Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 CrAccepted-AOC FLAT NO 3 1ST FLOOR SAI KANTA APARTMENT PLOT NO 542 LAXMI SAGAR BHUBANESWAR 754142 | BHUBANESWAR | JAGATSINGHAPUR | ODISHA | 754142 | ₹2.2 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹2.6 Cr+₹33.7 L (15.1%)Rejected-AOC | ₹2.6 Cr+₹33.7 L (15.1%) | L2 | Rejected-AOC Rejected |
| 3 | Rejected-Technical | - | - | Rejected-Technical Non fulfilling of eligibility criteria as per clause No.11 of the DTCN |
Tender Value
Refer Docs
EMD Value
₹2.4 L
Closing Date
15 May 2020, 5:00 pmClosed
Superintending Engineer
O/o Superintending Engineer,CentralCircle,R.W.BBSR
Const. of 2nd floor of existing office of the Engineer-in-Chief, Rural Works, Odisha office building including FACADE Design(Facelift) of Front side in the Dist. of Khurda for the year 2020-21
2020_CERWI_60847_1
Tender Online CC-05 of 2020
National Competitive Bid
Civil Works - Buildings
Item Rate
330 days
Bhubaneswar
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
₹2.4 L
Yes
19 Aug 2020
1 May 2020
19 May 2020
1 May 2020
15 May 2020
1 May 2020
1 May 2020 - 12 May 2020
Amount
Removing old cement plaster from walls , including raking out joints 12mm deep and removing the debris away from the site with all lead and lift including cost of all labour and T&P etc.complete in all respect as per the direction of Engineer-in-charge.
Dismantling of brick masonry in cement mortar including stacking the useful material for reuse material for reuse and removing the debris including all cost of labour, T&P, etc. complete in all respect as per the directions of Engineer-in-charge.
Dismantling and removing R.C.C columns, beams, slab, staircase, landing, lintels, corbels .including stacking the useful materials for reuse and removing the debris away from the site all lead and lift including cost of all labour etc.complete in all respect as per the direction of Engineer-in-charge.
Dismantling and removing doors, windows and ventilators .including removal of frame, hinges, fastening and stacking the same for reuse and removing the debris away from the site.within all lead and lift including cost of all labour, etc.complete in all respect as per the direction of Engineer-in-charge.
Dismantling and removing 2.5 cm thick grading concrete from roof slab , cleaning the surface ,lowering and removing the debris away from the site within all lead and lift including cost of all labour etc.complete in all respect as per the direction of Engineer-in-charge
Removing old tarfelt from roof slab, cleaning the surface, lowering and removing the debris with all lead and lift including all cost of labour etc. complete as per the directions of Engineer-in-Charge.
Removing white wash or colour wash by scrapping with wire brush and sand paper and preparing the surface smooth including necessary repairs to Cracks and joints etc. including all cost of labour etc., including all lead and lift all complete as per the directions of Engineer-in-Charge.
Dismantling and removing cement concrete including stacking the useful materials for reuse and removing the debries away from the site with all lead and lift including cost of all labour etc. complete in all respect as per the direction of Engineer-in-charge.
Dismantling and removing C.I /PVC Pipes required dia after taking out the pipes, manually or by mechanical means, stacking of pipes including all cost of labour, materials etc., including all lead and lift all complete as per the direction of Engineer-in-Charge.
Up to 25 mm dia
32mm to 40mm dia pipes
Dismantling and removing C.I/D.I/PVC Pipes required dia after taking out the pipes, manually or by mechanical means, stacking of pipes including all cost of labour, materials etc., including all lead and lift all complete as per the direction of Engineer-in-Charge.
75 to 80 mm dia pipe
100 mm dia pipe
150 mm dia pipe
Dismantling and removing chajja shelves, fins and parapet including stacking the useful materials for reuse and removing the debries including all cost of labour etc. complete as per the direction of Engineer-in-Charge.
Removal of existing solar panel unit with all fiiting and fixtures, including stacking the materials and re installation for the same including all cost of labour, materials etc. complete as per the direction of Engineer-in-Charge.
Disposal of building rubbish / malba /rock/ similar unserviceable, dismantled or waste materials by mechanical means within 1km Lead away from the site, including loading, transporting, unloading to approved dumping ground or as approved /directed by Engineer-in-charge, including cost labour, conveyance, T&P etc. as per the direction of Engineer-in-charge.
RENOVATION/NEW CONSTRUCTION
Earthwork in excavation of foundation in all kinds of soil including dressing and levelling the bed up to the required depth & removing the excavated earth & depositing the same away from the work site within initial lead of 50 mtr & initial lift of 1.5 mtr, including cost of labour T&P articles required for the work including shoring, shuttering, propping & dewatering if required, etc. complete in all respect as per the specification & direction of the Engineer-in-Charge.
All kinds of soil
Upto 1.5 Mtr Depth
Filling in foundation, plinth and side of foundations etc. with excavated earth including watering and ramming with cost, conveyance, royalties of all materials and cost of labour with T&P required for the work etc. complete as per the specification and direction of the Engineer-in-charge.
Filling in foundation, trenches and plinth with river sand , well watered and compacted in layers with top surface dressed and leveled to proper gradient including cost of all materials, labour, sundries, T&P, all royalties, loading and unloading etc. complete as per the specification and directions of the Engineer -in-charge.
Providing and laying of Cement Concrete of grade (1: 4 :8) nominal grade using 40mm downgraded hard crusher broken granite aggregate of approved quality from approved quarry ,mixing in concrete mixer ,lowering, laying and compacting in proper level, thickness including curing for the required period, including all cost of material, conveyance,royalties, sundries , T&P etc. complete as per specification and direction of the Engineer-in-charge.
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement:2 Coarse sand) to match the existing floor:
With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Providing and laying in position RCC M25 grade concrete using 20 mm downgraded hard crusher broken granite chips of approved quality from approved quarry, mixing in approved mechanical concrete mixer in proportion to be determined by trial mixes and compacting to proper shape and size level and plumbs and maintaining the clear cover of concrete member not less than 45mm confirming to the approved specification IS 456 and 516 and finishing the exposed surface smooth, scaffolding watering and curing for the required period, excluding the cost of centering, shuttering, and reinforcement but including admixture in recommended proportions to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer- In - Charge. including cost all materials, conveyance , royalties , loading and unloading, cost of all labour, sundries, T&P etc.complete.
Foundation & Plinth
Ground Floor
First Floor
Second Floor
Providing, fixing in position TMT/Fe-500 reinforcement bars for RCC work of required diameter of approved quality including straightening, cutting, bending, binding, welding and jointing (if necessary) and tying the grills and placing in position as per approved design and drawing ,including cost of materials, conveyance of steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all heights as per the specification & direction of Engineer -in-charge.
Foundation & Plinth
Ground Floor
First Floor
Second Floor
Providing steel centering and shuttering(steel plate/ ply board) to required shape and size for all kinds of R.C.C. works, centering materials with all necessary props, bracing, ties and supports with level centering using bituminious paper wherever required, as per the direction of the Engineer -in-charge and dismantling and removing the shuttering after the required interval from the date of casting, including cost of all materials with transportation, loading and unloading etc. and all labour, sundries, T&P scaffolding etc. complete.
Foundation & Plinth
Footing
RCC Wall
Ground Floor
RCC Wall
First Floor
RCC Wall
Second Floor
stub column
Roof Beam
Lintel
RCC Wall
RCC Fins
Masonry work using A.A.C (Autoclaved aerated concrete) blocks of approved size having compressive strength not less than 4N/mm2 conforming to IS:2185 (Part- 3)-2005 and IS:6441-1972 in cemcnt mortar of mix 1:6 (1 cement :6 screened and washed sand) for use in superstructure including splays cutting, circular moulding, corbelling,chamfering and similar such type of works ,watering and curing etc.including cost conveyance , royalties, loading and unloading of all materials & cost of all labour, materials ,scaffolding , sundries, T & P etc. complete as per the direction of Engineer-in-charge .
Ground Floor
First Floor
Second Floor
Masonry work using A.A.C (Autoclaved aerated concrete) blocks of approved size having compressive strength not less than 4N/mm2 conforming to IS:2185 (Part- 3)-2005 and IS:6441-1972 in cemcnt mortar of mix 1:4 (1 cement : 4 screened and washed sand) for use in superstructure including splays cutting, circular moulding, corbelling,chamfering and similar such type of works ,watering and curing etc.including cost conveyance , royalties, loading and unloading of all materials & cost of all labour, materials ,scaffolding , sundries, T & P etc. complete as per the direction of Engineer-in-charge .
Second Floor
Supplying, fitting and fixing in WPC Door frames of size 115 mm X 55 mm which is in contact with concrete and masonry surface fitted with required W.I. Clamps and required screws of approved quality etc. fixing in CC 1:2:4 including cost, conveyance and taxes of all materials and cost of all labour, sundries, T & P etc. required for all the work complete as per the directions of Engineer -in-charge.
Second Floor
Providing 12mm thick cement plaster to the surface of masonry wall with cement mortar (1:6) including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats only to proper plumbs and level and making grooves and beads to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading and royalties, all labour, scaffolding, watering and curing, sundries and T&P etc all complete as per direction of the Engineer -in-charge
Ground Floor
First Floor
Second Floor
Providing 16mm thick cement plaster to the surface of brick masonry wall with cement mortar (1:6) including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats only to proper plumbs and level and making grooves and beads to give required ornamental finish as per approved drawings including cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing, sundries and T&P etc all complete as per direction of the Engineer -in-charge
Ground Floor
First Floor
Second Floor
Providing 6mm thick cement plaster with cement mortar of (1:4) to ceilings of roof slabs, stairs, landings, chajja, shelves, columns, beams and lofts etc. including roughening, scraping and cleaning and finishing the plastered surface smooth using wooden floats only to proper plumbs and level, making grooves and beads to give required ornamental finish as per approved drawings including cost of all materials, conveyance, loading and unloading, and royalties, all labour, scaffolding, watering and curing , sundries and T&P etc all complete as per direction of the Engineer -in-charge
Ground Floor
First Floor
Second Floor
Supplying and applying an elastic liquid, crack bridging 2 pack acrylic polymer modified cementitious waterproofing coating system conforming to IS 2625,IS 101 and ASTM D 2370 in two coats in the Toilet portions. The surface should be dampen immediately ahead of the compound application. Whilst the surface is still damp from saturation a first coat of the waterproofing primer is applied then followed by a single coat of the waterproofing compound and leave to harden for 2-6 hrs.After the application of the first layer of the coating another fabric coating is spread over it, which is again followed by a final & top coat of the water proofing compound. Proper curing must be done after application of the waterproofing system for a minimum of 3 to 5 days to ensure full cement hydration and to minimize cracking. Generally 0.7 kg and 1.5 kg of the compound is used to cover one square meter of area in the first coat and second coat respectively..The cost is inclusive of materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing , sundries and T&P etc all complete as per direction of the Engineer -in-charge.
Second Floor (Toilets)
Supplying, fitting and fixing Vetrified tile in floor of specified size and approved make conforming to IS-13755 laid on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 sand) and filling joints with epoxy based water proof grout of approved quality to match the shades of the tiles etc.including cost of all materials,labours & royalties, conveyance ,loading and unloading ,sundries ,T & P etc .complete as per the specification & direction of Engineer-in-charge.
Size of tile 800x800 mm
Second Floor
Supplying, fitting & fixing Vetrified tile in dados skirting of specified size and approved male conforming to IS-13755 over 12mm thick cement mortar 1: 3 (1 cement : 3 sand) and filling joints with epoxy based water proof grount of approved quality to match the shades of the tiles to proper line and level to a height as per design including cutting to required size and shape, fixing at corners and splays etc. including cost of all materials,labours & royalties, conveyance ,loading and unloading ,sundries ,T & P etc .complete as per the specification & direction of Engineer-in-charge.
Size of tile 800x800 mm
Second Floor
Supplying, fitting and fixing Granite in floor/steps using 16-18mm thick granite slab of approved quality, colour and size over 20mm thick cement mortar (1:4) and finishing the joints with epoxy based water proofing grout to match the colour & shade of tiles including cutting to shape, grinding and wax polishing, cost of all labour, materials, royalties, loading and unloading, conveyance, sundries, watering and curing etc. complete as per drawing and direction of the Engineer -in-charge.
Second Floor
Supplying, fitting and fixing Granite in Skirting using 20mm thick granite slab of approved quality, colour and size over 12 thick cement mortar (1:3) and finishing the joints with epoxy based water proofing grout to match the colour & shade of tiles including cutting to shape, grinding and wax polishing, cost of all labour, materials, royalties, loading and unloading, conveyance, sundries, watering and curing etc. complete as per drawing and direction of the Engineer -in-charge.
Second Floor
Supplying, fitting and fixing 16-18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut Granite slab for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Second Floor
Supplying, fitting and fixing best quality Anti skid Ceramic floor tile of size 300x300 mm of approved make confirming to IS-15622 specifications in floor over 20mm thick cement mortar (1: 4) to proper slope, line and level including cutting to required size and shape, fixing at corners and splays etc. including finishing the joints with epoxy based water proofing grout to match the color and shade of tiles complete as per the design & drawing with cost of all materials, labour, conveyance,T&P etc. all complete as per the direction of Engineer -in-charge.
Second Floor
Supplying, fitting and fixing 300 x 600 ceramic glazed wall tiles of approved size conforming to IS: 15622 specifications of approved make and shade, in skirting and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and finishing the joint with epoxy based water proofing grout to match the shade including cost of all material, labour, conveyance, T&P etc. complete as per the direction of Engineer-in-charge
Second Floor
Supplying, fitting and fixing 12 mm thick frameless toughened with 70 micron etched glass Partition of approved brand with machine polished edges including top & bottom patches,QBPF-3(TOP 1500mm long),QBPF-3(BOTTOM 1500mm long), as approved by the EIC with all arrangements and making necessary holes etc. complete, including all cost of labour, material, conveyance, T&P etc.as per direction of Engineer-in-charge
SUpplying, fitting and fixing 12 mm thick frameless toughened etched glass door shutter of approved brand with machine polished edges, including top & bottom pivot & spring type fixing with an approved make including 450mm Stainless steel handle QBGHL-5(H-Handle),QBPF-3(TOP 1500mm long),QBPF-3(BOTTOM 1500mm long),Double cylinder floor spring(QBFS-74) as approved by the EIC with all arrangements and making necessary holes etc. all complete, including all cost of labour, material, conveyance, T&P etc.as per direction of Engineer-in-charge
Providing,fitting and fixing ISI marked flush door with both side laminated shutters confirming to IS 2202(Part1) of 33mm thickness including ISI marked necessary hardware fitting with approved colour paint over a coat of primer etc and hardware fittings such as SS Concil Hinges (5"),stopper,,SS Tower bolt-8",Mortise lock Handle etc. including cost of all labours, materials, conveyance, hardware fixing,loading and unloading, all taxes and royalties, sundries and T&P etc all complete as per direction of the Engineer -in-charge. (Toilet)
Second Floor
Supply, fitting and fixing of partly fixed partly openable glazed uPVC Window made out of hollow multi chambered uPVC sections having isolated drainage system with the design Casement (Outside open) The casment frame of the window having over all size of 60 x 52 mm having internal wall thickness of 3.00 mm. The glass panel shall be made out of Upvc sections with over all size of 60 x 78 mm with internal thickness of 3.00 mm. Reinforcement of galvonised mild steel with thickness of 1.50 mm has to put throughout the frame, glass panel. Glass support beading make of upvc sections will be fixed with EPDM gaskit to keep glass tight. Single point locking system (called Cockspur) made out of casted zamac with white powder coated and Friction and Stray Hinges will be made of SS 304 grade material. Multipoint locking system (called Espag) made out of casted zamac with white powder coated can be used if height goes beyond 4.50 feet. The model and brand of the uPvc window shall be approved by the Engineer -in- charge before fixing. Glass thickness and colour will be change as per requirement.
Second Floor
Supply and fixing of uPVC Sliding glazed Window made out of hollow multi-chambered uPVC sections having isolated drainage system with the design 2 Track 2 Panel System. The 2 track outer frame of the window having over all size of 98 x 52 mm (with mosquito mesh) having internal wall thickness of 2.50 mm. The glass sashes / shutters shall be made out of Upvc sections with over all size of 42 x 70 mm with internal thickness of 2.50 mm. The mosquito mesh shutter having over all size of 25 x 52 mm with internal wall thickness of 2.50 mm. Reinforcement of galvonised mild steel with thick ness of 1.50 mm has to put through out the Frame, glass shutter and mesh shutter. Glass support beading make of upvc sections will be fixed with EPDM gaskit to keep glass tight and unmoved. Single point locking system (called touch lock) made out of casted zamac with white powder coated and locking hook will make of SS 304 grade material. Aluminum guide rail will be fixed on the Bottom part of frame on which the glass shutters will run. The roller will make of nylon an having capacity of 40 - 120 kg depends on glass weight. Finseal will be provided to protect the dust in between closing point & interlocking point of glass & mesh shutters. The Interlock of the uPVC window should be approved by the Engineer-in- charge before fixing. Glass thickness and colour can be changed as per requirement.
Ground Floor
First Floor
Second Floor
Supply and fixing of upvc glazed fixed glass window made out of hollow multi-chambered uPVC sections having isolated drainage system with the design Casement (Outside open coupled with fixed) The window frame having over all size of 60 x 52 mm having internal wall thickness of 3.00 mm. There will be no additional glass panel to the, glass will be fixed with the frame itself. Reinforcement of galvonised mild steel with thickneness of 1.50 mm will have throughout the frame. Glass support beading making of Upvc sections will be fixed with EPDM gaskit to keep glass tight. The model and brand of the uPvc window shall be approved by the Engineer -in- charge before fixing. Glass thickness and colour will be change as per requirement.
Ground Floor
First Floor
Supply and fixing of uPVC Top Hung glazed uPVC ventilator made out of hollow multi chambered uPVC sections having isolated drainage system with the design Casement (Outside open) The casment frame of the window having over all size of 60 x 52 mm having internal wall thickness of 3.00 mm. The glass panel shall be made out of Upvc sections with over all size of 52 x 78 mm with internal thickness of 3.00 mm. Reinforcement of galvonised mild steel with thickness of 1.20 mm has to put throughout the frame, glass panel. Glass support beading make of upvc sections will be fixed with EPDM gaskit to keep glass tight. Single point locking system (called Cockspur) made out of casted zamac with white powder coated and Friction and Stray Hinges will be made of SS 304 grade material. Multipoint locking system (called Espag) made out of casted zamac with white powder coated can be used if height goes beyond 4.50 feet. The model and brand of the uPvc window shall be approved by the Engineer -in- charge before fixing. Glass thickness and colour will be change as per requirement.
Ground Floor
First Floor
Second Floor
Supplying and fixing glass and louvered uPVC ventilators having a frame size of 60mm width x 45mm height and wall thickness of 2.25 mm.The upvc frame is reinforced throughout with galvanised steel of 1.2mm thickness. The glazing provided is of thickness 5mm frosted glass both in fixed glass and in louvers.The sash has a size of 60 width x 45 height and wall thickness 2.25 mm reinforced with galvanised steel throughout.The model and brand of the upvc ventilator shall be approved by the EIC before fixing.The rates shall be inclusive of all cost of materials,labour,T&P etc. complete.
Ground Floor
First Floor
Second Floor
Supplying, Fitting and Fixing M.S Grills of approved designs made out of M S Flat, Square bars/Round bars etc. of approved specifications / dimensions with necessary welded clamps fixed in proper position & plumb including a single coat of priming of approved quality metallic primer, making required holes in Masonary Walls / R.C.C Structures (where necessary) and grouting the clamps with C.C(1:2:4) with 12mm size black hard crusher broken granite stone chips, making good to the damages of Masonary Walls / R.C.C Structures including cost, conveyance, loading, unloading,stacking, royalties , cost of all labours, staging, scaffolding, sundries, T&P etc. complete as per the direction of the Engineer-in-charge.
Supplying ,fitting and fixing of 12 mm thick Toughened glass railing of 1m ht. with 50mm dia SS Rail mounted inside for safety and vertical SS supports upto 25mm x 50mm tubes with min 2mm thickness fixed to the floor using adequate number of fasteners as per the approved shop drawing.
Second Floor
Supplying ,fitting and fixing of Railings using MS Framework in staircase , balcony ,utility an etc. as per approved design and specification including buffing, polishing etc with cost ,conveyance of all materials,labours,T&P etc complete in all respect as per the direction of Engineer-in-charge.
Second Floor
Providing & fixing of 6 mm thick High pressure Laminate of approved make fixed with frames made up of powder coated aluminum tube of weight 1300 grams & thickness 0.9 mm with stainless steel screw & rivet including the cost of all materials, labour,etc as per the direction of Engineer-in-charge. (colour & shade to be approved before procurment & use)
Ground Floor
First Floor
Second Floor
Painting two coats with synthetic enamel paint of approved colour, shade and brand on new wood work to give an even shade including an under coat of suitable primer of approved brand and manufacturer including cost of all materials and transportation, loading, unloading, scaffolding, all labour, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge.
Ground Floor
First Floor
Second Floor
Painting two coats with Plastic emulsion paint of approved brand and manufactures to give an even shade over a coat of putty and primer of approved brand including cost of all labours, materials, conveyance, loading and unloading and royalties, sundries and T&P etc complete as per direction of the Engineer -in-charge.
Second Floor
Painting two coats with water soluble weather coat paints of approved shade of approved make or equivalent over a coat of primer outside surface of new walls after scraping, cleaning the surface including all cost of materials, labour T&P etc complete as per direction of Engineer -in-charge.
Ground Floor
First Floor
Second Floor
Providing one coat of Textured finish of approved make, quality and shade over the wall surface of the building over a coat of primer of approved make including cost of material, all labour loading, unloading, scaffolding, T&P etc. as required for the work as per the direction of Engineer-in-charge. (colour & shade to be approved before procurment & use)
Ground Floor
First Floor
Second Floor
Providing & Installing external cladding using fibre cement plank manufactured by wet recessed autoclaved technology uncolored plank teak texture (External Grade) thickness 8mm and dimension 150mmX3000mm. The Fibre cement plank should be of minimum density 1300kg/ m3 (±50) and comply to ASTM C 1185 and ISO 8336 part (E) for confirming durability properties and BS 476 – part 5, 6 & 7, Thermal conductivity should be minimum 0.15 W/m˚K and PH value should be in the range of 7 – 8. ).Depending on height of structure planks to be fixed using Aluminum frame section of 50mm x 25mm of suitable gauge (within1mm thick) with minimum spacing 450mm to 600mm or as per direction of Engineer In charge. Uncolored teak planks to be fixed using screws of Tensile strength 34N and Shear strength 68N on framing. Screw heads are covered with acrylic putty of the next plank giving uniform natural groove/over lap(as per approved drawing ). All plank to plank joints to be staggered & finished with one coat of cement based primer on all side, with 2 coats of water based acrylic paint of approved shade.
Supply, Installation of Structural Glazing with 6mm thick reflective toughened glass ST 467 of approved make as per elevation drawings & detailed technical specification enclosed using heavy duty aluminium extruded built up profiles.The rates shall be inclusive of all cost of materials,labour,T&P etc. complete in all respect as per the shop drawing submitted by contractor and approved by EIC. but exclusive of spandrel insulation & smoke seal which shall be paid for separately.
Applying Spandrel Insulation & Smoke seal:The Rate shall include Providing and Fixing of Spandrel Insulation at spandrel glazing area of the Curtain Glazing with Frosted toughened glass , fire stop cum smoke seal in spandrel area with 0.7 mm thiuck GI sheet / 2 mm thick aluminium sheet with pure polyester powder coating upto 60 micron thick in approved shade, fabricated in a tray form at a minimum distance of 50 mm from inner face of glass with 50 mm thick resin bonded fiber glass / mineral wools of 48 Kg/CuM density with black non woven fiber glass tissue ( BGT) facing on one side fixed between the tray and slab to form a smoke stop. The whole assembly shall be fixed to aluminium framework by Stainless Steel screws of M 8 x 25 and the periphery gap between the Powder coated GI sheet frame & aluminium frame work shall be sealed by weather silicone sealant of approved make.etc complete in all respect as per the shop drawing submitted by contractor and approved by EIC.
Supply, Installation of Powder Coated Louvers with Outer frame as 25 mm x 50 mm x 1.5 mm tubular frame and Channel suitable to Louver Panels with Panel dimension as 56.5 mm without bend with wall thickness as 2 mm with two nos of screws grooves. Outer frame shall be Cut into Rectangular or Square sizes or as per site requirements with mitered joints and CSK screws. Main frames shall be fixed onto the Civil openings with approved make HFV anchor fasteners of M10x80. Louver Panels shall be fixed onto the main frames by SS Screws of PH M10x50 of approved make.
Providing and fixing Glass Reinforced Concrete (G.R.C) Cornice in approved size, pattern, design, shade and thickness of 50mm on frame and design element in 30mm thick have weight approximately between 3.5 - 4 Kg per Sq . Ft. The above weight and thickness is considering dimensions of screens up to required height and width. The fixing of Screens should be 'Dry fixing' i.e. to be done with M .S Galvanized Clamps, fixtures and fastehers . including cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing, sundries and T&P etc all complete as per direction of the Engineer -in-charge.
PEB structure with Tubular Steel Frame for Roof Top Extension
Structural Framework: - The Structural Framework shall be made out of Built up Factory made Modules and Pillars of MS Sections as per structural design considerations. The Primary Steel sections shall be designed as per latest load calculations based on IS:875, IS:1893, IS:800, IS:801, IS 2062 etc. The scope also includes design and detailing. WIND LOAD AND SEISMIC LOAD: The wind load are considered in accordance to IS: 875-Part-3, 1987. The wind speed for the site has been considered at 50m/s. The design for seismic load Zone - 4 should be considered as per IS 1893( Part-1) 2002 clause 7.5.3. Sloping Roof: Sloping roof shall be done using pre coated galvalume iron profile sheets 0.5 mm+/-5% TCT thk. The sheet shall be fixed using self-drilling self-tapping screws with EDPM seal. Polynum Thermal wrap 8 mm double bubble with both side high resistance aluminum foil of 12 micron each, with wire mesh will be provided below the Roof sheet
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
Supplying, Drilling/Cleaning hole and injecting ETA Approved for seismic rebar RE500V3 chemical. Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023 or relevant tested and accepted rebar guidelines. The chemical should have ETA approval for seismic rebar as a minimum qualifying criteria. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery operated dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. The adequate diameter and embedment of rebars to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/ design engineer for approval. Scanning with PS250 Scanning Tool before drilling to be done to avoid hitting existing rebars. The rate mentioned includes cost of all labours, materials, conveyance, loading and unloading and T&P etc.
8mm dia rebar at 160mm depth
10mm dia rebar at 200mm depth
12mm dia rebar at 240mm depth
16mm dia rebar at 320mm depth
20mm dia rebar at 400mm depth
25mm dia rebar at 500mm depth
Chemical Anchoring
Providing and supplying Shock, Seismic (C1 & C2), Fatigue and Fire approved, ETA approved HIT-RE500V3 with HIT-V Threaded Rod to use in cracked/uncracked concrete, tested for service temperature of -40 deg. C to +80 deg. C. The product should be approved by ETA, ICC, CSTB, COLA, BZS. Anchoring with HIT-V with RE500V3 to be designed as per guidelines of TR 029. Drilling hole with double flute type drill bits/ hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery operated dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. The adequate embedment depth & number of anchors to be calculated as per PROFIS Anchor Software & the report to be submitted to the project manager, design engineer for approval. Scanning with PS250 Scanning Tool before drilling to be done to avoid hitting existing rebars. For zones with high seismicity, seismic designs are mandatory. For shear loads, base plate designed by SOFA, filling sets are mandatory. The rate mentioned includes cost of all labours, materials, conveyance, loading and unloading and T&P etc.
HIT-RE 500 V3 with Anchor rod HIT-V-5.8 M10X125
HIT-RE 500 V3 with Anchor rod HIT-V- 5.8 M12X150
HIT-RE 500 V3 with Anchor rod HIT-V- 5.8 M16X185
HIT-RE 500 V3 with Anchor rod HIT-V- 5.8 M20X240
HIT-RE 500V3 with Anchor rod HIT-V- 5.8 M24X300
Mechanical Anchors
Supplying, drilling/cleaning hole and fixing of ETA approved Torque Controlled, ETA approval for Seismic C1 & C2, Fire approved upto 120 minutes, FM Approved Expansion Anchor HST3 pre assembled with galvanized bolt & nut, stainless steel ingenious expansion sleeve of sizes ranging from M8 to M24. Anchor shall be fixed at right embedment depth as per embedment mark and activated using SIW 6AT A22 Tool Module to ensure adequate torque as per manufacture’s torque tolerance published in ETA and same shall be documented and submitted to Project Manager at the time of inspection. Design of Anchor should be done as per ETAG 001 Annex C and TR045 using PROFIS Software as per actual load data and site conditions as provided by structural consultant and the report to be submitted to the project manager and design engineer for approval. Scanning before drilling to be done with PS250 Scanning tool to avoid rebar hits. The rate mentioned includes cost of all labours, materials, conveyance, loading and unloading and T&P etc.
Safety stud anchor HST3 M8x95/30
Safety stud anchor HST3 M10x110/30
Safety stud anchor HST3 M12x115/20
Safety stud anchor HST3 M16x145
Safety stud anchor HST3 M20x170/30
Safety stud anchor HST3 M24x200/30
Safety stud anchor HST3-R M8x95 -/30 (SS316)
Safety stud anchor HST3-R M10x110 50/30 (SS316)
Safety stud anchor HST3-R M12x115 40/20 (SS316)
Safety stud anchor HST3-R M16x145 45/25 (SS316)
Safety stud anchor HST3-R M20x170 -/30 (SS316)
Safety stud anchor HST3-R M24x200 -/30 (SS 316)
RCC CORE CUTTING
RCC core cutting withDD 200 machine with 3.2 Kw motor and SPX core bits etc . The rate mentioned includes cost of all labours, materials, conveyance, loading and unloading and T&P etc.complete as per direction of the Engineer -in-charge.
100 mm dia. and 125 thick slab
150 mm dia. and 125 thick slab
INTERNAL PH & SANITARY WORKS
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778 of SDR-11, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge
50 mm dia
40 mm dia
32 mm dia
25mm dia
20mm dia
Supplying all materials,labour,T&P & fitting and fixing of following different water supply fittings as per ASTMD-2846 with supply of all necessary jointing materials etc all complete as per direction of Engineer-in-charge.
50mm dia CPVC ball valve
40mm dia CPVC ball valve
32mm dia CPVC ball valve
25mm dia CPVC ball valve
Supplying all labour , T&P and materials & making grooves in brick/stonewall vertically and horizontally to the required depth & width for fixing pipes & fitting in grooves , testing the pipe line against the leakage & filling the grooves with CM ( 1:4) to bring the surface to the original level including the cost of the machine , conveyance etc all complete as per the direction of Engineer-in-charge.
15mm to 32mm dia pipe
Supplying all materials labour,T&P and cutting holes through existing brickwork including supply of all materials & making good the damages for taking PVC pipes and fittings etc all complete as per PH specification and direction of the EIC
In all floor
20mm to 50mm PVC to pass in 125mm to 250mm thick Brick/stone wall
Supplying all materials , labour T&P and cutting hole in RCC floors,roofs,etc for passing PVC pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4) including finishing complete so as to make it leak proof as per direction of the EIC
20mm to 50mm PVC to pass in 125mm to 250mm thk RCC
Providing & Fixing Wash Down Water Closet (European type W.C pan) with integral ‘S’ or ‘P’ trap conforming to IS 2556 : Part 8-2004, to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specification. MAKE :- HINDWARE/ JAQUAR/ PARRYWARE/ Equivalent. Wall Mounted water closet with Intergrated type Flushing Cistern Water Closet- HINDWARE DOME 92517 Starwhite/ Equivalent Concelaed cistern- HINDWARE CONCEALO 80MM / Equivalent, Flush Plate- HINDWARE NOVA
Providing and fixing of following size Wash Basin with 175mm Long Wall Connection Pipe including painting of fittings and brackets, cutting and making good the walls wherever required with provision for pillar cock but excluding the cost of pillar cock, including all cost of labour, material, conveyance, loading, unloading, T&P etc. all complete as per the direction of Engineer-in-charge. MAKE :- HINDWARE/ JAQUAR/ PARRYWARE/ Equivalent. Under Counter Wash basin of size Size : 44 cm dia- HINDWARE ROUND CODE NO.10065 Starwhite/ Equivalent
Providing and fixing white vitreous china urinal set with Installation Box with Control Cock with 175mm Long Wall Connection , including painting of fittings and brackets, cutting and making good the walls and floors wherever required as per the direction of Engineer-in-charge. Urinal- HINDWARE DYNA CODE NO.60010 Starwhite/ Equivalent Urinal Sensor Flushing,Battery operated HiNDWARE PARTCODE 500964 /Equivalent
Providing and fixing 8mm thick frosted glass partition for urinal with patch fitting, clamps etc including cost of all labour, material, sundries and all chrome hardware fitting etc all complete as per the direction of Engineer-in-charge. (JAQUAR CODE NO. JSE-CHR-185C3236H19X/Equivalent)
Providing and Installing Modular Fresh Color Restroom Cubicles Systems of made up of 12 mm thick HPL Boards fixed with accessories of stainless steel grade 304 such as SS “U” Channel,SS “F” channel,SS Top Rail,SS Coat Hook,SS Privacy Thumb turn c/w Occupancy Indicator,SS Door Knob,SS Hinges with Cover,SS Adjustable Foot - 316 Grade,Rubber Lining for Groove,S.S.Screws 304 G & P.V.C Wall Plugs.etc.including cost of all labours, materials, conveyance, loading and unloading, all taxes and royalties, sundries and T&P etc all complete as per direction of the Engineer -in-charge.
Size of Cubicle : 1000mm (W) X 1550mm (D) X 1980mm (H)
Door Size : 1750mm (H) X 610mm (W)
Overall Height Of Cubicle : 1980mm (Including bottom Gap of 150mm)
Supplying all materials, labour, taxes, T & P for fitting & fixing of different water supply CP , Brass or GM concealed fitting and fixtures of ISI approved make of following sizes and specification with leak proof threaded joints tightened with spun yam and white zinc or any other method as required and directed including testing and rectification of defects after testing,including cost of all labours, materials, conveyance, loading and unloading, all taxes and royalties, sundries and T&P etc all complete as per direction of the Engineer -in-charge..
Pillar cock ((HINDWARE CORA F440001/Equivalent)
Health faucet((HINDWARE F160068/Equivalent)
Angle stop cock HINDWARE CORA F440005/Equivalent)
Soap Dish (HINDWARE RUBBIC F870004/Equivalent)
Towel Ring (HINDWARE F870003/Equivalent)
Robe Hook (HINDWARE RUBBIC F870007/Equivalent)
TOWEL RAIL (HINDWARE RUBBIC F870012/Equivalent)
PAPER HOLDER (HINDWARE RUBBIC F870008/Equivalent)
GLASS SHELF (HINDWARE RUBBIC F870011/Equivalent)
Twoway Bibcock (HINDWARE CORA F440004/Equivalent)
Bottle Trap (Hindware Cat no-F850015/Equivalent)
Waste Coupling (HINDWARE Cat F850002/Equivalent)
Urinal Spreader
Automatic Hand drier- (JAQUAR Cat HDR-WHT-M04A/ Equivalent)
Liquid Soap dispenser- (JAQUAR Cat ACN-1135N/ Equivalent)
15mm dia CP flange
CP grating including floor trap
15mm dia CP extension piece
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
110mm dia UPVC pipe(Type-A)
Supply all materials ,labour,T&P,fitting and fixing UPVC SWR Type B pipes & fittings of approved make confirming to IS-13592 including jointing of approved solvent cement non-heat application method including testing of as per standard specification ,both below & above ground level/floor & on walls including supply of bobbins,nains,screws,wooden cleats ,pipe clamps as per requirement including earthwork excavation & fitting ,including cutting walls & floor & making good the damages with cement concrete (1:2:4) with hard granite chips ,including scaffolding wherever necessary all complete with requisite testing as per direction of the EIC (Make: ASTRAL/SUPREME/EQUIVALENT)
75mm dia UPVC SWR pipe(Type-B)
110mm dia UPVC SWR pipe(Type-B)
Providing and laying in trench cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 20 mm nominal size) bed concrete as per drawing and detail design etc including cost of all labours, materials, conveyance, loading and unloading, and royalties, sundries and T&P etc all complete as per direction of the Engineer -in-charge.
TYPE A1 Standard Bedding 110 mm dia
Supplying all materials, labour, T&P and fixing PVC water storage tanks of as required capacity confirming to IS:12701-1996 including cutting holes through the tank and fixing pvc pipe and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including conveyance of all materials to worksite etc all complete as per specification and direction of Engineer-in-charge.(Sintex/Equivalent)
Providing and fixing pvc gully trap complete with grating brick masonry chamber with water tight SFRC cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 100x100 mm size P type. including cost of all labours, materials, conveyance, loading and unloading, all taxes and royalties, sundries and T&P etc all complete as per direction of the Engineer -in-charge.
With flyash bricks of minimum compressive strength 75kg/sqcm
Constructing brick masonary road gully chamber 45x45x77.5cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) with precast R.C.C. vertical grating complete as per standard design Including all cost of labour, material, T&P etc. all complete as per the direction of Engineer-in-charge.
With flyash bricks of minimum compressive strength 100kg/sqcm
Constructing brick masonary chamber for underground SFRC inspection chamber and bends with bricks in cement mortar 1:4 (1 cement:4 coarse sand) SFRC cover with frame 455x610mm internal dimensions, total weight of cover with frame be not less than 38kg (weight of cover 23kg and weight of frame 15kg), R.C.C. TOP SLAB WITH 1:2:4 mix (1 cement: 2 coarse sad :4 graded stone aggregate 20mm nominal size ), foundation concrete 1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design Including all cost of labour, material, T&P etc. all complete as per the direction of engineer in charge.
Inside dimensions 600x850mm and 45cm deep for pipe line with three or more inlets:
INTERNAL ELECTICAL WORK WITH FITTINGS
WIRING-:
Recess Wiring for light point/ fan point/ exhaust fan/wall fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with 1way modular switch, modular plate, suitable GI box including supplying the same and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
First Point
Group A
Group B
Group C
Looping Point .
(Controled by same switch-Gr.A wire Only)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire for 6A PP looping
2 X 2.5 sq. mm + 1 X 1.5 sq. mm earth wire for 15A PP & Switch Boards & Computer points
2 X 4.0 sq. mm + 1 X 2.5 sq. mm earth wire for AC Point.
2 X 6.0 sq. mm + 1 X 4 sq. mm earth wire for AC Point.
4 X 4 sq. mm + 2 X 2.5 sq. mm earth wire for L .DB & C.DB
4 X 6 sq. mm + 2 X 4 sq. mm earth wire for P.BDB
4 X 10 sq. mm + 2 X 6 sq. mm earth wire for P.BDB,VRF AC
4 X 16 sq. mm + 2 X 10 sq. mm earth wire for P.BDB,VRF AC
2 X 10.0 sq. mm + 1 X 6.0 sq. mm earth wire AC Point.
Supplying and drawing following pair 0.5 sq mm FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.(Terminet at G.floor EPABX room)
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing metal box of 1.63 mm thick following sizes (nominal size) on surface or in recess without cover including cutting the wall and making good the same in case of recessed conduit ,also including painting etc as required.
75 mm X 75 mm X 60 mm deep
100 mm X 100 mm X 60 mm deep
150 mm X 75 mm X 60 mm deep
200 mm X 125 mm X 60 mm deep
250 mm X 300 mm X 60 mm deep
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3nos 3 pin 5/6 amps modular socket outlet with 2nos 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2nos 3 pin 5/6 amps modular socket outlet with 2nos 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 amps modular Socket , connection etc. as required.
Supplying and fixing of Telephone socket out let with suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing , connection etc. as required.
Supplying and fixing of TV antenna socket out let with suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing , connection etc. as required.
Installation, testing and commissioning of wall bracket /ceiling fittings /LED down light of all sizes and shapes containing upto two GLS lamps per fitting, complete with all accessories including connection etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan on down rod or wall fan on the existing ceiling /surface, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan with shutters/louvers in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Upto 450 mm sweep
Installation, Testing and Commissioning of resistance type ceiling fan regulator, in existing box including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor, earthing the regulator as required.
Supplying and fixing of support arrangement for fixing of cable tray, light fittings ,Panel Board etc with MS angles / flats / rods /anchor flashner/extra rod for fan & Lights including jointing the steel sections of the support arrangement with nuts & bolts / welding / Febicating complete as required .
SDB'S, MCB, ISOLATOR,CABLE,PANELS-:
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4 + 12), Double door
6 way (4 + 18), Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way (2 + 6), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Single pole & Neutral
Supplying and fixing following rating, Four pole, 440 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, (three phase andneutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying the following Size PVC/ XLPE insulated PVC seathed Alluminium aromour cable of 1.1 kV as per IS 1554 etc as reqd.
4 core 10 sq.mm-WS PANEL
4 core 16 sq.mm-WS PANEL
3 1/2 core 25 sq.mm-LIFT PANEL
3 1/2 core 35 sq.mm
3 1/2 core 50 sq.mm-VRF AC PANEL
3 1/2 core 70 sq.mm-VRF AC PANEL
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Above 25 sq. mm and upto 120 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs/copper for following size of PVC insulated and PVC sheathed / XLPE aluminium/copper conductor cable of 1.1 KV grade as required.
a- 4 core 10 sq.mm
a- 4 core 16 sq.mm
a- 3 1/2 core 25 sq.mm
a- 3 1/2 core 35 sq.mm
a- 3 1/2 core 50 sq.mm
a- 3 1/2 core 70 sq.mm
Panels .
Design, supply, installation, testing and commsioning of cubicle main panel for indoor/Outdoor installation of wether prrof design as per IP 44 class, made out of 2 mm thick CRCA sheet as per the drawing with cubicle type inernal arrangement of 1.6 mm thick sheet and with front & back opening system suitable for mounting following switch gears, busbars, metering unit, including painting with powder coated paint of approved colour and shed with earthing the body etc as reqd including all other materials & . as directed by site-incharge.. (drawing shall be approved by engineer -in charge)
Floor Pnel Board = (Indoor Wall mounted type-)
Incommer:- 02 nos. 125A.,25KA FP MCCB(Microprocessor based) .
Incommer:- Electroechanical interlocking beween 2 I/C MCCBs
Busbar:- 04 nos.200A. Al. bus bar duly sleeved,25KA.
Outgoing:-i) 25/32A TPN,10 KA MCB-4nos,40/63A TPN,10KA MCB-2nos
1nos-100A,25KA TP+NL MCCB ,3nos 25A,10kA SPN MCB
Instrument:- i) 06 nos. phase indicating lamp with control fuse
ii) 02 Set of (0-200)A MFM, Digital with CT & PT
(Duly factory wired)
VRF AC Panel= (Outdoor FLOOR mounted type)
Incommer:-1nos-100A,25KA FP MCCB
Outgoing:-i) 2nos 40A,300mA FP RCCB & 1no 25A,300mA FP RCCB,1no 25A 10KA,FP MCB
03 nos. phase indicating lamp with control fuse
(Duly factory wired)
Earthing
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with CU earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm x 5 mm CU earth strip ISI marked at 0.5 meter below grond level as strip arth electrode including soldering etc. as required
Supplying and laying 25 mm x 5 mm G.I earth strip ISI marked at 0.5 meter below grond level as strip earth electrode including soldering etc. as required
FITTING & FIXTURE-:
Supplying of of PVC Exhaust fan 250 mm dia suitable to work on 230/250 volts, 50HZ complete with mounting Frame and louvers including making the hole to suit the size of above fan, making good the damage, connections, with 1.5 sq.mm PVC insulated, copper conductor, single core cable etc as per EIC of approved make including with all,., materials & labour..(Make Usha-Crisp Air or Equiv.-HYBEC/Havells/Bajaj)
Supplying of 1200 mm energy efficient ceiling fan as per EIC of approved make including with all,., materials & labour. .(Make Usha-Striker or Equiv.-HYBEC/Havells/Bajaj)
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
Supply, Installation, Testing, and commissioning of 400mm Wall mounted fan complete with 1.5 sq.mm PVC insulated, copper conductor,single core cable etc as required as per EIC.(Make -Usha-Mistair, /Equiv HYBEC / Havells /Khaitan )
Supply, Testing & commissioning of Surface or wall mounting 1 x 20W LED tube light fitting including 1 no. of 20watt LED luminairs as per EIC of approved make including with all,., materials & labour.. (Make WIPRO-Model-LL20-221-XXX-65NE3 make Philips /JAQUAR/ HAVELLS)
Supply, Installation,Testing & commissioning of Recess mounted squre LED Luminaire with complete diffuser with for 1 x33W LED inluding of approved make complete with all materials & labour(Make :Wipro,Cat No.-CRCO10R033HP57UGR/Equiv.-Philips /JAQUAR/ HAVELLS)
Supply, Installation,Testing & commissioning of recess mounted round White LED downlighter with pressure die cast aluminium housing & PMMA diffuser suitable for 9/10W LED fitting includded luminairs of approved make complete with all materials & labour..(Make :Wipro,Cat No.-LD90-111-XXX-65-XX */Equiv.-Philips /JAQUAR/ HAVELLS)
Supply, Installation,Testing & commissioning of recess mounted round Warm White LED COB spot downlighter with aspecial frosted diffuser suitable for 6W LED fitting including 6 watt LED luminairs of approved make complete with all materials & labour..(Make :Wipro,Cat No.-LD98-131-024-40-XX*/Equiv.-Philips /JAQUAR/ HAVELLS)
Supply, Installation,Testing & commissioning of Flexible Warm White LED strip Light of 15W/Spoolwith Driver for cove lighting including all other materials as required.(Make :Wipro,Cat No.-LS06-015-120-WW-50/Equiv.-Philips /JAQUAR/ HAVELLS)
Supply, Testing & commissioning of wall mounting 1 x 10W LED wall mounted IP-65 bulk head fitting including 10watt LED luminairs as per EIC of approved make including with all,., materials & labour.(Make WIPRO-Model-LW07-141-XXX-57-XX/SS make of Philips /JAQUAR/ HAVELLS)
DATA WIRING :-
Supplying and Laying of 4 pair CAT 6 UTP, PR-PVC LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. (Make: Legrand/AMP/ Digisol)
Supply & Fixing of fully loaded 24 ports cat-6, patch panel suitable for rack mounting as per EIC of approved make including with all, materials & labour..(Make: Legrand/AMP/ Digisol)
I) 24 port
Supply & Fixing of 2mtr / 1mtr long Cat6 Factory crimpped moulded, LSZH Patch Cord as per EIC of approved make including with all, materials & labour..(Make: Legrand/AMP/ Digisol)
For 1 mtr. Long
For 2 mtr. Long
Sypply and Fixing of 15U Wall Mounting Server rack with 2xFANs, 1x4Skt 6/16AMP PDU with required nos.Cable manager and 1pkt H/W Screw Packet. Make: Valrack/Legrand/APW
Supply & Fixing of Rack Mounting 24 Port 10/100/1000Mbps Layer 2 Managed Switch with 4 Gigabit SFP Ports as per EIC of approved make including with all,materials & labour... (Make: Cisco/Legrand/Digisol)
Supply & fixing of Cat-6 information outlet box with face plate suitable for RJ 45 terminals including mounting box (G.I/PVC) , to be fixed in concealed manner in partition/wall by necessary bolts & nuts or as directed by site-incharge. (Make: AMp/Legrand/Digisol)
Termination & link testing of LAN cable at both the end including all other materials as directed by site-incharge.
INTERIOR WORKS
PLAIN GYPSUM CEILINGWITH ST 50 :- Providing and fixing Gypsum board Ceiling - 12.5mm th. single layer gypsum board fixed on suspended G.I. tubular channels as per manufacturers' specifications, including jointing, finishing with gypsum compound, jointing tape and top coat. The surface shall be duly sanded and finished. Rate shall include vertical faces of ceilings including pelmet andshall include cost of marking as/ reflected ceiling plan and making all the necessary cutouts for lights, grills,diffusers etc. The rate shall also include providing perimeter channel for grills, lights, diffusers as called for in HVAC and Electrical Drawings.The rate shall also include providing for edge/ angle bits at all corners, necessary taping, filling with jointing compound as per manufacturers specifications. The rate shall be exclusive of trap door which shall be paid for separately. including all cost of materials , labour, overheads T & P etc., complete.
Providing, and painting the Gypsum Board ceiling area with one coat of primer & two coat of flame spread resistence paint as per the detail design and specification.
16mm thick USGBORAL Pin Pirf™ ClimaPlus™ Tile with Micro Line T Grid 15mm:- Supplying and Fixing of USGBORAL Suspended ceiling system components. This includes Micro Line black reveal T grid Wall angle of 19mmx15mm shall be screw fixed to brick wall/partition with the help of approved screws at 600mm centers. Then suspending Micro Line black reveal T Main T grid of 15mm x 35mm of length 3600mm from RCC Slab. The Main T is hung with USGBORAL adjustable level clips & 4mm diameter GI rod which are connected to Soffit Cleat and Approved Fasteners @1200mm centers or as approved. The Cross T of 15mm x 35mm of 1200mm length shall be interlocked between main T Grid at 600mm centers to form 1200 x 600mm modules. 600 x 600mm modules to be formed by click fitting Cross T of 15mm x 35mm of 600mm length centrally between the 1200mm cross T’s. Then 16mm thick USGBORAL PinPirf™ ClimaPlus™ ceiling panel having FLB edge of size 595x595 shall be placed into the above grid of size 600x600mm. This ceiling panel confirms to ASTM E84 surface burning characteristics. (Class A, Flame Spread: 25 & Smoke developed: 50) .The Ceiling panel provides NRC 0.60, CAC minimum: 35.Light Reflectance: 0.88, Thermal Resistance: R-1.7 & can withstand Relative Humidity up to RH 99% (limiting conditions –Max 490 C /99%RH).The front & back side of the tile has anti-Microbial coating. ( office ) .The rate shall be including all cost of materials , labour, overheads T & P etc., complete. as per the detail design and specification approved by Engineer -in-charge /Architect .
WOODEN RAFTER FALSE CEILING :- Providing and fixing of wooden rafter false ceilling of size 50 x125 made outof with 19 mm bwP PLY frame work and then fixing 6 mm th bwp ply to it over which is finished with 1 mm th SUEDE laminate & fixed by means of stainless steel sturds & polished with mellamine including all the cost of material & labour , t& p etc complete and as per the direction of EIC / ARCHITECT . ( BASIC COST OF LAMINAT IS RS 48/SFT )
12.5 mm thick 595X595 MR TILE with UNI T Grid 24mm :- Supplying and Fixing of USGBORAL Suspended ceiling system components. This includes UNI T grid Wall angle of 24mmx24mm shall be screw fixed to brick wall/partition with the help of approved screws at 600mm centers. Then suspending UNI T Main T grid of 24mm x 38mm of length 3600mm from RCC Slab. The Main T is hung with USGBORAL adjustable level clips & 4mm diameter GI rod which are connected to Soffit Cleat and Approved Fasteners @1200mm centers or as approved. The Cross T of 24mm x 27mm of 1200mm length shall be interlocked between main T Grid at 600mm centers to form 1200 x 600mm modules. 600 x 600mm modules to be formed by click fitting Cross T of 27mm x 24mm of 600mm length centrally between the 1200mm cross T’s. Then 16mm thick USGBORAL PinPirf ™ ClimaPlus™ ceiling panel having SLT edge of size 595x595 shall be placed into the above grid of size 600x600mm. This ceiling panel confirms to ASTM E84 surface burning characteristics. (Class A, Flame Spread: 25 & Smoke developed: 50) .The Ceiling panel provides NRC 0.60, CAC minimum: 33.Light Reflectance: 0.88, Thermal Resistance: R-1.7 & can withstand
Realtive Humidity up to RH 99% (limiting conditions –Max 490 C /99%RH).The front & back side of the tile has anti-Microbial coating..The rate shall be including all cost of materials , labour, overheads T & P etc., complete. as per the detail design and specification approved by Engineer -in-charge /Architect . (TOILET )
WOODEN PANELING WITH LAMINATE :- Providing and fixing wooden panelling suitably fixed to the walls with 19 mm thick bwp ply , finished with 1 mm thick texture / suede laminate complete with necessary Hardwood, skirting , mouldings & teak wood beading on the edge etc. as per the detail design including the cost of all materials, labour, overheads and T & P etc. complete. The exposed frame work shall be finished with matt finsish enamel paints / polish with mellamine to match with the shade of the Laminates. ( BASIC COST OF LAMINAT IS RS 48/SFT )
PANELLING WITH LAMINATE:- Providing and fixing 75mm - 150 mm wooden panelling suitably fixed to the walls with 19 mm th bwp with suitable thickness , finished with 1 mm thick texture / suede laminate , febric , lether for head board complete with necessary Hardwood, skirting , mouldings & teak wood beading on the edge etc. as per the detail design including the cost of all materials, labour, overheads and T & P etc. complete. The exposed frame work shall be finished with matt finsish automotive paints / polish with mellamine to match with the shade of the Laminates as per the directions of the EIC/Architect. . ( Basic price of laminate Rs 540.00/sqm )
PELMET (as per site conditions and window / ceiling intersection):-Providing and fixing in place 150mm deep pelmet made out of 19mm thick fire retardent ply wood and finished internally with automotive paint * external with 1 mm th texture / suede laminate . The pelmet to be provided at the junction of window and false ceiling ONLY as per site conditions. The pelmet to be concealed inside the false ceiling such as to recieve the vertical blinds as approved by EIc /Architect. .
DOUBLE SKINED SOLID PARTITION :- Providing , fitting and fixing95mm thick double skinned full height partition suitably fixed to the wall and floor and storage unit with19 mm th bwp ply frame work / almunium frame work of size 37mm x 63x1.6 mm with angle section 40x25x1.5 mm at 600 mm C / C with 12mm thick bwp ply on both side and finished with1mm thick LAMINTE, as per the design and specification with necessary teak wood plain / moulded beading including the cost of all materials , labour , nails, screw adhesives, overhead T & P etc. complete. The exposed frame work shall be finished with mat finish automotive paint or polish with mellamine as per the directions of the EIC/Architect. .)( Basic cost of Laminate - Rs 48.00/sft )
DOUBLE SKINED SOLID PARTITION WITH GLASS :- Providing , fitting and fixing 95mm thick double skinned full height partition suitably fixed to the wall and floor and storage unit with19 mm th bwp ply frame work / almunium frame work of size 37mm x 63x1.6 mm with angle section 40x25x1.5 mm at 600 mm C / C with 12mm thick bwp ply on both side and finished with1mm thick laminate , 8 mm th 50 micron etched glass / double pasting lacord glass , as per the design and specification with necessary teak wood plain / moulded beading including the cost of all materials , labour , nails, screw adhesives, overhead T & P etc. complete. The exposed frame work shall be finished with mat finish automotive paint or polish with mellamine as per the directions of the EIC/Architect. .)( Basic cost of Laminate - Rs 48.00/sft )
LOW HEIGHT PARTITION :-Providing , fitting and fixing 89mm thick double skinned low height partition suitably fixed to the wall and floor and storage unit with19 mm th bwp ply frame work / almunium frame work of size 37mm x 63 x1.6 mm with angle section 40x25x1.5 mm of size at 600 mm C / C with 12mm thick bwp ply on both side and finished with 1mm thick texture / suede laminate, fixed to the ply on both sides as per the design and specification with necessary teak wood plain / moulded beading including the cost of all materials , labour , nails, screw adhesives, overhead T & P etc. complete. The exposed frame work shall be finished with mat finish automotive paint or polish with mellamine as per the directions of the EIC/Architect. . ( Basic price of laminate Rs 540.00/sqm )
PARTIALY GLAZED FLUSH DOOR -
Providing and fixing ISI marked flush door with both side laminated partialy glazed shutters confirming to IS 2202(Part1) of 33mm thickness including ISI marked necessary hardware fitting with approved colour paint over a coat of primer etc and hardware fittings such as SS Concil Hinges (5"),stopper,,SS Tower bolt-8",Mortise lock Handle , door cloused etc. including cost of all labours, materials, conveyance, hardware fixing,loading and unloading, all taxes and royalties, sundries and T&P etc all complete as per direction of the Engineer -in-charge.
RECEPTION TABLE :-Providing & supplying of Reception table of size 1800X750x1200 WITH storage OF SIZE 450 Xx450x750 made out of 19 mm th bwp ply & finished with 1 mm th suede , TEXTURE laminate, glass , ss pipe, 12mm corian where ever necessary . & inner surface finished with 0.8 mm th laminate & beading to be finished with automative paint or mellamine polish including all types of material, labour , hardware etc. as per the detail design & specifications approved by EIC .
RECEPTION BACK DROP :-Providing and fixing of 75-150 thick parttition with vinyl sheet / corian / sand stone /19 MM TH Onyx as a backdrop for the Reception. The structure shall be made of 19 mm th bwp ply members 55mmx 40mm and then over it 6mm bwp ply shall be fixed and then the corian shall be fixed to the partitions. The joints shall be finished with silicon adhesive to match withe the shade of the corian. as per the detail design and specifications and inclusive of all cost of labour, materials, T&P etc complete as per the directions of the EIC/Architect.
CONSOLE / display unit :- Providing, fitting and fixing the console /display unit made of 19mm BW p ply and finished with 1mm thick texture / suede laminate , 12 mm th glass shelf whever necessary and the exposed edges& wooden surface are to be finished with wooden lipping and finshed with automative paints/polish with melamine finish as per approved design and specifications including cost of all materials, labour, hardware if any etc. complete as per the detail design & directions of the EIC.
STORAGE BELOW PANTRY PLATFORM ( MODULAR ) : -
Base Cabinets & Wall Cabinets :-Carcase is made up of BWR (Boiling Water Resistant) Plywood with Mini fix systems. Both side Laminated with all around PVC Edge Banding. Carcase Specification Details: 1. Plywood Thickness - 18 mm after both side off-White lamination & all around PVC Edge Banding. 2. Base & Wall Cabinet Height - 700 mm. 3. Wall Cabinet Depth - 350 mm (Including Shutter) 4. Base Cabinet Depth - 580 mm (Including Shutter) 5. PVC (Polyvinyl Chloride) Front Edge Banding Thickness – (2 x 22 mm). 6. Frame Thickness- 18 mm after both side lamination & all around PVC Edge Banding.
Shutters & Others Wood Works :- Shutter is made up of BWR (Boiling Water Resistant) Plywood with both side Lamination & all around PVC Edge Banding. Shelf & Base and Back Details: 1. Plywood Thickness -18 mm after both side lamination & all around PVC Edge Banding. 2. Laminate Thickness – 1 mm 3. PVC (Polyvinyl Chloride) Edge Banding Thickness – (2 x 22 mm)
Hardwares :-All Kitchen Hardwares & Fittings are from HAFLE (SS 304) or as per company standards specified.
Accessories :- All Kitchen Hardwares & Fittings are from HAFLE (SS 304) or as per company standards specified.▪ PVC Cutlery Tray- 1 Pc ▪ 4" Plain Wire Basket- 1 Pc ▪ Cup & Saucer Basket- 1 Pc ▪ Thali Basket - 1 Pc ▪ 8" Plain Basket- 4 Pc, ▪ Waste Bin Holder- 1 Pc ▪ Fixed Detergent Rack- 1 Pc ▪ Magic Corner- 1 Pc(Dores) ▪ Bottle Pullout- 1 Pc ▪ Cylinder Trolley- 1 Pc as per the detail design and approved by the EIC.
OVER HEAD STORAGE :- Providing and fixing of over head storage cabinet of depth 450 mm with out drawer with 19mm th bwp & 6 mm th bwp ply wood at the back side and finished with 1.0 mm th suede/texture laminates,8mm th glass in shutter and finished the teak wood lipping with mat finish enamel paint or polish with mellamine to match the laminate shade , internal surface finished with 0.8 mm th laminate as per the detail design and approved by the EIC.
MIRROR IN BASIN COUNTER :- Providing and fixing of 8mm th mirror with 6 mm th bwPply wood at the back side and the outer surface finished with 2.5 " th pvc beading with to match the laminate shade and as approved by the EIC.
LOW HEIGHT STORAGE 450 width :-Providin & supplying LOW HEIGHT STORAGE made out of19 mm thick bwp ply , 6 mm th bwp ply at out side & laminated with 1 .0 mm th sued/TEXTURE laminate on out side & 0.8 mm th laminate at in side , the exposed wooden surface polished with mellamine or painted with automotive paint with central locking, shutters with autoclosing hinges and handles. Including all cost of labour , taxes T & P etc as per the detail design & specificatio approved by EIC .
TRAP DOOR :- Providing and fixing trap doors for access to the areas above false ceiling. The trap door shall have an external frame made of 50mm x 50 mm in good quality seasoned wood scantling on which the shutter is hinged. Shutter shall be made of 12mm thk bwp ply and finished with 1.0mm thick laminate externally and automotive paint internally.Concealed heavy duty hinges shall be used to mount the shutters and locking shall be provided with panel locks. The shutter shall be moulded in level with the false ceiling forming a groove all around. Sufficient number of hinges and locks shall be provided to avoid sagging of the shutter. Key also shall be supplied for opening the shutter.No extra rate shall be provided for suspenders or frame works alround for linking the trap door to gypboard false ceiling. as per directions of Engineer-in-charge/Architect.
LEDGE WITH LAMINATE :- Providing and fixing of LEDGE of width 375- 450 mm on bed made out of 19mm bwp ply & 6 mm th bwp ply wood finished with 1mmth texture & suede laminates , as per the detail design and specifications approved by EIC .
OFFICE TABLE WITH SIDE EXTENTION :- Providing office table 2100X750x750 h WITH a storage 450x600x750 below the table & SIDE EXTENTION OF SIZE 975x450 X750h with drawers & shelfs made out of 19 mm th bwP PLY& finished with 1 MM TH suede laminate where ever necessary . & inner surface finished with 0.8 mm th laminate & beading to be finished with automative paint or polished with mellamine including all types of material, labour , hardware , locks ,8 mm th plain glass on the top of the table etc. as per the detail design & specifications approved by EIC .
OFFICE TABLE WITH SIDE EXTENTION :- Providing office table 1800X750x750 h WITH a storage 450x600x750 below the table & SIDE EXTENTION OF SIZE 975x450 X750h with drawers & shelfs made out of 19 mm th bwP PLY& finished with 1 MM TH suede laminate where ever necessary . & inner surface finished with 0.8 mm th laminate & beading to be finished with automative paint or polished with mellamine including all types of material, labour , hardware , locks ,8 mm th plain glass on the top of the table etc. as per the detail design & specifications approved by EIC .
OFFICE TABLE WITH SIDE EXTENTION :- Providing office table 1500X675x750 h SIDE EXTENTION OF SIZE 975x450 X750h with drawers & shelfs made out of 19 mm th bwP PLY& finished with 1 MM TH suede laminate where ever necessary . & inner surface finished with 0.8 mm th laminate & beading to be finished with automative paint or polished with mellamine including all types of material, labour , hardware , locks ,8 mm th plain glass on the top of the table etc. as per the detail design & specifications approved by EIC .
FIRE FIGHTING SYSTEM
FIRE DETECTION & ALARAMING SYSTEM :-
Supply, Installation, Testing and Commissioning of Intelligent Addressable Fire Detection and Alarm System
CONTROL EQUIPMENTS:
Supply and Installation of 32 bit microprocessor based Intelligent Addressable Fire Alarm Control panel with 2 Loops with battery back up. The panel would be modular, decentralized, with The panel shall be consisting with minimum 240 character LCD display and for networking. The Panel would be able to record atleast 60,000 events history. Each loop would be capable to have atleast 126/99 addressable detectors and addressable devices with up to 3.5km loop length. with 12V battery back up for 30 Minutes and battery charger in built . Make: MORLEY(HONEYWELL)/ FIRE LITE/ GST(PANEL WILL BE FIXED AT G.FLOOR LOBBY AREA)
Suply and Fixing of Intelligent Addressable type multicriteria detector with base for use as heat or smoke or combined both with automatic electronic addressing, microprocessor type with builtin integrated short circuit isolator including testing, commissiong etc as reqd. Make: MORLEY(HONEYWELL)/ FIRE LITE/ GST
Supply and Fixing Dual tone Hooter complete with base, mounting box, gland & all other accessories as required as per direction of Engineer-In- Charge.Make: MORLEY(HONEYWELL)/ FIRE LITE/ GST
Supply and Fixing ofIntellegent type with monitor module UL / LPCB listed Manual Call point complete with base, mounting box, gland & all other accessories as required as per direction of Engineer-In-Charge. Make: MORLEY(HONEYWELL)/ FIRE LITE/ TYCO
Supplying and Fixing of Duel LED Response Indicator. Make: MORLEY(HONEYWELL)/ FIRE LITE/ GST
Supplying & Laying of 2x1.5 sq.mm. FRLS PVC insulated single core multistrand copper conductor(Rrd Colour) of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick and including other wiring accessories etc as reqd. Make: Polycab/ Finolex/RR/KEI
Supplying and Fixing, 4Kg ABC Powder(stored Pressure type) Fire extinguishers with wall mounting brackets first filling etc. Make: SUNMAX/SAFEX/ AGNI
Supplying and Fixing, 6Kg CO2 Powder(stored Pressure type) Fire extinguishers with wall mounting brackets first filling etc. Make: SUNMAX/SAFEX/ AGNI
FIRE HYDRANT & WET RISER SYSTEM
Providing all materials, labour, T&P for laying of following dia M.S. heavy class pipes conforming to IS:1239/IS:3589 with ISI mark & required sizes of fitting like off set, bend, tee, reducer flange & flange joints etc. as per site condition including gas cutting by oxygen and acetelene gas flame, fitting and setting as per required size wherever necessary, jointing the pipes by electric welding confirming to IS specification and electrodes confirming to IS specification after 'V' grove cutting. Aligning the pipes inside the trenches including necessary excavation of earth work of required width & depth in all kinds of soil /rock and back filling or supporting/fixing the pipe on floor / wall /ceiling with clamps, hangers (using anchor fasteners) or angle iron, G.I. pipe sleeve of suitable higher size shall be provided wherever the pipes are crossing the walls/floors and sealing the sleeves with glass wool in between & fire sealent compound at either end all as per the approved specification including cutting holes and chases in brick/RCC wall/roof/chajja and making good the same to original condition. but excluding GST.
All hangers, clamps, brackets etc. shall be of galvanized iron unless specified otherwise and then supply of the same shall also be included. Painting 2 (two) or more coats with synthetic enamel paint of Post office red shade over a coat of primer for above ground level & painting 2 (two) or more coats with anticorrosive epoxy paint for below ground level. Prior to application of primer the surface should be cleaned for any dirt, rusts, rough substance etc. Including painting of legends both direction arrow as per the approved specification including testing & commissioning the system.The cost inclusive of hire and running charges of welding generator set & all taxes, duties, transportation, hire & running charges of machineries, POL, to & fro charges with all consumables for all floors etc. all complete as per specification & direction of EIC. Make-SAIL/JINDAL/TATA but excluding GST.
150mm dia (Heavy class) as per IS-1239 Part-I/2004
80mm dia (Heavy class) as per IS-1239(Part-I)/2004
65mm dia (Heavy class) as per IS-1239(Part-I)/2004
Providing, fitting & fixing of Stainless Steel fire hydrant landing valve with 80mm NB flanged inlet (Table-E Flange), SS spindle controlled 63mm dia female instantaneous outlet type. SS coupling, blank cap, chain, twist release type lug & all accessories Conforming to IS-5290 with ISI mark. Including flange joint & tapping from wet rise & testing and commissioning the system for all floors etc. all complete as per approved specification & direction of EIC.Make-KARTAR/NEWAGE/OMEX but excluding GST.
Single Landing Valve (oblique type)
Providing, fitting & fixing of following size cast iron double flanged slim seal wafer type Butterfly valves with EPDM rubber lined with lever operated as per IS-13095 with ISI mark of pressure ratting PN-1.60 including fixing the same with supply of required jointing materials like rubber insertion, MS nuts & bolts, paint etc. and testing the joints with required water pressure etc. all complete as per specification & direction of E.I.C. Make-KIRLOSKAR/IVC/ZOLOTO/VENUS but excluding GST.
150mm dia
Providing, fitting and fixing of first aid fire hose reel wall mounting swinging type fitted with 20mm dia 30.00 m long high pressure (10Kg/cm2) themo plastic hose tube conforming to IS: 12585 with ISI mark Type II with 5mm outlet stainless steel/ Brass nozzle with shut off valve confirming to IS 884-1969 with ISI mark including testing & commissioning the system for all floors etc. all complete all complete as per apporved specification & direction of EIC. Make-MITRAS/NEWAGE/MINIMAX/LIFEGUARD but excluding GST.
Providing, fitting & fixing of Non-percolating flexible hose (RRL type-'B' with EPDM Lined) confirming to IS:636 with ISI mark (63 mm dia x 15 M long) complete with instantaneous type stainless steel male and female couplings confirming to IS:903 with ISI mark wounded & riveted to hose pipe with 18 SWG stainless steel wire including testing & commissioning the system for all floors etc. all complete as per approved specification & direction of EIC. Make-KARTAR/MITRAS/NEWAGE/LIFEGUARD but excluding GST.
Providing, fitting and fixing of 63 mm dia stainless steel instantaneous male inlet pattern branch short pipe conforming to IS:903 with ISI mark suitable for interconnection to hose pipe coupling including testing & commissioning the system for all floors etc. all complete as per approved specification & direction of EIC. Make-KARTAR/NEWAGE/OMEX but excluding GST.
Providing, fitting and fixing of C.I. single air relief valve with stop cock confirming to IS:14845/2000 with ISI mark for water works purpose including fixing the same with hydrant riser including testing & commissioning the system etc. all complete as per approved specification & direction of EIC. Make-KIRLOSKAR/IVC/ZOLOTO/KARTAR but excluding GST
Providing, fitting and fixing of dial type stainless steel pressure gauge duly calibrated with isolation ball valve and short piece etc. fixed at hydrant station including testing & commissioning the system etc. all complete as per approved specification & direction of EIC. Make-ELSTER/H-GURU. but excluding GST
Dialmeter of 150mm dia of pressure rating 0-15 kg/cm2.
Providing, fitting & fixing of following size cast iron double flanged Y type strainer with SS 304 perforated screen confirming to IS 1538 with ISI mark of pressure rating PN-1.60 including fixing the same with supply of required jointing materials like rubber insertion, MS nuts & bolts, paint etc. and testing the joints with required water pressure & all complete as per specification & direction of EIC. Make-KIRLOSKAR/IVC/ZOLOTO/VENUS/HONEYWELL but excluding GST
150mm dia
Providing, fitting and fixing of MS/GI partly glazed single/double hung lockable shutter fabricated from MS/GI section as required with 5mm thick glass for fire station complete including stove enamelled painting of door and frame and words "Fire Hydrant" written on glass, suitable to accommodate 2 (two) RRL ,15m long 63 mm dia hose (RRL),1(One)-branch pipe including suitably mounted on a raised masonry/ vertical MS platform of size 0.6mx0.5mx0.25m (external type with rain cap) including testing & commissioning the system for all floors etc. all complete as per approved specification & direction of EIC. Make-OMEX/GETECH/LIFEGUARD but excluding GST
HVAC SYSTEM
REMOVAL/REINSTALLATION
Removal of Existing AC Outdoor unit with all fiiting and Fixtures, including stacking the materials and re installation for the same Including all cost of labour, materials, conveyance, T&P, etc., including all lead and lift all complete as per the direction of Engineer-in-Charge.
EQUIPMENT
Supply of Modular type VRV/VRF ,Top Dischage , Cooling Only outdoor units equipped with highly energy efficient Scroll Compressors with all inverter compressor(s) with variable refrigerant temperature and technology, tensile strength of compressor body not less than 600 MPa having compressor motor of 6 pole , each outdoor unit have external static pressure not less than 78 Pa, special designed four faces heat exchanger, ODU dB level less than 65 at a distance 1 Meter, centrifugal fan for condenser, ODU having front suction & top discharge, Y-branch as required, outdoor unit support, auto check function for connection error, auto address setting, refrigerant cooled PCB circuit at ODU and capacity as mentioned below. VRV System shall be suitable for working on 49 °C ambient temperature, Refrigerant R 410A.
Nominal Capacity - 28 HP
Supply of Indoor Units & Accessories :
Round Flow/Four Way Cassette Unit with Wireless Remote
Hi-Wall Mounted Split
SUPPLY OF ANCILLARY ITEMS
Lifting, Shifting, Positioning, Installation, Testing & Commissioning of Outdoor & Indoor Units.
Outdoor Unit :
Capacity : 28 HP
Round Flow Cassette with Sensing
Hi-Wall Split
Installation of supporting materials (GI threaded rods, anchor fastners etc.) for installation of Cu pipe, drain pipes, ODU's & IDU's.
Supply & Installation of interconnecting Copper Refrigerant pipe work with (19 mm/ 13 mm thick) nitrile rubber tubular insulation between each set of indoor & outdoor units as per
Gas line :
Liquid line :
Condensate Drain Pipe :
Supply of PVC drain pipes with 9 mm thick nitrile rubber insulation of the following size ( with L bow, Socket & Reducers)
Control & Transmission Wiring :
Supply of Control wiring of 2 Core X 1.0 sqmm copper in suitable conduits between indoor and outdoor units
Supply of GI Slotted Cable Tray for expose copper piping covered with GI sheet (24G) on terrace & in shaft if open.
50mm X 150mm X 50mm
Supply & Comissioning of Refrigerant R410A gas
ROUTRAY DEVELOPER
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .