THE COMMISSIONER
Salem City Muncipal Corporation, Fort Main Road, Salem
Arrangements of Assistant Executive Engineer Office Room at Hasthampatty Ward Office
2023_MAWS_323085_1
E3-Est No 453-B-2022-2023
Open Tender
Civil Works
Lump-sum
30 days
SALEM CITY MUNICIPAL CORPORATION
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹6,500
Yes
21 Jun 2023
5 Jun 2023
21 Jun 2023
5 Jun 2023
21 Jun 2023
5 Jun 2023
Amount
Dismantling the existing damaged Brick work in cement morter including all cost, conveyance of materials and all labour charges etc., complete and as per s.s.
Chipping the existing damaged Plastered Surface inlcuding all labour charges etc., complete
Brick work in cement mortar 1:5 mix using Fly Ash bricks of 230x110x70mm (8 3/4" x 41/4" x 23/4") from approved quarry including cost and conveyance of all materials to site. Loading and unloading charges and labour charges for mixing, laying and curing etc. complete.
b). First Floor
Supplying and fixing MS grill to doors windows and ventilators etc. as directed by the departmental officers inclusive of cost of MS grill and labour charges including one coat of red oxide and fixing in position etc. complete
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 25GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with spag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown olour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames.
Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections.Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug.
Special Ceiling Plastering for RCC slabs and beams with cement mortar 1:3 mix 10mm thick including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing etc. complete . complying with std. specifications
Plastering with cement mortar 1:5 mix, 12mm thick including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing etc. complete . complying with std. specifications
Supplying and fixing the Wall Panelling with the following specification fixing horizontally and vertically in position of wall. Fixing the water proof ply wood 9mm thick board over the country wood planks. Over the ply wood OST sheet of 4mm thick will be fixed with necessary screws and fevicol giving neat finish. The top will be finished with two coats of sanding polishing. The surface will be finished with necessary design as directed by the Departmental Officers. The rate inclusive of all materials, labour power and conveyance of materials to the work site, loading & unloading etc., and as per drawing and design by the Departmental Officers. The water proof ply wood and OST sheet and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard specification.
Supply and Fixing of Vnyl Floor Matt of 1.5mm thick including all cost and conveyance etc., complete.
Providing suspended Hilux Board False Ceiling of the following types with G.I. perimeter channel of size 0.55mm tk (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling , screw fixed to brick wall/ partition with the help of nylon sleeves and screws at 610mm centres. Then suspending G.I. Intermediate channel of size 45mm (0.90mm thick with two flanges of 15mm each) from the soffit at 1200mm centres with ceiling angle of 25mmx 10mmx0.50mm thick fixed to soffit with G.I Cleat and steel expansion fastners ceiling section of 0.50mm thickness having knurled web of 51.50mm and two flanges of 26mm each with lips of10.50mm are then fixed to the intermediate channel at 457mm centres. 12.50mm tapered edge Gyp board (confirming to is 2095-1982) is then screw fixed to ceiling section with25mm dry wall screws at 230mm centres. Screw fixing should bedone mechanically either with screw driver or with drilling machine with suitable attachment got approved by the Executive Engineer before use on works in etc., complete complying with standard specification.
Supply and Fixing of PVC Imported Wall Paper including all cost and conveyance etc., complete.
Supply and Fixing of ornamental Vision Bicids for Window Openings including all cost and conveyance etc., complete.
Providing Cup-board Shutter with frame using termite / water proof plywood of 19mm thick over which laminated sheet of 0.8mm thick fixed inside the shutter and 1mm thick fixed in the outside of the shutter using fevicol along with necessary furniture fittings, such as, hydralic hinges, tower bolt, handles, multi purpose locks etc., as directed by the Departmental Officers. The design pattern, water proof plywood, laminate sheet and other materials should be got approved from the Executive Engineer befoe use on work.
Painting two coats with ready mixed Plastic Emulsion Paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. - 10 sq.m
Wiring with 2 x 1.5 sqmm (22 / 0.3) PVC insulated SC unsheathedCu. Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T switch with continuous earth wire connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for PVC concealed light point / Fan point (For electronic regulator). (SD-23)
Wiring with 2x1.5sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with 150 x l00 x for open PVC plug point.inter locking CS plug with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for PVC Plug Point (SD-36)
Wiring with 2x4 sqmm(56/0.3) PVC insulated SC unsheathed Cu.Conductor cable of 1100V grade in suitable pipe on wall and ceiling with PVC accessories with 150 mm x 100 mm x 63mm TW switch box for 15 A 3 pin non inter locking CS plug with painting of suitable colour, with continuous earth wire connection of 14 SWG TC wire for open PVC power plug point. (SD-39)
Supply and fixing of 20Amps DP Plug and Socket in sheet enclosure with 32A DP MCB in flush with wall with earth connection (For AC Plug) [Legrand (MDS) / Hager (L&T) make] (SD-140)
Supply and and Fixing of 18W LED 3000K Square Type Recessed Fitting with LED including all cost and conveyance etc., complete.
Supply and installation of 5 KVA capacity Automatic Voltage Stabilizer with time delay relay
Supply of Spit Type Air Conditions fitted with Hermetically sales composers operations refrigerant A-22 Non CFC sup table for floor mounting, wall mounting and Ceiling Mountings conforming to IS 1391 (part Consumption on 230V, 50 Hz single phase) Ac supply capable of performing cooling, Dehumidifying, Air Conditions, Filtering 2Ton (4500K cal / Hr) (GI Sheet/Abs, Hips Plastic) complete. (1 Ton Capacity)
SWETHALAKSHMI ENGINEERING
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .