| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.8 LAccepted-AOC 0001 000 KACHARI ROAD RAMAIPATTI MIRZAPUR UTTAR PRADESH 231001 | MIRZAPUR | UTTAR PRADESH | 231001 | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹27.6 L+₹79,903 (2.98%)Rejected-AOC 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L2 | Rejected-AOC Not L1 bidder | |
| 3 | L3₹29.0 L+₹2.2 L (8.02%)Rejected-AOC | L3 | Rejected-AOC Not L1 bidder | |
| 4 | L4₹33.7 L+₹6.8 L (25.5%)Rejected-AOC GROUND FLOOR F 11 PHASE II MAYAPURI WEST DELHI DELHI 110064 | DELHI | WEST DELHI | DELHI | 110064 | L4 | Rejected-AOC Not L1 bidder | |
| 5 | L5₹34.7 L+₹7.9 L (29.5%)Rejected-AOC N A | NA | NA | 121004 | L5 | Rejected-AOC Not L1 bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
4 Jul 2024, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT 10.
GE U WATER SUPPLY DELHI CANTT 10.
REPAIR MAINTENANCE OF CENTRIFUGAL MONOBLOCK AND SUBMERSIBLE PUMP SETS AND DEVELOPMENT OF BOREWELLS INCLUDING CONNECTED ITEMS OF WATER SUPPLY INSTALLATIONS OF CHITRAL LINE OLD CHITRAL LINE BASANTAR LINE BUTCHERY OLD BASE HOSPITAL AFMSD AFTC NPG LINE H
2024_MES_658133_1
GE/WS/Token-03 OF 2024-25
Open Tender
Civil Works
Item Rate
330 days
GE U WATER SUPPLY DELHI CANTT 10.
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10.
₹90,000
Yes
3 Sept 2024
6 Jun 2024
6 Jul 2024
6 Jun 2024
4 Jul 2024
20 Jun 2024
Amount
Disconnecting electric connections from LT control panel and starter of submersible pump set of size 2 to 15 HP and removing the pipe line connections from discharge side and taking down/out submersible pump set along with column pipe from bore well with the help of chain pully block including transportation to workshop for repairs and back and lowering of same pump in bore well after repairs after replacement of rusted nuts, bolts, washers, rubber gasket etc including testing & commissioning complete all as specified and directed (Note : Serviceability of pumpset after repair shall be got tested by EIC before re-installation and lowering. Each pump maintenance/functionality/serviceability will be covered for one year after satisfactory repair and if pump motor winding brunt out in the contract period or within defect liability period of one year, the same will carried out by contractor Free of cost at his own arrangement. A BOO will be ordered for checking of serviceability & functionality of pump after repair from work shop and the same will be kept on record dully signed & concurred by GE. These aspect will be considered during quoting rates per unit (Each Job)
Disconnecting electrical connections from panel board including disconnecting the cable leads from the motor terminal box and taking down/out electric motor of any capacity and makes from base plate of pump set after opening the nuts, bolts etc and Dismantling of the induction/Submersible motor and seperate the stator and rotor and removing the Unserviceable DE & NDE side bearing, burnt winding wire from stator and rewinding the same as per existing supper enamelled copper wire with gauge 'F' class insulation used including varnishing and heating for drying of winding, transporting the motor to workshop for repair and back, re-installed after repair including testing complete all as specified and directed (Note : (i) Bidder will quote all in all rate according to weight of copper rewinding retrieved after dismentling and mode of measurement of the item is in "KG" only for all the repair/overhandling. Please quote rate accordingly, no any extra cost will be paid by Govt. (ii) A BOO conveyed for working out old unserviceable copper winding quantity details of each pump and the same replaced with new super enamel copper wire of suitable gauze as per old pumps make and submit serviceability / functionality of pumps.
(iii) Transportation/freight charges for shifting of pump to workshop and recieved back in the laying/installation place as directed by Engineer-in-Charge shall be deemed included in quoted rate. (iv) Old unserviceable brunt copper winding wire shall be contractor's property and accodingly unit rate by contractor shall be treated as included od unserviceable copper winding recieved by him during repair/over hauling.
Disconnecting electric connection and De-coupling the Centrifugal pump and removing from foundation for repair after opening /cutting the rusted nuts, bolts etc and dismantling complete pump and repairing the same with replacing the following unserviceable spare parts i.e. CI Casing wear ring, interstage ring, stuffing box bush, lentern ring, eye bolt with nut, shaft sleeve, impeller key, coupling key, water liquid reflector, bearing cartridge, bearing plate, shaft bush, MS stud with nut, mechanical seal, gasket packing including grinding work of lathe machine if any and re-assembling the same including the transporting the pump from side to workshop for repair and back, re-installed at existing position after repair and providing new MS nuts, bolts, packing flange etc including testing complete all as specified and directed of following capacity:-
12.5 to 15 HP Capacity centrifugal pump
20 HP Capacity Centrifugal pump
30 HP Capacity Centrifugal pump
40/50 HP Capacity Centrifugal pump
(Note for item no 3.01 to 3.04:- (i) Proper inventory for repair and over hauling parts replaced during the repair in work shop shall be prepared and kept in record dully verified and signed by EIC. (ii) Old unserviceable parts repaired & replaced shall be taken on charge under demolition/salvage register with page number in demolition statement.)
Disconnecting the electric connection of monoblock pump of following capacity and removing the same from foundationfor repair after opening /cutting the rusted nuts, bolts etc and dismantling complete pump and repairing the same with replacing the following unserviceable spare parts i.e CI Impeller, GM shaft sleeve, Mechanical seal, water seal, water liquid reflector, MS stud with nut, gasket packing including grinding work of lathe machine and re-assembling the same including the transporting the pump from side to workshop for repair and back, re-installed at existing position after repair and providing new MS nuts, bolts,packing flange etc including testing complete all as specified and directed. (Note:- (i) Proper inventory for repair and over hauling parts replaced during the repair in work shop shall be prepared and kept in record dully verified and signed by EIC. (ii) Old unserviceable parts repaired & replaced shall be taken on charge under demolition/salvage register with page number in demolition statement.)
Dismantling complete submersible pump and repairing the same with replacing the following unserviceable spare parts i.e GM bush, rotor sleeve, water seal,cable seal, thrust bearing, sealing ring, upper & lower housing flange upper & lower with stud and nut, wire mesh, drain plug, SS distance sleeve, impeller key, inter ring GM neck ring, Guide bush, GM impeller/EPV Impeller, CI section chamber,SS coupling, CI stage bowl, T bolt with nut including grinding work of lathe machine and re-assembling the same testing, complete all as specified and directed of following capacity:- (Note:- (i) Proper inventory for repair and over hauling parts replaced during the repair in work shop shall be prepared and kept in record dully verified and signed by EIC. (ii) Old unserviceable parts repaired & replaced shall be taken on charge under demolition/salvage register with page number in demolition statement.
5 to 7.5 HP Submercible pump
Submersible pump of capacity 10 to 12.5 HP
Disconnecting the all electric connection and lifting the raw sewage pump set from sludge well/equilisatin tank and dismantling complete raw sewage submersible pump of capacity 5 to 7.5 HP and repairing the same with replacing the following unserviceable spare parts i.e GM bush, rotar sleeve, water seal, thrust bearing, sealing ring, upper & lower housing flange upper & lower with stud and nut, wire mesh, drain plug, SS distance sleeve, impeller key, inter ring GM neck ring, Guide bush, GM impeller, CI section chamber,SS coupling, EPV impeller, CI stage bowl, T bolt with nut including grinding work of lathe machine and re-assembling the same testing complete all as specified and directed. (Note:- (i) Proper inventory for repair and over hauling parts replaced during the repair in work shop shall be prepared and kept in record dully verified and signed by EIC. (ii) Old unserviceable parts repaired & replaced shall be taken on charge under demolition/salvage register with page number in demolition statement.)
Supply and Fixing in replacement of Ball Bearing 6306 as per existing complete all as specified and directed.
Supply and Fixing in replacement of Ball Bearing 6307 as per existing complete all as specified and directed.
Supply and Fixing in replacement of Ball Bearing 6308 as per existing complete all as specified and directed.
Supply and fixing spare tyre for coupling type TC/P/011 after taking down/out as existing at site complete all as specified and directed
Supply and fixing spare tyre for coupling type TC/P/013 after taking down/out as existing at site complete all as specified and directed
Supply and fixing spare tyre for coupling type TC/P/014 after taking down/out as existing at site complete all as specified and directed
Supply and fixing spare tyre for coupling type TC/P/015 after taking down/out as existing at site complete all as specified and directed.
Supply and fixing spare tyre for coupling type TC/P/019 after taking down/out as existing at site complete all as specified and directed. (Note for ser item No 10 to 14:- Old unserviceable material spare tyre shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
M&L for applying painting Two coat of synthetic enamel paint as per existing pattern or scheme, on centrifugal pump & motor of any capacity rating 5-50 HP upto NRV or sluice valve,and MS Base channel including preparation of surfaces by scratching and removing the rust complete all as specified and directed.
Supply and Fixing in replacement MS base channel of size as exists including fabrication from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finshing coat of syenthetic enamel paint paint complete all as specified and directed.
Supplying , laying , jointing, welding and testing MS Pipe (Heavy class 'C') IS : 1239/3589, of followiing sizes laid in trenches or in Horizontal/Vertical/inclined position or laying on floors for connections for suction, to header and connected to out going water main CI/DI/GI pipe line, for following size including taking out the old unserviceable pipes Note:- MS Flanges incl fabrication work will be measured and paid separately.
80mm dia
100 mm dia
150 mm dia
Supply & Fixing in replacement MS Flange of following sizes, 16 mm thick, duly welded on ends of MS pipe including necessary cutting to existing MS pipe or in new MS pipe with flange joint including nuts, bolts, washers and rubber gaskets complete all as specified and as directed:- (Note:- Old unserviceable MS Flange shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
M&L for PCC (1:4:8) type D-2 (with 40 mm graded aggregate) as in coping, grouting, MS nut for motor base , finished even and smooth without using extra cement as on brick work/flooring complete including demolition of PCC complete all as specified and directed.
Supply and Fixing in replacement of Anti Vibration Pad with nuts, bolts and washers complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft/ loose soil complete all as specified ans directed.
Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all complete all as specified and directed.
Removing of excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all complete all as specified and directed.
Supplying and laying well burnt bricks sub class 'B' bricks for protection of cable complete all as specified and directed
Supply, fillings & spreading of fine 'Yamuna River' sand in trenches by providing 15cm below cable punned to 10cm after hand roller and 8cm above cable for cable protection complete all as specified ans as directed. NOTE: Punned down thickness of sand shall only be taken for measurement & payment.
Supply and fixing, testing & commissioning in replacement heat shrinkable jointkit suitable for XLPE cable insulated screened PVC bedded armoured electric power cable heave duty 1100 volts grade, with straded aluminium conductor, cross sectional area 16 Sqmm, 4 core after taking down/out faulty portion as exists compete all as specified and directed.
Supply and fixing, testing & commissioning in replacement heat shrinkable jointkit suitable for XLPE cable insulated screened PVC bedded armoured electric power cable heave duty 1100 volts grade, with straded aluminium conductor, cross sectional area 25 Sqmm, 3.5 core after taking down/out faulty portion as exists compete all as specified and directed.
Supply and fixing, testing & commissioning in replacement heat shrinkable jointkit suitable for XLPE cable insulated screened PVC bedded armoured electric power cable heave duty 1100 volts grade, with straded aluminium conductor, cross sectional area 35 Sqmm, 3.5 core after taking down/out faulty portion as exists compete all as specified and directed. (Note for ser item No 26 to 27:- Old unserviceable Joint material shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
Openning of gland packing coupling and removing the unserviceable gland rope from centrifugal/Monoblock pump set of capacity 15 to 50 HP and fixing the new gland rope all as per existing size gland rope complete all as specified and directed.
Openning of gland packing coupling and removing the unserviceable gland rope from centrifugal/Monoblock pump set of capacity 100 to 300 HP and fixing the new gland rope all as per existing size gland rope complete all as specified and directed. (Note:- Old U/s gland plate obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Excavation in trenches by cutting of road crossing, PCC hard standing for taking out/laying of cables including filling of M&L for PCC (1:2:4) type B-1 (with 20 mm graded aggregate) as in coping, grouting, finished even and smooth without using extra cement as on brick work/flooring complete making good the existing surface complete all as specified and directed.
M & L for heat shrinkable LT 1100V straight through joint suitabel for aluminium conductor cable of size 25 to 50 sqmm complte all specified and diretced.
Supply & fixing in replacement of switch piano, flush type single pole 1 way, 5 Amps complete all as specified and directed.
Supply & fixing in replacement of switch piano, flush type single pole 1 way, 15 Amps complete all as specified and directed.
Supply & fixing in replacement of socket outlet 6 Amp, 2 in 1,3 pin 5 Amps complete all as specified and directed.
Supply & fixing in replacement of socket outlet 15 Amp, 2 in 1,3 pin 5 and 15 Amps complete all as specified and directed.
Supply & fixing in replacement of Fan regulator step type, 120 watts complete all as specified and directed.
Supply and fixing in replacement of MCB SP 16 to 32 Amps ' C 'Curve , 240 volts AC supply, capacity not less than 10 KA connection complete all as specified and as directed.
Supply and fixing only LED tube fittings 18 Watt luminious all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver connection complete all as specified and directed.
Supply and fixing in replacement ceilling fan 1200 mm sweep Single pole 230V , 50Hz 'Five Star' complete with five step electronic fan regulator and down rod connection complete all as specified and directed.
S & F in replacement of 25 Watt LED post top New generation, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source connection complete all as specified and directed.
S&F of Analog time switch type QT (daily) model FM/1 QUARTZ, voltage 240 VAC,50 Hz, Contact rating 16 A/250 VAC complete all as specified and directed. (Note for ser item No 32 to 42:- Old unserviceable material shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
Supply only LED bulb of 9 watt complete all as specified and directed.
S&F in replacement rotational moulded polythylene water storage tanks of capacity 500 ltr triple layer cylindrical vertical with closed top hoisted and fixed in position for priming of centrifugal pump set all as specified in SSR part I complete all as specified and directed.
S&F in replacement rotational moulded polythylene water storage tanks of capacity 1000 ltr triple layer cylindrical vertical with closed top hoisted and fixed in position for priming of centrifugal pump set all as specified in SSR part I complete all as specified and directed. (Note for ser item No 44 to 45:- Old unserviceable material shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
Supply & Laying in replacement of 20 mm bore GI pipe 'medium' grade ISI mark including all fittings in old/new positions in trenches/wall/floor complet and making good the distributed surfaces as per existing complete all as specified and directed . (Note :- Old unserviceable GI Pipe shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
Supply & fixing in replacement of 20 mm Gun metal gate valve with iron wheel head screwed both ends for iron pipe as per IS-778 compete, ISI marked complete all as specified and directed. (Note :- Old unserviceable gun metal gate valve shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
Supplying and fixing MS column pipe, heavy grade, class 'C', 50 mm bore , heavy duty, flange welded on both ends of size 3 mtr length complete all as specified and directed. (Note: Rate quoted for taking up/down is deemed to be included in item no. 1)
Supplying and fixing MS column pipe, heavy grade, class 'C', 80 mm bore , heavy duty, flange welded on both ends of size 3 mtr length complete all as specified and directed. (Note (i): Rate quoted for taking up/down is deemed to be included in item no. 1) (Note (ii) for ser item No 48 to 49:- Old unserviceable material shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
Supply & fixing in replacement submersible copper cable of size 4 Sq mm 3 core, 1100 Volts complete all as specified and as directed by engr-in-charge. (Note:- Old unserviceable material shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
M&L for re-development of bore well of any capacity and size at the pressure 22 kg/sqcm to 25 kg/sqcm by DTH machine of capacity 1200 cfm includiing air pipe and connected items to improve the yield of tube well by DTH machine including transportation of machine complete all as specified and directed
M&L for Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 1100 volts LT cables of different sizes from both ends , removal of fault , Reconnection and testing of cables after removal of fault complete all as specified and directed by Engr-in-charge. NOTE: (a) 1100 volt cables and joints shall be measured and paid for seperately under respective items of schedule (b) Retrieved old serviceable cable cover/ bricks will be laid in trenches for cable protection. If extra PCC cover / bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Exacavation and earth work will be measured and paid for separately under respective items of schedule.
Materil and labour for pump shaft stainless steel suitable for 15 HP centrifugal pump set including turning, grinding and balancing work complete all as specified and diected.
Materil and labour for pump shaft stainless steel suitable for 40 HP centrifugal pump set including turning, grinding and balancing work complete all as specified and diected.
Materil and labour for pump shaft stainless steel suitable for 50 HP centrifugal pump set including turning, grinding and balancing work complete all as specified and diected.
Materil and labour for CI impeller suitable for 15 to 20 HP centrifugal pump set including turning, grinding and balancing work complete all as specified and diected.
Materil and labour for CI impeller suitable for 30 HP centrifugal pump set including turning, grinding and balancing work complete all as specified and diected.
Materil and labour for CI impeller suitable for 40 HP centrifugal pump set including turning, grinding and balancing work complete all as specified and diected.
Taking up suction pipe of size 80/100/150 mm dia after opening of nuts and bolts and open the bottom plate of Swing type CI foot valave and replace the unserviceable leather Gasket of swing disc as per existing size but the minimum thickness is not less than 6 mm complete all as specified and diected.
Surface dressing of uneven surfaces of natural ground, rough excavated surfaces not exceeding 15 cm deep and filled area where ordered shall be trimmed to an even surface horizontal or stopping, by removing vegetation and by scrapping high patches and filling low patches with the scrapping soil to given an even and neat look to the site complete all as specified and directed.
Supply & Fixing in replacement PVC insulated multistranded copper conductor wire of 16 Sqmm size, single core, 1100 volts complete all as specified and as directed.
Supply & Fixing in replacement PVC insulated multistranded copper conductor wire of 25 Sqmm size, single core, 1100 volts complete all as specified and as directed. (Note for ser item No 61 & 62:- Old unserviceable material shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
Supply & fixing in replacement of MCCB thermal relay range 320- 400 Amps, 4 pole 415V of breaking capacity 50 KA and and connecting to bus bars and cable end termination with suitable lugs complete all as specified and directed.
Supply & fixing in replacement MCCB thermal relay range 200- 250 Amps, 4 pole 415V of breaking capacity 36 KA and and connecting to bus bars and cable end termination with suitable lugs complete all as specified and directed
Supply & fixing in replacement MCCB thermal relay range MCCB 160-200 Amps, 4 pole, 415 V, breaking capacity 36 KA complete all as specified and directed.
Supply & fixing in replacement MCCB thermal relay range 3 pole MCCB 100-125 Amps,415V, breaking capacity 18 KA complete all as specified and directed.
Supply & fixing in replacement MCCB thermal relay range 3 pole MCCB 63-80 Amps,415 V, breaking capacity 18 KA complete all as specified and directed. (Note for ser item No 63 to 67:- Old unserviceable material shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
Fixing only fully automatic star delta motor starter MN or ML suitable for 17.5 HP of motor rating AC 3 duty 415V 50 Hz 3 phase, ML-1.5/MN 16 FASD relay range 9-15 Amps including taking down old starter complete all as specified and directed.
Supply & Fixing fully automatic star delta motor starter MN or ML suitable for 30 HP of motor rating AC 3 duty 415V 50 Hz 3 phase, ML-2/MN 25 FASD relay range 14-23 Amps including taking down old starter complete all as specified and directed.
Supply & Fixing fully automatic star delta motor starter suitable for 40 HP of motor rating AC 3 duty 415V 50 Hz 3 phase, ML-3 / MN 32 FASD relay range 20-33 Amps including taking down old starter complete all as specified and directed.
Supply & Fixing fully automatic star delta motor starter type suitable for 50 HP of motor rating AC 3 duty 415V 50 Hz 3 phase, ML-4 / MN 45 FASD relay range 30-50 Amps including taking down old starter complete all as specified and directed.
Supply and fixing DOL motor starter suitable for 10 HP of motor rating AC 3 duty 415V 50 Hz 3 phase, ML / MN relay range 9-15 Amps including taking down old starter complete all as specified and as directed by Engr in charge. (Note for ser item No 68 to 72:- Old unserviceable material shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
Supply & Fixing in replacement 3 pole power contactor type ML-1.5 or MNX type, 415 Volts, 50 HZ range 25 Amps complete all as specified and as directed.
Supply & Fixing in replacement 3 pole power contactor type ML-2 or MNX type, 32 Amps, 415 Volts, 50 HZ complete all as specified and as directed.
Supply & Fixing in replacement 3 pole power contactor type ML-3 or MNX type, 40 Amps, 415 Volts, 50 HZ complete all as specified and as directed.
Supply & Fixing in replacement 3 pole power contactor type ML-4, 70 Amps, 415 Volts, 50 HZ complete all as specified and as directed
Supply & Fixing in replacement of over load replay type ML 1.5 or MNX type , relay range 14-23 Amp complete all as specified and as directed.
Supply & Fixing in replacement of over load relay type ML 2 or MNX type , relay range 20-33 Amps complete all as specified and as directed.
Supply & Fixng in replacement of over load relay type ML 3 or MNX type , relay range 24-40 Amps complete all as specified and as directed. (Note for ser item No 73 to 79:- Old unserviceable material shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
Supply and installation of flanged ends Water Meter woltman type, including testing and making good connection with flanged ends, with gasket rubber sheet and nut & bolts etc ISI Marked fixing in horizontal/incline/vertical position, including taking out unserviceable of following sizes complete all as specified and as directed at site by the Engineer-in-Charge. (Note :- Old unserviceable material shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
100 mm bore
150 mm bore
Supply and Fixing in replacement of CI Foot valve of following size , Flanged ends, Swing type opration with rubber sheet as per IS-4038 including taking out unserviceable of following sizes complete all as specified and directed by Engineer-in-Charge. Note (i) :- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this items. (ii) Old unserviceable material shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
80 mm bore
100 mm bore
150 mm bore
Supply and installation of flanged ends strainer/dirt box, PN-10 with stainless steel mesh suitable for water meter for potable water supplies on up stream of water meter to avoid foreign material entering into meter including taking out unserviceable of following sizes complete all as specified and as directed at site by the Engineer-in-Charge. (Note :- Old unserviceable material shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
100 mm bore
150 mm bore
Material and labour including jointing and testing of cast iron sluice valves class PN-1.0, conforming to IS:14846 flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and rubber gaskets including taking out unserviceable sluice valve and removal from site for the follwing sizes complete all as specified and directed. (Note:- Old unserviceable material shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
80 mm bore
100 mm bore
150 mm bore
Supply and fixing jointing and testing of cast iron Non return valve without by pass arrangment swing type confirming to IS 5312 flanged ends pressure rating PN 1.0 complete including taking out unserviceable NRV all as specified and as directed by Engineer-in-Charge. Note (i) - Flanged joints complete with rubber jointing materail shall deemed to be included in the unit rate of this item. (ii) Old unserviceable material shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
80 mm bore
100 mm bore
150 mm bore
M P TYAGI ENGINEERS AND CONTRACTORS
B.R. Enterprises
AMIT ENTERPRISES
M/s Sree Baba Traders
Yadav Enterprises
SALUJA CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .