, globe or gate valve with iron wheel head secrewed both ends for iron pipes 40 mm bore as in repairs complete all as specified and directed by Engr-in-charge.
S & F in replacement of gun metal, globe or gate valve with iron wheel head secrewed both ends for iron pipes 25 mm bore as in repairs complete all as specified and directed by Engr-in-charge.
S & F in replacement of gun metal, globe or gate valve with iron wheel head secrewed both ends for iron pipes 20 mm bore as in repairs complete all as specified and directed by Engr-in-charge.
S & F in replacement of gun metal, globe or gate valve with iron wheel head secrewed both ends for iron pipes 15 mm bore as in repairs complete all as specified and directed by Engr-in-charge.
S & F in repair ball brass valve 20 mm bore dia high pressure with polythene float and fly nuts complete secrewed with iron pipe and fixed all as specified and directed by Engr-in-charge.
Construction of valve pit inside dimensions 90 cm x 90 cm x 90 cm deep from the top of surface including cover of MS sheet 3.15 thick and Angle iron 40mm x 40mm x 6mm with hinges and locking arrangement including painting with two coats of Synthetic enamelled paint over a coat of red oxide and grouting to PCC 1:2:4 type B-01 and brick work in CM 1:4 plastering in cement mortar 1:3 foundation concrete 1:3:6 all as per existing pattern and as specified and directed by Engr-in-charge ( Earth work shall be measured and paid separately)
Supply and fixing in repair /replacement sluice valve flanged type rating PN 1.6 size 200 mm bore confirming to IS14846 with necessary gasket , nuts, bolts and washers etc. and jointing including testing for leakage complete all as specified and directed by Engr-in-charge.
Supply and fixing in repair /replacement sluice valve flanged type rating PN 1.6 size 150 mm bore confirming to IS14846 with necessary gasket , nuts, bolts and washers etc. and jointing including testing for leakage complete all as specified and directed by Engr-in-charge.
Supply and fixing in repair /replacement sluice valve flanged type rating PN 1.6 size 100 mm bore confirming to IS14846 with necessary gasket , nuts, bolts and washers etc. and jointing including testing for leakage complete all as specified and directed by Engr-in-charge.
Supply and fixing in repair /replacement Non Return valve ( NRV) flanged type rating PN 1.6 size 150 mm bore confirming to IS14846 with necessary gasket , nuts, bolts and washers etc. and jointing including testing for leakage complete all as specified and directed by Engr-in-charge.
Supplying, laying, jointing/testing and commissioning and testing DI pipes with tyton joint s of spigot and socket ends centrifugally cast ( Spun0 class "K"- 9 confirming to IS - 8329-2000 in any length of size 100 mm bore laid in trenches complete all as specified and directed by Engr-in-charge.
Supplying, laying, jointing/testing and commissioning and testing DI pipes with tyton joint s of spigot and socket ends centrifugally cast ( Spun0 class "K"- 9 confirming to IS - 8329-2000 in any length of size 250 mm bore laid in trenches complete all as specified and directed by Engr-in-charge.
Supplying, laying, jointing/testing and commissioning and testing DI pipes with tyton joint s of spigot and socket ends centrifugally cast ( Spun0 class "K"- 9 confirming to IS - 8329-2000 in any length of size 200 mm bore laid in trenches complete all as specified and directed by Engr-in-charge.
Supplying, laying, jointing/testing and commissioning and testing DI pipes with tyton joint s of spigot and socket ends centrifugally cast ( Spun0 class "K"- 9 confirming to IS - 8329-2000 in any length of size 150 mm bore laid in trenches complete all as specified and directed by Engr-in-charge.
M & L for DI fittings confirming to IS-9523-2K for DI Spigot and socketed pipes like bends (any type radius and angle) straight , taper bend, increasing , decreasing double socket etc. ) tee pieces single branch "Y" junction double branch cross collars caps and plugs etc. complete all as specified and directed by Engr - in-charge. Note for DI fittings - The weight of the fitting for the purpose of payment shall be actual weight of the fitting or as specified in IS code whichever is less.
M & L petty rapairs to water supply pipe line for removing leakage / blockage of GI pipe 50 mm bore by providing gasket /socket/tee/elbow/bend including washers, nuts,bolts etc. including earth work as required complete including earth work all as specified and directed by Engr-in-charge.
M & L petty rapairs to water supply pipe line for removing leakage / blockage of GI pipe 100 mm bore by providing gasket /socket/tee/elbow/bend including washers, nuts,bolts etc. including earth work as required complete including earth work all as specified and directed by Engr-in-charge.
M & L petty rapairs to water supply pipe line for emoving leakage / blockage of CI/DI pipe 80 mm to 150 mm bore by providing gasket /socket/tee/elbow/bend including washers, nuts,bolts etc. including earth work as required complete including earth work all as specified and directed by Engr-in-charge.
M & L petty rapairs to water supply pipe line for removing leakage / blockage of CI/DI pipe 200 mm to 300 bore by providing gasket /socket/tee/elbow/bend including washers, nuts,bolts and Lead etc. including earth work as required complete including earth work all as specified and directed by Engr-in-charge.
Supply and fixing of gilan packing for pump and sluice valve of size 6 mm, 8mm,10mm
Supply and fixing of tier coupling for pump set of size TC-10
Supply and fixing of tier coupling for pump set of size TC-11
Supply and fixing of tier coupling for pump set of size TC-12
Supply and fixing of tier coupling for pump set of size TC-14
Supply and fixing of tier coupling for pump set of size TC-15
Supply and fixing of tier coupling for pump set of size TC-18
Supply and fixing of power contractor AC 3 80 Amp cat part No. 850181 Make : Indoasian
Supply and fixing of power contractor AC 3 25 Amp cat part No. 850135 Make : Indoasian
Supply and fixing of power contractor AC 3 95 Amp cat part No. 850191 Make : Indoasian
SUDESH ENTREPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .