Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.8 LAccepted-AOC AT PLOT NO 92 BHAGABANPUR PATRAPADA BHUBANESWAR DIST KHURDA | BHUBANESWAR | KHURDA | ODISHA | 765017 | ₹41.8 L | L1 | Accepted-AOC First Lowest selected through transparent lottery System |
| 2 | L1₹41.8 LRejected-AOC PLOT NO 22 EKAMRAVILLA JAYADEV VIHAR IRCVILLAGE BHUBANESWAR | BHADRAK | ODISHA | 756121 | ₹41.8 L | L1 | Rejected-AOC First Lowest |
| 3 | L2₹44.2 L+₹2.4 L (5.75%)Rejected-AOC | ₹44.2 L+₹2.4 L (5.75%) | L2 | Rejected-AOC Second Lowest |
Tender Value
₹49.2 L
EMD Value
₹49,300
Closing Date
19 Dec 2025, 5:00 pmClosed
OFFICE OF THE SUPERINTENDING ENGINEER, RAYAGADA R
RAYAGADA R AND B DIVISION I, RAYAGADA SUPERINTENDING ENGINEER, RAYAGADA R AND B DIVISION I OFFICE OF THE SUPERINTENDING ENGINEER, RAYAGADA R AND B DIVISION I, RAYAGADA ODISHA 765001 RAYAGADA DISTRICT
Shifting of 11KV line from the Therubali grid to Bhatpur due to widening of Komtalpeta-Muniguda -Tumudibandha road (00/00 Km to 30/00 Km) from 2 lane to 4 Lane
2025_EICCL_122556_3
RC (RANDB) RGD 17 / 2025-2026
Open Tender
Electrical Works
Percentage
180 days
RAYAGADA R AND B DIVISION I, RAYAGADA SUPERINTENDI
Please refer Tender documents.
2 documents required · 2 mandatory
₹6,000
₹49,300
Yes
15 Jun 2026
10 Dec 2025
20 Dec 2025
10 Dec 2025
19 Dec 2025
10 Dec 2025
Shifting of 11KV line 11mtr long 160x152mm WPB pole
9Mtr long 300Kg PSC pole
11KV F clamp 2.9Kg each
11KV V cross arm(10.2Kg each)
Disc Insulator(T&C)45KN Polymer
Hard ware (T&C)45KN
11kV Pin Insulator Polymer
100x50x6mm GI channel for straight cross arm 1.2Mtr & 0.3Mtr (9.2Kg/Mtr)
Earthing coil
6SWG GI wire for earthing
RCC Base plate
55mmsq AAA Conductor
PG clamp for 55mm2 AAA conductor
G.I.Nuts & bolts of Assorated size
GI barbed wire (Anti climbing device @3Kg per support)
Back clamp for anticlinmbing device @3Kg per support
Back clamp for anticlimbing device 25x3mm flat,0.59Kg/Mtr flat of 0.510mtr length 4nos-(4x0.59x0.510)
Danger board
Back clamp for anticlimbing device 25x3mm flat,0.59Kg/Mtr flat of 0.510mtr length 1nos-(1x0.59x0.510)
75x40x6mm MS channel,1.5mtr long -1s 3m*4nos for providing support for guarding at 1No of road crossing
8SWG GI wire for crossing lacing 12Kg for each road crosing
40mm nominal bore G.I.pipe(Medium guage) Earthing Device with 3mtr long
GI flat (25x6)mm @1.2Kg/Mtr 1No.Earthing at both sides of road crossing guarding
Sundries(Pole Numbering,Zebra Painting, Binding wire etc)
Shifting of 11/0.4KV 150KVA 9Mttr long 300 KG PSC pole
Presure channel 100x50x6mm (2.8Mx2PC)(9.2Kg/Mtr)with Galvanizing
AB switch mounting channel (75x40x6)mm 2.8mr long 2nos (6.8Kg/Mtr)with Galvanizing
HG fuse mounting channel (75x40x6)mm 2.8mtr long 2nos.(6.8Kg/Mtr)with Galvanizing
Cantiliverr GI channel for supporting AB switch arm 75x40x6mm -1mtr long 2nos(@6.8Kg/Mtr)
Cantiliver Angle for supporting AB switch 50x50x6mm G.I.Angle (1)mtr long 2nos(6.8Kg/Mtr)
Angle for mounting LT distributiion box (50x50x6)mm (4.5Kg/Mtr)with galvanizing.
Disc Insulator(T&C)45KN Polymer
Hard ware (T&C)45KN
HT stay set complete
7/10 SWG GI stay wire,Grade-2
HT stay clamp(1.9Kg/Pair)
40mm nominal bore G.I.pipe(Medium guage) Earthing Device with 3mtr long
GI flat 25x6mm
Erection charges for 150 KVA 11/0.4 KV transformer
GI Nuts & Bolts of Assoried size
55sqmm AAA conductor for jumpering
1Cx185mmsq LT XLPE cable(armoured)
Earthing coil
6SWG GI wire
Danger board
Back clamp for danger plate 25x3mm flat,0.59Kg/Mtr flat for 0.51mtr alength 1nos=(1x59x0.510)
G.I.Barbed wire(Anti climbing device@3Kg per support)
Back clamp for anticlimbing device 25x3mm flat,0.59Kg/Mtr flat of 0.510mtr length 4nos-(4x0.59x0.510)
Sundries(Pole Numbering, Zebra Painting, Insulation tape etc)
Shifting of 11 KV Metering Unit DP Structure 9Mttr long 300 KG PSC pole
Presure channel 100x50x6mm (2.8Mx2PC)(9.2Kg/Mtr)
Earthing device/Support coil type(GI)
No.8 GI wire Dia 4.6mm 0.11Kg/Mtr each pole connnecting pole with Coil earthing
11kV Disc Insulator(B&S)45KN
11KV H/W fitting(B&S)
HT stay set complete
Sttay clamp
7/10 GI stay wire
G.I.pipe earthing 40mm dia medium guage 2.5mtr long
No.6 GI wire for earthing
Danger board
G.I.Barbed wire(Anti climbing device@3Kg per support)
GI Nuts & Bolts and washers
G.I.clamp for Danger board GI flat ([email protected]/Mtr)510mm length (0.306Kg/piece)
G.I. clamp for climbing device 25x3mm flat,0.6 Kg/Mtr flat of 0.510mtr length 4nos /Oike(1.22 Kg/Pole)
Sundries(Pole Numbering, Zebra Painting, Insulation tape etc)
Shifting of LT Poles 8 Mttr long 200 KG PSC pole
Pole clamp for I hook
Dead end clamp
Suspension clamp with I hook for ABC
GI Nuts & Bolts of Assoted size
LT stay set
LT stay clamp(1.40Kg/Pair)
7/12 SWG GI stay wire(Grade-2)
RCC Base plate for support
Earthing Device Coil type(GI)
CIVIL WORK Stay concreting to radio 1:2:4(0.5x0.5x0.8)mtr
Concreting of poles in radio 1:1:5:3(500mmx500mmx1800mm)=0.307Cu.mtr
Concreting of poles in radio 1:1:5:3(500mmx500mmx1800mm)=0.44Cu.mtr
couping of poles in radio 1:1:5:3(500x500x475)=0.11875Cu.mtr
Materials for earthing inclduing massonary work for earth pit and cement plate cover including salt,charcoal etc
Civil cost for TRF plingth from 250KVA of upto 1000KVA provide necessary civil material,manpower ,machinery for construction o f plingth as per standard drawing.
G.I.fencing with Gate
Dismentling of 9/8 PCC/Joist pole (Servicable pole)after digging the pit and taking out the pole,transportation and stacking the pole at a proper place in safe position within 10Km /site store andrefilling the pit with loose earth and ramming including removal and disposal of malba at proper location as per instruction of EIC.
Dismentling of Steel structure (Angle/Channel/Flat)and Nuts and Bolt including loading, Transportation, unloading and staking of dismentied material at a proper place in safe position/BA site store
Dismantle-34-55sqmm AAAC conductor
11KV Rodad Crossing Guarding 11mtr long 160x152mm WPB pole
11KV F clamp 2.9Kg each
11KV V cross arm(10.2Kg each)
G.I.Back clamp for V cross arm(11kV)0.85 each
11kV Pin Insulator Polymer
Earthing coil
6SWG GI wire for earthing
G.I.Nuts & bolts of Assorated size
GI barbed wire (Anti climbing device @3Kg per support)
Back clamp for anticlimbing device 25x3mm flat,0.59Kg/Mtr flat of 0.510mtr length 4nos-(4x0.59x0.510)
Danger board
75x40x6mm MS channel, Guarding-1s 3m*4nos for providing support for guarding at 1No of road crossing
8SWG GI wire for crossing lacing 12Kg for each road crossing
40mm nominal bore G.I.pipe (Medium guage)earthing device with 3Mtr long
Eye Hook
G.I.flat (25x6)mm @1.2Kg/Mtr 1No earthing at both side s of road crossing guarding.
Sundries(Pole Numbering,Zebra Painting,Binding wire etc)
LT line road crossing 9 Mttr long 200 KG PSC pole
Pole clamp for I hook
Dead end clamp
Eye hook for Dead end clamp
GI Nuts & Bolts of Assoted size
7/12 SWG GI stay wire(Grade-2)
RCC Base plate for support
Earthing Device Coil type(GI)
Sundries(Pole Numbering,Zebra Painting,Binding wire etc)
CIVIL WORK Concreting of poles in radio 1:1:5:3(500mmx500mmx1800mm)=0.307Cu.mtr
Concreting of poles in radio 1:1:5:3(500mmx500mmx1800mm)=0.44Cu.mtr
Coupling of poles in radio 1:1:5:3 (500x500x475)=0.11875 Cu.mtr
Dismentling of 9/8Mtr PCC/Joist pole (servicecable pole)after digging the pit and taking out the pole,transportation ans stacking the pole at a proper plate in safe position within 10km /site store and refilling the pit with loose earth and remaining including removal and sisposal of malba at proper location as per instruction of EIC.
Shifting of 11KV line 11mtr long 160x152mm WPB pole
9Mtr long 300Kg PSC pole
11KV F clamp 2.9Kg each
11KV V cross arm(10.2Kg each)
G.I.Back clamp for V cross arm(11kV)0.85 each
Disc Insulator (T&C)45KN Polymer
Hardware(T&C)45KN
11kV Pin Insulator Polymer
100x50x6mm GI chan nedl for straight cross arm 1.2Mtr & 0.3Mtr(9.2Kg/Mtr)
Earthing coil
6SWG GI wire for earthing
RCC base plate
55mmsq AAA conductor
PG clamp for 55mm2 AAA conductor
G.I.Nuts & bolts of Assorated size
GI barbed wire (Anti climbing device @3Kg per support)
Back clamp for anticlimbing device 25x3mm flat,0.59Kg/Mtr flat of 0.510mtr length 4nos-(4x0.59x0.510)
Danger board
Back clamp for anticlimbing device 25x3mm flat,0.59Kg/Mtr flat of 0.510mtr length 1nos-(1x0.59x0.510)
75x40x6mm MS channel, Guarding-1s 3m*4nos for providing support for guarding at 1No of road crossing
8SWG GI wire for crossing lacing 12Kg for each road crossing
40mm nominal bore G.I.pipe (Medium guage)earthing device with 3Mtr long
Eye hook
G.I.flat (25x6)mm @1.2Kg/Mtr 1No earthing at both side s of road crossing guarding.
Sundries(Pole Numbering,Zebra Painting,Binding wire etc)
Shifting of 11/0.23KV 16KVA S/S 9Mttr long 300 KG PSC pole
2Cx16sqmm PVC cable(Unarmoured)
HT stay set complete
11KV Stay Insulator
7/10 SWG GI stay wire
Stay clamp(1.95 Kg/Pair)
55mmm2 AAAC
G.I.pipe Earthing 40mm dia medium guage 2.5mtr long
Base plate for support
11KV Disc Insulator(B&S) Polymer
11KV H/W fittingh B&S (2 Bolted)type
Earthing Coil
6SWG GI wire
G.I.Barbed wire(Anti climbing device@3Kg per support
Back clamp for anti climbing device 25x3mm flat 0.59 Kg/Mtr flat of 0.510 Mtr length 4Nos-(4.0.59x0.510)
Danger plate
Back clamp for anti climbing device 25x3mm flat 0.59 Kg/Mtr flat of 0.510 Mtr length 1Nos-(1.0.59x0.510)
Sundries(Paint Allumin ium wire & tape,insulting tape sockets. clamp,connector and jumpering materials etc)
Shifting of LT poles 8 Mttr long 200 KG PSC pole
Pole clamp for I hook
Dead end clamp
Eye hook for Dead end clamp
Suspension clamp with I hook for ABC
GI Nuts & Bolts of Assoted size
LT stay set
LT stay insulator
LT stay clamp(1.40Kg/Pair)
7/12 SWG GI stay wire(Grade-2)
RCC Base plate for support
Earthing Device Coil type(GI)
6SWG GI wire
Sundries(Pole Numbering,Zebra Painting,Binding wire etc)
CIVIL WORK Stay concreting to radio 1:2:4(0.5x0.5x0.8)mtr
Concreting of poles in radio 1:1:5:3(500mmx500mmx1800mm)=0.307Cu.mtr
Concreting of poles in radio 1:1:5:3(500mmx500mmx1800mm)=0.44Cu.mtr
couping of poles in radio 1:1:5:3(500x500x475)=0.11875Cu.mtr
Materials for earthing inclduing massonary work for earth pit and cement plate cover including salt,charcoal etc
Dismentling of 9/8 PCC/Joist pole (Servicable pole)after digging the pit and taking out the pole,transportation and stacking the pole at a proper place in safe position within 10Km /site store andrefilling the pit with loose earth and ramming including removal and disposal of malba at proper location as per instruction of EIC.
Dismentled 34-55sqmm AAAC conductor
Shifting of 11KV line 11mtr long 160x152mm WPB pole
9Mtr long 300Kg PSC pole
Earthing coil
6SWG GI wire for earthing
RCC base plate
55mmsq AAA conductor
PG clamp for 55mm2 AAA conductor
G.I.Nuts & bolts of Assorated size
GI barbed wire (Anti climbing device @3Kg per support)
Back clamp for anticlimbing device 25x3mm flat,0.59Kg/Mtr flat of 0.510mtr length 4nos-(4x0.59x0.510)
Danger board
Back clamp for anticlimbing device 25x3mm flat,0.59Kg/Mtr flat of 0.510mtr length 1nos-(1x0.59x0.510)
75x40x6mm MS channel, Guarding-1s 3m*4nos for providing support for guarding at 1No of road crossing
8SWG GI wire for crossing lacing 12Kg for each road crossing
40mm nominal bore G.I.pipe (Medium guage)earthing device with 3Mtr long
Eye hook
G.I.flat (25x6)mm @1.2Kg/Mtr 1No earthing at both side s of road crossing guarding.
Sundries(Pole Numbering,Zebra Painting,Binding wire etc)
Shifting of 11/0.4KV 250KVA S/S 11mtr long 160x152mm WPB pole
AB switch (11KV,200A,3pole,50HZ)
HG fuse (11KV,200A,3pole)with PI
LA(9KV,10KA)Station class
Disc Insulator (T&C)45KN Polymer
Hardware(T&C)45KN
HT stay set complete
7/10 SWG GI stay wire,Grade-2
Stay insulator
HT stay clamp(1.9Kg/Pair)
40mm nominal bore G.I.pipe (Medium guage)earthing device with 3Mtr long
GI flat 25x6mm
250 KVA,11/0.4KVATransformer BIS Energy level-II
GI Nuts & Bolts of Assoted size
55sqmm AAA conductor for jumpering
1Cx185sqmm LT XLPE cable(armoured)
Earthing coil
6SWG GI wire
Danger board
Back clamp for anticlimbing device 25x3mm flat,0.59Kg/Mtr flat of 0.510mtr length 1nos-(1x0.59x0.510)
G.I barbed wire (Anti climbing device@3Kg per support)
Back clamp for anticlimbing device 25x3mm flat,0.59Kg/Mtr flat of 0.510mtr length 4nos-(4x0.59x0.510)
Sundries(Paint Allumin ium wire & tape,insulting tape sockets. clamp,connector and jumpering materials etc)
Shifting of LT poles 9 Mttr long 300 KG PSC pole
8Mtr long 200Kg PSC pole
pole clamp for clamp
Dead end clamp
Eye hook for Dead end clamp
Suspension clamp with I hook for ABC
GI Nuts & Bolts of Assoted size
LT stay set
LT stay Insulator
LT stay clamp(1.40Kg/Pair)
7/12 SWG GI stay wire,Grade-2
RCC base plate for support
Earthing Device Coil type(GI)
6SWG GI wire
Sundries(Pole Numbering,Zebra Painting,Binding wire etc)
CIVIL WORK
Concreting of poles in radio 1:1:5:3(500mmx500mmx1800mm)=0.307Cu.mtr
Concreting of poles in radio 1:1:5:3(500mmx500mmx1800mm)=0.44Cu.mtr
couping of poles in radio 1:1:5:3(500x500x475)=0.11875Cu.mtr
Materials for earthing inclduing massonary work for earth pit and cement plate cover including salt,charcoal etc
Civil cost for making TRF plinth from 250KVA of Dismentling of 9/8 PCC/Joist pole (Servicable pole)after digging the pit and taking out the pole,transportation and stacking the pole at a proper place in safe position within 10Km /site store andrefilling the pit with loose earth and ramming including removal and disposal of malba at proper location as per instruction of EIC.
Dismentling 55sqmm AAAC conductor
Dismentling of existing 11/0.4KV ,250 KVA Three phase Distribution Transformer including removalof HT/LT leads,earth connections and unloading by crane if required. Scope of work also includes loading,transportation,unloading and staking at proper place in safe position/site store.
Stay concreting to radio 1:2:4(0.5x0.5x0.8)mtr
11KV F clamp 2.9Kg each
11KV V cross arm(10.2Kg each)
G.I.back clamp for V cross arm(11kV)0.85 each
Disc insulator(T&C)45KN polymer
Hardware(T&C)45KN
11KV Pin Insulator Polymer
100x50x6mm G.I.channel for straight cross arm (including tapping point)
Earthing coil
6SWG GI wire for earthing
RCC Base plate
55mm2 AAA conductor
PG clamp for 55mmm2 AAA conductor
G.I.Nuts & bolts of Assorated size
GI Barbed wire(Anti climbing device@3Kg per support)
Back clamp for Danger plate 25x3mm flat (0.59Kg/Mtr)flat of 0.510 mtr length 4nos-(4x0.59x0.510)
Back clamp for Danger plate 25x3mm flat (0.59Kg/Mtr)flat of 0.510 mtr length 1nos-(1x0.59x0.510)
Sundries(Pole Zebra painting,Binding wire etc)
Shifting of 11kV line 9Mtr long 300KG PSC pole
pressure channal 100x50x6mm (2.8Mx2Pc)(0.9.2Kg/Mtr)with Galvanizing
A.B.switch mounting channel75x40x6mm (1.2mtr long 2nos 6.8Kg/Mtr)with Galvanizing
Cantilever GI channel for supporting AB switch arm,75x40x6-1mtr long 2Nos @6.8Kg/Mtr)
Cantilever angle for support ing AB switch 50x50x6mm G.I.Angle (1)mtr long [email protected]/Mtr)
AB switch side support channel 100x50x6mm 9.2Kg/Mtr eachg channel length 0.35Mtr,2nos channel required
AB switch 11KV,400A,3pole,50HZ)
LA(9KV,100A)station class
Disc insulator (T&C)45KN polymer
Hardware(T&C)45KN
HTstay set complete
Stay insulator
HT stay clamp(1.9Kg/Pair)
40mm nominalk bore G.I.pipe (Medium guage)earthing Device with 3mtr long
GI flat 25x6mm
G.I.Nuts and Bolts of Assorted size
Earthing coil
Earthing coil
6SWG GI wire
Danger board
Back clamp for anticlimbing device 25x3mm flat,0.59Kg/Mtr flat of 0.510mtr length 4nos-(4x0.59x0.510)
Sundries(Pole numbering,Zebra painting,Insulation tape etc)
Shifting of 11KV line DP Structure 11Mtr long 160x152mm WPB pole
pressure channal 100x50x6mm (2.8Mx2Pc)(0.9.2Kg/Mtr)with Galvanizing
Transformer mounting channel(100x50x6)mm 2.8Mtr long 2nos(9.2Kg/Mtr)with Galvanizing
AB switch mounting channel(75x40x6) mm 2.8 mtr long 2nos(6.8Kg/Mtr)with alvanizing
HG fuse mounting channel(75x40x6)mm 2.8mtr long 2nos(6.8Kg/Mtr)with Galvanizing
Cantiliver GI channel for supporting AB switch arm,75x40x6-1mtr [email protected]/Mtr)
Cantiliver GI channel for supporting AB switch arm,50x50x6-1mtr [email protected]/Mtr)
Angle for mounting LT distribution box (50x50x6)mm 4.5Kg/Mtr with Galvanizing
AB switch side support channel 100x50x6mm 9.2KG/Mtr each channel length 0.35mtr,2nos channel required.
Channel support for down pipe 75x40x6mm,6.8Kg/Mtr each channel length 0.8mtr,1no channel required.
Transformer belting angle (50x50x6)mm 3.5mtr long-2nos(4.5Kg/Mtr)with Galvanizing.
AB switch (11KV,200A,3pole,50HZ)
HG fuse(11kV,200A,3pole)with PI
LA(9KV,10KA)Station class
Disc insulator(T&C)45KN polymer
Hardware(T&C)45KN
HT stay set complete
7/10 SWG GI stay wire,Grade-2
Stay insulator
HT stay clamp(1.9Kg/Pair)
40mm nominal bore G.I.pipe(medium guage)Earthing device with 3mtr long
G.I.flat 25x6mm
Erection charge for 25KVA substation 11/0.4 kva
G.I.Nuts and Bolts of Assorted size
55sqmm AAA conductor for jumpering
Earthing coil
6SWG GI wire
Danger board
Back clamp for danger plate 25x3mm flat,0.59Kg/Mtr flat for 0.51mtr length 1nos= (1x59x0.510)
GI barbed wire(Anti climbing device@3Kg per support)
Back clamp for danger plate 25x3mm flat,0.59Kg/Mtr flat for 0.51mtr length 4nos= (4x59x0.510)
Sundries(Pole numbering,zebra painting insulation tap etc)
Shifting of 11/0.4KV 25KVA S/S 9Mtr long 300KG PSC pole
8mtr long 200Kg PSC pole
Pole clamp for I hook
Dead end clamp
Eye hook for dead end clamp
Suspension clamp with I hook for ABC
G.I.Nuts and Bolts of Assorted size
Lt stay set
LT stay insulator
LT stay clamp(1.40Kg/Pair)
7/12 SWG GI stay wire,Grade-2
RCC Base plate for support
Earthing device coil type(GI)
Sundries(Pole Zebra painting,Binding tape and other accessories etc)
Shifting of 1P2W AB cable 9 Mtr long 300KG PSC pole
Concreting of poles in radio 1:1:5:3(500mmx500mmx1800mm)=0.307cu.mtr
Concreting of poles in radio 1:1:5:3(500mmx500mmx1800mm)=0.44cu.mtr
couping of poles in radio 1:1:5:3(500x500x475)=0.11875Cu.mtr
Materials for earthing inclduing massonary work for earth pit and cement plate cover including salt,charcoal etc
GI fencing with Gate
Dismentling of 9/8Mtr PCC/Joist pole (servicecable pole)after digging the pit and taking out the pole,transportation ans stacking the pole at a proper plate in safe position within 10km /site store and refilling the pit with loose earth and remaining including removal and sisposal of malba at proper location as per instruction of EIC.
Dismentling 34-55sqmm AAAC conductor
Dismentling of 11KG/33KV GO/AB switch/Isolator/DD fuse/fuse set including removal of all Electric earth connections,loading,transportration ,unloadibng and staking at a proper place in safe position/BA site store(Note set=Three phase)
Dismentling of existing 11/0.4KV ,250 KVA Three phase Distribution Transformer including removalof HT/LT leads,earth connections and unloading by crane if required. Scope of work also includes loading,transportation,unloading and staking at proper place in safe position/site store.
CIVIL WORK Stay Concreting in radio 1:2:4(0.5x0.5x0.8).mtr
11KV F clamp 2.9Kg each
11KV V cross arm(10.2Kg each)
G.I.Back clamp for V cross arm(11kV)0.85 each
11kV Pin Insulator Polymer
Disc insulator(T&C)45KN polymer
Hardware(T&C)45KN
100x50x6mm GI channel for straight cross arm 1.2Mtr & 0.3Mtr(9.2Kg/Mtr
55mmsq AAA conductor
PG clamp for 55mm2 AAA conductor
Earthing coil
6SWG GI wire for earting
G.I.Nuts & bolts of Assorated size
GI barbed wire (Anti climbing device @3Kg per support)
Back clamp for anticlimbing device 25x3mm flat,0.59Kg/Mtr flat of 0.510mtr length 4nos-(4x0.59x0.510)
Danger board
Back clamp for anticlimbing device 25x3mm flat,0.59Kg/Mtr flat of 0.510mtr length 1nos-(1x0.59x0.510)
75x40x6mm MS channel, Guarding-1s 3m*4nos for providing support for guarding at 1No of road crossing
8SWG GI wire for crossing lacing 12Kg for each road crossing
40mm nominal bore G.I.pipe (Medium guage)earthing device with 3Mtr long
Eye hook
G.I.flat (25x6)mm @1.2Kg/Mtr 1No earthing at both side s of road crossing guarding.
Sundries(Pole Numbering,Zebra Painting,Binding wire etc)
11KV Road Crossing Guarding 11mtr long 160x152mm WPB pole
Pole clamp for I hook
Suspension clamp with I hook for ABC
GI Nuts & Bolts of Assoted size
RCC Base plate for support
Earthing Device Coil type(GI)
6SWG GI wire
Sundries(Pole,Zebra painting,Binding tape and othr accedssories etc)
LT line Road Crossing 9 Mtr long 300 KG PSC pole
Coupling of poles in radio 1:1:5:3 (500x500x475)=0.11875 Cu.mtr
Dismentling of 9/8Mtr PCC/Joist pole (servicecable pole)after digging the pit and taking out the pole,transportation ans stacking the pole at a proper plate in safe position within 10km /site store and refilling the pit with loose earth and remaining including removal and sisposal of malba at proper location as per instruction of EIC.
Dismentile-34-55sqmm AAAC conductor
CIVIL WORK Concreting of poles in radio 1:1:5:3(500mmx500mmx1800mm)=0.307Cu.mtr
9Mtr long 300KG PSC pole
Disc insulator(T&C)45KN polymer
Hardware(T&C)45KN
11KV Pin insulator polymer
100x50x6mm GI channel for straight cross arm 1,2Mtr & 0.3Mtr(9.2Kg/Mtr)
HT stay set complete
7/10 SWG GI stay wire,Grade-2
Stay insulator
HT stay clamp(1.9Kg/Pair)
Earthing coil
6SWG GI wire for earthing
RCC Base plate
55mm sq AAA conductor
PG clamp for 55mm2 AAA conductor
G.I.Nuts & bolts of Assorted size
G.I.Barbed wire (Anti climbing device@3Kg per support)
Back clamp for anticlimbing device 25x3mm flat,0.59Kg/Mtr flat of 0.510mtr length 4nos-(4x0.59x0.510)
Danger board
Back clamp for Danger plate 25x3mm flat (0.59Kg/Mtr)flat of 0.510 mtr length 1nos-(1x0.59x0.510)
75x40x6mm MS Channel 1,5mtr 4Nos for providing support Guarding at 1No road crossing.
8SWG GI wire for cross lacing 12Kg for each Road Crossing
40mm nominal bore G.I. pipe(Medium guage Earthing Device with 3mtr long
Eye hook
G.I.flat (25x6)[email protected]/Mtr 1No earthing at both sides of road crossing guarding.
Sundries(Pole Numbering,Zebra Painting,Binding wire etc)
Shifting of 11KV line 11Mtr long 160x152mm WPB pole
8Mtr long 200Kg PSC pole
Pole clamp for I hook
Dead end clamp
Eye hook for Dead end clamp
Suspension clamp wih I hook for ABC
G.I.Nuts & bolts of Assorted size
LT stay set
LT stay insulaor
LT stay clamp(1.4Kg/Pair
7/12 SWG GI stay wire(Grade-2)
RCC Base plate for support
Earthing Device coil type(GI)
6SWG GI wire
Sundries(Pole Numbering,Zebra Painting,Binding tape and other accessories etc)
Shifting of LT poles 9Mtr long 300KG PSC pole
Concreting of poles in radio 1:1:5:3(500mmx500mmx1800mm)=0.307cu.mtr
Concreting of poles in radio 1:1:5:3(500mmx500mmx1800mm)=0.44cu.mtr
couping of poles in radio 1:1:5:3(500x500x475)=0.11875Cu.mtr
Materials for earthing inclduing massonary work for earth pit and cement plate cover including salt,charcoal etc
Dismentling of 9/8Mtr PCC/Joist pole (servicecable pole)after digging the pit and taking out the pole,transportation ans stacking the pole at a proper plate in safe position within 10km /site store and refilling the pit with loose earth and remaining including removal and sisposal of malba at proper location as per instruction of EIC.
Dismentling 34-55sqmm AAAC conductor
CIVIL WORK Stay Concreting in radio 1:2:4(0.5x0.5x0.8).mtr
9Mtr long 300KG PSC pole
11KV F clamp 2.9Kg each
11KV V Cross arm(10.2Kg each)
G.I.Back clamp for V cross arm(11kV)0.85 each)
Disc insulator(T&C)45KN polymer
Hardware(T&C)45KN
11KV Pin insulator polymer
100x50x6mm GI channel for straight cross arm 1,2Mtr & 0.3Mtr(9.2Kg/Mtr)
Earthing coil
6SWG GI wire for earthing
RCC Base plate
55mm sq AAA conductor
PG clamp for 55mm2 AAA conductor
G.I.Nuts & bolts of Assorted size
G.I.Barbed wire (Anti climbing device@3Kg per support)
Back clamp for anticlimbing device 25x3mm flat,0.59Kg/Mtr flat of 0.510mtr length 4nos-(4x0.59x0.510)
Danger board
Back clamp for Danger plate 25x3mm flat (0.59Kg/Mtr)flat of 0.510 mtr length 1nos-(1x0.59x0.510)
75x40x6mm MS Channel 1,5mtr 4Nos for providing support Guarding at 1No road crossing.
8SWG GI wire for cross lacing 12Kg for each Road Crossing
40mm nominal bore G.I. pipe(Medium guage Earthing Device with 3mtr long
Eye hook
G.I.flat (25x6)[email protected]/Mtr 1No earthing at both sides of road crossing guarding.
Sundries(Pole Numbering,Zebra Painting,Binding wire etc)
Shifting of 11KV line 11Mtr long 160x152mm WPB pole
Pressure channel (110x50x6)mm 2.8mtr long 2nos (9,.2Kg/Mtr)with Galvanizing
AB switch mounting channel (75x40x6)mm 2.8mtgr long 2nos (6.8Kg/Mtr)with Galvanizing
Cantiliver GI channel for supporting AB switch arm,75x40x6-1mtr long [email protected]/Mtr
Cantiliver angle for supporting AB switch 50x50x6,GI angle (1)mtr long [email protected]/Mtr)
AB switch mounting channel (100x50x6)mm 9.2Kg /Mtr each channel length 0.35Mtr,2nos channel required
AB switch (11Kv,400A,3pole,50HZ)
LA(9KV,10KA)Station class
Disc insulator (T&C)40KN Polymer
Hard ware(T&C)45KN
HT stay set complete
7/10 SWG GI stay wire,Grade-2
Stay insualtor
Ht stay clamp (19Kg/Pair)
40mm nominal bore G.I.pipe medium guage Earthing Device with 3mtr long
G.I.flat 25x6mm
G.I.Nuts & bolts of Assorted size
Earthing coil
6SWG GI wire
Danger board
Back clamp for anticlimbing device 25x3mm flat,0.59Kg/Mtr flat of 0.510mtr length 1nos-(1x0.59x0.510)
G.I.Barbed wire (Anti climbing device@3Kg per support)
Back clamp for anticlimbing device 25x3mm flat,0.59Kg/Mtr flat of 0.510mtr length 4nos-(4x0.59x0.510)
Sundries(Pole Numbering,Zebra Painting,Binding wire etc)
shifting of 11KV line AB Switch with DP structure 11Mtr long 160x152 mm WPB pole
Pressure channel(100x50x6)mm 2.8mtr long 2Nos(9.2Kg/Mtr)with Galvanizing
Transformer Mounting Channel(100x50x6)mm 2.8Mtr long 2Nos(9.2Kg/Mtr)with Galavanizing
AB switch mounting channel(75x40x6)mm 2.8mtr long 2nos(6.8Kg/Mtr)with Galanizing
HG fuse mounting channel (75x40x6)mm 2.8Mtr long 2nos(6.8Kg/Mtr)with Galvanizing
Cantilever GI channel for supporting AB Switch arm,75x40x6.1Mtr long,[email protected]/Mtr)
Cantiliver Angle for mounting supporting AB switch (50x50x6)mmG.I.Angle (1)mtr long 2nos)@4.5Kg/Mtr)
Angle for mounting LT distribution box (50x50x6)mm(4.5Kg/Mtr)with Galvanizing
AB switch side support channel100x50x6mm 9.2Kg/Mtr each channel length 0,.35Mtr,2nos channel required
Channel support for down pipe 75x40x6mm 6.8Kg/Mtr each channel length 0.8Mtr,1no channel required
Transformer belting angle (50x50x6)mm 3.5Mtr long 2nos(4.5Kg/Mtr)with Galvanizing
AB switch (11KV,200A,3pole-50HZ)
HG fuse(11KV,200A,3pole)wth PI
LA(9KV,10KA)Station class
Disc insulator (T&C)40KN Polymer
Hard ware(T&C)45KN
HT stay set complete
7/10 SWG GI stay wire,Grade-2
Stay insualtor
Ht stay clamp (19Kg/Pair)
40mm nominal bore G.I.pipe medium guage Earthing Device with 3mtr long
GI flat 25x6mm
LT Distribution box with MCCB Alluminium busbar of single Bay with kit kat fuse for 25KVA S/S
GI Nuts & Bolts of Assoted size
55sqmm AAA conductor for jumpering
1Cx70sqmm LT XLPE cable(armoured)
Earthing coil
6SWG GI wire
Danger board
Back clamp for anticlimbing device 25x3mm flat,0.59Kg/Mtr flat of 0.510mtr length 1nos-(1x0.59x0.510)
G.I barbed wire (Anti climbing device@3Kg per support)
Back clamp for anticlimbing device 25x3mm flat,0.59Kg/Mtr flat of 0.510mtr length 4nos-(4x0.59x0.510)
Sundries(Paint Allumin ium wire & tape,insulting tape sockets. clamp,connector and jumpering materials etc)
Shifting of 11/0.4KV,25KVA S/S-1No(9mtr PSC pole DP) 9Mtr long 300KG PSC pole
Pressure channel(100x50x6)mm 2.8mtr long 2Nos(9.2Kg/Mtr)with Galvanizing
Transformer Mounting Channel(100x50x6)mm 2.8Mtr long 2Nos(9.2Kg/Mtr)with Galavanizing
AB switch mounting channel(75x40x6)mm 2.8mtr long 2nos(6.8Kg/Mtr)with Galanizing
HG fuse mounting channel (75x40x6)mm 2.8Mtr long 2nos(6.8Kg/Mtr)with Galvanizing
Cantilever GI channel for supporting AB Switch arm,75x40x6.1Mtr long,[email protected]/Mtr)
Cantiliver Angle for mounting supporting AB switch (50x50x6)mmG.I.Angle (1)mtr long 2nos)@4.5Kg/Mtr)
Angle for mounting LT distribution box (50x50x6)mm(4.5Kg/Mtr)with Galvanizing
AB switch side support channel100x50x6mm 9.2Kg/Mtr each channel length 0,.35Mtr,2nos channel required
Channel support for down pipe 75x40x6mm 6.8Kg/Mtr each channel length 0.8Mtr,1no channel required
Transformer belting angle (50x50x6)mm 3.5Mtr long 2nos(4.5Kg/Mtr)with Galvanizing
AB switch (11KV,200A,3pole-50HZ)
HG fuse(11KV,200A,3pole)wth PI
LA(9KV,10KA)Station class
Disc insulator (T&C)45KN Polymer
Hard ware(T&C)45KN
HT stay set complete
7/10 SWG GI stay wire,Grade-2
Stay insualtor
Ht stay clamp (19Kg/Pair)
40mm nominal bore G.I.pipe medium guage Earthing Device with 3mtr long
G.I.flat 25x6mm
Erection charge for 25KVA substation 11/0.4 kva
LT Distribution box with MCCB Alluminium busbar of single Bay with kit kat fuse for 63KVA S/S
GI Nuts & Bolts of Assoted size
55sqmm AAA conductor for jumpering
1Cx70sqmm LT XLPE cable(armoured)
Earthing coil
6SWG GI wire
Danger board
Back clamp for anticlimbing device 25x3mm flat,0.59Kg/Mtr flat of 0.510mtr length 1nos-(1x0.59x0.510)
G.I.Barbed wire (Anti climbing device@3Kg per support)
Back clamp for anticlimbing device 25x3mm flat,0.59Kg/Mtr flat of 0.510mtr length 4nos-(4x0.59x0.510)
Sundries(Pole Numbering,Zebra Painting,Binding tape and other accessories etc)
Shifting of 11/0.4KV 63KVA S/S -1No(9Mtr PSC pole DP)pole mounted 9Mtr long 300KG PSC pole
G.I.Nuts and Bolts of Assorted size
Lt stay set
LT stay insulator
LT stay clamp(1/40Kg/Pair)
7/12 SWG GI stay wire,Grade-2
RCC Base plate for support
Earthing Device Coil type(GI)
6SWG GI wire
Sundries(Pole Zebra painting,Binding tape and other accessories etc)
Shifting of LT poles 9 Mtr long 300KG PSC pole
Concreting of poles in radio 1:1:5:3(500mmx500mmx1800mm)=0.307cu.mtr
Concreting of poles in radio 1:1:5:3(500mmx500mmx1800mm)=0.44cu.mtr
couping of poles in radio 1:1:5:3(500x500x475)=0.11875Cu.mtr
Materials for earthing inclduing massonary work for earth pit and cement plate cover including salt,charcoal etc
GI fencing with Gate
Dismentling of 9/8Mtr PCC/Joist pole (servicecable pole)after digging the pit and taking out the pole,transportation ans stacking the pole at a proper plate in safe position within 10km /site store and refilling the pit with loose earth and remaining including removal and sisposal of malba at proper location as per instruction of EIC.
Dismentling 34-55sqmm AAAC conductor
Dismentling of existing 11/0.4KV, Three phase Distributiion Transformer 63KVA including removal of HT/LT leads,earth connections and unloading by crane required.Scope of work also iincludes loading, transportation, unloadingand staking at a proper place in safe postion/site store
Dismentling of existing 11/0.4KV,33/0.4KV, ,25KVA Three phase Distribution Transformer including removalof HT/LT leads,earth connections and unloading by crane if required. Scope of work also includes loading,transportation,unloading and staking at proper place in safe position/site store.
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.PDF
finance_569387.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.77 MB
DTCN_shifting_Therubali.pdf
Tender Documents • 0.68 MB
BOQ_569387.xls
BOQ • 1.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .