| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.9 LAccepted-AOC NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | ₹5.9 L Quoted ₹6.0 L | 1 | Accepted-AOC BeingL1 |
| 2 | 2₹6.3 L+₹29,393 (4.92%)Rejected-Finance | ₹6.3 L+₹29,393 (4.92%) | 2 | Rejected-Finance quoted amount is higher than 1st lowest |
| 3 | Rejected-Technical 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | - | - | Rejected-Technical Not enlisted in required category |
| 4 | Rejected-Technical E 37 CWE AF SOUTH BANGALORE A I A II B I | BENGALURU URBAN | KARNATAKA | 560001 | - | - | Rejected-Technical Not enlisted in required category |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not enlisted in required category |
Tender Value
Refer Docs
EMD Value
₹13,000
Closing Date
21 Feb 2024, 6:00 pmClosed
AGE I AF Coimbatore
AGE I AF COIMBATORE AFAC COMPLEX KAMARAJAR ROAD RED FIELD POST COIMBATORE PIN -641018
COMPREHENSIVE MAINTENANCE OF 48 HP VRF AIR CONDITIONING PLANT AT AFAC COIMBATORE.
2024_MES_639117_1
8962_E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Coimbatore
Class-E category-C (i) (see NIT for detail)
8 documents required · 8 mandatory
₹500
AGE I AF Coimbatore
₹13,000
Yes
29 Feb 2024
25 Jan 2024
26 Feb 2024
25 Jan 2024
21 Feb 2024
9 Feb 2024
25 Jan 2024 - 8 Feb 2024
Amount
Comprehensive maintenance ( once in a month ) of 48 HP VRF air conditioning system comprises of 3 Nos x 16 HP outdoor VRF unit and ceiling mounted indoor units 04 Nos x 8 TR, 01 No. x 6 TR and 01 No. x 4.5 TR including servicing/ cleaning of indoor/outdoor units, cleaning of Air filter and air outlet grills with a soft dry cloth, replacement of PVC drain pipe, checking and cleaning of inlet and outlet air tubing of indoor units of air conditioers, cleaning of condensing and cooling coils , (use a vacuum cleaner to remove dust from the air inlet), oiling to fan motor, cleaning of compressor etc, checking / replacement of air pipe thermal insulation, checking/dressing up of electrical wirings/ circuits etc wherever necessary to keep the air conditioner in good working condition all as specified and directed by the Engr-in-charge. Note: - (1) Minor spare parts such as grease, oil, cleaning materials, pipe insulation, nut, bolts, washers, etc required for repair/replacement shall deemed to be included in quoted rates and nothing shall be paid on this account. Note: - (2) All T&P required for maintenance at height upto 7 metre shall be provided by contractor and nothing shall be paid on this account. This item rate covers attending to any number of breakdown call and labour charge is included for fixing any spare for smooth funing of the plant.
Checking, cleaning, and adjusting of branch slector unit complete.
Checking, cleaning, and adjusting of control device system including local control system and central control system for cooling/heating operation of VRF AC Plant.
Checking, of mounting anti vibration base of outdoor unit.
Checking, and adjusting of air direction adjuster of outdoor unit.
Checking, cleaning aluminium extruded square diffuser and sitout damper.
Supply refrigerant gas R-410a including testing and charging complete all as specified and directed. ( Labour charges included under Item No. 1)
Supply only Tube Assembly discharge suitable for of 16 HP VRFOut door unit complete all as specified and directed. ( Labour charges included under Item No. 1)
Supply only TubeValve Reverse suitable for of 16 HP VRFOut door unit complete all as specified and directed. ( Labour charges included under Item No. 1)
Supply only Sensor Pressure suitable for of 16 HP VRFOut door unit complete all as specified and directed. ( Labour charges included under Item No. 1)
Supply only Tube Assembly Expansion suitable for of 16 HP VRFOut door unit complete all as specified and directed. ( Labour charges included under Item No. 1)
Supply only PCB assembly cycle suitable for of 16 HP VRFOut door unit complete all as specified and directed. ( Labour charges included under Item No. 1)
Supply only PCB assembly main /cycle suitable for of 16 HP VRFOut door unit complete all as specified and directed. ( Labour charges included under Item No. 1)
Supply only Accumulatore suitable for of 16 HP VRFOut door unit complete all as specified and directed. ( Labour charges included under Item No. 1)
Supply only PCB assembly filter suitable for of 16 HP VRFOut door unit complete all as specified and directed. ( Labour charges included under Item No. 1)
Supply only Case assembley control box of 16 HP VRFOut door unit complete all as specified and directed. ( Fixing included in item No. 1)
Supply & fixing of PCB Assembley Inverter suitable for 16 HP VRF indoor unit complete all as specified and directed. ( Fixing included in item No. 1)
Supply & fixing of Motor Assembley DC suitable for 16 HP VRF In door and out door Unit complete all as specified and directed. ( Fixing included in item No. 1)
Supply only Tube Assembly Suction suitable for of 16 HP VRFOut door unit complete all as specified and directed. ( Labour charges included under Item No. 1)
p.chinnasamy
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .