Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.8 LAccepted-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L1 | Accepted-AOC Awarded being lowest bidder | |
| 2 | L2₹17.3 L+₹2.3 L (15.1%)Rejected-AOC 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹18.7 L+₹3.6 L (23.9%)Rejected-AOC | L3 | Rejected-AOC Other than lowest bidder | |
| 4 | L4₹20.6 L+₹5.5 L (36.6%)Rejected-AOC | L4 | Rejected-AOC Other than lowest bidder | |
| 5 | L5₹22.4 L+₹7.3 L (48.7%)Rejected-AOC A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | L5 | Rejected-AOC Other than lowest bidder |
Tender Value
₹38.5 L
EMD Value
₹77,000
Closing Date
26 May 2021, 6:00 pmClosed
GE (P) AF Gurgaon
GE (P) AF Gurgaon NEAR ATUL KATARIA CHOWK GURGAON 122005
GE (P) AF/GUR-15/2021-22 REPAIR, MAINTENANCE OF AIR TERMINATION, EARTHING AND ALLIED WORKS FOR LIGHTENING PROTECTION SYSTEM AND REPLACEMENT OF UNSERVICEABLE POINT WIRING, FLAME PROOF FITTINGS WITH ENERGY SAVING LED FLAME PROOF LIGHT FITTINGS AND FIXT
2021_MES_439000_1
GE (P) AF/GUR-15/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
272 days
GE (P) AF Gurgaon
AS SPECIFIED IN NIT
10 documents required · 10 mandatory
₹500
GE (P) AF Gurgaon
₹77,000
Yes
2 Jun 2021
28 Apr 2021
28 May 2021
28 Apr 2021
26 May 2021
12 May 2021
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets etc. to be measured separately), removing materials to store for keeping in safe custody for re-use at site/Sch of credit and making good disturbed surface of walls, floors, etc., complete all as specified and as directed by Engineer-in-Charge.
M&L for Point wiring complete with HRFR PVC insulated unsheathed , 1100 V grade conforming to IS 694 , 1.5 Sqmm (Norminal area) multistranded , copper conductor cable drawn through in non metallic rigid PVC conduit medium grade , minimum 20 mm dia conceled in wall , ISI Marked, and connect accessories, mounting on suface of walls / ceilings /roofs etc with shunken box anodised concealed in suface of wall , 3 mm thick laminated plastic sheet cover for mounting of switches, sockets outlets, regulators etc, fixed by suitable size of 04 Nos cadmium screwes including provision of HRFR PVC insulated unsheathed 1.5 Sqmm muiltistranded green colour copper conductor cable as earth connectivity and connecting to common earth dolly complete all as specified and as directed by Engineer-in-Charge, (The works includes cutting of chasis and making good disturbed surfaces and rate deemed to included in quated rate):-
One light point controlled by one way one switch SP 5 Amps , 240 V.
One ceiling fan / Exhaust point controlled by one way one switch SP 5 Amps, 240 V.
One switch socket outlet 3 Pin, 5 Amps, SP on independent board.
One switch socket outlet 3 Pin, 5 Amps, SP on same board.
All as per the item No 2 here in before but with 2.5 Sqmm cable for 3 pin 15 Amps socket complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement switch piano flush type single pole one way , 5 Amps , 240V grade ISI marked , complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement switch piano flush type single pole one way , 15 Amps , 240V grade ISI marked, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement socket outlet 2 in 1 ,3 pin 5 Amps flush type ISI marked, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement socket outlet 2 in 1 ,3 pin 5 and15 Amps flush type ISI marked, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement step type elctronic fan regulator flush type, single phase 220 V , one module type, complete all as specified and as directed by Engineer-in-Charge.
Taking out old U/S submain wiring of any size and removing materials to store or as sch of credit including making good of existing surfaces complete all as specified and as directed.
M&L in replacement of sub main wiring with multistranded FR copper conductor cable PVC sheathed in and including concealed suitable size PVC conduit medium grade with fittings and two runs of 6 Sqmm and one run of 6 Sqmm FR copper conductor as earth wire and connected to earth dolly all as specified and as directed by Engr-in-Charge. ( The item includes cutting Chasis and making good the disturbed surfaces).
M&L for Re-fixing of tube light fitting of any capacity dismantled under Item No 1 above, to the same locations after repairing if required and making all necessary connections, complete all as specified and directed by Engr-in-charge.
S & F in replacement LED Tube light surface and wall mounted LED batten of 20W, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with industrial grade heavy duty driver having THD<10%. Makes :Havells Cat Part No-NDURALINEARNEOBS20WLED865SPCWH or equivalent out of makes specified in list of makes.
S&F in replacement sheet metal enclosure for MCB's (D.B) 4 way (SPN) 200 Amps rated bus bar complete all as specified and as directed. Cat No- DHDMSHODDW04 Make Havells or equivalent out of makes specified in list of makes.
S&F in replacement sheet metal enclosure for MCB's (D.B) 6 way (SPN) 200 Amps rated bus bar complete all as specified and as directed. Cat No- DHDMSHODDW06 Make Havells or equivalent out of makes specified in list of makes.
S&F in replacement sheet metal enclosure for MCB's (D.B) 8 way (SPN) 200 Amps rated bus bar complete all as specified and as directed. Cat No- DHDMSHODDW08 Make Havells or equivalent out of makes specified in list of makes.
S&F in replacement sheet metal enclosure for MCB's (D.B) 12 way (SPN) 200 Amps rated bus bar complete all as specified and as directed. Cat No- DHDMSHODDW12 Make Havells or equivalent out of makes specified in list of makes.
S&F in replacement of MCB 240 volts SPN 06- 32 amp 10KA breaking, capacity, ISI marked, Cat No- DHMGCSNF006-032 of Havells or equivalent in makes specified in list of makes complete all as specified and as directed.
M&L in replacement of MCB 240 volts SP 6- 32 amp 10KA breaking, capacity, ISI marked, Cat No- DHMGBSPF006-032 of Havells or equivalent in makes specified in list of makes complete all as specified and as directed.
M&L of replacement of MCB 415volts TPN 63 amp 10KA breaking, capacity, ISI marked,of make Havells or equivalent in makes specified in list of makes complete all as specified and as directed.
Taking down carefully AC single phase 220/230volt ceiling fan 1200/1400mm sweep single phase for rewinding and replacement of unserviceable parts i.e Capacitor, PVC connector, MS galvanised check nut, ball bearing, rubber pads, PVC strip clamps including servicing such as removing dust & dirt brushing, rubbing with cotton waste, , washing with detergent powder to fan blades, greasing bearing with ball bearing grease & washer packing, checking of bolts/nuts, washer check nuts split pin, rubber packing and rubber seal etc including testing after assembling, hanging/fixing on hook and connecting to electric system complete all as specified and as directed by Engr-in-Charge. Note : 1. Rates of winding and replacement of any unserviceable parts mentioned above required to make the fan in serviceable condition except Note 2 below are included in the quoted rate. 2. Rates of bearing, capacitor, blades & painting shall be measured and paid seperately in the concered item of schedule.
All as per srl item No 19 hreinbefore but for wall mounting fan plastic type of size 250/300mm sweep complete all as specified and as directed by Engineer-in-Charge.
Taking down and serviceing of ceiling fan 1200/1400 mm sweep at site and removing of old grease from bearing of ceiling fan and re-filling new grease including replacement of worn out nut bolt, rubber real, bush gun metal, ball bearing, capacitor split pin and re-assembling the fan including testing after assembling, hanging/fixing on fan hook and connecting to electric system complete all as specified and as directed by Engr-in-Charge. NOTE:- Supply of bearing, capacitor, blades & painting shall be measured and paid seperately in the concerned item of schedule.
All as per srl item No 21 hereinbefore but for exhaust fan of any size complete.
S&F in replacement Electric cable PVC insulated with copper conductor (flexible cable) size 23/0.0076 twin core for connecting fan to electric system, complete all as specified and as directed by Engineer-in-Charge.
M&L for Spray painting to AC ceiling fan 1200/1400mm sweep any make complete to motor assy, down rods, blades with ISI marked white/brown synthetic enamel paint as approved by Engr-in-Charge after preparation of surface including filling cavities with filler, writing of MES No complete complete all as specified and as directed by Engr-in-charge.
Taking down metallic type Exhaust fan of any size in situ for spray painting with ISI marked OG/brown/black synthetic enamel paint as directed by Engr-in-charge after preparation of surface and refixing the same in existing location after painting complete all as specified and as directed by Engr-in-charge.
S&F in replacement Ball bearing suitable size of ceiling fan any type and size, complete all as specified and as directed by Engineer-in-Charge. Make : SKF/PNB/TATA/NBC.
S&F in relacement only Ball bearing suitable size of Exhaust fan any type and size, complete all as specified and as directed by Engineer-in-Charge. Make : SKF/PNB/TATA/NBC.
S&F in replacement fan blade (set of 03) suitable for 1200 mm sweep all as specified and as directed by Engr-in-Charge.
S&F in replacement exhaust fans blades suitable for 300/450 mm sweep any make and suitable colour including taking down all as specified.
S&F in replacement louvers only for exhaust fan of size 300mm sweep made out of MS sheet 22 gauge complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement Canopies for AC ceiling fan of size 1200/1400mm sweep for any make of fan, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement down rods for ceiling fan 1200/1400mm sweep of size 2.5' long duly painted with white synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge.
M&L for Remetaling to worn out shaft of fan motor turning complete to obtain the standard dia of shaft for fixing standard size bearing/bushes to ceiling fan of 1200/1400mm sweep of any make complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement Hanging clamp suitable for ceiling fan of size 1200/1400mm of any make complete with nuts, bolts, rubber reel and locking pin complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement capacitor 2.5 mfd + 5%, 220/230 volts AC, 50 c/s, complete all as specified and as directed by Engineer-in-Charge. Make: Usha/Epcos/Tibcon.
S&F in replacement capacitor 3.15 mfd + 5%, 220/230 volts AC, 50 c/s, complete all as specified and as directed by Engineer-in-Charge. Make: Usha/Epcos/Tibcon.
Dismantling and taking up old existing unserviceable GI earth plate with GI strip earthing and connected items upto test point complete all as specified and as directed by Engr in charge.
M&L in replacement for plate earthing with copper plate 60 cm x 60 cm x 3.15 mm thick electrode and 25x 3mm copper strip as earthing lead buried directly in ground vertically (in earth pit not less than 4.0 m deep below normal ground level) with the top edge of the earth plate at a depth not less than 3.25 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including copper strip 25x 3 mm (with Brass nuts, bolts & check nuts with breezing) and connect to earth plate at one end and to test point other end providing watering pipe 50mm bore light grade from top end of plate upto 30cm above GL with top end plug/ cap including (30 x30 x 30) cm PCC 1:2:4 flushing to GL. 40mm bore GI light grade protection pipe to strip complete with earth pit in PCC 1:2:4 type B-0 using 12.5 mm graded crushed stone aggregate and RCC cover) complete all specified and shown in electrical plate No 3 of SSR Pt-I. The 50mm dia watering pipe shall be drilled 03 Nos 5mm dia hole above PCC block nearest to ground level to enter rain water in the pit complete all as specified and directed by Engr-in-Charge. Note : No joint in copper strip shall be accepted between earth electrode to test point. The single length copper strip shall be provided to earth plate to test point.
M & L in replacement for test point terminal block made of gun metal or phosphorus bronze /brass size (75 x 75 x10) mm drilled and 3 nos brass screwed 8 mm dia ,10 mm long hex.head screw complete including GI fabricated test point box size 150mm x 100mm x 75mm height with front openable made out of not less than 0.6 mm thick PGI sheet including painting complete all as specified and as directed by engr- in charge.
M&L in replacement for earth continuity conductor or main earthing lead fixed to Floor/wall / roof/Air termination and connecting Machinery to test point with 25x3 mm Copper strip including taking down existing copper strip complete all as specified and directed.
S&F in replaement of porcelin viterous white/ brown/ green insulators of sizes 25mm x 25mm having provision of two holes for fixing on roof / wall under strip/ channel on top for running of down conductors to maintain gap between wall and down conductors etc complete all as specified and directed by Engr-in-Charge.
M&L for repair of earthing pit with brick work and PCC 1:3:6 including RCC pit cover of size 300x300mmx50mm thick with provision of opening handle complete including necessary watering, ramming and compact of soil near the earth pit all as specified and as directed by Engr-in-charge.
M&L in replacement for earth continuity conductor or main earthing lead fixed to Floor/wall / roof/Air termination and connecting Machinery to test point with 25x3 mm aluminium strip including taking down existing aluminium/GI strip complete all as specified and directed by Engr-in-Charge .Note :- (i) Laying / fixing of strip from air termination to test point shall be in one run i.e. there shall be no joint in between air termination. In case joint is required, it shall be jointed with nut & bolt joint with breezing full contact of strip. ii) Strip shall be fixed on insulator at the interval not more than 900mm in such a manner at any place it shall not touch to wall/ roof / any metalic body. (Cost of insulator shall be measured and paid seprately under respective items of Sch of works as supply only).
M&L in replacement for connecting GI pipe line of 20mm medium grade galvanised with all fittings (i.e union/joint/tees etc) required for connection from tank to stand post as specified and directed by engineer in charge of approved make.
M& L in replacement for fixing of GI Pipe 50mm dia light grade laid in trenchless and cover to the cable all as specified and directed by Engr-in -charge.
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth for foundation etc or for shafts wells, cesspits, mahnoles, pier holes ect not exc 10 Sqm on plan and not exc 1.5M in depth and getting only out in Hard/dense soil complete all as specified.
Returning, filling in trenches including spreadin, levelling watering and well ramming in layers not exceeding 25 cms thick in each layer of hard soil complete all as specified and directed.
Supply & fixing in replacement of gun metal Gate Valve of 20mm dia with all item required all as specified and directed.
S & F in repalacement service connection 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and over all PVC sheathed of size 6 Sqmm, 2 core complete all as specified and directed by Engr-in-Charge.
Supplying , laying , passing through pipe , connecting and testing UG cable XLPE insulated ,armoured heavy duty electric cable with aluminium conductor ,1100 volts grade of 16 Sqmm 4 corecomplete all as specified and as directed by Engr-in-charge. (Note:- Excavation & earthwork etc shall be measured and paid sepretaly).
Supplying , laying , passing through pipe , connecting and testing UG cable XLPE insulated ,armoured heavy duty electric cable with aluminium conductor ,1100 volts grade of 10 Sqmm 2 corecomplete all as specified and as directed by Engr-in-charge. (Note:- Excavation & earthwork etc shall be measured and paid sepretaly).
Supplying , laying , passing through pipe , connecting and testing UG cable XLPE insulated ,armoured heavy duty electric cable with aluminium conductor ,1100 volts grade of 25 Sqmm 4 corecomplete all as specified and as directed by Engr-in-charge. (Note:- Excavation & earthwork etc shall be measured and paid sepretaly).
Excavation in trenches in soft/loose soil , not.exc 1.5 mtr wide and not.exc 1.5 mtr deep and getting out in soft/loose soil for laying of cable/foundation of pole and stay etc in complete all as specified and directed by Engr-in-Charge.
Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above ground level from starting point complete all as specified and directed by Engr-in-Charge.
Returning filling including spreading, levelling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed by Engr-in-Charge.
M&L for sand cushioning in trenches for protection of LT under ground cable including watering and consolidation complete all as specified and directed by Engr-in-Charge.
Supply and laying well burnt sub class ‘B’ bricks, locally available in trenches for protection of underground cable complete all as specified and directed by Engr-in-Charge.
M&L in replacement for making stand post (1 m long) each made out of GI Pipe 50 mm dia medium grade for fixing on the roof top of the building, etc. complete all as specified and directed by Engr-in-Charge.
M&L for making PCC block of size 25 X 25 X 25 cm in PCC 1:2:4 Type B1 with 20 mm graded stone for arresting GI pipe post on the roof top of the building complete, etc. complete all as specified and directed by Engr-in-Charge.
S&F in replacement single pointed air termination aluminium rod 300 mm long 12 mm dia of superior quality of the rod for fixing on the rooftop of the building, etc. complete all as specified and directed.
M&L for preparation of old painted surface of electric steel pole by first scrabing and removing all rust,dirt, dust etc and then apply one coat of aluminium paint on complete steel surface including cross arm and writing of identification No , etc complete all as specified and directed.
Supply and fixing in replacement of new generation energy saving environemental friendly long life exclusive innovative die cast aluminium IP65 LED flood light with high power LEDs as light source of capacity 120 Watt complete all as specified and directed by Engineer-in-Charge. Make: Havells Cat Part No.JETAIRISFLS120WLED757APWBLTG or equivalant out of makes specified in list of makes.
Supply and fixing in replacement of new generation energy saving environemental friendly long life exclusive innovative die cast aluminium IP65 LED flood light with high power LEDs as light source of capacity 60 Watt complete all as specified and directed by Engineer-in-Charge. Make: Havells Cat Part JETAQUANTOPLUSFLP60WLED757SYMLENS or equivalant out of makes specified in list of makes.
S& F in replacement of MCCB 100Amp 4Pole,415V ,16KA complete all as specified and directed by Engineer-in-Charge. Make: Havells Cat Part No: IHDA3BBF0100 or equivalant out of makes specified in list of makes.
S& F in replacement of MCCB 160Amp 4Pole,415V ,16KA complete all as specified and directed by Engineer-in-Charge.Make:Havells/L&T/ABB or equivalant out of makes specified in list of makes.
S& F in replacement of MCCB 63Amp 4Pole,415V ,16KA complete all as specified and directed by Engineer-in-Charge.Make: Havells Cat Part No: IHDA3BBF0100 or equivalant out of makes specified in list of makes.
Labour and T&P for Shifting of transformer by Hydra and related required accessories within 54 ASP Domestic area, G Block and Technical area complete all as directed by Engineer-in-charge.
M & L for improvment of the earth resistance by using salt and charcoal and checking and measuring the earth resistance of earthing for lightening arrester and equipment earthing with earth resistance tester every months with compiling the following -: (a) Collecting the water from near by source and filling in earth pit before one day from checking the earth resistance.(80Ltr water and 05Kgs salt in each earthing) (b) Tightening of earth strip connection on test point and earth pit. (c) The earth resistance value of all earthing pit should be recorded in resister duly signed by JE E/M. (d) pouring salt and charcoal for improving the earth resistance
Note:- The amount of Rs 1,31,640/- against Schedule of Credit on Page No 116 shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance
Saini Enterprises
Phogat Builders
PARKASH ENTERPRISES
Ridhi engineers and builders
Haryana EngineerService
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .