Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.7 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹40 L+₹58,075 (1.47%)Rejected-Finance 1 14 SUJAL MANSION B BLOCK BHANGWADI KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L2 | Rejected-Finance Other than being Lowest | |
| 3 | L3₹44.1 L+₹4.7 L (12.0%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L3 | Rejected-Finance Other than being Lowest | |
| 4 | L4₹47.9 L+₹8.5 L (21.6%)Rejected-Finance | L4 | Rejected-Finance Other than being Lowest | |
| 5 | L5₹53.0 L+₹13.6 L (34.5%)Rejected-Finance 1 2 GR FLOOR VITHALKUNJ NO 3 V P ROAD ANDHERI WEST MUMBAI 400 058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | L5 | Rejected-Finance Other than being Lowest |
Tender Value
Refer Docs
EMD Value
₹1.1 L
Closing Date
9 Jan 2023, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REPAIR MAINT OF HT LT CAPACITORS BANKS SCADA SYSTEM ETC AT NAVAL DOCKYARD UNDER GE NW KUNJALI COLABA MUMBAI
2022_MES_567408_1
8520/CWE (NW) Mumbai/ E8
Open Tender
Civil Works
Item Rate
365 days
GE (NW) KUNJALI
Class C
7 documents required · 7 mandatory
₹1,000
Yes
GE (NW) Kunjali
₹1.1 L
Yes
8 Mar 2023
5 Dec 2022
11 Jan 2023
5 Dec 2022
9 Jan 2023
26 Dec 2022
5 Dec 2022 - 24 Dec 2022
Amount
Comprehensive maintenance of LT Automatic Power Factor Correction (APFC) panel, monthly basis of Following capacity complete comprising capacitor having low watt loss, thyrestor/contactor, APFC relay, MCCB, Cooling fan, Voltmeter, Ammeter, CTs with all other connected accessories, checking of serviceability of Eachcomponent, cleaning all contact points, tightening of all connections, busbar including replacement of minor components like thimbles, nut, bolt and washers, busbar sleeves, etc if necessary, cleaning the entire panel by using hot blower complete all as specified and directed by Engineer-in-Charge of capacity 75 kVAR at :-
(a) Caisson No 3 - 01 No, Make Crompton Greaves (b) Caisson No 5 - 02 Nos Make Crompton Greaves (c) Caisson No 6 -01 No Make Crompton Greaves (d) Caisson No 9 -01 No Make Crompton Greaves (e) Caisson No 12- 01 No Make Crompton Greaves (e) Caisson No 14- 01 No Make Crompton Greaves (f) Caisson No 16- 01 No Make Crompton Greaves (g) Caisson No 17- 01 No Make Crompton Greaves
All as per item No 1.00 but of capacity 225 kVAR at complete all as specified and directed by Engineer-in-Charge Barrack Wharf - 04 No, Make Crompton Greaves
All as per item No 1.00 but of capacity 300 kVAR at complete all as specified and directed by Engineer-in-Charge. (a) MRSS - 01 No, Make L&T (b) SS No-1 - 01 No, Make Dipen Electrical (c) MRSS - 01 No, Make Dipen Electrical (d) SS No-2 - 01 No, Make Dipen Electrical (e) SS-3 - 01 No, Make Dipen Electrical (f) SS-4 - 01 No, Make Dipen Electrical
All as per item No 1.00 but of capacity 450 kVAR at complete all as specified and directed by Engineer-in-Charge (a) Cruiser Wharf - 02 No, Make Vrindavan Corp (b) IBWSS - 01 No, Make Epcos
All as per item No 1.00 but of capacity 600 kVAR at complete all as specified and directed by Engineer-in-Charge (a) MRSS - 01 No, Make Quantum (b) SS No-1 - 01 No, Make Dipen Electrical (c) SS No-2 - 01 No, Make Dipen Electrical (d) SS No-3 - 01 No, Make Dipen Electrical (e) SS No-4 - 01 No, Make Dipen Electrical
All as per item No 1.00 but of capacity 950 kVAR at complete all as specified and directed by Engineer-in-Charge. (a) EKM -01 No, Make Neopower (b) Caisson No-18 - 01 No, Make Neopower
Notes: The quoted rates are inclusive of the cost of replacement of nut, bolt & washers, thimbles used while servicing the APFC panels as directed by the Engr-in-charge. (ii) The tools required shall deemed to be included in the above quoted rate. (iii) Spares for unserviceable components to be replaced shall be measured and paid separetely. (iv) If the contractor is failed to carry out the monthly servicing of the panel, a penalty of double the quoted rate will be recovered. (v) Contractor shall be ensured that the APFC panel functional through out the contract period and power factor reading shall not fall under 0.95 PF (vi) Contractor shall submit a monthly maintenance programme with location to the Engr-in-charge and the maintenance shall be carried out in the presence of JE/Engr-in-Charge with out fail.
Supply only APFC relay, 8 Stage, auto set function, having digital display, make etaSMART of L&T Cat Part No CS90902OOOO or equivalent in Neptune, Epcos complete all as specified and directed by Engineer-in-Charge
Supply only APFC relay, 12 Stage, auto set function, having digital display, make etaSMART of L&T Cat Part No CS90903OOOO or equivalent in Neptune, Epcos complete all as specified and directed by Engineer-in-Charge
Supply only APFC relay, 16 Stage, auto set function, having digital display, make etaSMART of L&T Cat Part No CS90905OOOO or equivalent in Neptune, Epcos complete all as specified and directed by Engineer-in-Charge
Supply only capacitor duty contactor of make L&T Cat Part No CS96127 or equivalent in Havells, Epcos suitable for upto 5 kVAR rating , complete all as specified and directed by Engineer-in-Charge
Supply only capacitor duty contactor of make L&T Cat Part No CS96156 or equivalent in Havells, Epcos suitable for upto 10 kVAR rating , complete all as specified and directed by Engineer-in-Charge
Supply only capacitor duty contactor of make L&T Cat Part No CS96321 or equivalent in Havells, Epcos suitable for upto 12.5 kVAR rating , complete all as specified and directed by Engineer-in-Charge
Supply only capacitor duty contactor of make L&T Cat Part No CS90019 or equivalent in Havells, Epcos suitable for upto 15 kVAR rating , complete all as specified and directed by Engineer-in-Charge
Supply only capacitor duty contactor of make L&T Cat Part No CS96322 or equivalent in Havells, Epcos suitable for upto 25 kVAR rating , complete all as specified and directed by Engineer-in-Charge
Supply only capacitor duty contactor of make L&T Cat Part No CS96324 or equivalent in Havells, Epcos suitable for upto 50 kVAR rating , complete all as specified and directed by Engineer-in-Charge
Supply only capacitor duty contactor of make L&T Cat Part No CS96150 or equivalent in Havells, Epcos suitable for upto 75 kVAR rating , complete all as specified and directed by Engineer-in-Charge
Supply only capacitor duty contactor of make L&T Cat Part No CS96158 or equivalent in Havells, Epcos suitable for upto 100 kVAR rating , complete all as specified and directed by Engineer-in-Charge
Supply only HRC fuse 6-32 Amps, with Fuse holders & Fuse bases complete all as specified and directed by Engineer-in-Charge
Supply only HRC fuse 63 Amps, make L&T Cat Part No SF94027 complete all as specified and directed by Engineer-in-Charge
Supply only HRC fuse 80 Amps, make L&T Cat Part No SF94028 complete all as specified and directed by Engineer-in-Charge
Supply only HRC fuse 100 Amps, make L&T Cat Part No SF94029 complete all as specified and directed by Engineer-in-Charge
Supply only LED indicator lamp (RED, YELLOW, GREEN), complete all as specified and directed by Engineer-in-Charge
Supply only push button of any colour, complete all as specified and directed by Engineer-in-Charge
Supply only PVC Cooling fan for APFC panel as per sample , complete all as specified and directed by Engineer-in-Charge
Supply only VAF+PF meter, accuracy class 1.0, 5 Amp, flash mounting 96 X 96 mm, 90 - 300 VAC, 3 phase, make L&T Cat Part No WL411010OOOO or equivalent in havells, legrand complete all as specified and directed by Engineer-in-Charge
Supply only, ACB, four pole, 1000 Amps drawout type with micro processor release 50 kA, having breaking capacity 50 KA ,complete all as specified and directed by Engineer-in-Charge
Supply only, ACB, four pole, 1250 Amps drawout type with micro processor release 50 kA, having breaking capacity 50 KA ,complete all as specified and directed by Engineer-in-Charge
Supply only, MCCB, three pole, 630 Amps with thermal magnetic release with range 500 - 630 Amp,, having breaking capacity 36 KA make L&T Cat part No CM94006OOT1OG complete all as specified and directed by Engineer-in-Charge
Supply only, MCCB, three pole, 400 Amps with thermal magnetic release with range 320 - 400 Amp, having breaking capacity 36 KA,make L&T Cat part No CM98401OOROOG complete all as specified and directed by Engineer-in-Charge
Supply only, MCCB, Three pole, 250 Amps with thermal magnetic release with range 200 - 250 Amp, having breaking capacity 36 KA ,make L&T Cat part No CM92009OOP1OG complete all as specified and directed by Engineer-in-Charge
Supply only, MCCB, Three pole, 200 Amps with thermal magnetic release with range 160-200 Amp, having breaking capacity 36 KA ,make L&T Cat part No CM92009OON1OG complete all as specified and directed by Engineer-in-Charge
Supply only, MCCB, Three pole, 160 Amps with thermal magnetic release with range 125-160 Amp, having breaking capacity 36 KA ,make L&T Cat part No CM92008OOM1OG complete all as specified and directed by Engineer-in-Charge
Supply only MCCB, Three pole, 125 Amps with thermal magnetic release with range 100-125 Amp, having breaking capacity 36 KA ,make L&T Cat part No CM92008OOL1OG complete all as specified and directed by Engineer-in-Charge
Supply only MCB, DP 0.5 to 4 Amp, 10 kA "C" curve, 230 volt AC ,complete all as specified and directed by Engineer-in-Charge
Supply only, MCB, DP 6 to 32 Amp, 10 kA "C" curve, 230 volt AC ,complete all as specified and directed by Engineer-in-Charge
Supply only, MCB, DP 40 to 63 Amp, 10 kA "C" curve, 230 volt AC ,complete all as specified and directed by Engineer-in-Charge
Supply only, MCB TP 6-32 Amps,10KA complete all as specified and directed by Engineer-in-Charge
Supply only, MCB TP 40-63 Amps,10KA complete all as specified and directed by Engineer-in-Charge
Supply only, MCB TP 100 Amps,16KA complete all as specified and directed by Engineer-in-Charge
Material and labour for LT Danger notice plate of size 20 X 15 cm of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures, and conventional skull and bones, in signal red colour and fixed with MS clamps, bolts, and nuts of approved size complete all as specified and directed by Engineer-in-Charge
Supply only, in repair copper wound detuned reactors 7%, 3 phase, 440 Volts, 10 kVAR rating, suitable for fixing with the existing capacitor bank panel complete all as specified and directed by Engineer-in-Charge M
Supply only, in repair detuned reactors 7%, 3 phase, 440 Volts, 15 kVAR rating, suitable for fixing with the existing capacitor bank panel complete all as specified and directed by Engineer-in-Charge
Supply only, in repair detuned reactors 7%, 3 phase, 440 Volts, 20 kVAR rating, suitable for fixing with the existing capacitor bank panel complete all as specified and directed by Engineer-in-Charge
Supply only, in repair detuned reactors 7%, 3 phase, 440 Volts, 25 kVAR rating, suitable for fixing with the existing capacitor bank panel complete all as specified and directed by Engineer-in-Charge
Supply only, in repair detuned reactors 7%, 3 phase, 440 Volts, 50 kVAR rating, suitable for fixing with the existing capacitor bank panel complete all as specified and directed by Engineer-in-Charge
Supply only, in repairs thyristor switching module for 10 kVAr, 3 phase, 440 Volts, 50 Hz complete all as specified and directed by Engineer-in-Charge
Supply only, in repairs thyristor switching module 25 kVAr, 3 phase, 440 Volts, 50 Hz complete all as specified and directed by Engineer-in-Charge
Supply only, in repairs thyristor switching module for 50 kVAr, 3 phase, 440 Volts, 50 Hz complete all as specified and directed by Engineer-in-Charge
Supply only capacitor 5 kVAR cylindrical type standard duty 440 volts 3 phase complete all as specified and directed by Engineer-in-Charge
Supply only capacitor 10 kVAR cylindrical type 440 volt 3 phase complete all as specified and directed by Engineer-in-Charge
Supply only capacitor 20 kVAR cylindrical type 440 volt 3 phase complete all as specified and directed by Engineer-in-Charge
Supply only capacitor 25 kVAR cylindrical type 440 volt 3 phase complete all as specified and directed by Engineer-in-Charge
Supply only capacitor 50 kVAR box type heavy duty 440 volt 3 phase complete all as specified and directed by Engineer-in-Charge
Supply only capacitor 20 kVAR box type heavy duty 440 volt 3 phase complete all as specified and directed by Engineer-in-Charge
Supply only capacitor 15 kVAR box type heavy duty 440 volt 3 phase complete all as specified and directed by Engineer-in-Charge
Supply & fixing HT Capacitor 4.04 KV 1-Phase 50 Hz 79.50 kVAR complete all as specified and directed by Engineer-in-Charge
Supply & fixing HT Capacitor 4.04 KV 1-Phase 50 Hz 53 kVAR complete all as specified and directed by Engineer-in-Charge
Supply & fixing HT Capacitor 4.16 KV 1-Phase 50 Hz 99.16 kVAR complete all as specified and directed by Engineer-in-Charge
Supply & fixing series reactor for HT Capacitor bank 4.76 X 3, 6.6 KV dry complete all as specified and directed by Engineer-in-Charge
Supply & fixing series reactor for HT Capacitor bank 3.18 X 3, 6.6 KV dry complete all as specified and directed by Engineer-in-Charge
Supply & fixing series reactor for HT Capacitor bank 35.7 kVAR 6.6 KV oil type complete all as specified and directed by Engineer-in-Charge
Supply & fixing HT Capacitor 4.04 KV 1-Phase 50 Hz 53kVAR complete all as specified and directed by Engineer-in-Charge
Material and labour for earthing complete with galvanized steel earth electrode of size 600 X 600x6mm thick buried directly in ground earth pit not less than 2.25 m deep below normal GL with top edge of the earth plate not less than 1.5m below GL connected with GI earth strip 32 X 6 mm (up to 7.5m long) by means of GI nuts bolts and washers etc. MS funnel, GI watering pipe, including provn of PCC 1 : 3 : 6 type C 2 pit and RCC 1 : 2 : 4 Type B-1 cover 40mm thick, excavating & earthwork in any type of soil & removal of surplus soil up to 50M, all as all as shown in SSR part I electrical plate No-3, and testing on completion, complete all as specified and directed by Engineer-in-Charge
Disconnecting & taking down old unserviceable cable & Supply and laying in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3½ core in trenches/ wall complete all as specified and directed by Engineer-in-Charge
Disconnecting & taking down oldunserviceable cable & Supply and laying in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3½ core in trenches/ wall complete all as specified and directed by Engineer-in-Charge
Disconnecting & taking down old Unserviceable cable & Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3½ core in trenches/ wall complete all as specified and directed by Engr-in-Charge.
Disconnecting & taking down old unserviceable cable & Supply and laying in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3½ core complete all as specified and directed by Engr-in-Charge.
Supply, Installing, testing of MV vaccum Contactors with following specifications. Rated Voltage 6.6 KV 11 Kvv Rated Frequency : 50 Hz Rated Current : 400 A Rated Motor Switching current 400 A Peak Making current 10 KA/ 25 KA complete all as specified and directed by Engineer-in-Charge
Supply & fixing of neutral Displacement Protection Relay, Model IRU-PRO-2 complete all as specified and directed by Engineer-in-Charge
Supply & fixing of VC Card, Model CGVCCER/NO01/N3 complete all as specified and directed by Engineer-in-Charge
Supply & fixing of HRC fuse 72 Amps 11 KV complete all as specified and directed by Engineer-in-Charge
Supply & fixing of Air brake contactors, control voltage 230 volts complete all as specified and directed by Engineer-in-Charge
Supply & fixing of indicator lights complete all as specified and directed by Engineer-in-Charge
Supply & fixing of emergency stopper complete all as specified and directed by Engineer-in-Charge
Supply & fixing 4 step 3 Phase APFC relay with communication port RA485 Microprocessor based cut out size 144 x 144 x 80mm complete all as specified and directed by Engineer-in-Charge
Supply & fixing full control wiring of the panel (including wire) complete all as specified and directed by Engineer-in-Charge
Supply & fixing of Timer control complete all as specified and directed by Engineer-in-Charge
Supply & fixing of hooter complete all as specified and directed by Engineer-in-Charge
Supply & fixing of Auto/ Manual Switch complete all as specified and directed by Engineer-in-Charge
Chakshu Enterprise
Shree Ayyappa Engineering
Expert Electric Service And Stores
Darpan Construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .