Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.8 CrAdmitted-Finance | ₹12.8 Cr | L1 | Admitted-Finance |
| 2 | L2₹15.4 CrAdmitted-Finance DISTT BARMER | BARMER | ₹15.4 Cr | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not recommended as enlistment not valid and docuemnts as per in enlisted firm not submitted |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not recommended as enlistment not valid and adverse remark in WLR |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not recommended as adverse remarks in WLR of CESC |
| Sl No | Description | Qty | Unit | M/s Tansingh Chouhan L2 | M/s PRABHU DAN DETHA AND COMPANY L1 |
|---|---|---|---|---|---|
| .10NOTE: Schedule ‘A’ Part I to XII under Ser No. 1.00 to 12.00 are prepriced by MES. Bidders shall insert their lumpsum amount in the green coloured field under Col-6 only. | |||||
| 1.00 | Lump sum price worked out for BUILDINGS/ STRUCTURES as listed in Sch 'A' Part I. | 1 | Lumpsum | 11,60,00,000 ₹11.6 Cr | 9,28,06,000 ₹9.3 Cr |
| 2.00 | Lump sum price worked out for EXCAVATION, EARTH WORK AND SITE CLEARANCE as listed in Sch 'A' Part II | 1 | Lumpsum | 44,00,000 ₹44 L | 43,00,000 ₹43 L |
| 3.00 | Lump sum price worked out for INTERNAL WATER SUPPLY as listed in Sch 'A' Part III | 1 | Lumpsum | 5,00,000 ₹5 L | 3,50,000 ₹3.5 L |
| 4.00 | Lump sum price worked out for INTERNAL ELECTRIFICATION as listed in Sch 'A' Part IV | 1 | Lumpsum | 40,00,000 ₹40 L | 48,00,000 ₹48 L |
| 5.00 | Lump sum price worked out for ROAD/ PATH/ HARDSTANDING/ CULVERT as listed in Sch 'A' Part V | 1 | Lumpsum | 60,00,000 ₹60 L | 61,00,000 ₹61 L |
| 6.00 | Lump sum price worked out for SEWAGE DISPOSAL as listed in Sch 'A' Part VI | 1 | Lumpsum | 7,50,000 ₹7.5 L | 6,80,000 ₹6.8 L |
| 7.00 | Lump sum price worked out for AREA DRAINAGE as listed in Sch 'A' Part VII | 1 | Lumpsum | 8,50,000 ₹8.5 L | 7,00,000 ₹7 L |
| 8.00 | Lump sum price worked out for EXTERNAL WATER SUPPLY as listed in Sch 'A' Part VIII | 1 | Lumpsum | 1,70,000 ₹1.7 L | 1,20,000 ₹1.2 L |
| 9.00 | Lump sum price worked out for EXTERNAL ELECTRIFICATION as listed in Sch 'A' Part IX | 1 | Lumpsum | 17,00,000 ₹17 L | 20,00,000 ₹20 L |
Updated dates
Tender Value
₹12.3 Cr
EMD Value
₹9.4 L
Closing Date
1 Apr 2026, 6:00 pmClosed
CE (AF) GANDHINAGAR
Lekawada Patia, Chiloda, Gandhinagar-382042
PROVN OF DEFICIENT MARRIED ACCN AND ALLIED SERVICES AT AF STN JAISALMER
2026_MES_747151_1
81220
Open Tender
Civil Works
548 days
GE (AF) Jaisalmer
All as per NIT and Tender Document
7 documents required · 7 mandatory
₹3,000
GE (AF) Jaisalmer
₹9.4 L
Yes
20 Apr 2026
3 Jan 2026
3 Apr 2026
3 Jan 2026
1 Apr 2026
18 Mar 2026
6 Jan 2026 - 10 Jan 2026
NOTE: Schedule ‘A’ Part I to XII under Ser No. 1.00 to 12.00 are prepriced by MES. Bidders shall insert their lumpsum amount in the green coloured field under Col-6 only.
Lump sum price worked out for BUILDINGS/ STRUCTURES as listed in Sch 'A' Part I.
Lump sum price worked out for EXCAVATION, EARTH WORK AND SITE CLEARANCE as listed in Sch 'A' Part II
Lump sum price worked out for INTERNAL WATER SUPPLY as listed in Sch 'A' Part III
Lump sum price worked out for INTERNAL ELECTRIFICATION as listed in Sch 'A' Part IV
Lump sum price worked out for ROAD/ PATH/ HARDSTANDING/ CULVERT as listed in Sch 'A' Part V
Lump sum price worked out for SEWAGE DISPOSAL as listed in Sch 'A' Part VI
Lump sum price worked out for AREA DRAINAGE as listed in Sch 'A' Part VII
Lump sum price worked out for EXTERNAL WATER SUPPLY as listed in Sch 'A' Part VIII
Lump sum price worked out for EXTERNAL ELECTRIFICATION as listed in Sch 'A' Part IX
Lump sum price worked out for FIRE FIGHTING SYSTEM as listed in Sch 'A' Part X
Lump sum price worked out for LIGHTENING PROTECTION as listed in Sch 'A' Part XI
Lump sum price worked out for Supporting items for LIFT as listed in Sch 'A' Part XII
SCHEDULE 'A' PART - XIII MISCELLANEOUS ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signifies this fact only. Bidder shall insert their rates in Green filed under Col-6.
INTERNAL WATER SUPPLY
S & F overhead shower single function square overhead shower 150 x 150 mm flow with air effect (ABS body & face plate chrome plated) with rubit cleaning system 16 mm dia complete all as specified and directed.
S & F Wall mixer 3 in 1 with flange provision for overhead shower with 115mm long bend pipe on upper side, connecting legs & wall flanges complete all as specified and directed.
S & F wall mounted sink mixer with swivel spout & flange complete with fittings & fixture complete all as specified and directed.
S & F 80mm dia bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S & F 65mm dia bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S & F 15mm stop valves, fancy type, chromium plated, with long shank and cup (concealed type), screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S & F angular stop cock 15 mm bore of pipe with wall flange chromium plated stop valves complete all as specified and directed.
S & F liquid soap dispenser with metallic bottle complete all as specified and directed.
INTERNAL ELECTRIFICATION
M & L for Sub main wiring with approved colour coding as per IS withFour runs of single core PVC insulated FRLSH cable with stranded copper conductor of size 6.0 Sq mm nominal area and drawing into PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc two run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Four runs of 6.0 sqmm cable,two run of 6.0 sqmm cable and one run of PVC heavy duty conduit will be measured as one unit
S & F for wall mounted LED box type tube light fitting 4' x 20 watts industrial commercial interior batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc with warranty of 5 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed.
S & F for LED tube light fitting with aluminium housing 2 feet x 10 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting with warranty of 5 years from date of installation complete all as specified and as directed.
S & F for LED tube light fitting with aluminium housing 2 feet x 5 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting with warranty of 5 years from date of installation complete all as specified and as directed.
S & F for Decorative wall mounted luminaire made out of Nickle finesh square base with bend pipe with unbreakable globe glass suitable for LED bulb and provosion of LED bulb 10 watts complete all as specified and as directed.
S & F for energy efficient exhaust fan of 225 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing wall for fan base compelte all as specified and directed. (Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be included in overall rate quoted).
Supply and Installation of Smart Single Phase Meter of different makes (Not more than 33 % of a particular make) including polycarbonate boxes with transparent cover to view meter display with the following specifications: (a) AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 5A-60A, with 3200 impulses per KWh,LED for Phase presence & LED for Relay status, conforming to IS-16444 standard with inbuilt 865-867 MHz 6 Low PAN Mesh Radio Frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LCD based display only with compatible IP54 compliant polycarbonate box for outdoor mounting with optical port Provision on meter box.
Meter Should support the following data : 15/30 min instantaneous data for Voltage, Current, Power factor, Power, Cumulative energy and frequency, monthly billing data & antitamper features. Load survey data for 45 days with 30 min integration period for kWh, Voltage, Current, frequency etc. Meter should have connect / disconnect functionality operable from prepaid billing software & shall show balance on display The meter should support open communication protocol DLMS with the software
Note :- (a) The contractor should be responsible from removing the existing meter, noting down the reading and depositing it with the MES. (b) It should run the meter in both prepaid and postpaid mode (c) The meters should carry 5 year warranty. d) OEM shall have own NABL accredited lab for testing meters as per IS 16444 and certification shall be provided during sample approval (e) The meter cost would include DCU/ Gateway and repeater cost for RF commuication meters
Supply and Installation of Smart Three Phase Meter of different makes (Not more than 33 % of a particular make) including polycarbonate boxes with transparent cover to view meter display with the following specifications: AC Three Phase Four Wire, Tamper Proof, Static Meter of Class 1.0, 3x240 V, 50 Hz, 10A-60A, with 1600 impulses per KWh & KVArh,LED for Relay status, conforming to IS-16444 standard with inbuilt Cellular or inbuilt 865-867 MHz 6Low PAN Mesh Radio Frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LCD based display only with compatible IP54 compliant polycarbonate box for outdoor mounting with optical port Provision on meter box
Meter Should support the following data : 15/30 min instantaneous data for Voltage, Current, Power factor, Power, Cumulative energy and frequency, monthly billing data & antitamper features. Load survey data for 45 days with 30 min integration period for kWh, Voltage, Current, frequency etc Meter should have connect / disconnect functionality operable from prepaid billing software & shall show balance on display The meter should support open communication protocol DLMS with the software
Note :- (a) The contractor would be responsible from removing the existing meter, noting down the reading and depositing it with the MES. (b) It would be possible to run the meter in both prepaid and postpaid mode c) The meters would carry 5 year warranty. d) OEM shall have own NABL accredited lab for testing meters as per IS 16444 and certification shall be provided during sample approval (e) The meter cost would include DCU/ Gateway and repeater cost for RF commuication meters
Supplying, Fixing, Commissioning and testing of configuration of cloud based prepaid software for with following modules: (i) Meter Data Management Module: The meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. The system would support offline meter data entry. The meter data management system would capture and provide the following data: (a) 30min instantaneous data from all the meters for seven parameters- Cumulative Energy,Power, Current, Voltage, Power factor and Frequency. b) Monthly and quarterly billing survey data for cumulative energy and max demand, Load Survey Data, Tamper Events
(ii) Communication module: The system should provide communication of energy data and bills via print, email. (iii) Meter Master Data : The system would support meter data repository. The system should support meter replacment process. (iv) Excel Export : The system would support export of metering and billing data in excel format
Supply, installation, commissioning and testing indoor type LT wall mounting Bldg panel board of suitable size factory made TTA panel, weather, dust & vermin proof indoor, double door, front openable, locking arrangements made out of 2.00 mm thick mild steel CRCA sheet including required comparment for fixing of four (04) Nos single phase smart meter, MCCB and MCB and porviding glass view for reading of meter and providing rubber/ PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/ sleeves with maintained the colour code and copper strip/ wire busbar of suitable size to MCCB input and MCCB/ MCB output of suitable length for connection of cable from main busbar, angle iron 50 mm x 50 mm x 5 mm thick supporting frame including applying two coats of powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfaces for 3 phase 4 wire system 415/ 440 volts grade including internal wiring connections for all outgoing / incomming cable, earthing teminals , danger plate, suitable PCC platform complete all as directed.
OUTGOING (a) MCB, Tripple pole & neutral, 63 amps, 415 volts, ‘C’ curve, 10 KA all complete as specified and as directed - 06 Nos (Officers Accn) (b) MCB, single pole & neutral, 10 amps, 240 volts, ‘C’ curve, 10 KA all complete as specified and as directed - 1 No (Stair case lighting) (c) Slot for fixing the three phase smart prepaid meter - 06 Nos (Cost of Smart meter cost will be paid seperately under respective itemly)
S & F for metal clad box suitable for 230 volt 50 Hz AC supply three pin with MCB SP 20Amps including removal of old unserviceable one complete all as specified and as directed complete all as specified and as directed.
M&L for framed brakets of angle iron, flat iron, made to shape required including welding etc, as frame work for basement of water tank confirming to Fe-410 or Fe-310-0 including MS sheet base complete all as specified and as directed.
ROAD/ PATH/ HARDSTANDING/ CULVERT
M & L providing and painting 2.5mm thick, exc 100mm width road marking strip (rero reflective) of specified shade / colour using hot thermoplastic material by fully /semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T & P, cleaning of road surface of dirt, seals, oils, grease and foreign material etc complete all as specified and directed.
M & L for preparation of newly concrete surfaces of kerb stone and applying two coats of water base paint over a coat of primer complete all as specified and directed.
EXTERNAL WATER SUPPLY
M & L for cutting existing DI tubing 100 mm dia in position and making arrangements for insertion of DI Tee equal 100 mm x 100 mm x100 mm dia for branch line etc with necessary provision of push on joint (rubber gasket joint) for new water connection complete all as specified and directed.
M&L for Ductile iron fitting for spigot socket pipe such as bends (any type, radius and angle) tapers any type (straight, bend increasing, decreasing or double socket etc). Tee pieces single branch. "Y" junction, double branch, cross (All socket or socket and spigot) collars, restrained joint, mechanical joint, caps & plugs 80 mm to 100 mm dia bore including cutting and jointing new positions complete all as specified and directed.
Supply, installation, testing and commissioning of monoblock, self-priming, single-stage, centrifugal volute type pump set having cast iron casing, enclosed type dynamically balanced phosphor-bronze / SS impeller, high tensile steel shaft, carbon steel stuffing box (sealed by mechanical seal), deep groove ball bearings, base plate, mounting channel frame, elastomeric insulation, accessories and fittings, viz. mechanical seal, pressure gauges, thermometers, drains, coupling, coupling guard, vibration isolation arrangement by means of spring / rubber type mounting and TEFC squirrel cage induction motor, suitable for operation on 3- Phase, 415 V ± 10%, 50 Hz AC supply and having IE- 3 efficiency and conforming to IS 12615: 2018 of capacity 5.0 HP, suitable for 300 LPM dischage of water flow and 36 Mtr head complete all as specified and directed. Note :- Necessary civil work viz. foundation for placement of pump, mounting of pump accessories shall be covered in the scope of work.
Supply and fixing cast iron foot valve, confirming IS 4038 ,Installation, testing of size 50 mm dia complete all as dircted and specified .
M & L for Construction of Block Masonry Valve Pit of size 600 mm x 600 mm x 800 mm internal dimension, 200mm thick PCC block wall in cement mortar 1:4 on 100 mm thick PCC 1:4:8 (40mm graded aggregate) in Foundation, Rendering 15mm thick internally and externally upto 150mm below GL, providing 3.0mm thick MS Sheet Valve Pit Cover, welded with 40X5mm Flat Iron Frame alround including provision of Hinges, Handle and Locking Arrangement and 40 x 40 x 6mm Angle Iron Frame fixed on Top of Valve Pit by means of Holdfast 150mm long, embedded in PCC 1:2:4 (20mm graded aggregate) Block of size 230 x 200 x 100 mm, applying two coats of Anti-corrosive Paint over a coat of Red Oxide Zinc Chrome Primer after preparation of all exposed to Steel Surfaces including necessary Earth Work in Soft/Loose Soil complete all as specified and directed.
M & L for Construction of Block Masonry Valve Pit of size 450 mm x 450 mm x 600 mm internal dimension, 200mm thick PCC block wall in cement mortar 1:4 on 100 mm thick PCC 1:4:8 (40mm graded aggregate) in Foundation, Rendering 15mm thick internally and externally upto 150mm below GL, providing 3.0mm thick MS Sheet Valve Pit Cover, welded with 40X5mm Flat Iron Frame alround including provision of Hinges, Handle and Locking Arrangement and 40 x 40 x 6mm Angle Iron Frame fixed on Top of Valve Pit by means of Hold fast 150mm long, embedded in PCC 1:2:4 (20mm graded aggregate) Block of size 230 x 200 x 100 mm, applying two coats of Anti-corrosive Paint over a coat of Red Oxide Zinc Chrome Primer after preparation of all exposed to Steel Surfaces including necessary Earth Work in Soft/Loose Soil complete all as specified and directed.
EXTERNAL ELECTRIFICATION
Supply, laying and testing of Double Wall Corrugated (DWC) high density Polyethylene (HDPE) pipes of 120mm outer dia/ 103.5mm internal dia and stiffness class-8 (SN-8) with ISI marked (with CML no) with and including all fittings and jointing material for sewage line laid in trenches as specified in IS 16098-2013 part-2 complete all as specified and directed. Note:- Construction method shall be strictly comiled as per clause no A-4 of Annex IA of ISA 16098 Part II.
Supply, laying and testing of Double Wall Corrugated (DWC) high density Polyethylene (HDPE) pipes of 90mm outer dia/ 76mm internal dia and stiffness class-8 (SN-8) with ISI marked (with CML no) with and including all fittings and jointing material for sewage line laid in trenches as specified in IS 16098-2013 part-2 complete all as specified and directed. Note:- Construction method shall be strictly comiled as per clause no A-4 of Annex IA of ISA 16098 Part II.
Supply, laying and testing of Double Wall Corrugated (DWC) high density Polyethylene (HDPE) pipes of 63mm outer dia/ 50mm internal dia and stiffness class-8 (SN-8) with ISI marked (with CML no) with and including all fittings and jointing material for sewage line laid in trenches as specified in IS 16098-2013 part-2 complete all as specified and directed. (For EES-120, LIFT-90) Note:- Construction method shall be strictly comiled as per clause no A-4 of Annex IA of ISA 16098 Part II.
S & F for LED Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 protection security light fitting luminaire of capacity 60 watts with high power LEDs as light source and electronic driver, 4kV inbuilt and 10 kV external surge protecton with Top opening driver cover for easy maintenance with warranty option of 5 years from date of installation with pre wired and necessary mounting arrangements and provision of 4 sq mm three core copper conductor cable multi stranded from fitting terminal to street junction box complete all as specified and directed.
S & F for Security light junction box of size 205 x 255 x 112 mm for luminaries, weather proof made out of polycorbonate housing fire retardant, non fusing, shock & rust proof, single piece moulded and cover with hinged door, pole/ wall mounting type comprising of MCB SP 10 Amps, fixed on PCC foundation with screws complete all as specified and directed.
Supply ,fabrication, installation and testing of LT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protection made out 3.15 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) . All extension link/ inter connection shall be insulated with heat shrinkable colour coaded sleeves to accomodate and including the following accessories:-.
OUTGOING:- (a) 4 Pole MCCB 100 Amps with rotary handle, adjustable thermal magnetic release type, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links - 02 Nos (for Fire Fighting panel & Lift Panel) (b) 4 Pole MCCB 63 Amps with rotary handle, adjustable thermal magnetic release type, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 08 Nos (for Bldg supply+ spare) (c) MCB TPN 32 Amps with breaking capaccity 10 KA - 01 No (d) Multifunctional Digial type timer Switch (Astro type having longitude and latitude of Indian cities memory) 240 volts AC Single Phase - 01 No (e) Power contractor 3 Pole, 40 Amps, 415 Volts, 50 Hz - 01 No (f) Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter - 01 No.
M & L for maintenance free Chemical earthing of technology 3 mtr long 25.0 mm dia with 250-micron Copper coating and UL listed. There should be terminal for connection of 150 x 50 x 6 mm with 4 holes of 12 mm dia along with 2 bags of 25 Kgs each of earth enhancing compound. The chemical compound should be tested and certified by any NABL accredited laboratory with 95 percent carbon content. The testing laboratory should be an ISO 9001 and 14001 certified. The earth enhancing compound should be IEC 62321. The ph value of compound should be 7-8. Electrode should be duly tested and certified by CPRI, Govt of India for a min short circuit current of 25 kA rms for 1 Sec. including necessary boring of suitable dia upto required depth in any type of soil for inserting copper rod and filling of chemicals and Poly plastic pit cover of material- polymer body & cover dimensions- 308 mm (L) x 308 mm (W) x 214 mm (H) bearing capacity 7.5 Ton approved from NABL approved Lab complete all as specified and as directed. (For IES-4, LIFT-06, LIGHTENING PROTECTION-06, EWS-02, EES-10)
Note:- (i) Earthing is to be done infront of the Engr-in-Charge. (ii) Test Results of earthing to be submitted by the contractor for all earthings. (iii) The Contractor shall have to give written guarantee for maintenance earth resistance of less than 1.0 Ohm for the period of 10 (Ten) years after certified date of completion and shall bdeposited 2000/- per earthing as security deposit for a period of Ten (10) Years. (iv) Failing to maintain resistance of earthing less than 01.0 ohm , new earthing to be provided by the contractor with out any extra cost. (v) Necessary earth work, excavation shall be carried out in any type of soil strata, retuning, filling in and making good surronding area complete and rate quoted shall include these elements.
FIRE FIGHTING SYSTEM
S & F for Flange ended Y strainer/ Basket strainer made from CI body and having SS- 304 perforated sheet screen, class PN 1.6 of size 80mm dia bore complete all as specified and directed.
S & F for ,testing and commisoning GI heavy duty ERW pipe of following size/ bore dia as per IS- 1239 Part-1, including all accerssories such as flanges, tees, bends, rudecers jointing with welding/ nuts and bolts and providing supporting with structural work fabricated from standard sections, (MS Rounds, Angles, Channels etc) and making chases in brick/ RCC walls, slabs etc and painting with the 2 coat of first quality enamel paint on pipe exposed to suface complete all as specified and directed.
150 mm dia bore
100 mm dia bore
80 mm dia bore
65 mm dia bore
50 mm dia bore
40 mm dia bore
25 mm dia bore
NOTE: (i) Standard GI fittings with welded joint shall be used on the pipes. (ii) All hangers, clamps, brackets etc. shall be of galvenized iron. (iii) Welding of any kind on galvenised support / hanger shall not be permitted. (iv) The pipe size 100 mm NB & below shall be GI 'C' class Heavy duty as per IS 1239-1: 2004 & IS 1239-2: 2011.
M & L for Hydrant valve single headed of size 63 mm dia complete all as specified and directed.
M & L for Hose box for hose reel 20 mm dia size of 30 Mtr length complete with coupling branch pipe and nozzle MS sheet 2 mm thick complete all as specified and directed.
S & F for Cast iron Flange ended Foot Valve, confirming to IS 4038 of following sizes complete all as specified and directed.
100 mm dia bore
80 mm dia bore
S & F for Forged Brass Air Release Valve of size 25 mm dia confirming IS 554, with polypropylene float, forged brass seat and chamber, stainless steel spring, nitrile rubber ring complete all as specified and directed.
M & L for Pipe support for all types of pipes including hangers, fasteneres, elbows, supports, tees fabricated with GI sections complete all as specified and directed.
Supply ,fabrication, installation and testing of Motor Control LT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protection made out 2.0 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 54 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. Motor Control LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) complete and including the following accessories:-
S & F testing & Commission of MICRO processer with Digital Display fire control Panel with Single Panel of capacity for 99 Detector & 99 Module upto 200 detector & modules fitting with autoatic battery charger including Maint free battery , including lamp with all connected accessories '2' Zone complete all as specified and directed.
M&L for anunciating devices addressable control module complete all as specified and directed.
S & F of the following AUTO GLOW signages made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board for following, complete with mirror fasteners complete all as specified and directed.
Fire lift of size- 4" X 12"
Emergency Exit of size- 4" X 12"
Fire Hydrant of size- 4" X 12"
Fire Hose Reel of size- 4" X 12"
"DCP" Fire Extinguisher of size- 8" X 4"
"CO2" Fire Extinguisher of size- 8" x 4"
In case of Fire, do not use lift, use staircase of size- 8" x 8"
Flow Arrow Directions Sign
fire pumps names & details flow rate etc, complete
Other Sign Board as per fire Norms
S & F of 4.50 kgs light-weight squeeze grip CO2 type fire extinguisher, conforming to IS 15683: 2006, with CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel with wheel type valve, discharge nozzle, bend & horn, wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and as directed.
S & F 4.50 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc.complete all as specified and as directed.
S & F for 9 litre Mechanical foam type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted with gunmetal union, high pressure CO2 gas cartridge, hose and ABS type branch pipe and wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directed.
S & F for 9 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and as directed.
S & F Galvanized mild steel Fire bucket (Filled with dry sand & water) conforming to IS 2546: 1974 round bottom type enamel painted, white inside & Red out side and Letter "FIRE" in black out side and handle with mounting bracket complete all as specified and as directed.
S & F for Galvanized mild steel Fire hook bracket with 3 mtr bamboo handle painted with red colour complete all as specified and as directed.
S & F Galvanized mild steel Fire breater bracket with 3 mtr bamboo handle painted with red colour complete all as specified and as directed.
M & L for Fire point construted with angle iron frame mounted on PCC platform with PCC 1:3:6 and covered with GI Sheet painted with red colour and letter "FIRE" in top of shed complete all as specified and as directed.
(Note: Contractor to submit detailed construction drawings of lift design being provided with complete technical specifications as per IS: 14665 to accepting officer for approval before place the order to OEM. (a) Load capacity : 884 Kg (b) Speed : 1.0 mtr/ sec with single speed motor (c) Power Supply : 415 volts, 3 phase, 4 wire AC, 50 Hz (d) Type of Drive : AC variable voltage & variable frequency (AC V 3F regenerative closed loop). (e) Type of Machine : PM gearless & directly coupled traction machine located above shaft. (f) Car size : Minimum 2.20 sqm of floor area as per relevant IS & available shaft size as per drawings. (g) Car door : Automatic Center opening with V3F door drive sliding type, stainless steel, hairline finish (N 304) for car and landing doors at all floors.
(h) Car enclosure : Standard manufacturing with MS frame & stainless steel hairline finish (N-304) in standard thickness including 2 Nos, 10 watts LED decorative light fitting on ceiling and covered with translucent acrylic cover fitted with stainless steel frame and concealed axial flow fan with stainless steel grill and covered with stainless steel wire mesh. (j) Terminal buffers : Special spring buffers (k) Door opening (Inside) : 900 mm (width) x 2000 mm (Height) (As per relevant IS code & NBL). (l) Counter weight shall be of cast iron as recommended by OEM. (m) Car & counter weight Guide : Guide rails of `T' Section Mild steel as per OEM design (n) Clear Hoist size : As per drawings enclosed. (o) Flooring : Aluminum chequered plate 5mm thick complete (p) Signals: Combined luminous hall buttons with VFD hall position indicators (hall buttons with HPI) at all floors.
(q) Car position indicator:- (i) Monochrome LCD with blue background & white front. (ii) One No car operating panel with Luminous buttons for stops in stainless steel hairline finish(N-304). (iii) Car direction indicator in car & landing. (iv) Battery operated alarm bell with button & emergency light (rechargeable) alongwith suitable maintenance free battery. (v) Overload warning feature in car cabin. (vi) Fireman’s switch one No per lift to be installed at G Floor near landing door to be installed at ground floor near landing door. (vii) All signal fixture & car operating panel on stainless steel face plate (vii) Full height Standard Infra- red door Sensor with 154 criss cross beams. (ix) Built in announcing system without hand set, 7 Nos one each for car, one for each floor and including Ground floor. (x) The interior of the car should be provided with a device that audibly indicates the floor lift car has reached and indicates that car entrance/exit door is open or closed.
(Note: Contractor to submit detailed construction drawings of lift design being provided with complete technical specifications as per IS: 14665 to accepting officer for approval before place the order to OEM. a) Load capacity : 544 Kg (b) Speed : 1.0 mtr/ sec with single speed motor (c) Power Supply : 415 volts, 3 phase, 4 wire AC, 50 Hz (d) Type of Drive : AC variable voltage & variable frequency (AC V 3F regenerative closed loop). (e) Type of Machine : PM gearless & directly coupled traction machine located above shaft. (f) Car size : Minimum 2.20 sqm floor area as per relevant IS & available shaft size as per drawings. (g) Car door : Automatic Center opening with V3F door drive sliding type, stainless steel, hairline finish( N 304) for car and landing doors at all floors.
(h) Car enclosure : Standard manufacturing with MS frame & stainless steel hairline finish (N-304) in standard thickness including 2 Nos, 10 watts LED decorative light fitting on ceiling and covered with translucent acrylic cover fitted with stainless steel frame and concealed axial flow fan with stainless steel grill and covered with stainless steel wire mesh. (j) Terminal buffers : Special spring buffers (k) Door opening (Inside) : 900 mm (width) x 2000 mm (Height) (As per relevant IS code & NBL). (l) Counter weight shall be of cast iron as recommended by OEM. (m) Car & counter weight Guide : Guide rails of `T' Section Mild steel as per OEM design (n) Clear Hoist size : As per drawings enclosed. (o) Flooring : Aluminum chequered plate 5mm thick complete (p) Signals: Combined luminous hall buttons with VFD hall position indicators (hall buttons with HPI) at all floors.
(q) Car position indicator:- (i) Monochrome LCD with blue background & white front. (ii) One No car operating panel with Luminous buttons for stops in stainless steel hairline finish (N-304). (iii) Car direction indicator in car & landing. (iv) Battery operated alarm bell with button & emergency light (rechargeable) alongwith suitable maintenance free battery. (v) Overload warning feature in car cabin. (vi) Fireman’s switch one No per lift to be installed at Groung Floor near landing door to be installed at ground floor near landing door. (vii) All signal fixture & car operating panel on stainless steel face plate (vii) Full height Standard Infra- red door Sensor with 154 criss cross beams. (ix) Built in announcing system without hand set, 7 Nos one each for car, one for each floor and including Ground floor. (x) The interior of the car should be provided with a device that audibly indicates the floor lift car has reached and indicates that car entrance/exit door is open or closed.
M&L for MCCB 4 Pole, 415 Volts, of capacity 100 Amps adjustable thermal magnetic release type, 415 Volts, Ics = 100% Icu, 35 KA with breaking capacity 25 KA complete all as specified and directed.
S & F for metallic enclosure suitable for 4 pole MCCB capacity 100 Amps with complete all as specified and directed.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
technical_836670.pdf
techsummary_836670.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.43 MB
81220upload.rar
Tender Documents • 4.30 MB
BOQ_836670.xls
BOQ • 4.69 MB
1to35.rar
Additional Documents • 8.52 MB
Dwgstoupload.rar
Additional Documents • 21.68 MB
Download all tender documents and submit your bid