Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.0 LAccepted-Finance | L1 | Accepted-Finance OK | |
| 2 | L2₹36.4 L+₹45,689 (1.27%)Accepted-Finance | L2 | Accepted-Finance OK | |
| 3 | L3₹37.0 L+₹95,919 (2.66%)Accepted-Finance | L3 | Accepted-Finance OK | |
| 4 | L4₹37.7 L+₹1.7 L (4.85%)Accepted-Finance | L4 | Accepted-Finance OK | |
| 5 | L5₹39.9 L+₹3.9 L (11.0%)Accepted-Finance | L5 | Accepted-Finance OK |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
6 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Utility Secunderabad
GARRISION ENGINEER U SECUNDERABAD
REPAIR / MAINTENANCE OF SWIMMING POOL AND CONNECTED WORKS OF AOC CENTRE UNDER GE (U) SECUNDERABAD
2023_MES_625843_2
GE(U)/SEC/TOKEN/44 OF 2023-24
Open Tender
Civil Works - Water Works
Item Rate
270 days
SECUNDERABAD
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
G
₹82,000
Yes
27 Jan 2024
18 Dec 2023
13 Jan 2024
18 Dec 2023
6 Jan 2024
1 Jan 2024
Amount
M &L for pressure washing and cleaning thoroughly the bottom floor and inside walls of 700000 gallons capacity swimming pool after draining out of water including cleaning of joints of tiles of the pool by suitable mechanical means using mild hydrochloric acid for fungus/algae free surfaces including removing out all dirt and foreign matters if any from the pool to a distance not exceeding 50m complete to the satisfaction of the Engineer-in-Charge all as specified and directed. Notes :- (a) Size of the Swimming Pool is 50m length x 25m width and depth varying from 1.2m to 3m (Approx). (b) Draining of water from the Swimming Pool shall be made by the department. (c) Draining of water, pump & motor provided by contractor for suitable capacity.
M&L for pressure washing and cleaning thoroughly the bottom and inside walls of balancing tank of the swimming pool after draining out of water by suitable mechanical means using bleaching powder including removing of sludge/slurry/foreign matters if any from the tank to a distance not exceeding 50m complete to the satisfaction of the Engineer-in-Charge all as specified and directed. Notes :- (a) Size of the Balancing tank is 3.6m length x 2.9m width and depth 4m (Approx) (b) Draining of water from the Balancing tank shall be made by the department. (c) Draining of water, pump & motor provided by contractor for suitable capacity.
Supply on PVC flexible suction and delivery hoses, ISI marked incorporating a rigid PVC priral as an integral part of the soft PVC balls green ribbed colour of 40 mm dia - 40 Nos, working pressure @ 6 kg/Sqcm complete all as specified and directed.
S&F sub main wiring complete with 3 runs of 6 Sqmm, circular compacted minimum 18 conductor PVC insulated heavy duty, unsheathed copper conductor and drawing through in heavy duty and connecting terminal ends panel and motor starter panel including lugs, 1 run of 4 Sqmm, insulated copper cable for earth continuity conductor and connecting to earth dolly complete all as specified and directed.
cleaning of swimming pool (2 / 3 days in a week as per requirement ) including by providing of minimum 4 Nos labour for operating of suction sweeper & submersible pool cleaner and mannual cleaning by using brushes, sweeps etc to the floor sides of walls, over flow water channel of swimming pool surrounding area removing all floated materials/insects from pool water and removing all foreign materials muds etc from pool area to outside of the pool not less than 50 mtr as directed at site Engr-in-charge. Note :- (i) Daily maintenance of swimming pool is to be carriied out as per operating time schedule of the swimming pool, i.e. wef 9:30 AM to 3:00 PM. and all T&P are the responsibilitry of the contractor (ii) Surrounding areas of the pool including plant room shall be cleaned after 3:00 PM & upto 5:30 PM.
M&L for Filter media refilling of Quartz sand sewed as per the standards and details are as followa. Fine sand 16X32 mesh of 450 mm depth = 2X7.0MT
Labour charges washing of filter media (pebbles) and re filling of pebbles and new media and complete to the satisfaction of the Engineer-in-charge all as specified and directed.
M&L for inside painting of filters two coat of red oxide and two coats of epoxy and complete to the satisfaction of the Engineer-in-charge all as specified and directed.
Supply only PVC flexible suction and delivery hoses, ISI marked incorporating a rigid PVC spiral as an integral part of the soft PVC wall green ribbed colour of 50 mm dia, working pressure @ 6 kg/Sqcm complete all as specified and directed.
Supply only liquid amonia in 450 ml PVC bottle complete all as specified and directed. Make :- Pearl Filler/RMCO/Mizag.
Supply only free chlorine testing kit paper strips (Colome metric TMG) for detection levels (0.05, 0.1, 0.4, 0.6, 0.8, 1.2, 1.5, 2.0, 4.0, 6.0 ppm (Mgle) test time 40 seconds having each bottle of 50 test strips complete all as specified and directed.
Supply only Tri chloro isocyanuric acid (TCCA-90) in white granular form for disinfectant for swimming pool of supar quality contains chlorine 90 % duly packed in 50 kg drum 100% solvable in water, having molecular weight 23.44 and appearance in white PH value 1% solution - 2.7 to 3.3 and moisture level 0.5% complete all as specified and directed.
Supply only non alum ferric best quality, ISI marked suitable for using at water treatment plant for drinking purpose complete all as specified and as directed.
Supply only bleaching powder of 30% chlorine available, ISI marked Grade-I QUALITY CONFORMING TO is 673 PACKED IN FACTORY SEALED POLY PACK AND DELIVERED AT AGE E/M II (U) store yard complete all as specified and as directed.
Supply only Hydrochloric acid industrial grade (in 50 ltr container) complete all as specified and directed.
Supply only Calcium Hypochlorite calcium based high strength granular chlorine having 65 % - 70 % chlorine content packed in 45 Kgs PVC sealed container, superior quality suitable for treatment of drinking water and swimming pool ( Much more stable than chlorine gas, bleaching power and sodium hypochlorite) all as specified and directed. NOTE :- Approval of chemical (calcium hypochlorite) shall be given after verifaction of test certificates of chemical of various manufactures and other factores like chemical and safety and health hazard aspects of usage of chlorination . Make of the chlorination of chemical must be stated in production of certificate duly certified by govt laboratory conforming compliance of specification suitable for drinking water with a declartion from the laboratory that from the technical strengh stability health safety and operation point of view , this product is used for drinking water applications for consumption by humans and the brand/make of calcium hypochlorite is suitable for drinking water chlorination and its sample has been tested by Govt Laboratory. Traditional means of chemical shall be used subject to fulfil the parameters specified in the manual on water supply and treatment (Third edition May 1999) issued by Central Public Health and Environmental Engineering Organisation (CPHEEO), Ministry of Urban Development New Delhi. The contractor shall produce manufacturers "Certificate of Compliance" indicating date of manufacturer in original alongwith every consignment of supply. Test certificate from Govt approved Test Laboratory shall accompany with every consignment of supply to ensure that the materials supplied are in with conformity with relevant IS.
Supply only soda ash confirming to IS complete all as specified and directed.
Supply only copper sulphate crystal, ISI marked to maintain the H2O standards complete all as specified and directed. Notes for item No 7 to 13 :- (i) Contractor shall supply material as per monthly requirement basis in bags/containers as and when directed at various installation of AGE E/M No-II. (ii) The quoted rate is deemed to be included complete labour and transportation for the materials at various installations of AGE E/M No II with out any extra cost. (iii) Supplier must provide alongwith materials, "certificate of compliance"/"Test certificate" in original indicating Batch No, date of manufacturing and quantity supplied.
Supply only water hardness test kit digital type (PH test kit) complete all as specified and directed.
Supply only nylon rope of size 1" (Inch) dia suitable for suction sweeper complete all as specified and directed.
M&L for repairs/replacement of suction sweeper i.e wheel, leather patti, wheel hook, nut, bolt,washer and brushes of suitable size complete all as specified and directed
Supply only leaf net, deep bag net made in polypropelen and white polyester netting including butterfly connection for swimming pool complete all as specified and directed.
Supply only surface net made in polypropelen and white polyester netting butterfly connection for swimming pool complete all as specified and directed.
Supply only extensionable handles for cleaning attachments in anodized aluminium which can be adapted to the entire range of cleaning equipment, brushes, leaf skimmers and scoops, 7.5 mts, long for swimming pool complete all as specified and directed.
Supply only transparent blue plastic vacuum hose 2" (Inch) dia, 30 mtrs long medium grade including hose cuffs for connection to suction inlets complete all as specified and directed.
Supply only of curved brushes made in polypropelene for pool basins and scum liners complete all as specified and directed.
Supply only straight brushes made in polypropelene for pool basins and scum liners complete all as specified and directed.
Supply only Suction sweeper wheels as per sample of swimming pool complete all as specified and directed.
Disconnecting and removing the water and electric connections carefully from the existing submersible pump sets of capacity 3 HP to 10 HP and taking out the pump set alongwith pipes and fittings for flushing the bore well upto 450 feet depth or repair the pump set and strip opening the pump set for repairs/replacement of worn out spares, refixing of serviceable spares, assembling the pump set completely, testing of pump set, lowering the pump set inside the bore well after repairs including connecting back the water and electric connections, commissioning of pump set for satisfactory operation on its full load complete all as specified and directed. Note :- The spares required for repair the pump sets and rewinding of motors will be measured and paid seperetely.
Disconnecting and removing the water and electric connections carefully from the existing submersible pump sets of capacity 5 HP to 10 HP and taking out the pump set alongwith pipes and fittings for flushing the bore well above 450 feet and upto 750 feet depth or repair the pump set and strip opening the pump set for repairs/replacement of worn out spares, refixing of serviceable spares, assembling the pump set completely, testing of pump set, lowering the pump set inside the bore well after repairs including connecting back the water and electric connections, commissioning of pump set for satisfactory operation on its full load complete all as specified and directed. Note :- The spares required for repair the pump sets and rewinding of motors will be measured and paid seperetely.
M&L for rewinding the Submersible pump Motor with PVC insulated, super enamelled copper conductor with ‘F’ class heavy grade insulation weight and turns to achieve its full efficiency inclduing tying the winding and connecting the coils and brining the connections as that of exisitng one including applying insulating varnish, heating and backing the windings thoroughly including taking down old existing copper winding complete all as specified and directed for Submersible pump motor of following capacity :-
Submersible Motor upto and including upto 5 HP.
Submersible Motor above 5 HP up to 10 HP.
Supply only the following spares suitable for existing make of submersible pump set 3 to 10 HP capacity, multi stage for repairs complete all as specified and directed :-
Gun metal Impeller.
Stage casing.
SS Sleeves.
Middle bush.(LB)
Middle sleeve.
Discharge outlet.(LB)
Pump coupling.
DOL SS Sleeve.
Suction bush.
Pump Shaft
S&F PVC insulated Copper conductor, sheathed, Submersible flat cables of size 4 Sqmm, 3 core, for Submersible Pumps, 1100 Volts grade, conforming to IS:694/1990 with latest amendments cutting to required length connecting with necessary end ferrules / water proof joints and jointing and testing including disconnecting/taking out old existing cable complete all as specified and directed.
material and labour for Rubber mat of size 1mX2mX20mm ISI marked
Material labour for removing submerceable pump motor set of capacity up to 10 HP stuck in side the borewell of depth up to 100 meter including by flushing the existing borewells of any size with drilling compressor mounted on truck at a pressure of 7 Kg / Sqcm with compressed air and flushing the sand, mud including flushing out tree roots etc from the bore well till discharge of the fresh water and then clear the bore by using Rod drilling using Bore well drilling machine from any kind of obstruction, reinstall the motor and coloumn pipe , necessary electric connection and testing complete all as specified and directed . Note; rate quoted by the contractor inclusive of Flushing by using suitable compressure , rod drilling for clearing of bore well, Removing the submerceable pump set stuck inside the boire well and reinstall the same after repair including removing and refixing of coloumn pipe , electrical connections, testing ets as required .
Supply & fixing HDPE heavy duty coloumn pipe in Bore well internal dia 50mm PN 16kq/Sqmm including all necessary fittings and fixtures as requited for fixing with submerceable motor Complete all as specified and directed. Note: Quoted rate inclusive of fixing of pipe with submerceable motor and lowring in existing bore well
Supply and fixing of DOL Starter suitable for upto 7.5 HP Motor, 5.5 KW and relay max range 20-32 Amp as in repairs complete all as specified and as directed. Makes : L&T cat part No CS90947 or equivalent of Havells/CG as approved.
Supply and fixing of single phase preventer suitable for upto 7.5 HP motor as in repairs complete all as specified and as directed. Make : L&T cat part No CS94824DOOO or equivalent of Havell/MINILAC
Supply,installation and replacement of pump starter electric control panel board, for out door use, DOUBLE door dust & vermin proof floor mounted made out of CRCA steel sheet of 3.15 mm thick angle iron legs of size50x50x5mm, having electrolytic high conductivity insulated bus bar made out of aluminium strips of rating 100 Amps for 3 phase, 415 Volts, 50 C/S 4 wire system, with cable enty jprovision, with suitable lugs gland, voltmeter, Ammeter and phase indicator complete, duly painted with two coats of stove enameled power coated paint over a coat of red oxide primer complete all as including necessary PCC work of height 300 cm from the ground level including disconnecting/taking out old existing unsv pump panel complete all as specified and directed of the following( Leg of the panel should not be less than 0.75 M and size of the panel should not be less than 70CmX60CMX30CM)) :- INCOMMING :- (a) MCCB, 4 pole, 415 Volt, 40 Amps, 16 KA - 01 No (b) 3 Phase LED Voltmeter, class - 0.5 - 01 No (c) 3 Phase LED Ammeter, class -0.5 - 01 No (d) LED Indicator lamp in three colour RYB - 01 Set OUTGOING :- (a) MCCB, 3 pole, 10 KA c Curve 415 volts, 32 Amps -01 No (b) DOL starter in sheet enclosure type MK-1, Motar rating AC-3 duty, 415 volts, 50 Hz suitable FOR 7.5 HP relay max rang 15-25 Amps-01 No. (c) Single hase preventor realy type Sz% (6wire), 415 volts -01 No
Supply and fix Contactor 40 amps 3 phase coil operating operating voltage 230 volt make L&t model cs94190
Supply and fix Contactor 25 amps 3 phase coil operating operating voltage 230 volt make L&t model cs94110
Supply and fix MCB SP&N 32 Amps 10 KA C Curve . Make L&t model BB20320C /Legrand/havells
Supply and fix MCB SP&N 25 Amps 10 KA C Curve . Make L&t model BB20325C /Legrand/havells
Supply and fix MCB SP&N 20 Amps 10 KA C Curve . Make L&t model BB20200C /Legrand/havells
Supply and fix MCB TP&N 20 Amps 10 KA C Curve . Make L&t model BB40200C /Legrand/havells
Supply and fix MCB TP&N 32 Amps 10 KA C Curve . Make L&t model BB40320C /Legrand/havells
Disconnecting, dismantling and taking aside the Pump set of 05 to 7.5 HP capacity for replacement of existing base frame with new one from the installed position and dismantling of existing PCC / RCC foundation and refixing the same motor by preparing sufficient PCC foundation and base frame reqiured for 5hp/7.5 hp HP pump including connecting items like nuts, bolts and setting the alignemnt of motor and pump set testing and commissioning all as specified and directed. Note:The quoted rate will be inclusive of required replacement of baseframe/MS channel and PCC / RCC for foundation.
Arresting lekages from pumps of motor capacity 05 HP to 25 HP by replacing gasket, nutbolts, gland packing etc as required complete all as directed Note: Rate quoted by the contractor inclusive of all items as requiree to arrest the leakages from pumps
M&L for flushing of existing borewells of any size upto 150 Mtrs depth with drilling compressor mounted on truck including surging and flushing the bore at a pressure of 7 Kg / Sqcm with compressed air and flushing the sand, mud including flushing out tree roots etc from the bore well till discharge of the fresh water including testing of water samples for chemical and bacteriological tests and complete all as specified and directed .
M&L for flushing of existing borewells of any size upto 250 Mtrs depth with drilling compressor mounted on truck including surging and flushing the bore at a pressure of 7 Kg / Sqcm with compressed air and flushing the sand, mud including flushing out tree roots etc from the bore well till discharge of the fresh water including testing of water samples for chemical and bacteriological tests and complete all as specified and directed .
M & L for shifting of cetrifugal monoblock Motor of capacity 5 HP to 10 HP to a new location as directed after disconnecting from existing position including making base by using PCC (!:2:4 by using 20 mm gravel of size not less than 1 M X0.75 X0.75 M and base by using C Channel of suitable size and making electric and water connection complete all as specified and directed. Note : Quoted rates inclusive all arrangements required for Shifting of Pumpset
Serviceaning / periodical checking of Starter panel board suitable for 15 HP to 40 HP Motor by replacing all unserviceable parts , checking for any kind of loose contact , identification of fault etc complete all as specifed and directed . Note : All spare to be replaced and measured under relivent items.
Serviceaning / periodical checking of Starter panel board suitable for 5 HP to 10 HP Motor by replacing all unserviceable parts , checking for any kind of loose contact , identification of fault etc complete all as specifed and directed . Note : All spare to be replaced and measured under relivent items.
Servicing of Submerceable pump motor set of capacity up to 10 HP complete all as directed
Taking up or down steel tubing laid in trenches, on wall/in floor, in plinth protection of Bldg including segregation of serviceable pipes and keep in safe custody for reuse, complete with all fittings and connections of the following sizes:-
25 mm dia
40 mm dia
50 mm dia
Supply and laying steel water tubing medium grade, galvanised with all fitting, laid in wall / trenches and testing for leakages complete all as specified and directed for the following sizes:- NOTE : rate quoted by the contractor incluisive of all kind of fittings, bends, flenge , thread cutting etc as required for proper fixing of pipe
25 mm dia
40 mm dia
50 mm dia
M&L for Disconnecting the suction and delivery pipe line and electric connections of centrifugal monoblock pump set 7.5 HP to 25 HP capacity and removing it from its position carefully and transporting the same to the work shop and refixing the same in its original position after carryout the repairs and connecting back the water and electric connections including testing and commissioning complete all as specified and directed.
M&L for Disconnecting the suction and delivery pipe line and electric connections of centrifugal monoblock pump set 1 HP to 5 HP capacity and removing it from its position carefully and transporting the same to the work shop and refixing the same in itsoriginal position after carryout the repairs and connecting back the water and electric connections including testing and commissioning complete all as specified and directed.
M&L for rewinding of centrifugal motor with super enameled copper conductor of same guage, weight and turn to achieve its full efficiency including tying the windings and connecting the coils and brining the connections as that of existing one including renewal of worn out/unserviceable bearings etc complete all as specified and directed for following capacity :-
(a) Centrifugal motor 20 /25 HP capacity.
(b) Centrifugal motor 10/15 HP capacity.
(b) Centrifugal motor 5.0/7.5 HP capacity.
(c) Monoblock motor 1/3 HP capacity.
M&L in repair of centrifugal pump set of 1 to 5 HP capacity to achieve the water discharge as per manufacturer recommendation including replacement of worn out unserviceable parts complete all as specified and directed. Notes :- (i) Expendable stores like cotton waste/cleaning materials, lubricants, gland packing, metal filling, matchining and transportation to and from site to work shope are deemed to be included in unit rate quoted. (ii) Labour against this item for replacement of spares (supply only items) shall be deemed to be included in the rate quoted. (iii) Spare parts like SS sleelves, impeller, stage casing etc shall be measured and paid separately under relevant item of Sch 'A'.
Supply only the following spares for repairs of centrifugal / monoblock pump set of up to 5 HP capacity complete all as specified and directed :-
Ball bearing suitable for induction motor.
Ball bearing for non drive end suitable for pump.
GM bush.
CI impeller.
MS pump shaft.
Gland cover.
M&L in repair of centrifugal pump set of 7.5 to 25 HP capacity to achieve the water discharge as per manufacturer recommendation including replacement of worn out unserviceable parts complete all as specified and directed. Notes :- (i) Expendable stores like cotton waste/cleaning materials, lubricants, gland packing, metal filling, matchining and transportation to and from site to work shope are deemed to be included in unit rate quoted. (ii) Labour against this item for replacement of spares (supply only items) shall be deemed to be included in the rate quoted. (iii) Spare parts like SS sleelves, impeller, stage casing etc shall be measured and paid separately under relevant item of Sch 'A'.
Supply only the following spares for repairs of Centrifugal pump set of 7.5 to 25 HP capacity complete all as specified and directed :-
(a) Ball bearing drive end for suitable size.
(b) Ball bearing for non driving end of suitable size.
(c) Gun Metal bush.
(d) CI impeller.
(e) MS pump shaft.
(f) Gland cover.
(g) Gland.
M&L for dismantling of defective sluice valve for repairs, such as repacking stuffing box of sluice valve spindle, refacing, grinding, stuffing and threading of spindle, replacement of worn out check nut, repairs to gate assembly etc, replacement of jointing materials such as rubber sheets, nuts, bolts, washers and gland rope etc and refixing in its original position, testing on completion complete all as specified and directed for the following sizes:-
(a) 100 mm Dia
(b) 150 mm Dia
(c) 200 mm Dia
Supply and fix in replacement of unserviceable Gun metal (Bronze) Gate, globe & check valves IS : 778/1980 CL-1, K604 type connected with iron wheel head, screwed at both ends for iron pipes and fixed complete all as specified and directed for the following sizes:-
(a) 20mm dia bore
(b) 25mm dia bore
(c) 40mm dia bore
(d) 50mm dia bore.
S&F in replacement of Cast Iron sluice valves as per sample of swimming pool filtration plant, flanged ends stem of SS (AISI410) & Bronze (Gun Metal) working parts IS : 14846 both ends flanged with clamps and check nuts, operating wheel etc, non rising type K504, class PN 1.6 including jointing materials connecting and testing complete all as specified and directed :-
100 mm Dia
150 mm Dia
200 mm Dia.
S&F, connecting and testing in repair of Cast Iron double orifice kinetic Air Valve 65 mm dia as per sample, ISI Marked IS : 14845 type DK in PN 1.0 flanged end K541 with all standard accessories and tested including replacement of nuts, bolts, washers, gaskets, packings etc complete all as per specified and directed.
S&F, connecting and testing in repair of Cast Iron foot Valves 150 mm dia flanged ends swing type operation with rubber seat as per IS : 4038 single disc with all standard accessories and tested including replacement of nuts, bolts, washers, gaskets, packings etc complete all as specified and directed.
S&F, connecting and testing in repair of Cast Iron non return (Reflux) valves flanged ends in swing type design IS-5312 part-I, K517, PN-1.6, 150 mm dia both ends flanged etc including jointing materials of sizes complete all as specified and directed.
S&F, connecting and testing in repair of brass non return (Reflux) valves flanged ends in swing type design IS-5312 part-I, 65 mm dia etc including jointing materials of sizes complete all as specified and directed.
M&L for repair of ozonator unit of 100 gm/hrs, with oxygen concentrator complete all as directed including testing after installation. . Note : Quoted rates inclusive of testing in presence of authorised representative of manufacturer after installation . Quoted rates inclusive of all aspare parts required for repairing of ozonator unit.
S&F in replacement Fully Automatic star-delta starter max motor output at 415V, 3 Phase, suitable for 25 HP Centrifugal pump, relay max range 14-23 Amp, model No MN 25 FASD heavy duty complete all as specified and directed. Make : L&T Cat Part No SS94364 or equivalent AS APPROVED
S&F loadline MCCB (Conforms to IEC : 60947-II / IS : 13947-II) in existing LT Panel box / feeder pillar boxes, Adjustable & Fixed thermal magnetic setting of capacity 63 Amps, 3 pole, 16 KA, 415 Volts including disconnecting/Taking out existing old unsv/burned complete all as specified and directed.
S&F loadline MCCB (Conforms to IEC : 60947-II / IS : 13947-II) in existing LT Panel box / feeder pillar boxes, Adjustable & Fixed thermal magnetic setting of capacity 160 Amps, 4 pole, 36 KA, 415 Volts including disconnecting/Taking out existing old unsv/burned complete all as specified and directed.
S&F loadline MCCB (Conforms to IEC : 60947-II / IS : 13947-II) in existing LT Panel box / feeder pillar boxes, Adjustable & Fixed thermal magnetic setting of capacity 250 Amps, 4 pole, 36 KA, 415 Volts including disconnecting/Taking out existing old unsv/burned complete all as specified and directed.
Supply and replace digital Ammeter(0-200/400 amps as per site requirement) with auxiliary supply voltage 230 volt complete all as specified and directed. Make l&T/AE/Secure
Supply and replace digital Voltmeter(0-500 volt) as per site requirement) with auxiliary supply voltage 230 volt complete all as specified and directed. Make l&T/AE/Secure
Supply and replace Water flow meter( M3/hr) at swimming pool plant room as per the existing make and model / equivalent complete all as specified and directed. Make Exide / equivalent as approved
S&F in replacement of Cast Iron sluice valves installed inside the balancing tank of AOC Swimming pool including its ncessary arrangement to operate it from the top of the tank , flanged ends stem of SS (AISI410) & Bronze (Gun Metal) working parts IS : 14846 both ends flanged with clamps and check nuts, operating wheel etc, rising type K504, class PN 1.6 including jointing materials of 150 mm dia connecting and testing complete all as specified and directed.
S&F in replacement of 200 mm dia Cast Iron sluice valves as per sample of swimming pool filtration plant, flanged ends stem of SS (AISI410) & Bronze (Gun Metal) working parts IS : 14846 both ends flanged with clamps and check nuts, operating wheel etc, non rising type K504, class PN 1.6 including jointing materials connecting and testing complete all as specified and directed. Make : Aqua
M&L in replacement of Pressure gauge 4" dia, 0-21 Kg rating, 3000 PSI including jointing materials connecting and testing complete all as specified and directed. Make : Thermax, model No - EN 837-1
Supply and fixing of gaskit 200NB W/T NEOPRENE DIAPHRAGM floway valve Nylon reinforced Neoprene rubber diaphragm suitable for floway wear type diaphragm valve code No - HSN/SAC - 4000, suitable for 200 mm dia sluice valve, 14 Nos holes complete all as specified and directed.
Supply and fix in replacement of unserviceable 65 mm dia cast iron Gate valve, connected with iron wheel head, screwed at both ends for iron pipes and fixed complete all as specified and directed, Make : SC Floway, model : 65NB.
Supply and fix in replacement of unserviceable 25 mm dia cast iron Gate valve, connected with iron wheel head, screwed at both ends for iron pipes and fixed complete all as specified and directed, Make : SC Floway, model : 25NB.
Complete removal of existing teatment including preparation of old painted surfaces by washing, rubbing down and stopping of painted surfaces, painting with one coat of synthetic enamel paint of approved colour on centrifugal pump set of 25 HP capacity including inlet, outlet mains, coupling, sluice valve, non return valve, base plate, pully with safe gaurd, vaccume pipe line and writting the MES/SM number with black paint of suitable size of letters complete all as specified and directed.
Complete removal of existing teatment including preparation of old painted surfaces by washing, rubbing down and stopping of painted surfaces, painting with one coat of synthetic enamel paint of approved colour on horizontal type quarts sand filter ( 2 Nos) of capacity 50000 gln/hrs including inlet, outlet mains, coupling, sluice valve, non return valve, base plate, pully with safe gaurd, vaccume pipe line and all exposed pipe insite swimming pool plant room and writting the MES/SM number with black paint of suitable size of letters complete all as specified and directed.
M&L for second class hard wood in scantling alongwith painting of approved colour, all as specified and directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation of PCC/Steel pole, laying of cable/pipe in trenches etc and getting out in hard / dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Supply and fixing in repair Altoch Dosing System Model ADS - PRO multi-cavity water sanitiser / conditioning station with proportional dosing arrangement at zero discharge of the fooolwing specifications: (a) MOC: Non-Metallic, Maximum Temperature: 45 degree Centrigrade, Operation: Power-free Automatic, Dosing pattern: Proportional, Capacity: 100 litres to 200 litres, Compatibility: Stequa 411 AE Refill / Prefil - Total refill, Tank lid must have provision for mounting dosing pump on the lid / wall, Cavities are complete with lids, Attachments: (i) Overflow Valve, (ii) Water Inlet Valve, (iii) Outlet Valve (for offline automated gravity flow) (iv) Drain Valve Make:- As per approval of E-in-C's Branch Note: rate quoted by the contractor inclusive of all arrangement required for functioning of dising system including making hole on exixting CI/DI/MS pipe and connecting pipe as required .
Supply only Stequa 411 AE Refill: Chlorine tablets contained in plastic cylindrical sealed disposable sanitiser refill for disinfection of drinking water, suitable for operation through recommended dosing system. (i) Replacement indication: visual & weight variation (ii) Water contact orifice design: sealed when dry, exposed upon immersion (iii) Operation type: Non contact, non inhalatory (iv) Cylinder dia: 2.5 inches + 0.5 inches (v) Cylinder height : Minimum 10.0 inches + 0.5 inches (vi) Operational stipulations: (a) Heavy metal (Pb & Hg) contamination in the product media must be BDL as per AAS data (b) Minimum volume of water disinfected by each STEQUA 411 AE Refill to obtain disinfection activity of 1 ppm on spot (Influent water quality variation, ambient & site condition variations apply) as per absorbance data generated at λmax 515 nm. Three Hundred Fifty Thousand litres. (c) Stability : Active ingredent stabilty (when stored at 25-45 degree Centigrade temp) must be at least 98% after one year as per data generated by accelerated Stability test protocol. (d) Safety & health hazard aspects on usage of the product media for regular drinking water disinfieciton: Heavy Metal contaminants (like Mercury & lead) in product media must be below detectable limit (BDL), and the product must pass the Acute Toxicity test (to specially confirm non toxicity for mammalian cells), based on which the product must be considered sate to use form human health safety point of view and freedom from toxicity when used in drinking water disinfection in recommedned dosage. (e) Tje refills must ensure infrastructural safety (as per date generated by Electrolytic Conductivity (µs/cm) test protocal) and operators health safety (f) STEQUA Auto Economy REfill 41 AE must be complaint with operators health safety considering regular exposure. The brand and make of the sanitiser mus be staed and certified by a laboratory /study centre of any stae University. Make:- As per approval of E-in-C's Branch
Supply only STEQUA 412 HD: Plastic cylindrical sealed disposable floating sanitiser station for disinfection of swimming pool & cooling tower water containing algaecide & coagulant with arrangement for controlled release of acive ingredients in water, and head suspender. Disinfection capacity: 16.0 LL Water at 0.5 ppm Ac Cl at release site (subect to site & raw water quality variations). (a) Replacement indication: visual & weight variation (b) Operation type: Non contact, non inhalatory (c) Cylinder Dia:2.5 inches + 0.5 inches (d) Cylinder Height: 26.0 inches+ 0.5 inches (e) Model: Stequa 412 HD Make:- As per approval of E-in-C's Branch.
Stequa Purity Verifier 41021 containing1 comparator with lid, 30 tablets x pH RAPID (Item code: PVPH 3041021), 30 tablets x Chlorine RAPID (Item code: PVFC 3041021), 1 instruction sheet, 1 plastic box. Note: pH range: 6.8-7.0-7.2-7.4-7.6-7.8-8.0-8.2. Chlorine range: 0.1-0.3-0.4-0.5-0.6-0.8-0.9-1.0-1.5-2.0-3.0 Make:- As per approval of E-in-C's Branch
PVPH 41021 Packet of 100 tablets pH RAPID for STEQUA Purity Verifier 41021 Make:- As per approval of E-in-C's Branch
PVPH 41021 Packet of 100 tablets Chlorine RAPID for STEQUA Purity Verifier 41021 Make:- As per approval of E-in-C's Branch
Electrical submerceable swimming pool cleaner with Hose outlet 50 mm, capacity 2HP/1.5KW, Three phase,F/H class insulation, weight 25 to 28 KG, 2 Nos filter bag,Shut of head 12 meter with discharge 620 LPM, STAILLESS STEEL STRAINER including control panel 1.5 Sqmm 4 core water proof wire 30 RM, 50mm hose pipe 12 Rm complete all as specified and directed.
Srinivasa Consructions
bethelenterprises
vvcenterprises
M Shyam Sunder
sree venkateswara enterprises
omsai thermax engineers
L and S ENTERPRISES
SANJEEV CONSTRUCTIONS
Haasith constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .