Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.0 CrAccepted-AOC | ₹11.0 Cr | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹11.2 CrRejected-Finance | ₹11.2 Cr | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹11.5 CrRejected-Finance WZ 487 2 MS BLOCK HARI NAGAR NEW DELHI 110064 | NEW DELHI | NEW DELHI | DELHI | 110064 | ₹11.5 Cr | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹11.5 CrRejected-Finance | ₹11.5 Cr | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹12.3 CrRejected-Finance | ₹12.3 Cr | L5 | Rejected-Finance Not being L1 |
Tender Value
₹10.4 Cr
EMD Value
₹8.5 L
Closing Date
10 May 2024, 6:00 pmClosed
Chief Engineer AF Bangalore
Chief Engineer AF Bangalore No. 2 DC Area MES Road Yeshwantpur Post Bangalore 560022
PROVISION OF CERTAIN DEFICIENT OMQS AT GAGAN VIHAR CAMP AT BANGALORE
2024_MES_643866_1
801581/E8
Open Tender
Civil Works
540 days
GE (AF) Marathahalli
As per NIT
8 documents required · 8 mandatory
₹3,000
Yes
GE (AF) Marathahalli
₹8.5 L
Yes
22 May 2024
23 Feb 2024
13 May 2024
23 Feb 2024
10 May 2024
26 Apr 2024
24 Feb 2024 - 29 Feb 2024
Amount
BOQ Dated 22 Apr 2024
GENERAL SUMMARY NOTE: Schedule ‘A’ Part I to XIV are prepriced by MES under Ser No. 1 to 14. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the contractor for “ BUILDING WORKS” as listed in Schedule ‘A’ Part–I
Lumpsum price worked out by the contractor for “SITE CLEARANCE AND DEVELOPMENT WORKS ” as listed in Schedule ‘A’ Part - II
Lumpsum price worked out by the contractor for “INTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part–III
Lumpsum price worked out by the contractor for “INTERNAL ELECTRIC SUPPLY” as listed in Schedule ‘A’ Part - IV.
Lumpsum price worked out by the contractor for “ROAD/PATH/HARDSTANDING/CULVERT” as listed in Schedule ‘A’ Part – V.
Lumpsum price worked out by the contractor for "SEWAGE DISPOSAL" as listed in Schedule ‘A’ Part VI.
Lumpsum price worked out by the contractor for "AREA DRAINAGE" as listed in Schedule ‘A’ Part VII.
Lumpsum price worked out by the contractor for “COMPOUND WALL AND GATE” as listed in Schedule ‘A’ Part – VIII.
Lumpsum price worked out by the contractor for “LIGHTENING PROTECTION” as listed in Schedule ‘A’ Part – IX.
Lumpsum price worked out by the contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part – X.
Lumpsum price worked out by the contractor for “EXTERNAL ELECTRIC SUPPLY)” as listed in Schedule ‘A’ Part – XI.
Lumpsum price worked out by the contractor for "DG SETS" as listed in Schedule ‘A’ Part XII.
Lumpsum price worked out by the contractor for "FIRE ALARM SYSTEM” as listed in Schedule ‘A’ Part – XIII.
Lumpsum price worked out by the contractor for ““LIFT” as listed in Schedule ‘A’ Part – XIV.
Sch 'A' Part - XV: ITEM RATE TO BE QUOTED BY THE CONTRACTOR Internal WATER SUPPLY Supply and fixing Sink cock with swinging casted round shape spout (Wall mounted model) with connected legs and wall flanges 15 mm bore dia, quarter turn complete all as specified and directed
Supply and fixing CP brass Angular stop cock 15 mm dia, quarter turn with wall flange Make - Jaquar Clarion Model No CQT-23059 or equivalent in Kohler, Marc, Cera
Supply and fixing CP brass Bib cock 15 mm dia, Make - Jaquar Clarion Model No Model No CQT-23037 or equivalent in Kohler, Marc, Cera
Supply and fixing CP brass 2 way Bib cock 15 mm dia, Make - Jaquar Clarion Model No Model No CQT-23041 or equivalent in Kohler, Marc, Cera
Supply and fixing CP brass Shower Wall mixer 15mm with 115mm long bend pipe on upper side Make – Jaquar Clarion Model No CQT-23243UPR or equivalent in Kohler, Marc, Cera
Supply and fixing of CP brass central hole basin mixer without pop up waste system 15mm Make: Jaquar Clarion Model No CQT-23169B or equivalent in Kohler, Marc, Cera
Supply and fixing Health faucet with flexible pipe ( ABS body ) with 01 meter long flexible tube in chrome finish and wall hook Make Jaquar Clarion Model No ALD-579 or equivalent in Kohler, Marc, Cera
Supply and fixing Over head Shower 150x150mm Square shape single flor (ABS body chrome plated with gray face plate) Make – Jaquar Model OHS-35495 or equivalent in Kohler, Marc, Cera
INTERNAL ELECTRIC SUPPLY Supply and fix Wall mounting fan, 400 mm sweep, 70 CMM, power consumption 50 W all as specified and directed .
Supply and fix Modular TV Socket, one module all as specified and directed
Supply and fix Modular Telephone socket, RJ-11, one module all as spefied and directed
Material and labour for Telephone Wiring with unarmoured Solid annealed bare copper industrial cable in concealed of size 0.5 mm ,3 pair with PVC Conduit 25 mm dia all as specified and directed by engineer in charge .
Material and labour for TV Wiring with unarmoured coaxial cable,RG-11 in concealed with PVC Conduit 25 mm dia all as specified and directed
Material and labour for Mild steel Box for Telephone wiring including blocks , Suitable for 35 Pair all as specified and directed
Supply and fix Electric Chimney of size 60 CM ,Air suction capacity 1000 TO 1200 cubic mtr /Hr , filterless and dry heat automatic clean technology , Air pipe of size 150 mm dia all as specified and directed by engineer in charge .
Material and labour for Aluminium ducting pipe of 150 mm dia all as specified and directed by engineer in charge including making nessary size hole in wall finishing to match with the sorrundings .
EXTERNAL WATER SUPPLY Supply and fixing horizontal well submersible pump set suitable for 415V 3 Phase of capacity 5 HP Pump work etc (1 No working + 1 No Stand by) with suction and delivery pipe 50 mm x 40 mm, Head 36 mtr head, 440 LPM complete all as specified and directed by Engr -in-Charge
Supply and fix control panel out door weather proof including Automatic Star Delta Starter 3Phase 415V of cap 20 Amp, indicators, RYB single phasing preventor etc IP65 protection all as specified and directed by Engr-in-Charge
Material and labour in replacement of DI pipe class K-9 of size 100 mm dia with socket and spigot ends centrifugally cast (spun)with cement mortar lining inside the pipe and zinc coated outside with blue epoxy coating as per IS 8329/2000 in available lengths suitable for push on tyton joints (rubber gasket D jointing) laid in trenches complete all as specified and as directed.
Material and labour for Construction of new valve chamber of size 900x900x900mm with foundation cement concret brick / bricks in cement mortar 1:6 , with PCC 1:4:8 type D2 sub base plaster internally and exposed external surface in cement mortar 1:4 (15 mm thick and provision of valve chamber cover made out of MS sheet 3.0 mm thick welded on angle iron frames 40 x 40 x 5 mm made out of double door type with hinges and locking arrangement duly painted with 2 coat of synthetic enamel paint over a coat of red oxide primer all as directed complete with good finishing..
Supply and fixing of Chemical dozing system suitable to inject solution up to 25 LPH comprising dozing pump coupled with three phase electric motor of capacity 0.5 HP ,1440 RPM assembly with agitator in one motor agitator with SS sweep blade duly FRP coated FRP tank 150 Ltrs capacity
EXTERNAL ELECTRIC SUPPLY Supply and Installation of 11 KV Compact Sub Station with non extensible RMU consisting of 1 No manually operated 11 KV/630 Amps VCB in SF6 insulated stainless enclosure,HT Cable/Bus bar ,1 No Transformer 160 KVA,11KV/433 CRT associated LT devices(ACB/MCCB/bus bar/Cable). Note:- The transformer in CSS shall be as per IS 1180(Part I of 2014 energy efficient) Level-3
The 11 KV UNIPACK Package Sub-Station Shall be consisting of following, (A) HT SWITCHGEAR (i) 11KV 630Amps 21KA for 3 Sec, SF6 insulated Non-Extensible Compact switchgear (DV) consisting of One No. Direct module as incoming and One No. Fixed Manual Vacuum Circuit Braker as outgoing with Microprocessor based self Powered Relay in SF6 insulated stainless steel enclosure, with series trip, self powered microprocessor based numerical over current relay (IDMTL +Inst.) protection. Interconnection between HT switchgear and transformer shall be using 03 Nos single core x 95 Sq.mm Aluminum armored XLPE Cable (ii) Self Powered Numerical Non-communicable O/C & E/F Relay - 01 No (iii) CT-40/1A, CL-5P10, Burden - 2.5VA for Protection – 03 Nos (iv) Manometer - 01 No”
(B) (i) TRANSFORMER 160 KVA 11KV/433V 50Hz DYn11 Oil Filled Hermetically sealed transformer with corrugated wail and without conservator type design & Top normal porcelain bushing for HT and LT with Off load tap switch of range +5% to -5 % insteps of 2.5%. Temp rise over an ambient temp of 50Deg C-shall be 40/50 Deg C for Oil/winding resp. Insulation Class A, Losses (Subject to IS1180 Level 3) Max Losses at 50% Loading : 513 Watts and Max Losses at 100% Loading: 1547 Watts, Impedance shall be 4.5%. - 01 No (ii) Oil Temperature Indicator with alarm and trip contact - 01 No (iii) Winding Temperature Indicator with alarm and trip contact - 01 No” NOTES : (i) The bidder shall furnish dimensional drawings of the items offered indicating all the fittings, dimensional tolerances, typical GADs of the windings with details of insulation at each point and core construction, etc. For approval. (ii) Contractor shall submit the technical drawing, Constructional drawings, safety features drawing etc for approval all as directed by Engr-in-Charge. (iii) The CSS offered shall be type tested for IAC AB 21kA-1sec as per IEC 62271-202 . OEM shall submit Type test report for verification of the same. (iv) CSS offered by System house / Franchise partner/Joint venture partner of OEM shall not be accepted. CSS design; invoicing, ownership, service responsibility & warranty shall be of OEM on whose name all type tests are conducted. (v) Make of CSS, RMU, Vacuum bottle, VCB, ACB/MCCB Shall be of same manufacturer for better reliability, performance & service support and overall life cycle optimization. (vi) Oil type transformer makes shall be as per CSS manufacturer & CSS manufacturer shall send list of supply reference with offered transformer make (vii) The Temperature class of CSS shall be K10 as per IEC 62271-202
(C) (i) LVS PANEL-400AMPS ALUMINIUM BUSBAR (100% for Phase and 50% for neutral) Current Density for AI-1amp/Sqmm, fabrication of CRCA 1.5/2mm sheet. (ii) INCOMER FROM TRANSFORMER - 400Amps 433V 4P 50Hz 50KA Fixed manual Type Moulded Case Circuit Breaker (MCCB) with Thermal Magnetic based release for Overload and magnetic short circuit protection.- 01 No (ii) R,Y,B ON-OFF-TRIP Indication
Outgoings (i) 250 Amps 433V 3P 50 Hz 50 KA fixed manual type moulded case circuit breaker (MCCB) with thermal magnetic based release for overload and magnetic short circuit protection. (Make - ABB India Ltd) - 01 No (ii) 100Amps 433V 3P 50Hz 25KA Fixed manual Type Moulded Case Circuit Breaker (MCCB) with Thermal magnetic based release for Overload and magnetic short circuit protection. (Make: ABB India Limited) - 04 No (iii) 63Amps 433V 3P 50Hz 16KA Fixed manual Type Moulded Case Circuit Breaker (MCCB) with Thermal magnetic based release for Overload and magnetic short circuit protection. - 01 No
APFC PANEL (60KVAR) 60 KVAR Automatic power factor correction panel in 6 steps (10 KVAR x 6 ) consisting of follwing :- (i) 160Amps 433V 3P 36KA Manual Fixed Type Moulded Case Circuit Breaker (MCCB) with Thermal mangetic based release for over current and magnetic short circuit as incomer to APFC Panel (Make : ABB India Ltd) - 01 No (ii) APFC RVC Relay for 6 steps - 01 No (iii) “(iii) The following KVAR capacity metallized polypropylene capacitor bank as follows:_- (a) 1 KVAR X 1 No (b) 2 KVAR X 2 Nos (c) 5 KVAR X 2 Nos (d) 10 KVAR X 2 Nos (e) 25 KVAR X 1 No ” (iv) Capacitor duty contactor for switching on & switching off 60 KVAR bank (v) 32Amps 433V 3P 10KA Miniature Circuit Breaker for 60KVAR capacitor protection. (vi) FAN for heat discipiation & cooling of capacitor bank - 01 No D. OUTDOOR ENCLOSURE - Outdoor type enclosure having construction of Galvanised sheet Steel of combination 1.5/2mm with 4mm HRCA baseframe. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for Transformer compartment. The enclosure shall be Powder Coated (Colour Light Gray & D.A. Gray). Each comparment will be providec with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for MV & LV compartment. Seperate Switch Operated bulket lamp + Hooter in Transformer compartment - 01 Set
E. INTERCONNECTION AND EARTHING - Interconnection Between HT switchgear & Transformer using 1Cx3X95 Sq.mmXLPE Single core cable & Interconnection between Transformer & LT switchgear using Aluminium Busbars. Internal earthing connections by using 50 x 6mm GI strips - 01 Set Notes :- (i) Pacage Sub-station will be complete with the internal interconnections & earthing. Accessoies required for the external connections of HT & LT cables like termination kits, lugs, glands etc & extending of earth bar to earth pits are not in ABB India Limited scope.
Supply installation testing and commissioning of 12 KV 630 A, 3 phase 21KA SF6 insulation 50 Hz outdoor type(IP54) extendable manually operated LBS feeder 1 incoming and 2 outgoing Ring Main Unit with Aluminum busbar ( 1 LBS incommer + 2 VCB out going) RMUall as directed and specified.
Supply, install, testing & commissioning LT panel board, factory made cubicle totally enclosed outdoor type, CPRI approved, IP-65, fabricated out of 3 mm thick CRCA sheet with angle iron base frame made front side opening single door cover incl provision of cable glands of suitable sizes for incoming/outgoing cables, two coats of synthetic enamell smoke grey colour paint over a coat of red oxide, inside and outside,aluminium bus bar of rating 400 Amps for phase and half for neutral, mounted on epoxy insulator in parallel, covered with super quality PVC insulator tube of red, yellow, blue and black, pre-wired with suitable size of PVC insulated 1100 volts FR HR grade copper conductor, single core, multi stranded , comprising of the following incl necessary pcc work without DG Set (a) MCCB 250 amps 4 pole,36 KA,415 V - 01 No (incomming ) (b) MCCB 63 amps ,Adjustable type 4p pole,36 KA,415 V with neutral link - 13 No ( out going 12+1(spare) (c) MCCB 40 amps ,Adjustable type 4 pole,36 KA,415 V - 02No (Out going) (d) MCB16- 32A TPN amps ,Adjustable type 4 pole,36 KA,415 V - 02No (Out going Fire Alarm) (e) pre wired meter module with voltmeter ,Ammete,selctor switch cts control fuse & indicating lights- (f) RYB indicators - 01 set (g) Aluminium bus Bar 400 Amps 4 Way with colour code red yellow,blue and black. Assembly -01 nos
ROAD/PATH/HARDSTANDING/CULVERT Supply and fixing Solar panel mono crystalline solar 2.4V/0.3W cat eye's dual directional reflective cat eye of aluminium casted stud 125 X 100 x 25mm having aluminium alloy + PC body containing LED Battery NI-MH or NI-CD rechargable battery colour red side provided with steel zinc plastered nail or dia 12 mm and length 120mm by hammering complete all as specified and directed.. Make : Greenlite/Gogia plastic/Green
Material and labour for Delinator (steel) having acrylic reflector dual due directinal delineator having 100 mm dia cube corner high indensity reflector (red/yellow/White) holded in strong plastic ABS body mounted over CRC steel tube 50mm dia of 16 gauge sheet support of total height 600mm having flared/welded mesh cage. All steel parts stove enameled and baked to 120 degree C to make all weather resistance vertical support tube to have a plastic sheet reflector all around 100mm width, delineator to be fixed with screw and rowel plug in PCC 1:2:4 type B-1 block of size (20x20x30cm) CAT Part No 11-01 DELINEATOR ST-AC Make : Dark Eye/Greenlite/Gagla Plastics.
Supply and fixing of two way road studs of plastic body relfective panel amber/red/white 100x100x20mm fixed with screw or installed with epoxy adhesive on the road surface. Make : Dark Eye/Greenlite/Gagla Plastics.
Material and labour for excavation in trenches of 100mm depth and getting out hard/dense soil and Laying of concrete kerb stone of roughly squared stones of size 45cm x 35cm x 15cm, dressed so that the maximum depression from a straight edge held against the dressed surface shall not exceed 6mm for top and exposed surfaces of sides and 20mm for the rest of surfaces jointed in cement mortar 1:6 and struck flush over 50mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation and all as specified and directed
DG SET:- Supply , installed and commissioning of Factory assembled Silent DG set with CPCB approved acoustic enclosure AMF panel of capacity 62.5 KVA , 50 KW , 1500 RPM , Turbo Charged, water cooled comprising of suitable BHP Engine with microprocessor based Genset controller with silencer and canopy for soundles mode (sound level not exe level specified by contol pollution board) and alternator both mounted on a common base frame conforming to ISO-3046/BS-5514 and IS-10002 rated for 415 volts 50 cycles , 0.8 Power factor (PF) complete with residential silencer, AVM pads , battery with its leads, first fill of lub oil and all engine accessories such as self starter, alternator/dynomo with suitable coupling and base frame on foundation as recommended by the manufacture and consisting of other electrical component and maintenance free battey including suitable size of coppeer cable lead with teminal, all mounting accssory and AVM pads all as specifiedand directed.
A. Engine (a) Vertical multicylinder, cold starting in accordance with BS-5514/IS-10002 at 1500 RPM including the following accessories :- (i) Fuel tank(Suitable for capacity for minimum 12 Hrs run). (ii) Fuel filter(Ore & Micro). (iii) Fuel feed pump(Inline monoblock/PT type) with governor. (iv) Lub oil filter. (v) Lub oil cooler. (vi) Dry type/ol bah type air cleaner. (vii) Exhaust Silencer(Industrial type). (viii) Radiator, Radiator fan & mounting. (ix) Fly wheel with starting ring. (x) Expansion bellow. (xi) Exhaust gas turbocharger. (xii) 12 Volt electric starter with 01 Nos maintenance free battery of suitable capacity. (xiii) Battery charging alternator (xiv) Engine control panel consisting with ON/OFF Start Key,Lub oil pressure guage, Battery charging ammeter,Coolant temp gauge, RPM Meter etc. (xv) Suitable flexible coupling (xvi) Front & Rear engine mounting supports (AVM pads) B. ALTERNATOR (i) Alternator, 3 phase, 415 Volts, 50 Hzs 0.8 PF 1500 RPM self excited, self regulated screen profected, drip proof alternator of capacity 62.5 KVA conforming to BSS 5000 (part 99) with insulation class "H", single bearing and automatic voltage regulator accessories C. ACOUSTIC ENCLOSURE (i) Specially design to meet stringent MOEF/CPCB norms of 75 dBA @ 1 mtr at 75% load under free field conditions. (ii) Air inlet louvers specially designed to operate at rated load even at 50 deg C air inlet temp. (iii) Powder coated for long lasting service life and superior finish. (iv) Insulation material meets exacting IS 8183.
D. ACCESSORIES (i) Suitable channel frame (ii) Storage battery of suitable capacity as per manufactures instruction mounted on angle iron froame of suitable size as directed. E. CONTROL PANEL (a) The control panel shall be made of CRCA sheet duly fabricated and powder coated and complete with internal wiring, bus bar etc and fitted with the following accessories :- (i) 4 poie MCCB 100 Amps 25KA capacity – 01 No (ii) 3 Phase Multifunction meter – 01 No (iii) Indicating lamps (LED type) (R-Y-B) – 01 set F. AMF PANEL (a) The control panel shall be made of CRCA sheet duly fabricated and powder coated and complete with internal wiring, bus bar etc and fitted with the following accessories :- (i) 4 Pole MCCB 100 Amps, 25ka capacity – 01 No (ii) Contractor -03 Nos (iii) 3 Phase Multifunction meter – 01 No (iv) Indicating lamps (LED type) (R-Y-B) – 01 sets (v) Relay, timmer and other acessories as per manufactor. NOTE (i) Antivibraton mounting pads to be incorported during installation. (ii) PCC Foundation and platform as per manufacters design/recommendation to be followed during installation of DG Set will be measured and paid under relevant item of this BoQ. (iii) Silencer pipe of engine is to be extended out of the building with suitable dia of GI medium grade pipe duly heat insulated with suitable aluminum cladding rate of which deemed include in the the unit rate of Gen Set. (iv) Lubricating oil shall be provided by the conractor cost of which deemed to be included in the unit rate of DG Set. (v) Four Nos free serviceing with complete material such as Lubricating oil, coolent, Lub oil filter, diesel filters, Air filter and fan belts etc as per manufacturer recommendation will be deemed included in the unit rate of DG set.
LIFT Design supply, install testing & commissioning 08 (EIGHT) passenger capacity lift, speed 1.5 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS-14665, suitable to serve G+06 upper floors with AC Variable Voltage &Variable Frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors automatic rescue device(ARD) system, 3D infra red sensor in full height of door & built inannouncing system without hand set (04 Nos,one each in car, Machine room & near Ground floorlanding door) complete all as specified.
Supply, Installation, Testing & Commissioning of Active Repeater Panel (Remote Control Panel) with white backlit (240x64) graphical LCD display, incorporates function buttons for Silence, Mute, Resound, Reset and Disable/Enable, flash memory and advanced graphical display allows it to be easily configured to operate in virtually any language, with any character set and allows for the installer’s logo and corripany details to be displayed on the LCD display during normal operation. Networked for system display and control, in-built fault-tolerant network card to network with compatible addressable panel(s) and repeater panel(s), fully on-site programmable via alphanumeric keypad or configuration software, panel housing meets min IP30 ingress protection
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 2.5 sq mm, 2 core, 1100 Volts grade.
Supply and fix hose reel of 20 mm dia and 30 meter length conforming to IS 5132 and hose reel arrangement shall confirming to IS 884.
Supply and fix Addressable escape Exit Signage lighting visible from 20 mtrs (Approved as per BS EN 60598-2-2 by LIA laboratories ltd) with integral battery capacity of 3 hrs and bicoloured LED status indicator. Available in Left, Right, Down signs with Batteries incorporated into each luminaire shall be Polymer Lithium Ion technology and incorporate over voltage, over current and deep discharge protection circuitry. Provides at least 3 hours luminaire operation when fully charged
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electrical control cable(Heavy Duty) with stranded copper conductor in metal conduit pipe of size 1.5 Sqmm 2 core complete all as specified and directed
Supply and fix 100 mm dia pressure sensing valve
SMART METER Design ,Supply, installation, integration testing and commissioning of smart meters with pre-paid metering facility, AC three phase , four wire, 415 volts, 50Hz, 10 to 60 Amps all as per BIS 16444:2015 (Reaffirmed 2020) with plug-in type bi-directional communication Module (The plug-In Module shall be field swappable / replaceable) suitable for integration with approved communication technology GPRS / RF / Hybrid(GPRS+RF) / any other advanced technology as per CEA / TRAI regulations etc. easily adaptable for network interface and integration with Advanced Metering Infrastructure(AMI) complete in all respect all as specified and as directed by Engineer in charge. Note for smart meter:- Supply / planning / setup / tuning of RF communication infrastructure including Network Management(NMS) & Head End System(HES) for the project area. AMI software and associated equipments should be capable of handling atleast number of meters of different makes as per BIS 16444 with 25% expansion without any additional infrastructure and cost implication to MES. Note:- The defect liability period for SMART METER will be 2 years from the date of completion
Provision for comprehensive operation including periodic charges of telecom operator, smart meter billing from completion of work till the completion of defect liability period of 2 years
UNITED TECHNO PROJECTS PVT LTD
M/S Shiv Shakti Enterprises
Sri Lakshmi Constructions
C R R CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid