Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹99.0 LRejected-Finance | ₹99.0 L | L1 | Rejected-Finance The tender was cancelled due to the abnormally low and unjustified rates quoted by the L1 bidder |
| 2 | L2₹1.2 Cr+₹16.5 L (16.6%)Rejected-Finance | ₹1.2 Cr+₹16.5 L (16.6%) | L2 | Rejected-Finance The tender was cancelled due to the abnormally low and unjustified rates quoted by the L1 bidder |
| 3 | L3₹1.2 Cr+₹21.3 L (21.5%)Rejected-Finance | ₹1.2 Cr+₹21.3 L (21.5%) | L3 | Rejected-Finance The tender was cancelled due to the abnormally low and unjustified rates quoted by the L1 bidder |
| Sl No | Description | Qty | Unit | SSBA BUILDERS PRIVATE LIMITED L2 | PRAVIN CONSTRUCTION L1 | V P M HOUSING L3 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling tile work in floors and roofs laid in cement mortar including
stacking material within 50 metres lead. For thickness of tiles above 25
mm and up to 40 mm | 4,310 | sqm | 108 ₹4,65,480 | 83 ₹3,57,730 Lowest | 171 ₹7,37,010 |
| 2.00 | Demolishing lime concrete manually/ by mechanical means and
disposal of material within 50 metres lead as per direction of
Engineerin-charge | 517.2 | cum | 720 ₹3,72,384 | 638 ₹3,29,973.6 Lowest | 1,250 ₹6,46,500 |
| 3.00 | Disposal of building rubbish/malba/similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading
to approved municipal dumping ground or as approved by Engineerin-charge, beyond 50m initial lead, for all leads including all lifts involved | 732.7 | Cum | 234 ₹1,71,451.8 | 195 ₹1,42,876.5 Lowest | 350 ₹2,56,445 |
| 4.00 | Providing and applying fibre reinforced elastomeric liquid waterproofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @ 10.76 litre/10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. | 4,310 | sqm | 690 ₹29,73,900 | 420 ₹18,10,200 Lowest | 500 ₹21,55,000 |
| 5.00 | Providing and fixing in position 12mm thick bitumen impregnated fiber board conforming to IS: 1838, including cost of primer, sealing compound Grade-A in expansion joints. | 13.2 | per cm depth per 100m | 540 ₹7,128 | 488 ₹6,441.6 Lowest | 2,800 ₹36,960 |
| 6.00 | Providing and fixing sheet covering over expansion joints with iron screws as per design. Aluminium fluted strips 3.15 mm thick, 200 mm wide. | 264 | One Metre | 720 ₹1,90,080 | 563 ₹1,48,632 Lowest | 950 ₹2,50,800 |
| 7.00 | Reinforced cement concrete work in arches, archribs, domes, vaults, shells, folded plate and roofs having slope more than 15° up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) | 431 | cum | 7,650 ₹32,97,150 Lowest | 9,000 ₹38,79,000 | 11,000 ₹47,41,000 |
| 8.00 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 150mm dia pipe. | 96 | One running Metre | 72 ₹6,912 | 60 ₹5,760 Lowest | 400 ₹38,400 |
| 9.00 | 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc., complete | 4,296 | sqm | 900 ₹38,66,400 | 713 ₹30,63,048 | 700 ₹30,07,200 Lowest |
| 10.00 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-Charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment shall be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. | 633.6 | sqm | 300 ₹1,90,080 | 240 ₹1,52,064 Lowest | 250 ₹1,58,400 |
Tender Value
₹1.3 Cr
EMD Value
₹2.6 L
Closing Date
10 Mar 2026, 3:00 pmClosed
Dy.ChiefEngineer
WAPCOS Limited (A Government of India Undertaking) Project Office, MEPZ Special Economic Zone, GST Road, Tambaram Chennai 600 045 Telephone 044-4511 8383
Renovation Of Well-Knit Building at MEPZ- SEZ, Tambaram, Chennai - 600 045.
2026_MSEZA_898897_1
WAP/ENVT/MEPZ/2026/ET/01
Open Tender
Civil Works
Item Rate
MEPZ-SEZ, Tambaram
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,900
WAPCOS Limited
₹2.6 L
18 May 2026
17 Feb 2026
11 Mar 2026
17 Feb 2026
10 Mar 2026
3 Mar 2026
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles above 25 mm and up to 40 mm
Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineerin-charge
Disposal of building rubbish/malba/similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineerin-charge, beyond 50m initial lead, for all leads including all lifts involved
Providing and applying fibre reinforced elastomeric liquid waterproofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @ 10.76 litre/10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.
Providing and fixing in position 12mm thick bitumen impregnated fiber board conforming to IS: 1838, including cost of primer, sealing compound Grade-A in expansion joints.
Providing and fixing sheet covering over expansion joints with iron screws as per design. Aluminium fluted strips 3.15 mm thick, 200 mm wide.
Reinforced cement concrete work in arches, archribs, domes, vaults, shells, folded plate and roofs having slope more than 15° up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 150mm dia pipe.
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc., complete
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-Charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment shall be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
BOQ_944844.xls
BOQ • 1.14 MB
tenderdoc.pdf
Tender Documents • 1.46 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .