AGE(I) Zakhama
C/o 792 FPO PIN-900792 C/O 99 APO
REPAIR REPLACEMENT OF CONVENTIONAL TYPE CEILING LIGHTS LED CEILING LIGHTS WALL LAMPS ETC AT ZONE AAT ZAKHAMA MIL STN
2021_MES_465343_3
8991 CONVENTIONAL CEILING ZONE A ZAK
Open Tender
Civil Works
Item Rate
180 days
AGE(I) Zakhama
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
AGE (I) Zakhama
₹19,000
Yes
14 Feb 2022
8 Dec 2021
31 Dec 2021
8 Dec 2021
28 Dec 2021
15 Dec 2021
60 days
Amount
Taking down carefully any type of point wiring (light, fan, bell, socket or power), complete excluding fittings but including switches, ceiling roses, pendants, regulators, sockets, etc. and making good disturbed surfaces of walls, ceiling, floors etc to match with existing surface complete all as specified and as directed.
M&L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathed FRLS cable, 1100 volts grade IS-694 marked, with multistranded copper conductors and earth continuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly) laid/fixed with and including PVC Casing and Caping on walls/ceiling, and with PVC switch board for mounting switches/socket etc for one light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and as directed.
All as per item serial No 02 here-in-before but for One 3 pin 5 Amp switch socket outlet on independent board.
All as per item serial No 02 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cable and earth continuity wire with 2.5 Sqmm cable for 6 pin 15 Amp socket outlet on independent board.
S & F switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed.
S & F switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type complete all as specified and as directed.
S&F in repairs, switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type complete all as specified and as directed.
S & F switch socket combination, multipurpose, 2 in 1, 6 pin, 5 & 15 Amp flush type complete all as specified and as directed.
S&F in repairs, switch socket combination, multipurpose, 2 in 1, 6 pin, 5 & 15 Amp flush type complete all as specified and as directed.
S&F in repairs, PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mmthick plastic laminated sheet cover of size 250 mm x 150 mm and 50 mm deep complete all as specified and as directed.
S&F in repairs, PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mmthick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and as directed.
S&F in repairs, 34 watt LED recessed mounted luminaire with high brightness SMD LEDs as light source, suitable for Armstrong/Grid ceiling and fixture size in mm (LxWxH) 595x595x70mm complete all as specified and as directed. Make : Havells Model-PLUTONEO2x2PLR34WLED840S/ PLUTONEO2x2PLR34WLED857S or equivalent model in make of Philips/ Crompton/Bajaj
S&F in repairs, 42 watt LED recessed mounted luminaire with high brightness SMD LEDs as light source, suitable for Armstrong/Grid ceiling and fixture size in mm (LxWxH) 595x595x70mm complete all as specified and as directed. Havells Model-PLUTONEO2X2PLR42WLED857S/ PLUTONEO2X2PLR42WLED840S or equivalent model in make of Philips/ Crompton/Bajaj
S & F in repairs, sheet metal enclosure when MCB to be used 2 way, Single pole & neutral without bus bar complete all as specified and asdirected..
S&F in repairs, single pole & neutral DBs 4 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar complete all as specified and as directed. Make :- Legrand Cat No 5076 10 or equivalent model in Siemens / Schneider/L&T
S & F in repairs, single pole & neutral DBs 8 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar complete all as specified and as directed. Make :- Legrand Cat No 5076 11 or equivalent model in Siemens / Schneider
S&F MCB SPN 40 to 63Amps, 415V,50 HZ,C series breaking capacity 10KA complete all as specified and as directed. Make- Legrand ,cat part no-4086 18 to 20 equivalent model of make Siemens/Schnider.
S&F MCBs, SPN 6 to 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. Make :- Legrand Model 4086 09 to 17 or equivalent model in Siemens / Schneider/L&T
S&F MCBs, SP 6 to 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. Make :- Legrand Model 4085 90 to 95 orequivalent model in Siemens / Schneider/L&T
S&F RCBOs, double pole ,30mA, 10 to 25 Amps for earth leakage ,overload & short-circuit protection complete all as specified and as directed.
M&L for Sub main wiring with 2 runs of 6.0 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dia non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. (Note: 2 run of 6 Sqmm cable and 1 run of 6 Sqmm cable along with conduit altogether shall be measured as one unit.)
S&F in repairs 1100 volts grade heavy duty flat cable of size 6 Sqmm 2 core, PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including replacing 4mm suspension wire complete all as specified and as directed.
S&F in repairs 1100 volts grade heavy duty flat cable of size 10 Sqmm 2 core, PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including replacing 4mm suspension wire complete all as specified and as directed.
S&F in repairs 1100 volts grade heavy duty flat cable of size 16 Sqmm 2 core, PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including replacing 4mm suspension wire complete all as specified and as directed.
J C DUTTA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .