CWE Jaipur
HQ CWE Jaipur, Kalyan Marg, Jaipur
REPAIR AND MAINT OF HT 11 KV AND 33 KV NETWORK INCLUDING MAINT SPEED BREAKERS PANEL RMUS VCBS AND OTHERS ACCESSORIES AT ZONE-II AND HQ SWC UNDER GE (S) JAIPUR
2022_MES_555118_1
CWE/JPR(S)/82177/E8
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
GE (S) Jaipur
Enlisted with MES in Class E and above and category b(ii)
7 documents required · 7 mandatory
₹500
Yes
GE (S) Jaipur
₹40,000
Yes
2 Dec 2022
29 Sept 2022
3 Nov 2022
29 Sept 2022
1 Nov 2022
18 Oct 2022
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc or for shafts, wells, cess pits, manholes, pier holes, laying cables erection of poles / struts/stays etc not exceeding 10 Sqm on plan, not exceeding 1.5 metre in depth and getting out in any type of soil complete all as specified and directed.
M&L for sand cushioning to PVC underground cable with tibba sand and punning to provide a required cover complete all as specified and directed. Note:- Punned thickness shall be considered for payment purpose
Supplying and laying un-reinforced precast cable covers class HV, type I, peak, size 300mm x 180mm x 40mm complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in any type of soil complete all as specified and directed.
Removing of excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50metre above the starting point complete all as specified and directed
S&F in repair of Disc type insulator, Porcelain, vitreous brown, white or green single disc assembly, 145mm high & 255mm dia ball & socket type, for tension clamps for conductors, working pressure 11000 volts complete all as specified and directed
S&F in repair of pin type, porcelain, vitreous brown, white or green insulator (HT), 150mm height and 150 mm dia, 11000 volts grade including one galvanised MS spindle, two GI washers and one GI nut complete all as specified and directed
S&F in repair post insulator with GI post for holding fixed/moving contact assembly suitable for Air break gang operated switch 200 Amps, 11000 volts grade complete all as specified and directed
S&F in repairs lightening arrestor expulsion type complete with all fittings transmission class discharge capacity 65 KA suitable for 11000 volts complete all as specified and directed
Supply, installing, testing and commissioning of Air break, gang operated, triple pole switch 200 Amp rating complete with fuse carriers and HT fuse elements., outdoor, horizontal / vertical mounting type (ISI marked), mechanically operated, mounted on insulators and frame work with operating mechanism worked from ground level with locking arrangements including Godrej pattern 65mm pad locks with two keys, complete suitable for HT 11 KV, 50 Hz AC supply including necessary electric connections including taking down old unserviceable items complete all as specified and directed
S&F in repair of metallic (brass/alloy steel) fixed contact set single pole including fixing screwed nuts and washers suitable for air break gang operated switch of cap 200/400 amp 3 pole 11000 volts grade complete all as specified and directed
S&F in repair of metallic (brass/ alloy steel) moving contact set single pole including screws, nuts and washers suitable for air break gang operated switch of capacity 200/400 Amp 11000 volts including taking down complete all as specified and directed
S&F in repair of flexible copper straps including fixing screws, nuts and washers suitable for air break gang operated switch 200/400 amps 11000 volts for single phase complete all as specified and directed
M&L for shifting of trolley mounted transformer of any capacity any location within the station to location of defective transformer and connecting to HT cable 11000 volt in coming from existing source and LT outgoing cables complete all as specified and directed NOTE: T&P required for loading, unloading, shifting transporting the trolley mounted transformer back to E/M yard is deemed to be inclusive of the quoted rate.
M&L for disconnecting of defective transformer (indoor/outdoor type) 11KV/433 volts copper/ Aluminium wound from power mains and dismantling the same from 2/4 pole structure/ platform mounted and transporting the same to authorised workshop and opening the transformer cover, draining out of transformer oil and keep safely for reuse after filtration, assembling, removing of the burnt parts ie tape, paper insulating strings etc gently and carefully, washing of the dust, rust and dirt from all parts including taking out HT/LT leg coil core tank and cooling tubes, painting the inner side tank by zinc chromate paint and preparing the same for re-assembling after carrying out required repair and installation on existing 2/4 pole structure/ platform with necessary fixing arrangement including connecting up electrically, commissioning and testing all as directed by Engineer-in-Charge and specified in particular specification of the following capacity :-
(a) 63 KVA to 125 KVA capacity
(b) 150 KVA to 250 KVA capacity
(c) 315 KVA to 400 KVA capacity
(d) 500 KVA to 630 KVA capacity
NOTE for item No 15.01 to 15.03 (i) Repair cost is deemed to be included in the quoted rate; and Unserviceable items required to be replaced shall be measured and paid separately. (ii) The burnt transformer oil shall be contractor property & any new oil shall be measured and paid separately under respective item. (iii) The coils and the oil shall be inspected for repair/replacement by department rep.
Supply only HT/LT coil with suitable insulation for aluminium wound transformer of any type / capacity complete all as specified and directed.
Supply only HT coil with suitable insulation for copper wound transformer of any type / capacity complete all as specified and directed.
Supply only HT porcelain bushing complete with brass/tinned copper rod with nuts and gasket set complete all as specified and directed for following capacity transformer :-
(a) 63 KVA to 125 KVA capacity
(b) 150 KVA to 250 KVA capacity
(c) 315 KVA to 400 KVA capacity
(d) 500 KVA to 630 KVA capacity
Supply only LT porcelain bushing complete with brass/tinned copper rod with nuts and gasket set complete all as specified and directed for following capacity transformer :-
(a) 63 KVA to 125 KVA capacity
(b) 150 KVA to 250 KVA capacity
(c) 315 KVA to 400 KVA capacity
(d) 500 KVA to 630 KVA capacity
S&F breather with silica gel in replacement (for transformer of any type/cap) with end fitting complete all as specified and directed
M&L PCC (1:3:6), type C-1, using 20mm graded stone aggregate for pedestal of poles etc including form work, fair finished to exposed surfaces using extra cement complete all as specified and directed.
M&L for preparation of old surfaces, removing, cleaning of oil, grease etc. and painting with two coats of synthetic enamel paint of grey colour by spray complete all as specified and directed of following capacity transformer :-
(a) 63 KVA to 125 KVA capacity
(b) 150 KVA to 250 KVA capacity
(c) 315 KVA to 400 KVA capacity
(d) 500 KVA to 630 KVA capacity
M&L for refilling fresh Silica Gel into the breather including removal of unserviceable item complete all as specified and directed.
M&L for boring of existing road/path for laying of GI pipe size 100mm dia protection for UG cable including making good disturbed area/surface complete all as specified and directed.
Supply & fixing or laying in repair galvanised steel tubing light grade 100mm bore (ISI marked) for protection of underground cable on poles / walls under road crossing etc complete all as specified and directed.
M&L for calibration and setting of protection relay of any make or type fitted on 33 KV breakers, transformer Buchholz relay control panel at MRS (details given below) as per IS and code of practice to ensure NO ERROR including setting for each fault over current with trip time delay in accordance to feeder load and other parameters of site including synchronizing of the same with JVVNL/MRS setting to insure that fault shall not be travel to nearest source feeder including minor repair, replacement of wiring etc, if required complete all as specified and directed. (a) Incoming 33KV breaker :- 02 Nos (b) 33/11 KV, 2.5 MVA transformer relay control panel -02 Nos (HQ SWC Jaipur)
M&L for calibration and setting of protection relays of any make fitted on 11 KV VCBs (details given below) as per IS and code of practice to ensure NO ERROR including setting for each fault over current with trip time delay in accordance to feeder load and other parameters of site including synchronizing of the same with MRS setting to ensure that fault shall not travel to nearest source feeder including minor repairs, replacement of wiring etc, if required complete all as specified and directed (a) Incoming VCB 11 KV- 02 Nos(HQ SWC MRS) (b) Outgoing VCB 11 KV- 08 Nos(HQ SWC MRS) (c) Incoming VCB 11 KV- 02 Nos(Gothic Line) (d) Outgoing VCB 11 KV- 02 Nos(Gothic Line)
NOTE FOR ITEM NO. 26 to 27 (i) The calibration and setting must be completed within 30 days from the date of commencement to avoid any major break down. (ii) The calibration and setting shall be carried out by only qualified and experienced engineer. (iii) The relay setting shall be carried out once in a three month as per load and site conditions to avoid and any fault travel to next adjacent source breaker and shall be monitored regularly. (iv) For payment purpose the payment for calibration & setting of relay twice in 06 months is considered as each job. The cost of monitoring is also included in the item rate.
Disconnecting of HT supply from 33 KV VCB/SF 6 CB with panel capacity of 1250 Amp outdoor type for overhauling of mechanism and carry out repair works, servicing complete with decarburizing the contact points, cleaning with CRC solution etc testing after repair complete all as specified and directed
Disconnecting of HT supply from 11 KV VCB of capacity upto 800 Amps for overhauling of mechanism trolly and carry out repair works, servicing complete with decarburizing the contact points, cleaning with CRC solution etc testing after repair complete all as specified and directed. Make :- VCB AREVA/ALSTOM/CG Note:- Parts replaced of VCB shall be measured and paid separately under respective items.
Replacement of following parts for Srl item Nos 29 & 30 above :-
(a) Supply only Motor Cut off switch suitable for 11 KV VCB Make: Areva, Schneider/CG
(b) Supply only Ratchet wheel assembly suitable for 33 KV VCB Make: Areva, Schneider/CG.
(c) Supply only Shunt Trip Coil, operating voltage 24 Volts DC suitable for 11 KV VCB/ SF6 gas breaker. Make :CG, Areva, Schneider/CG.
(d) S & F Ratchet Pin.
(e) Supply only Push Rod
(f) Supply only Closing coil, operating voltage 24 Volt DC suitable for 11KV VCB/SF-6 gas breaker. Make: AREVA/ CG/Schneider.
(h) Supply only tripping coil assembly suitable for 11 KV, VCB/SF-6 gas breaker. Make: AREVA/CG/Schneider.
(i) Supply only small gear Assembly with motor shaft suitable for 11 KV VCB Make: AREVA/CG/Schneider.
(j) Supply only big gear suitable for 11 KV VCB. Make : CG/Areva/Schneider
(k) Supply only trip catch assembly suitable for 11KV VCB. Make- CG/Areva/Schneider
(l) Supply only hold on catch assembly suitable for 11KV VCB. Make- CG/Areva/Schneider.
(m) Supply only tripping shaft assembly suitable for 11 KV VCB. Make CG/Areva/Schneider
(n) Supply only closing shaft assembly suitable for 11 KV VCB. Make CG/Areva/Schneider
(o) Supply only TNC switch suitable for 11 KV VCB Make- CG/Areva/Schneider
(p) Supply only ZZ switch suitable for 11 KV VCB Make- CG/Areva/Schneider
Taking shut down and earthing the system carry out repair to off load rotating type 33KV/200 Amp Air break gang operated switch and alignment of isolators, blades, arcing horns moving mechanism oiling greasing to isolators tightening renewal/ replacement of unserviceable spare/components, nut and bolts complete after carrying out fresh lubrication using Lithium base grease/petroleum jelly, and re-fixing the spare parts/components complete all as specified and directed. Note: New spare/components shall be measured and paid separately as supply here-in-after and labour component deemed to be included in the quoted rate of this item.
Replacement of following parts for Srl item Nos 32 above :-
(a) Supply of metallic (brass, alloy) fixed contact set single pole including fixing screw nuts and washers suitable for air break gang operated switch of cap 200 amp 3 pole 33000 volts grade complete all as specified and directed.
(b) Supply of post insulator with GI post for holding fixed/moving contact assembly including fixing arrangement suitable for Air break gang operated switch 200 Amps 33000 volts grade complete all as specified and directed.
(c) Supply of metallic (brass, alloy) GOD conductor/cable connector clamp with nuts, bolts and washers suitable for 33 KV grade panther ACSR conductor complete all as specified and directed
(d) Supply & Fix GOD operating rod with cover 33000 Volts grade insulation including locking arrangement with 65mm pad lock (Godrej) with two keys complete all as specified and directed
(e) Supply & Fix HT fuse 30 to 200 amps capacity complete all as specified and directed
Supply, installation & testing of Microprocessor based three phase relay system for overcorrect, earth fault protection type MICOM/CGI 14N Model for 11 KV breaker, setting range with necessary wiring/fitting including dismantling of old IDMTL/Unserviceable relays complete all as specified and directed
S&F of Hooter system operating voltage 24V/220V AC/DC for 4 Nos VCB parallel operating system complete with testing including all accessories such as contactor, re-set switch and cut- out complete wiring etc including taking down old unserviceable, complete all as specified and directed
S&F of HRC fuse (link type) having capacity 2 to 6 amp, 415 V, 80 KA. complete all as specified and directed
S&F of PT fuse 3.15 Amp suitable for 11 KV VCB complete all as specified and directed
S&F of stud type terminals of 24V, DC suitable for 11KV VCB complete all as specified and directed
S&F of Resin based insulator suitable for existing 11 KV Breaker complete all as specified and directed
Disconnecting of HT supply from 11 KV VCB of capacity upto 800 Amps for rewiring of VCB control circuit with copper conductor wire size not less than 1.0 sqmm and after wiring testing complete all as specified and directed. Make of VCB AREVA/ ALSTOM
M&L in replacement of spring charge motor assembly with Gear Assembly operating voltage 220 V AC/ DC suitable for 11 KV VCB of Areva /CG complete all as specified and directed. Make of VCB AREVA/ ALSTOM
Supply & fixing HT Jumper not more than 2 Metres long in repair/replacement on existing OH circuit/two Pole/four Pole Structure etc including ACSR Conductor (Weasel) using PG clamp /lugs, fasteners etc complete all as specified and directed.
S & F epoxy based cast resin CT having ratio 200/150/100/05 or suitable size for 11 Kv as per site complete all as specified and directed.
Supply and Fixing in replacement LED/Neon indicator Lamps with holder size 22.5mm of different colour (24 V/220 V, AC/DC).
Supply & filling of transformer oil in transformer installed in situ at site for toping up the level of oil having dielectric strength 60-80 KV during filling after initial filtration conforming to IS-335 complete all as specified and directed. MAKE- POWER / INSOLE / UNIVERSAL / SAVITA NOTE: Transformer oil shall be supplied in sealed container and empty barrel of transformer oil will be deposited by contractor in E/M store yard.
M&L earthing complete as per electrical plate No 3 of MES SSR Part-I with galvanised steel earth plate electrode 600 mmx600mmx6mm, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level connected to and including galvanised iron or steel earth strip 25mm x 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 40 mm bore light grade and connected to continuous earth wire on pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover complete all as specified & tested complete. NOTE:- (i) The concrete pit shall be made in PCC 1:2:4 type B-O, using 12.00 mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover. Reinforcement in cover shall be of 8mm dia TMT bars laid @150mm c/c both ways. (ii) Quoted shall include the cost of 7.5 metre GI pipe for protection of earth wire/strip. (iii) Quoted shall include cost of 7.5 metre earth lead wire. (iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides.
Supply & Fixing Poly-floor insulating rubber mat suitable for 11 KV substation of size 2mtr x 1mtr x 3mm thick ISI mark complete all as specified and directed.
M&L for Dehydration /filtration of transformer oil existing transformer installed at site with portable plant to improve the dielectric strength 60 KV including testing of dielectric strength after dehydration and filtration at site complete all as specified and directed. NOTE: Pre-heated oil shall be topped up as required at site before the process; oil will be measured and paid separately under respective item.
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed
Supply, laying and commissioning XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 11000 volts grade IS-7098 marked, suitable for HT 11 KV (E) System laid in trenches/ ducts/ encased in GI pipe/ fixed to poles including jointing & testing complete all as specified and directed of following cross sectional area :-
(a) 95 Sqmm, 3 core cable
(b) 185 Sqmm, 3 core cable
M&L for cable end termination, jointing kit, HT 11 KV grade, heat shrinkable, outdoor type complete with jointing material suitable for HT XLPE cable 3 core 11 KV grade complete all as specified and directed of following sizes :-
(a) 95 Sqmm, 3 core cable
(b) 120 to 185 Sqmm x 3 core
M&L for cable straight through, jointing kit, HT 11 KV grade, heat shrinkable, outdoor type complete with jointing material suitable for HT XLPE cable 3 core 11 KV grade complete all as specified and directed of following sizes :-
(a) 95 Sqmm, 3 core cable
(b) 120 to 185 Sqmm x 3 core
M&L for cable end termination, jointing kit, HT 11 KV grade, heat shrinkable, indoor type complete with jointing material suitable for HT XLPE cable 3 core 11 KV grade complete all as specified and directed of following sizes:-
(a) 95 Sqmm, 3 core cable
(b) 120 to 185 Sqmm x 3 core
M&L for cable end termination, jointing kit, HT 33 KV grade, heat shrinkable, outdoor type complete with jointing material suitable for HT XLPE cable 3 core 33 KV grade for cable size 150 sqmm 3 core complete all as specified and directed.
M&L for cable, jointing kit, HT 33 KV grade, heat shrinkable, straight through type complete with jointing material suitable for HT XLPE cable 3 core 33 KV grade for cable size 150 sqmm 3 core complete all as specified and directed.
Supply, fixing, installed & testing maintenance free VRLA Battery Bank of 24 Volt Fixed in Power Coated M S Rack With 2x12 Cell Of 120 A H each & Complete assessors like Tined Copper Connecting Strip all terminals Covered by suitable acrylic Sheet along with following :- Technical specification of Each Cell - (i) AH Capacity -110Ah (ii) Cell Type :02 Volt-110 Ah, (iii) Voltage flot 2.23 - 2.25 VPC, (iv) Boost 2.30 -2.32 VPC @ 27 degree C, (v),Current 10-20 Amps Features :- (i) Maintenance frees No Water Requirement. (ii) With Inter Cell connectors system will come complete with an insulated cable kit as well as removable Plexiglas shields making this a very safe system. Complete. Make: Amararaja, Exide , Orient , Amco.
M&L for fault finding in U/G cable using fault locating machine on requirement for 33/11 KV HT cables of any type/size complete all as specified and directed.
Trimming of tree in vicinity of electric supply pole/street light pole/solar modules & depositing at places n exc 50m complete all as specified and directed.
M&L for cleaning of surrounding area of Transformer/GOD on HT two pole and four pole structures at various places etc. complete all as specified and directed
Labour only for fixing cable end termination, jointing kit, HT 33 KV or 11 KV grade, heat shrinkable, indoor/Outdoor type size 95 sqmm 3 core to 240 Sqmm 3 core complete with jointing material suitable for HT XLPE cable 3 core 11 KV grade complete all as specified and directed Note: - (i) HT cable Joint will be issued under Sch ‘B’ free for fixing only.
Labour only for fixing cable straight through, jointing kit, HT 11 KV grade, heat shrinkable, Indoor/outdoor type size 95 sqmm 3 core to 240 Sqmm 3 core complete with jointing material suitable for HT XLPE cable 3 core 11 KV grade complete all as specified and directed Note: - (i) HT cable Joint will be issued under Sch ‘B’ free for fixing only.
Supply, fixing & install Prestressed concrete Pole , 9.0 Meters long 102mm X 152mm at top and 102mm X 289 mm at bottom class 10 etc. complete all as specified and directed
Schedule of Credit
M/S STEADFAST ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .