| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 LAccepted-AOC | L1 | Accepted-AOC REASONABLE | |
| 2 | L2₹9.3 L+₹3,311 (0.36%)Rejected-Finance | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹9.3 L+₹4,655 (0.50%)Rejected-Finance E 140 2010 BKP VILL AMTALLA PO DUMARCHIR DIST PAKUR PIN 814111 JHARKHAND | PAKUR | PAKUR | JHARKHAND | 814111 | L3 | Rejected-Finance HIGH RATE | |
| 4 | L4₹9.4 L+₹16,158 (1.74%)Rejected-Finance HATIA ROAD DANGALPARA DISTT DUMKA JHARKHAND PIN 814101 | DUMKA | DUMKA | JHARKHAND | 814101 | L4 | Rejected-Finance HIGH RATE | |
| 5 | L5₹9.4 L+₹17,441 (1.88%)Rejected-Finance | L5 | Rejected-Finance HIGH RATE |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
29 Jan 2024, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri tapan das AE (CIVIL)
AGE I AF Singarsi
Repair maint of flame pfoof light fittings flame proof wiring flame proof external switch LA and other connected works of OTM Accn area at AF Station Singarsi Under AGE I AF Singarsi
2024_MES_636425_1
C/8637/E8
Open Tender
Civil Works
Item Rate
180 days
AGE I AF Singarsi
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
AGE I AF Singarsi
₹19,000
Yes
14 Feb 2024
8 Jan 2024
30 Jan 2024
8 Jan 2024
29 Jan 2024
22 Jan 2024
Amount
Supply and fixing in repair flame proof LED light fitting 1x 40 watt with wire guard and reflector as per IS-2206-3 (1989), complete all as specified and as directed. Make : Sudhir/FCG
Supply and fixing in repair flame proof LED light fitting 2x 40 watt with wire guard and reflector as per IS-2206-3 (1989), complete all as specified and as directed. Make : Sudhir/FCG
Supply and fixing in repair flame proof 16A 415V rotary switch ON/OFF as per IS-2206-3 (1989), complete all as specified and as directed. Make : Sudhir/FCG
Supply and fixing in repair flame proof Distribution Board 6 way per IS-2206-3 (1989) complete all as specified and as directed. Make : Sudhir/FCG
M&L for point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including heavy duty Metal Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. fixed on wall including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified.
M&L for Sub main wiring with 2 runs of 4 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty metal Conduit, 25 mm dia with all accessories fixed on Walls / Roofs / Floors / Ceiling etc. including One run of 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified. [Note: 3 runs of 4 Sq.mm & one run of 25mm dia PVC Conduit will be measured as one unit]
Supply and fixing in repair steel, flexible conduit of medium grade of diameter 15mm, complete all as per specified and as directed.
M& L for lightning arresters expulsion type complete with all fittings, 30 kilo amp discharge capacity, distribution class, complete all as specifies and as directed.
M&L for point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and PVC casing caping of size 20mm including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. fixed on wall including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified and as directed.
All as per item no 9.00 here in before but one 3/5 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5 sq. mm size.
All as per item no 9.00 here in before but one 3/5 pin socket outlet, 5 Amps, independent, with cables 1.5 sq. mm size.
All as per item no 9.00 here in before but one 3/5 pin socket outlet, 15 Amps, independent, with cables 4 sq. mm size.
S&F in repair for switch piano flush type 6 Amp single pole one way complete all as specified and as directed.
S&F in repair for socket flush type 6 Amp 5 Pin complete complete all as specified and as directed.
S&F in repair for switch socket combination 5 Pin 6 Amp universal complete all as specified and as directed.
S&F in repair for switch socket combination 5 Pin, 6/15 Amp universal complete all as specified and as directed.
S & F in repair ceiling rose, 3 phase/PVC/Polycarbonate, isolated body complete all as specified and as directed.
S&F in repair sheet metal enclosures for DB’s double door suitable for mounting of MCB’s/Isolators, 240 Volt, SPN, 4 way with built in bus bar complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour complete all as specified and as directed. (Make:Havells ,Hager,Schneider or Legrands).
S&F in repair sheet metal enclosures for DB’s double door suitable for mounting of MCB’s/Isolators, 240 Volt, SPN, 8 way with built in bus bar complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour complete all as specified and as directed. (Make:Havells ,Hager,Schineder or Legrands).
S&F in repair VTPN distribution board with provision of MCCB as incommer, double door suitable for mounting MCB's/Isolators, 240 Volt,4 way with built in160A rated bus bar and with out MCCB complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour complete all as specified and as directed. (Make: C&S/Hager/Siemens/Legrand
M&L for MCCB, 4P, 415V, overload adjustable 0.63 - 0.8-1 x in short circuit fixed 63 Amps breaking capacity 16KA complete all as specified and as directed. (Make:Hager ,Schnieder or Legrands).9380
M&L for for MCB, SP, 240V,40 Amps and ' B ' series breaking capacity 10 KA ISI marked complete, all as specified and as directed.
M&L for MCB, SP, 240V, 6 to 32 Amps and ' C ' series breaking capacity 10 KA ISI marked complete, all as specified and as directed.
M&L for MCB, SPN, 240 V, 40 to 63A Amps, and ‘C’ series breaking capacity 10 KA complete ISI marked , all as specified and as directed.
Supply and fix in repair ceiling fan regulator electronic Step type, solid state, 120W, 2 module, 240 volts, complete all as specified and as directed.
S&F in repair metal clad box enclosure with socket plugtop and MCB SP 20 Amp flush of 240v mounting enclosure with 2 pin earth plug socket complete all as directed (Make - Havells Hager/legrand)
S&F in repair for wall mounted LED 4 feet 20 Watt fittings with high diffuser , driver holder extruded aluminium heat sink provided for energy efficient heat dissipation &integrated electronic incl all accessories and lamp ,internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed by Engr-in-charge. (Make :Crompton , Bajaj/Philips/Havells)
S&F in repair for wall mounted LED 2 feet 10 Watt fittings with high diffuser , driver holder extruded aluminium heat sink provided for energy efficient heat dissipation &integrated electronic incl all accessories and lamp ,internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed by Engr-in-charge. (Make :Crompton , Bajaj/Philips/Havells)
S&F in repair for bulk head fitting 10 Wattt fittings with high diffuser , driver holder ,internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed by Engr-in-charge. (Make :Crompton , Bajaj/Philips/Havells)
M&L for earthing complete with galvanised steel earth plate electrode 600x600x 6mm thick burried in ground (earth pit not less than 2.25 m deep below ground level0with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip 25x4 mm as earthing lead by means of bolts, nuts, check nuts, and washers of GI or steel, GI strip protected by 40 mm bore medium grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade GI, wire mesh charcoal or coke common salt laid in altrnative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC(1:3:6) type C-1, 50 mm thick pre-cast RCC(1:2:4) type B-1 normally mix cover slab reinforced with in 8 mm dia TMT bar 10 cm C/C both ways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft/loose/hard soil and disposal of soil to a distance n.exc 50 m and necessry testing on completion all as shown in electrical plate No 3 MES schedule part-I complete all as specified and as directed.
DANATION CONSTRUCTIONS
M/S MBS TRADING CO
M/S KUMAR AVINASH
M/S Subhadip Enterprise
M/S New Builders Corporation
M/S SINGH ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .