Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹3.8 LAdmitted-Finance | -6.89% | ₹3.8 L | L1 | Admitted-Finance |
| 2 | L2₹4.1 L+₹28,002.96 (7.29%)Admitted-Finance 00 VIBHAV NAGAR COLONY NAVIPUR KALAN NAVIPUR KALAN HATHRAS UTTAR PRADESH 204101 | HATHRAS | UTTAR PRADESH | 204101 | -0.10% | ₹4.1 L+₹28,002.96 (7.29%) | L2 | Admitted-Finance |
| 3 | L3₹4.2 L+₹40,787.81 (10.6%)Admitted-Finance | +3.00% | ₹4.2 L+₹40,787.81 (10.6%) | L3 | Admitted-Finance |
Tender Value
₹4.1 L
EMD Value
₹8,240
Closing Date
19 Aug 2026, 2:00 pmClosed
Executive Engineer
PWD Electrical Division Medical College Jaipur
Shifting of LT Panel at J.K. Lon Hospital, Jaipur
2026_CEPWD_586564_3
EE_PWD_Medical_NIT_19_2026_27
Open Tender
Electrical Works
Percentage
30 days
Jaipur
Please refer tender documents
2 documents required · 2 mandatory
₹500
Through Egras Challan in Office ID 28560
₹8,240
Yes
In the chamber of Executive Engineer
27 Aug 2026
13 Aug 2026
20 Aug 2026
13 Aug 2026
19 Aug 2026
13 Aug 2026
17 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level | - | - | - | - |
| 1.02 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) | 8 | cum | 4,381 | ₹35,048 |
| 1.03 | Earth work in excavation/ by mechanical means (Hydraulic Excavator) / Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sum on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed: | 13 | cum | 178 | ₹2,314 |
| 1.04 | Plaster on new surface on wall in cement sand mortar 1:4 including racking of joints etc. complete fine finish : | - | - | - | - |
| 1.05 | 12mm thick | 10 | Sqm | 325 | ₹3,250 |
| 1.06 | Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as required complete in all respect. . | 200 | Kg | 114 | ₹22,800 |
| 1.07 | SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation from 50 to 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle ( to be paid extra) , including making connections etc. as required. OEM shall have submit NABL / CPRI / ERDA/ Intertek accrediated lab type test certificate. | - | - | - | - |
| 1.08 | 4 pole MCCB With Thermal Magnetic release | - | - | - | - |
| 1.09 | up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting | 2 | Each | 1,932 | ₹3,864 |
| 1.1 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanism , energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. | - | - | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.76 MB
Tendernotice_2.pdf
PDF • 21.17 MB
Cover3.pdf
Tender Documents • 0.42 MB
BOQ_1042600.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .