Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 LAccepted-Finance | L1 | Accepted-Finance Lowest bidder | |
| 2 | L2₹1.9 L+₹1,100 (0.57%)Rejected-Finance WZ 831 NANGAL RAYA PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹1.9 L+₹1,656 (0.86%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹1.9 L+₹2,700 (1.41%)Rejected-Finance 1202 SAI PROVISO DHNISHT PLOT NO 72 73 SECTOR 20 KOPARKHAIRANE NAVI MUMBAI | THANE | MAHARASHTRA | 400601 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹2.0 L+₹4,980 (2.60%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | Tushar engineers L2 | R.P. Enterprises L1 | Ashok Enterprises L4 | Perfect Office Solutions L5 | Nakul Enterprises L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | 1.0 Material & labour for opening / taking down radiator of DG set and cleaning
descaling using air compressor and cleaning with detergent etc and examining
of water leakage of the same after cleaning , descaling and repairing of leak
age, if any, using welding/brazing etc including replacement of all connecting
parts if damage i.e. radiator hose pipe with clamp, bolt, nut, washer, rubber
bush, packing material etc and re-assembling the radiator, fitting with DG set
properly in original position, checking the alignment, making proper hose
connection, testing for smooth operation complete all as directed.
Note :
1. The cost of replaced spare parts is deemed to be included in quoted rates
2. The cost of transportation (to and fro) for all kind of necessary equipment
T&P shall be arranged/brought by contractor to complete the job at site and
no extra cost shall be paid to the contractor in this effect.
1.01 capacity of 200 KVA(Tigrish Road)- 01 No
1.02 capacity of 250 KVA (Tigrish Road)- 01 No
1.03 capacity of 250 KVA (Behind Butchury Map Accn ) - 02 Nos
2.0 Supply and fixing in replacement of Megnetic pickup Sensor suitable for
250 KVA CUMMINS . DG set connecting with panel circuit, starting and testing
on load all as specified and directed. - 02 Nos
3.0 Supply and fixing in replacement of Automatic Voltage regulator sutable
for 200 KVA -250 KAV DG connecting with Panel circuit,starting and testing
on load with all the parameters for safety protection and running suitable for
the existing DG set of Make: Cummins / CG. - 02 Nos
4.0 Supply and fixing in replacement of Battery 12 V 150 Ah suitable for the
existing DG set of Make: Exide / Amron. - 02 Nos
5.0 Supply and fixing in replacement of Battery 12 V 100 Ah suitable for the
existing DG set of Make: Exide / Amron. -02 Nos
6.0 Supply and fixing in replacement of Lubricant oil pump Assembly sutable
for 200 KVA -250 KAV DG with all connecting parts suitable for the existing
DG set Make: Cummins / CG. - 01 Nos | 1 | Job | 1,92,900 ₹1,92,900 | 1,91,800 ₹1,91,800 Lowest | 1,94,500 ₹1,94,500 | 1,96,780 ₹1,96,780 | 1,93,456 ₹1,93,456 |
Tender Value
Refer Docs
Closing Date
22 Dec 2025, 6:00 pmClosed
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
REPAIR REPLACEMENT OF DEFECTIVE PARTS DG SET INSTALLED AT TIGRISH ROAD BEHIND BUTCHURY MAP ACCN UNDER GE U P AND M DELHI CANTT
2025_MES_744626_1
GE(U)/PM/3011/B/JO/111/E3
Limited
Miscellaneous Works
Piece-work
30 days
Delhi CAntt
PLEASE REFER NOTICE INVITING QUOTATION
1 document required · 1 mandatory
₹0
Exempted
27 Dec 2025
15 Dec 2025
24 Dec 2025
15 Dec 2025
22 Dec 2025
15 Dec 2025
Amount
1.0 Material & labour for opening / taking down radiator of DG set and cleaning descaling using air compressor and cleaning with detergent etc and examining of water leakage of the same after cleaning , descaling and repairing of leak age, if any, using welding/brazing etc including replacement of all connecting parts if damage i.e. radiator hose pipe with clamp, bolt, nut, washer, rubber bush, packing material etc and re-assembling the radiator, fitting with DG set properly in original position, checking the alignment, making proper hose connection, testing for smooth operation complete all as directed. Note : 1. The cost of replaced spare parts is deemed to be included in quoted rates 2. The cost of transportation (to and fro) for all kind of necessary equipment T&P shall be arranged/brought by contractor to complete the job at site and no extra cost shall be paid to the contractor in this effect. 1.01 capacity of 200 KVA(Tigrish Road)- 01 No 1.02 capacity of 250 KVA (Tigrish Road)- 01 No 1.03 capacity of 250 KVA (Behind Butchury Map Accn ) - 02 Nos 2.0 Supply and fixing in replacement of Megnetic pickup Sensor suitable for 250 KVA CUMMINS . DG set connecting with panel circuit, starting and testing on load all as specified and directed. - 02 Nos 3.0 Supply and fixing in replacement of Automatic Voltage regulator sutable for 200 KVA -250 KAV DG connecting with Panel circuit,starting and testing on load with all the parameters for safety protection and running suitable for the existing DG set of Make: Cummins / CG. - 02 Nos 4.0 Supply and fixing in replacement of Battery 12 V 150 Ah suitable for the existing DG set of Make: Exide / Amron. - 02 Nos 5.0 Supply and fixing in replacement of Battery 12 V 100 Ah suitable for the existing DG set of Make: Exide / Amron. -02 Nos 6.0 Supply and fixing in replacement of Lubricant oil pump Assembly sutable for 200 KVA -250 KAV DG with all connecting parts suitable for the existing DG set Make: Cummins / CG. - 01 Nos
Tushar engineers (BID ID -3501078)
Nakul Enterprises (BID ID -3501086)
Ashok Enterprises (BID ID -3503021)
Perfect Office Solutions (BID ID -3503411)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
finance_833781.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
Fwdltr1.pdf
Tender Documents • 0.19 MB
TermaAndCondition1.pdf
Additional Documents • 0.35 MB
BOQ_833781.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .