Tender Value
₹5.8 L
EMD Value
₹11,531
Closing Date
30 May 2026, 3:00 pmClosed
EE(E)/ELD-13/DDA
Executive Engineer (E), ELD-13/DDA, Near Hasanpur Bus Depot. Delhi. 110092
Restoration of damaged and defunct Solar Infrastructures at various sites of Yamuna flood plain area.
2026_DDA_910026_1
09/EE/ELD-13/DDA/2026-27 (SPLZ)
Open Tender
Electrical Works
Percentage
30 days
As per NIT documents.
Please refer Tender documents.
16 documents required · 16 mandatory
₹0
₹11,531
4 Jul 2026
23 May 2026
1 Jun 2026
23 May 2026
30 May 2026
23 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Cleaning, refurbishing, and restoration of 12 KWp Solar Power Plant with following works:
Inspection of solar modules after flood exposure, insulation resistance testing, identification of damaged modules, and minor corrective actions, complete as required.
Cleaning of solar PV modules using approved methods to remove silt, mud, and debris deposited due to flood water, including use of soft brushes, demineralized water.
Replacement of minor damaged parts such as connectors, junction box covers, cables, MC4 connectors, module clamps, earthing lugs, fasteners, and other associated hardware affected due to flood water, including supply, installation, and testing.
Supply and replacement of Variable Frequency Drive (VFD) damaged due to flood water, including dismantling of existing unit, mounting, wiring, parameter setting, and integration with existing system.
Electrical reconnection works after replacement/refurbishment, including DC and AC cable terminations, tightening, dressing, ferruling, and earthing continuity checks.
Testing and commissioning of refurbished and replaced equipment including insulation resistance test, continuity test, functional testing, performance verification, and trial run of the solar plant, complete as required. | 1 | Job | 60,210 | ₹60,210 |
| 2 | Cleaning, refurbishing, and restoration of 8 KWp Solar Power Plant with following works:
Inspection of solar modules after flood exposure, insulation resistance testing, identification of damaged modules, and minor corrective actions, complete as required.
Cleaning of solar PV modules using approved methods to remove silt, mud, and debris deposited due to flood water, including use of soft brushes, demineralized water.
Replacement of minor damaged parts such as connectors, junction box covers, cables, MC4 connectors, module clamps, earthing lugs, fasteners, and other associated hardware affected due to flood water, including supply, installation, and testing.
Supply and replacement of Variable Frequency Drive (VFD) damaged due to flood water, including dismantling of existing unit, mounting, wiring, parameter setting, and integration with existing system.
Electrical reconnection works after replacement/refurbishment, including DC and AC cable terminations, tightening, dressing, ferruling, and earthing continuity checks.
Testing and commissioning of refurbished and replaced equipment including insulation resistance test, continuity test, functional testing, performance verification, and trial run of the solar plant, complete as required. | 1 | Job | 41,895 | ₹41,895 |
| 3 | Cleaning, refurbishing, and restoration of 3/4 KWp Solar Power Plant with following works:
Inspection of solar modules after flood exposure, insulation resistance testing, identification of damaged modules, and minor corrective actions, complete as required.
Cleaning of solar PV modules using approved methods to remove silt, mud, and debris deposited due to flood water, including use of soft brushes, demineralized water.
Replacement of minor damaged parts such as connectors, junction box covers, cables, MC4 connectors, module clamps, earthing lugs, fasteners, and other associated hardware affected due to flood water, including supply, installation, and testing.
Supply and replacement of Variable Frequency Drive (VFD) damaged due to flood water, including dismantling of existing unit, mounting, wiring, parameter setting, and integration with existing system.
Electrical reconnection works after replacement/refurbishment, including DC and AC cable terminations, tightening, dressing, ferruling, and earthing continuity checks.
Testing and commissioning of refurbished and replaced equipment including insulation resistance test, continuity test, functional testing, performance verification, and trial run of the solar plant, complete as required. | 2 | Job | 16,875 | ₹33,750 |
| 4 | Supply and replacement of 200 AH, 12 V Inverter Lead Acid Battery with standard warranty of 5 Years i/c functional testing, performance verification etc. complete as required with leass rebate on dismantled material. | 12 | Each | 20,928 | ₹2,51,136 |
| 5 | Supply and replacement of 7.5 KVA/96 V Solar Inverter with standard warranty of 5 Years i/c functional testing, performance verification etc. complete as required with leass rebate on dismantled material. | 1 | Each | 65,420 | ₹65,420 |
| 6 | Supply and replacement of 4 KVA/48 V Solar Inverter with standard warranty of 5 Years i/c functional testing, performance verification etc. complete as required with leass rebate on dismantled material. | 1 | Each | 45,822 | ₹45,822 |
| 7Lifting, Cleaning, Refurbishing & Re-installation of Submersible Pump in Existing Borewell with following works: Lifting of existing submersible pump set from borewell including removal of column pipes, electrical cables, clamps, etc. Cleaning of submersible pump and motor by removal of silt, mud, sand and foreign materials, including washing and inspection. Refurbishing/servicing of submersible pump including checking of bearings, impellers, shaft alignment and motor winding condition. Repairing and replacement of damaged/worn-out pump parts such as impeller, diffuser, shaft sleeve, bearings, oil seal, coupling bolts, etc. Supply and replacement of minor consumables such as nuts, bolts, rubber bushes, gaskets, insulation tape, etc. Lowering and re-installation of refurbished submersible pump to required depth in borewell including fixing of column pipes, electrical cable, clamps, safety rope, etc Electrical connection, insulation resistance testing, trial run, discharge testing and commissioning of submersible pump, complete as required. | |||||
| 7.01 | 7.5 HP | 1 | Job | 22,275 | ₹22,275 |
| 7.02 | 3 HP | 3 | Job | 10,530 | ₹31,590 |
| 7.03 | 2 HP | 1 | Job | 6,885 | ₹6,885 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.15 MB
Tendernotice_2.pdf
PDF • 3.67 MB
BOQ_956441.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .