Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.4 LAccepted-AOC | ₹43.4 L Quoted ₹44.0 L | L1 | Accepted-AOC BEING LOWEST BIDDER |
| 2 | L2₹45.0 LRejected-AOC | ₹45.0 L | L2 | Rejected-AOC OTHER THAN LOWEST BIDDER |
| 3 | L3₹47.3 LRejected-AOC NEW ABADI KISHANPURA SURATGARH 335804 DISTT SRIGANGANGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | ₹47.3 L | L3 | Rejected-AOC OTHER THAN LOWEST BIDDER |
| 4 | L4₹48.5 LRejected-AOC WARD NO 02 LAKHUWALI PO THE PILIBANGAN DISTT HANUMANGARH RAJASTHAN 335803 | HANUMANGARH | RAJASTHAN | 335803 | ₹48.5 L | L4 | Rejected-AOC OTHER THAN LOWEST BIDDER |
| 5 | L5₹50.3 LRejected-AOC | ₹50.3 L | L5 | Rejected-AOC OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | M/s JUGAL KISHORE MISHRA AND SONS L3 | PACHAR BROTHERS L5 | S.K BUILDERS AND ENGINEERS L2 | Gill Construction Co L4 | BISHNOI BUILDERS L1 |
|---|---|---|---|---|---|---|---|---|
| .10Notes:- (i) 100 percent nonperishable items of the work shall be deposited by the L1 bidder within 30 days after placing of work order. (ii) The critical path network shall be submitted by L1 bidder immediately after the acceptance of tender and approved by GE. (iii) The bidders must ensure to visit the site, check relevant documents and makes of materials required to be incorporated under the subject from concern Engineer-in-Charge. (iv) The unserviceable material obtained under the schedule of credit shall be handed over to the contractor by the Engineer-in-Charge on a proper gate pass. (v) In case of non-availability of any make mentioned under list of Makes, the L1 Bidder shall obtain non-availability / non-manufacturing certificate from the concern authorised dealers and submitted to Accepting OfficerIn such cases the L1 bidder shall be incorporated makes as approved by HQ CE SWC Jaipur (Group X) in the works after prior approval of Accepting Officer. (vi) L1 Bidder shall produce E-way bill alongwith test certificate from OEM / manufacturer for costly items / major items of amount above Rs 50,000/- along with RAR’s and Final Bill. (vii) L1 Bidder shall be maintained an album containing Photos of all the material brought at site and each stage wise work progress and kept at site. Same shall be deposited in Engineer-in-Charge office after completion of work. (viii) The cost of all the above provisions shall be deemed to be included in the quoted rate of bidder, nothing extra shall be paid to the bidder. | ||||||||
| 1.00 | Demolition of Brickwork or stone/boulder masonry, built in CM or cement lime mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework & precast concrete articles complete all as specified and as directed. | 5 | Cum | 100 ₹500 | 300 ₹1,500 | 200 ₹1,000 | 150 ₹750 | 100 ₹500 |
| 2.00 | M&L for brick work with sub class fly ash bricks, straight or curved on plan exc 6m mean radius built in, built in CM 1:6 complete all as specified and directed . | 45 | Cum | 4,600 ₹2.1 L | 4,200 ₹1.9 L | 4,000 ₹1.8 L | 4,120 ₹1.9 L | 4,100 ₹1.8 L |
| 3.00 | M&L for brickwork with fly ash bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4) complete all as specified and as directed. | 10 | Sqm | 400 ₹4,000 | 800 ₹8,000 | 500 ₹5,000 | 440 ₹4,400 | 700 ₹7,000 |
| 4.00 | Taking down cement plaster on brick or stone walls or PCC block walling or concrete surface including raking out joints hacking for key scrubbing down with water etc. complete all as specified and as directed. | 800 | Sqm | 20 ₹16,000 | 10 ₹8,000 | 20 ₹16,000 | 15 ₹12,000 | 15 ₹12,000 |
| 5.00 | M&L for rendering 15 mm thick (Average) readymade plaster on inner/outer walls with UltraTech READIPLAST by adding 17-19% of potable water by weight of material. For thickness 15 mm it is recommended to be applied in multiple layers. Ready-mix plaster shall complies with IS 1661-1972, IS 2250-1965, IS 2402-1963 and confirms the Compressive strength @ 28 Days- 10-12 Mpa/ Bulk density- 1500-1600 Kg/m3 complete all as specified and as directed
Note :The rate quoted by contractor shall include cleaning of surface, application as per instruction all as specified and directed)
Make: Equivalent of Ultratech/JK/ Fosroc etc | 450 | Sqm | 520 ₹2.3 L | 400 ₹1.8 L | 320 ₹1.4 L | 540 ₹2.4 L | 377 ₹1.7 L |
| 6.00 | M&L for rendering 10 mm thick readymade plaster on inner/outer walls with UltraTech READIPLAST by adding 17-19% of potable water by weight of material. Ready-mix plaster shall complies with IS 1661-1972, IS 2250-1965, IS 2402-1963 and confirms the Compressive strength @ 28 Days- 10-12 Mpa/ Bulk density- 1500-1600 Kg/m3 complete all as specified and as directed
Note :The rate quoted by contractor shall include cleaning of surface, application as per instruction all as specified and directed)
Make: Equivalent of Ultratech/JK/ Fosroc etc | 650 | Sqm | 520 ₹3.4 L | 400 ₹2.6 L | 320 ₹2.1 L | 530 ₹3.4 L | 350 ₹2.3 L |
| 7.00 | M&L for rendering 5 mm thick readymade plaster on Ceilling/Chajja with UltraTech READIPLAST by adding 17-19% of potable water by weight of material. Ready-mix plaster shall complies with IS 1661-1972, IS 2250-1965, IS 2402-1963 and confirms the Compressive strength @ 28 Days- 10-12 Mpa/ Bulk density- 1500-1600 Kg/m3 complete all as specified and as directed.
Note :The rate quoted by contractor shall include cleaning of surface, application as per instruction all as specified and directed)
Make: Equivalent of Ultratech/JK/ Fosroc etc | 250 | Sqm | 520 ₹1.3 L | 400 ₹1 L | 280 ₹70,000 | 510 ₹1.3 L | 300 ₹75,000 |
| 8.00 | Taking down/dismantiling ceiling plaster, cutting down steel reinforcement in square or rectangular shape, make the surface equal in shape, binding mild steel Xpm wire fabric and splashing the concrete with mix 1:1⅟2:3 using 6mm stone aggregate making the surface level and curing for 6-7 days and ceiling plaster with UltraTech READIPLAST by adding 17-19% of potable water by weight of material. Ready-mix plaster shall complies with IS 1661-1972, IS 2250-1965, IS 2402-1963 and confirms the Compressive strength @ 28 Days- 10-12 Mpa/ Bulk density- 1500-1600 Kg/m3 complete all as specified and as directed
Note :The rate quoted by contractor shall include cleaning of surface, application as per instruction all as specified and directed)
Make: Equivalent of Ultratech/JK/ Fosroc etc | 15 | Sqm | 520 ₹7,800 | 500 ₹7,500 | 400 ₹6,000 | 690 ₹10,350 | 200 ₹3,000 |
| 9.00 | M&L rough cast plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 5mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including srubbing and washing, the top layer with brushes and water to expose the stone chippings.complete all as specified | 100 | Sqm | 320 ₹32,000 | 350 ₹35,000 | 240 ₹24,000 | 210 ₹21,000 | 190 ₹19,000 |
Updated dates
Tender Value
₹48.1 L
EMD Value
₹96,200
Closing Date
10 Nov 2025, 6:00 pmClosed
GE (A) Suratgarh
GE (Army) Suratgarh suratgarh Mil Stn
SPL REPAIR TO BLDG NO P-02 (SINGLE OFFRS ACCN) AND PROVN OF ROOM/STORE FOR DRY AND FRESH RATION IN THE AOR OF AGE B/R-II UNDER GE (ARMY) SURATGARH AT SURATGARH MIL STN
2025_MES_734122_1
GE (A) SOG Token No 41/25-26
Open Tender
Civil Works
180 days
Suratgarh
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (A) Suratgarh
₹96,200
30 Dec 2025
7 Oct 2025
12 Nov 2025
7 Oct 2025
10 Nov 2025
28 Oct 2025
Amount
Demolition of Brickwork or stone/boulder masonry, built in CM or cement lime mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework & precast concrete articles complete all as specified and as directed.
M&L for brick work with sub class fly ash bricks, straight or curved on plan exc 6m mean radius built in, built in CM 1:6 complete all as specified and directed .
M&L for brickwork with fly ash bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4) complete all as specified and as directed.
Taking down cement plaster on brick or stone walls or PCC block walling or concrete surface including raking out joints hacking for key scrubbing down with water etc. complete all as specified and as directed.
M&L for rendering 15 mm thick (Average) readymade plaster on inner/outer walls with UltraTech READIPLAST by adding 17-19% of potable water by weight of material. For thickness 15 mm it is recommended to be applied in multiple layers. Ready-mix plaster shall complies with IS 1661-1972, IS 2250-1965, IS 2402-1963 and confirms the Compressive strength @ 28 Days- 10-12 Mpa/ Bulk density- 1500-1600 Kg/m3 complete all as specified and as directed Note :The rate quoted by contractor shall include cleaning of surface, application as per instruction all as specified and directed) Make: Equivalent of Ultratech/JK/ Fosroc etc
M&L for rendering 10 mm thick readymade plaster on inner/outer walls with UltraTech READIPLAST by adding 17-19% of potable water by weight of material. Ready-mix plaster shall complies with IS 1661-1972, IS 2250-1965, IS 2402-1963 and confirms the Compressive strength @ 28 Days- 10-12 Mpa/ Bulk density- 1500-1600 Kg/m3 complete all as specified and as directed Note :The rate quoted by contractor shall include cleaning of surface, application as per instruction all as specified and directed) Make: Equivalent of Ultratech/JK/ Fosroc etc
M&L for rendering 5 mm thick readymade plaster on Ceilling/Chajja with UltraTech READIPLAST by adding 17-19% of potable water by weight of material. Ready-mix plaster shall complies with IS 1661-1972, IS 2250-1965, IS 2402-1963 and confirms the Compressive strength @ 28 Days- 10-12 Mpa/ Bulk density- 1500-1600 Kg/m3 complete all as specified and as directed. Note :The rate quoted by contractor shall include cleaning of surface, application as per instruction all as specified and directed) Make: Equivalent of Ultratech/JK/ Fosroc etc
Taking down/dismantiling ceiling plaster, cutting down steel reinforcement in square or rectangular shape, make the surface equal in shape, binding mild steel Xpm wire fabric and splashing the concrete with mix 1:1⅟2:3 using 6mm stone aggregate making the surface level and curing for 6-7 days and ceiling plaster with UltraTech READIPLAST by adding 17-19% of potable water by weight of material. Ready-mix plaster shall complies with IS 1661-1972, IS 2250-1965, IS 2402-1963 and confirms the Compressive strength @ 28 Days- 10-12 Mpa/ Bulk density- 1500-1600 Kg/m3 complete all as specified and as directed Note :The rate quoted by contractor shall include cleaning of surface, application as per instruction all as specified and directed) Make: Equivalent of Ultratech/JK/ Fosroc etc
M&L rough cast plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 5mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including srubbing and washing, the top layer with brushes and water to expose the stone chippings.complete all as specified
M&L for preparation of newly decorated, plastered or pointed surfaces of wall and applying two coats of interior emulsion over a 1 mm thick acrylic wall care putty over a coat of pirmer complete all as specified & directed by Engineer-in-Charge. (Make : Tractor Emulsion (Asian Paint), Easy Clean (Berger Paint), Promise Inerior (Dulux Akzonobel)
M&L for complete removal of existing treatment of old decorated, plastered or pointed surfaces of wall by brooming down or steel wire brushing,scrapping down smoke soot moulds, moss and efflorescent, salts and treating oil & greasy spots, washing, rubbing down and stopping of distempered surface, filling of cracks etc and applying two coat of interior emulsion over a coat of primer over 1 mm thick acrylic wall care putty complete all as specified & directed by Engineer-in-Charge. (Make : Tractor Emulsion (Asian Paint), Easy Clean (Berger Paint), Promise Inerior (Dulux Akzonobel)
M&L for preparation of newly decorated, plastered or pointed surfaces of ceilling and applying two coats of interior emulsion over a 1 mm thick acrylic wall care putty over a coat of pirmer complete all as specified & directed by Engineer-in-Charge. (Make : Tractor Emulsion (Asian Paint), Easy Clean (Berger Paint), Promise Inerior (Dulux Akzonobel)
M&L for complete removal of existing treatment of old decorated, plastered or pointed surfaces of cilling by brooming down or steel wire brushing,scrapping down smoke soot moulds, moss and efflorescent, salts and treating oil & greasy spots, washing, rubbing down and stopping of distempered surface, filling of cracks etc and applying two coat of interior emulsion over over a coat of primer over 1 mm thick acrylic wall care putty complete all as specified & directed by Engineer-in-Charge. (Make : Tractor Emulsion (Asian Paint), Easy Clean (Berger Paint), Promise Inerior (Dulux Akzonobel)
Material & Labour of newly plastered for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed by Engineer-in-Charge. (Make :- Apex Ultima (Asian Paint), Weather Coat anti dust ( Berger Paint ), Excel No Dust ( Nerolac)
M&L for complete removal of existing treatment of old decorated, plastered or pointed surfaces of wall and applying two coats of 100% Premium exterior emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including one priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed by Engineer-in-Charge (Make :- Apex Ultima (Asian Paint), WeatherCoat anti dust ( Berger Paint ), Excel No Dust ( Nerolac)
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M&L 25 mm thick PCC type B-0, (1:2:4) using 12.50 mm graded stone aggregate complete all as specified and as directed by Engineer-in-Charge
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for non skid joint free ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors over & including 15mm thick screed bed in cement & sand mortar 1:6, to receive floor and fixed with appropriate adhesive conforming to IS15477-2019 type 1 complete all as specified and directed.
M&L for glazed ceramic tiles (coloured) 10mm thick (square/rectangular) (Shade & pattern as approved by GE) area of each tile not exceeding 0.72 sqm as dado, skirting etc., including 10mm thick rendering on brick wall in cement & sand mortar 1:4, fixed with appropriate adhesive conforming to IS 15477-2019 type 2 complete all as specified and directed.
M&L for Double charged vitrified tiles 10mm thick (square/rectangular), polished, coloured (Shade & pattern as approved by GE), area of each tile not exceeding 0.72 sqm, in floors etc, including 15mm thick screed bed in cement & sand mortar 1:6, to receive floor and fixed with appropriate adhesive conforming to IS15477-2019 type 1 and using 5mm spacer filled with epoxy resin colour as approved by GE including complete all as specified and directed.
M&L for Double charged vitrified tiles 10mm thick (square/rectangular), polished, coloured (shade as approved), area of each tile not exceeding 0.72 sqm, on vertical surfaces such as dado, skirting etc., including 10mm thick rendering in cement & sand mortar 1:4 fixed with appropriate adhesive conforming to IS 15477-2019 type 2 complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer-in-charge.
S&F mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, cooler stand 12mm sq guard bar, framework of water tanks and similar works of quality Fe 290 (Gde E-165) etc complete all as specified and directed by Engineer-in-charge.
Material & Labour for 18 gauge stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed by Engineer-in-Charge. Make:-Jindal or Techo commercial equvalent
Material & Labour 18 gauge stainless steel (Grade 304) fancy type Modern style (shape/size/design as directed by Engr-in-charge ) railing main pillar including welding, grinding, buffing, polishing (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed by Engineer-in-Charge.
Taking down old rusted & damaged steel windows/ventilators of any description and of any type & size with guard bars / grill including cutting holes for hold fasts & making good the disturbed portion complete all as specified & as directed.
Supply and fixing factory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multi chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. Note :- (i) Toughened Glass or wiremesh shall paid separately Note:(ii) For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
Providing and fixing factory made uPVC white colour casement (Openable) window made of extruded profiles with wall thickness of 2.3mm ( + – 0.2mm). Window profile with hollow section with multi chamber, frame (60mm x 58mm), sash (60mm x 73mm), T profile (One vertical length in between two shutters) (60mm x 74mm), Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 +– 0.2mm thick, galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27.5mm). T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100mm long fasteners. Hardware: [casement handle made of zinc alloyed (white powder coated), But Hinges of'zinc alloyed (white powder coated), transmission gear made of mild steel with multi point locking system] . Note (i) : - Glass shall be measured and paid seperately. (ii) The unit rate quoted by contractor is includes all other connected accessories. Net opening will be measured for payment purpose.)
Supply and fixing factory made uPVC white colour fixed/ openable casement glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Note (i) : - Glass shall be measured and paid seperately. Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
Taking down chowkhats or frames not exc 1.5 sq. m each with shutters (without taking off shutters from the frames) complete all as specified and as directed.
Taking down chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each with shutters (without taking off shutters from the frames) complete all as specified and as directed.
Dismantling of boarding, any description fixed in any position with nails complete all as specified and directed by Engineer-in-charge.
M&L for Factory made double extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 125x65mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). including dismantling existing wooden/iron/stone chowkhats complete and making good existing disturbed surface with cement and sand mortar 1:3 complete all as specified.
S&F 30 mm thick factory made flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both side complete all as specified and directed by Engineer-In-Charge.
S&F 1.00 mm thick Decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions® complete all as specified and directed by Engineer-In-Charge.
M&L for brass mortice lock set with handles 175mm and 6 lever locking mechanism complete all as specified and directed by Engineer-in-charge.
S&F 35 mm thick factory made 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., (without sash bar), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part-I complete all as specified and directed by Engineer-in-Charge.
S&F strain less steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvnaied wire staple complete all as specified and directed by Engineer-In-Charge.
M&L for preparation of new wooden surfaces of any description, not otherwise described over 10 cm width or gith with two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-Charge
M&L for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 45x90 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). including dismantling existing wooden/iron/stone chowkhats complete and making good existing disturbed surface with cement and sand mortar 1:3 complete all as specified.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw with drawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.
Stainless steel (304 Grade) finished sliding bold 300 mm and 16 mm dia as per BIS clause (iii) of BIS 15834-2020.
Stainless steel (304 Grade) Finished Floor door stopper-140mm as per direction of Engineer-In-Charge
Stainless steel (304 Grade) Finished Handles 200 mm as per direction of Engineer-In-Charge
Stainless steel (304 Grade) Finished Handles 150 mm as per direction of Engineer-In-Charge
Stainless steel (304 Grade) Finished Handles 100 mm as per direction of Engineer-In-Charge
Stainless steel (304 Grade) finished square tower bold 200 mm long- dia of bolt 12 mm as per BIS 12833.
Stainless steel (304 Grade) finished square tower bold 150 mm long- dia of bolt 12 mm as per BIS 12833.
Stainless steel (304 Grade) finished butt Hinges 100 mm, table 6 of BIS 12817-2020 BIS Marked.
S&F 5mm thick Sheet glass, ordinary quality and fixed with clip and gasket rubber in square exc 0.5 sq. m in each pane complete all as specified and as directed by Engineer-in-Charge.
S&F 5mm Figured glass, pin head type and fixed with clip and gasket rubber in squares n exc 0.5 sq. m in each pane complete all as specified and as directed by Engineer-in-Charge.
Water proofing treatment to sunken slab and adjjoining vertical surfaces as specified under :- (a) Demolition of cement concrete in sunken portion. (b) Preparation sunken surfaces by cleaning of and removal of loose concrete (c) Filling cracks with polymer modified mortar using Dr. Fixit Pidicrete URP or equivalent in Forsoc and other approved make (d) Applying 2 coats of Dr. Fixit Bath seal WPC in suken areas and laying a protective plaster in 10mm thickness in cement mortar (1:3) admixed with Dr. Fixit Pidicrete LW + @ 220ML per bag of cement (e) Applying mix of of DR FIXIT PIDICRETE URP in the ratio 1:1:5 on floor and vertical surface of sunken portion as per manufacturers instructions complete (f) Filling with Autoclaved aerated concrete (ACC) block materials made from flyash, sand, lime, cement , gupsum, water and expeanding agents exc 10cm in width and setting in block jointing 3mm layer adhesive complete all as specified and directed by Engineer-in-charge Note: The plan area of floor shall be considered for payment.
Supply & fixing in repair vitreous china premium / 1st quality wash down water closet wall hung EWC white/ivory/off white (closed pattern) incl all necessary accessories like rag bolts / gel gasket etc (excluding flushing cistern and flush pipe) and also included all the necessary fillting of PVC pipe up to 1st MH of bldg complete all as specified and as directed. Make Jaquar Opal Prime Or Equivalent in Kohler,Grohe
Supply & fixing in repair of concealed cistern set size 500X90X460 mm with full frame incl accessories incl in chevron cistern with full frame bend discharge pipe 'S' 110 mm , straight discharge pipe 'P' 90 mm ,adapter sleeve ,protection cap cover and incl of actuator knob for chevron cistern and also included all the necessary fillting complete all as specified and as directed Make Jaquar Opal Prime Or Equivalent in Kohler,Grohe
S&F mild steel 300mm, oridinary rat tail rod pattern springs including roller & roller plate fixed to wooden frame or welded to steel frame complete all as specified and directed by Engineer-In-Charge.
S&F as in repair brass WHB high CP mixer for mixing hot & cold water screwed down for iron pipe complete all as specified and as directed by Engineer-in-Charge.
S&F for Factory made single extruded WPC (Wood Polymer Composite) solid decorative flush door shutter/Cupboard shutter of 24 mm thick size comprising of virgin polymer of K value 57-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and nontoxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 550 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.
Supply and fixing Magnetic catcher fixed with steel screw complete all as specified and as directed by Engineer-in-charge.
Supply & fixing Continuous (piano) hinges, stainless steel, bright finish, width of flap when open 30mm complete all as specified and as directed by Engineer-in-charge .
S & F as in repair Jet spray, CP, brass body with wall hook and 1 mtr SS pipe complete all as specified
S & F as in repairs 20mm bore, gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified
S&F as in repairs Health faucets of made of stainless steel connected for EWC complete all as specified and as directed Make :- Jaquar Cat Part No "ALD-CHR-573", Kohler Cat Part No "K-98100IN-CP",
S&F as in repairs Angle Stop valves 15 mm bore fancy type, CP, cast copper alloy screwed down high presure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions Make: Jaquar Cat Part No "FUS-CHR-29053", Kohler Cat part No "76390IN-9-CP"
S&F as in repairs PVC connection 15mm dia with PTMT nut of length 600 mm long complete all as specified and as directed.
S&F of cPVC pipe SDR 11 grade outer dia 20mm bore with all necessary cpvc brass fittings and fixed complete to walls and ceiling or laid in floors incl taking down exisitng old unserviceable tubing of any description complete all as specified and as directed.
S&F of cPVC pipe SDR 11 grade outer dia 25 mm bore with all necessary cpvc brass fittings and fixed complete to walls and ceiling or laid in floors incl taking down exisitng old unserviceable tubing of any description complete all as specified and as directed.
Dismantling water tanks of capacity exc 500 litres but n exc 1000 litres and removing to store complete all as specified and as directed.
Supply and fixing of 1000 Litre capacity 4 layer antimicrobial tank of hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe and 20mm PTMT float valve etc. complete as specified and as directed.
S&F vitreous china counter type wash basin of size 550 x 400 mm over granite slab including 15mm bore 450mm length PVC Connection, 32mm bore chromium plated waste coupling etc all as specified and directed by Engineer-in-Charge
S&F PVC solid wall lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specification and as shown in relevant drawing of item 08113 to 08115 on Page No 162 of MES Sch Part -II (2010) complete all as specified and directed by Engineer-in-Charge.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed by Engineer-in-Charge.
M&L for 16 to 18mm thick Granite (Rajasthan black) slab of approved shade as in flooring, platform etc, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match with shade of Granite stone including cutting, grinding over & including 15mm thick screed bed (bedding layer) in CM (1:6) complete all as specified and directed by Engineer-in-charge. Note:- Rate of rounding as Bull nose rounding of granite included in the above rate nothing to be extra paid.
M&L for 16 to 18mm thick leather finish Granite (Rajasthan black) slab of approved shade as in steps and skirtting etc, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match with shade of Granite stone including cutting, grinding over & including 15mm thick screed bed (bedding layer) in CM (1:6) complete all as specified and directed by Engineer-in-charge. Note:- Rate of rounding as Bull nose rounding of step included in the above rate nothing to be extra paid.
S&F as in repair grating doom 100mm dia of PTMT (Minimum weight 25 gms) complete all as specified and as directed.
S & F as in repair brass chromium plated bottle trap with 32mm dia discharge pipe having minimum water seal or 25mm for wash basin with inlet and outlet screwed for pipe or connections including necessary packing , union and cap complete all as specified & directed by Engineer-in-charge. Make :- Cera cat part No F8060101 / Somani cat part No 2721500540411 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F in repairs CP brass tubular towel rail 20mm dia D Type 60cm long between flanges and fixed with SS 304 grade screw/fastners complete all as specified and directed by Engineer-in-charge.
S&F in repairs SS finish 160mm dia towel ring and fixed with SS 304 grade screw/fastners complete all as specified and directed by Engineer-in-charge.
S&F Stainless steel fancy type peg set of six and fixed in position with steel screws complete all as specified and directed.
S&F chromium plated SS soap dish and fixed to plugs on wall with chromium plated brass screws complete all as specified and as directed by Engineer-in-Charge.
S&F chromium plated toilet paper holder with flap type and fixed to plugs on wall with chromium plated brass screws complete all as specified and as directed by Engineer-in-Charge.
S&F chromium plated 18cm wall mount framed extendable detailing mirror (360 Degree movable) and fixed to plugs on wall with chromium plated brass screws complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair PVC bathroom cabinet mirror of size 450x350mm all as specified and directed by Engineer -in-charge
S&F chromium plated brass Towel rack with lower hanger and fixed to plugs on wall with chromium plated brass screws complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair Glass corner of 8.0mm thick sheet glass 25 cm wide with chromium plated steel railing complete.
Dismantling of cast iron drain pipe of 100mm dia, jointed in CM and taking out from trenches/walls, if required complete all as specified.
Demolition and breaking up drain pipes 100mm dia (PVC pipe, Salt glazed ware, AC or Reinforced concrete) set in cement mortar
Supply and fixing PVC (SWR) bends/Tee/etc any radius bore 110 mm complete all as specified and as directed
S&F PVC (SWR) pipes bore 110 mm single socketed, in any length with rubber ring joints, laid in trenches complete all as specified and as directed
S&F PVC (SWR) pipes bore 110 mm single socketed, in any length with rubber ring joints, in wall complete all as specified and as directed
S&F for Pipe Supporting Clamping - Single Pipe of dia 110 mm (4") down take pipe fixing done with Clamping System consists of Profile Bracket + Continuous Slotted C Channel + U Bolt Rubber Sleeve mounted System running vertically with wall distance 75 mm (3"): Pipe Support Clamping made of : 1. Profile Bracket having Wall Distance 75 mm (3") made of Low Carbon Hot Roll Gauge Corrected Oil Pickled and Drawn (HROP D) Steel (IS 1079); material size 32 mm x 3 mm with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result 2000 hrs with SS304 Hex Flange Bolt with Serration 5/16 x 3/4 (A/F 13mm) as per DIN 6921and SS304 Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration as per DIN 6923. 2. Continuous Slotted "C" Channel with ribs to be used of size 250 mm (10") made of Low Carbon Hot Roll Gauge Corrected Oil Pickled and Drawn (HROP D) Steel (IS 1079) are Hot Dip Galvanzied + Zn Al Flake coated with material thickness of 3mm. 3. U bolt Rubber Sleeve mounted are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing semi transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing: As per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 used as per MTC confirms to EN 10204 3.1.Material Qty. for one unit : 1. Profile Bracket Wall distance 75 mm (3") - 2 Nos. 2. Continuous Slotted C Channel of Size 250 mm (10") - 1 No.; 3. U Bolt Rubber sleeve mounted for 110 mm (4") CI or PVC Pipe Dia. - 1 No.; and 4. Fixing Nail Zn coated of thickness 6.5 mm and length 63 mm (2 1/2") - 4 nos. Fixing Details: Pipe Support Clamping Unit to be fixed at every metre distance in the duct as specified in Chief Engineer Bathinda Zone Technical Drawing (TD) of Factory Made Pipe Supporting System : DRG NO.- BTD-916. Make: Shaivi or equivalent as approved by GE.
Supply only water proofing compound complete all as specified and as directed
Dismantling of brick tiles or terracing tiles single layer on roof & disposal of retrieved material upto a distance n.exc 100m where directed, all as specified.
Demolition of mud in roof, any thickness including plastering and leaping (where full thickness removed or only a part there of disposal off rubbish upto a distance n.exc 100m, where directed.
M&L for rendering 15 mm thick in cement plaster 1:4 with WPC on roof, fair faces of brick work or concrete surfaces all as specified and directed by Engr -in - charge. Note : WPC will be measured and paid separately
M&L PCC 1:2:4 type B0 (using 12.5 mm graded aggregate) in roof complete all as specified and directed
M&L for Roof Treatment in as specified below and as directed : (a) Cleaning, washing of surface and removing any debris, Surface should be free from any loose paint, dust or grease. (b) Applying one coat of Elastomeric PU Based liquid membrane diluted with potable water in the ratio of 1:1 and apply @ 0.40 kg/ sqm. (c) Laying polyster reinforced fiber net/150 gsm Geotextile mesh, upto 300 mm on walls. (d) Applying two coats of undiluted PU Based liquid membrane, having Elongation more than 400%, Tensile Strength more than 2 N/mm2 and alkali & fungal resistant maintaining thickness of 1.5mm, with paint brush/ roller upto 300 mm on walls. (e) The complete treatment to be carried out by authorised applicator of waterproofing manufacturer. Note : (i) The treatment shall be carried out as per the manufacturers instructions, and as directed by Engineer in Charge. (ii) The plan area of floor shall be considered for payment .
Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and as directed
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick complete all as specified and as directed
TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specifed and as directed
All as per serial item No 102 here-in-before but 5mm dia and over up to and including 10mm dia as in stirrups, spacers & binder etc complete all as specified and directed.
M&L for reinforced cement concrete 1:2:4 type B1 ( using 20 mm graded aggregate) for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed
M&L for reinforced cement concrete (1:2:4) type B-1(using 20 mm graded crushed stone aggregate) as in beams , cantilever, bressummer, lintel over 1.5m span and similar work complete all as specified and directed by Engineer-in-Charge
M&L for use and waste of form work to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified and as directed by Engineer-in-charge.
M&L for 75 mm thick 1:3:6 PCC type C1 finished even and smooth laid to slope of 1 in 20, laid in alternate bays, each bay not exceeding 2.5 m length withh joint to be 10 mm groove at junction of wall aand plinth protection filled with filled with bituminous sealing compound of grade A/ Bituminous Mastic filler/sealant,
M&L for preparation new steel surface of any description and applying two coats of synthetic enamel paint over a coat of red oxide primer on new steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth complete all as specified and directed by Engineer-In-Charge.
M&L for 75 mm thick PCC (1:4:8) using 40 mm graded stone aggregate as in sub base of floor finishes complete all as secified and directed.
M&L for Machine pressed precast rubberised conctete interlocking paver block shape and size approved by GE and confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and with pigment complete all as specified and directed by EIC.
M&L for tibba sand/red bajri filling under floors or in foundations including watering and consolidation complete all as secified and directed.
M&L for providing cement concrete type B-0,1:2:4 ( 12.50 mm graded aggregate ) as in packing of interlocking tiles complete all as directed.
M&L as in repair for 25mm dia stainless steel pipe curtain rod with steel brackets and steel knobs at both ends as per site requirement including taking down old existing PVC conduit pipes with accessories complete all as specified
Surface excavation avg 15cm deep and not exceeding 30cm deep and getting out in soft/ loose soil complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil & getting out complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance not exc 50m and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation, filling & mass concrete complete all as specified and directed by Engineer-in-charge .
M&L for hardcore of broken stone / boulders gauge not exc. 63mm, deposited, spread and levelled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-charge.
M&L for cement concrete (1:2:4) type B1 using 20 mm graded crushed stone aggregate as in surface channels and drains and benching including finishing the top of benching even and smooth using extra cement complete all as specified and directed by Engineer-in-charge. Note : Forming fair finished channel for drain using extra cement shall be measured and paid for separately.
M&L for 10mm thick rendering in cement mortar (1:6) on fair face surface of brick masonary or concrete surface of walls, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for 15mm thick rendering in cement mortar (1:4) on fair face surface of brick masonary or concrete surface of walls, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
S&F Anodised aluminium frame powder coating (minimum thickness of powder coating 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge.
S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge.
M&L for Continuous brick edging with sub class B brick; with width equal to the depth of the brick, laid dry, on edge complete all as specified and as directed.
M&L for steel work as in tubular trusses, purlins, post including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St.-240 including painted with one shop coat of zinc chromate primer paint including preparation of surface at contractor workshop before fabrication complete all as specified and directed by Engineer-i
M & L for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment etc conforming to Fe-290 (Gde E- 165, complete all as specified & directed by Engineer-in-charge.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of 35mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw with drawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.
M&L for Ceramic tiles 8-9 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc, including 15mm thick screed bed in cement & sand mortar 1:6, to receive floor and fixed with appropriate adhesive conforming to IS15477-2019 type 1 and using 5mm spacer filled with epoxy resin colour as approved by GE including complete all as specified and directed.
M&L for Ceramic tiles 8-9 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36, on vertical surfaces such as dado, skirting etc., including 10mm thick rendering in cement & sand mortar 1:4 fixed with appropriate adhesive conforming to IS 15477-2019 type 2 including dismantling of old tiles complete all as specified and directed.
S&F DWCPE (SN8) pipe 160 (outer) /136 (inner) mm dia as per IS-16098 (Part-II) laid in trenches or in floor on moorum bed to required shape including all necessary accessories / fitting / jointing / rings, joiting and testing complete all as specified & directed by Engineer-in-charge.
M&L for cutting into existing manhole/Septic tank/Soak well for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B1, smooth finished and reforming benching as required for 150/200/250 mm bore pipe complete all as specified and directed by Engineer-in-charge.
Material & labour construction of Soak Well for 10 to 25 users as shown on drawing No.GE(A) /comp / 17 / 2016 complete all as specified and as directed by Engineer-in-charge. Notes : Irrespective to whether shown on drawing or not, excavation & earthwork shall be in any type of soil, brick work shall be in CM 1:4, over burnt brick bats shall be used for filling, PCC 1:4:8 type D2 using 40mm graded stone aggregate shall be provided in foundation, 20mm dia MS rungs made to shape painted with two coats of bituminous paint shall be provided, PCC 1:3:6 type C2 using 40mm graded stone aggregate shall be provided in plinth protection, 1.50m long 150mm bore cast iron sand cast inlet pipe shall be provided and slab shall be Precast RCC (1:2:4). Other details shall be as shown on drawings & as specified in particular specifications.
M&L for construction of Septic Tank for 50 users as shown on drawing No. BTD-016 sheet No. 1/3 to 3/3 complete all as specified and as directed by Engineer-in-charge. Notes : Irrespective to whether shown on drawing or not, excavation & earthwork shall be in any type of soil, RCC in foundation shall be M-20 (Nominal Mix) over lean concrete (1:3:6) using 40mm graded stone aggregate over brick hard core, all PCC shall be M-20 (Nominal Mix) using 20mm graded stone aggregate, all RCC work shall be M-20 (Nominal Mix), brick work shall be in CM 1:4, 20mm dia MS rungs made to shape painted with two coats of bituminous paint shall be provided. Other details shall be as shown on drawings & as specified in particular specifications.
Taking down carefully or drawn out from conduit, existing copper / aluminium point wiring for light, fan, bell, socket, power point etc complete including fixture and fittings such as switches, sockets, ceiling rose, pendent holder, light fittings, top sheet covers, fan regulators, MCB, DB, lamp, earth plug etc (excluding MS sunken boxes) and making good the disturbed surfaces of wall/ceiling complete all as specified and as directed by Engineer-in-charge.
All as per serial item No. 138 here-in-before but for One 3 pin 5 Amp socket outlet one light point controlled by one switch on the same board with other switches.
All as per serial item No. 138 here-in-before but for One 3 pin 5 Amp socket outlet one light point controlled by one switch on independent board.
All as per serial item No. 138 here-in-before but for One light point controlled by Two 2- way switches.
All as per serial item No. 138 here-in-before but for One bell or buzzer point controlled by by one push button on independent board.
All as per Srl item No. 138 above, but wiring with cable of cross sectional area 4 Sqmm (nominal area) multi-stranded copper conductor FRLSH, PVC sheathed cable 1100 Volts shade for one switch socket combination 6 pin, 5/15 Amps on independent board including 4 Sqmm PVC insulated multistranded unsheathed copper conductor wire as earth continuity to common earth dolly.
S&F Modular switch piano 6 Amps single pole, one way, 01 Module complete all as specified and directed by Engineer-in-charge.
S&F Modular switch piano 6 Amps single pole, two way, 01 Module complete all as specified and directed by Engineer-in-charge.
S&F Modular switch piano 15/16 Amps single pole, one way, 01 Module complete all as specified and directed by Engineer-in-charge.
S&F Modular socket 2 / 3 pin, 6 Amps, 230 volts, combined 2 Module complete all as specified and directed by Engineer-in-charge.
S&F Modular bell push, flush type, 5 Amp, 230 Volts grade complete all as specified and directed by Engineer-in-charge.
S&F Modular socket outlet 2/3 pin 06/16A, 6 pin,2 module, 230 Volts grade complete all as specified and directed by Engineer-in-charge.
S&F Modular electronic fan regulator suitable for ceiling fan 2 Module, 1200mm / 1400mm sweep, socket size, rotary type complete all as specified and directed by Engineer-in-charge.
S&F ceiling rose surface bakelite 65mmx50mm with two or three terminal complete all as specified and directed by Engineer-in-charge.
S&F electric bell (ding - dong), AC, 230 Volts, Single pole & connecting up complete all as specified and directed by Engineer-in-charge.
S&F Energy efficient decorative ultra slim, prewired, lumiline 20 watt LED light fitting (Day cool light), batten type with drive & polycarbonate housing including tube rod and all accessories prewired fixed on wall / hanging complete all as specified and as directed by Engineer-in-charge. Make : Havells Cat Part No.:- LHEXAZP7PN1W020/Crompton Cat Part CCS-103-20-65-SL-DP-NWH/Wipro Cat Part D532065 or equivalent cat part of Make as specified in Appendix "A".
S&F Energy efficient decorative ultra slim, prewired, lumiline 10 watt LED light fitting (Day cool light), batten type with drive & polycarbonate housing including tube rod and all accessories prewired fixed on wall / hanging complete all as specified and as directed by Engineer-in-charge. Make : Havells Cat Part No.:- LHEXAZP7PN1W010/Crompton Cat Part CCS-103-10-65-SL-DP-NWH/Wipro Cat Part D531065 or equivalent cat part of Make as specified in Appendix "A".
Supply, fixing and testing in repair LED Street / Security light fitting of 30 Watt, 5700K - 6500 K (including LED drive and internally prewired) complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminum alloy. The luminaries shall be monolithic construction totally enclosed dust and water proof with IP -65 / 66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 300 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distortion THD(I) less than 15% ,cool white colour and lamp starting time should not be more than 10 second including 10 KV surge protection in built or external. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection, no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degree Centigrade to 50 degree Centigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 100 lumens per watt and must be certified by the LM-79 test report and including connection for street light from pole box with 1.5 Sqmm, 3 core PVC insulated stranded copper conductor FRLSH cable, 1100 Volts grade ISI marked including addition / alteration in bracket (if required) for fixing light fitting complete all as specified and directed by Engineer-in- charge.
S&F as in repair flush mounting factory made SPN DB 8 way, 240 Volt, Double door, IP-43 protection, IK-09 with metal door with 100 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge.
S&F MCB 6 to 32 Amps, Single Pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge.
S&F as in repair MCB 40-63 Amps, SPN, 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge.
S&F Lamp holder, insulated body with back plate etc complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement Sub main wiring complete with 2 single core 6 Sqmm (Nominal area) multi stranded copper conductor PVC insulated unsheathed cable FRLSH drawn in and including heavy duty PVC conduit ISI marked not less than 25mm dia concealed including single core multistranded copper conductor 6 Sqmm size cable as earth continuous wire drawn in same conduit complete all as specified and directed by Engineer-in- charge Note : Two runs of 6 Sqmm single core cable and one run of 6 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
S&F as in repair street light bracket made out of 32mm dia GI pipe light grade 1.20m long , bent to shape at 120 degree angle from vertical fixed along pole with and dirlling holes including required number of clamp made out of Flat iron 25mm x 6mm with nuts, bolts ,washers etc. duly painted with two coats of aluminium paint including any addition / alteration (if required) for fixing street light complete all as specified and as directed by Engineer-in-charge.
S&F as in repair sheet metal plug & socket DB, SP, with a two pin and earth plug with socket, 230 Volts with & including one MCB SP ‘C’ Curve 10 kA, 20 Amps complete all as specified and directed by Engineer-in-charge.
S&F in replacement MCCB 4 Pole 120 Amps, thermal magnetic release having, breaking capacity 16 KA, 415 Volt in the existing feeder pillar box including any addition / alteration to the panel to accommodate the new MCCB & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work, metal work for fixing base plate etc and connections complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED lamp minimum 3 star rated 10W LED B-22 base complete all as specified and directed by Engr-in-Charge with following specifications (a) Lumen system efficacy of lamp should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.90 (e) CRI : Morethan 80
S&F HDPE DWC pipe inner dia 50mm and outer dia 63mm for laying in cable laid in trenches complete all as specified and as directed
S&F as in repair flush mounting factory made VTPN DB 4 way, 415 Volt, Double door, IP-43 protection, IK-09 with metal door with 200 Amps copper bus bar, with 02 neutral bar, 02 earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge.
S&F ceilling fan copper wound complete with blade, down rod, electronic regulator and accessories AC, 230 V, 50 Hz, 1200mm sweep, min air delievery 210 CFM with serving value 6.00 BEE, with Brush less direct current motor (BLDC) complete all as specified and directed by Engineer-in-charge. Note :- MES No with stencil shall be marked on ceiling fan body using synthetic enamal paint. Cost of the same is included in the unit rate of this item.
S&F flush mounting factory made SPN DB 4 way, 240 Volt, Single door, IP-43 protection, IK-09 with metal door with 200 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge.
S&F as in repair Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25x3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and as directed by Engineer-in-charge. Notes :- (i) Excavation & earthwork shall be measured & paid for separately under respective items of BOQ (ii) Cost of flat iron clamp if required is included in the unit rate of this item. Nothing extra shall be paid on this account
S.K BUILDERS AND ENGINEERS (BID ID -3470605)
M/s JUGAL KISHORE MISHRA AND SONS (BID ID -3466079)
Gill Construction Co (BID ID -3471294)
PACHAR BROTHERS (BID ID -3470528)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
BOQ_822017.xls
BOQ • 0.44 MB
tender41.pdf
Tender Documents • 1.39 MB
Download all tender documents and submit your bid