Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.6 LAccepted-AOC ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹21.2 L+₹1.2 L (5.97%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L2 | Rejected-Finance Being L2 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
22 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Patiala
HQ CWE, Bldg No 26, New Lal Bagh, Patiala - 147001
REPAIR REPLACEMENT OF EXT ELECT LT/HT SUPPLY AND MISC WORK AT MIL STN SANGRUR UNDER GE SOUTH PATIALA
2021_MES_447513_1
8321/PAT/T-19/E8
Open Tender
Electrical and Maintenance Works
Lump-sum
180 days
Sangrur
As per cover 1
6 documents required · 6 mandatory
₹500
Yes
GE South Patiala
₹50,000
Yes
16 Jul 2021
2 Jun 2021
24 Jun 2021
2 Jun 2021
22 Jun 2021
10 Jun 2021
2 Jun 2021 - 7 Jun 2021
60 days
Amount
Schedule 'A'Section-I (External Electrification Work)
Total amount of Sch 'A' Sec I (ExInternal Electrification Works)
Schedule 'A'Section- (MISC EXT ELECTRIFICATION WORKS) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Painting to existing of PCC poles 11/9 Mtr long long with one coat of synthetic enamel paint in alternate strips of black and yelow colours 30 cm height each total 05 Nos commencing form the top of PCC coping incuding painting of coss rms, nut bolts, clamps etc as fixed on pole with tow coats of aluminium paint and marking pole No with paint as per approved pattern, complete all specified (Numbring shall be hand written only, size of letter 100X10mm (Heightxwidth))
Servicing incl calibration/setting of all parameters and repairs of HT VCBs 11 KV of Crompton Greaves make complete incl cleaning and greasing including replacing of unserviceable parts as per existing and testing for satiafactory operation as per manufacturer standards complete all as specified and directed. Note : (i) Servicing incl calibration/setting of VCB will be carried out by an auth rep of Crompton Greaves/ Rep of state electricity board . Reports of the same duly signed by contractor and Engr-in- Charge kept in record. (ii) Spares shall be measured and paid seperately .
Supply and replacement of VCB indication lamps LED type as per existing clour code (as required) and making all connections as per existing complete all as specified and directed.
Supply and fixing in replcement of tripping and closing coil of VCB (Crompton Greaves makes) trolly as per existing incl taking out unsv complete all as specified and directed.
Scretching cleaning and preparation of old painted external surfaces to transformer of any size with two coats gray clour synthetic enamell paint and writing SM/MES nos complete all as specified by the Engr-in-Charge.
Disconnecting and taking down the defective transformers indoor/outdoor type 11 KV/433 Volts of capacity 75 KVA to 315 KVA from any position transporting to and from auth workshop for repairs, shifting back to site after repairs and installing at original position Repairs to transformers or at other position as directed, connecting up, commissioning and testing. Note: The item includes for draining out transformer oil, opening up transformer taking out complete, core and HV and LV windings to detect faults, reassembling the transformer after necessary repairs incl replacement of top rubberised / fiber gasket and worn out fastners such as nuts ,bolts, and washers for fixing of top covers pro Note : Repairs / Repairs shall be measured and paid separately.
Replacement of HV copper winding 3 limbs with the existing size and gauge of copper winding wire of existing weight of windinng wire all as specified and directed.
Replacement of LV copper winding 3 limbs with the existing size and gauge of copper winding wire of existing weight of windinng wire all as specified and directed.
Replacement of HV brass rods with porcelian bushing , nuts, bolts, washers gaskets suitable for 100 kva to 250 kva Transformer of any type all as specified and directed.
Replacement of LV brass rods with porcelain bushing , nuts, bolts, washers gaskets suitable for 100 kva to 250 kva Transformers of any type all as specified and directed.
Replacement of air breathers suitable for transformers 11 KV / 433 Volts of capacity up to 250 KVA.
Supply and replacement of Silica gel of breathers of transformers of type, any capacity and in any location complete all as specified and as directed.
Servicing of Transformer by arresting leakages by tightning nuts, bolts, repalcement of worn out washer of top cover and LV bushings , HV bushings complete all as directed.
De hydration and filteration of transformer oil of transformer any capacity indoor/outdoor type with dehydration machine incl checking of dielect strength of transformer oil before and after dehydration all as directed by Engr-in-Charge.
Supply and topping up the insulating oils for transformer of appropriate grade confirming to IS- 335 suitable for 11 kV/433 volts step down transformser.
Stringing and fixing only in position of sagged ACSR conductor in OH lines of street light conductor (squirrel/weasel), GI Earth wire complete including removing and refixing of UG cable/service wires to the ACSR conductor all as specified and as directed by engineer -in -charge.(The unit rate includes the cutting of branches of trees cominmg across the overhead line as directed.)
Laying only old serviceable bricks all as specified & directed by Engr-in- Charge
Supply and laying best quality bricks locally availanle sub class ‘B’ bricks (old size) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable ail as specified & directed by Engr-in-Charge.
S&F in replacement LT over Head line spacers, 4 wire 1100 volt grade complete all as specified and directed by Engr in Charge.
Supply and fix in replacementt 400 Amps MCCB, 415 Volts, 50 HZ complete all as specified and as directed.
Supply and fix in replacement of MCCB 250 Amps, FP 35 KA, 415 Volts, 50 HZ complete all as specified and as directed.
Supply and fix in replacement of MCCB FP 160 Amps, 25 KA, 415 Volts, 50 HZ complete all as specified and as directed.
Supply and fix in replacement of MCCB FP 160 Amps, 25 KA, 415 Volts, 50 HZ complete all as specified and as directed.
Supply and fix in replacement of MCCB FP 63 Amps, 25 KA, 415 Volts, 50 HZ complete all as specified and as directed.
Supply and fix in replacement LED type indication lamp set R-Y-B working at 220/240 V0lts AC incl taking out the old one complete all as specified and as directed.
Supply and replace in repairs LED flood light of 150 watt Pressure die-cast Al. fixture complete with all accessories and all for fixing arrangements all as specified and directed by the Engr-in-charge.
Supply and fix LED 40 watt post top with die cast aluminium body and with white powder coated aluminium reflector and IP-65 protection complete with fixing arrangements and elect connections and as directed by Engr-in-charge.
Supply and fixing in repairs power factor improvement statics condensor capacitor bank of capacity 25 KVAR including interconnection with LT panel with appropriate size of electrical cable complete all as specified.
All as item No. 31.00 above herein before but of capacity 12.5 KVAR.
All as item No. 31.00 above herein before but of capacity 10 KVAR.
All as item No 31.00 above herein before but of capacity 5 KVAR.
S&F in repalcement APFC relay 6/8 stage complete.
S&F Contactor 25 Amps 3 phase 415 volts
Supply, fixing, connecting, commissioning and testing of outdoor type automatic power factor control panel (capacitor banks) of capacity 75 KVAR, made out of 3mm thick CRCA sheet with angle iron bottom frame 50x50x6mm factory made, whether proof, dust and vermin proof (IP-55) suitable for 1100V, 3 phase, 50Hz, AC supply, with front and back door opening, locking arrangemnt. Pre wired with suitable copper conductor cable duly two coats of powder coated paint and grouted in and including suitable size complete all as directed.
Fabrication of LT panel doors of 3 mm thick MS sheet, angles, MS flat iron etc. incl cutting, welding, grinding and and fixing with LT panel incl all fixing arrangements, painting with one coat of synthetic enamell paint over a coat of of red oxide primer.
Repair/Maint day to day HT/LT electrical network in the jurisdiction of AGE B/R Sangrur cantt area scattered within 1 KM radius intimated by Engr-in-charge,JE,SBA as well as users by deploying dedicated team having good knowledge of comprising of HV/LV line and fault rectificationthe defect of day to day working as under :
Cleaning of all type breakers/switchgears, Transformer, Panels, tightening of connections in HT/LT breakers/ switchgears installed in sub station No -1,2,3,4,5,6,7,8,9,10,11,12&13 at various locations.
Replacement of HT fuse wire all as specified and directed by Engr-in-charge.
Repair/replacement of HT jumper all as specified and directed by Engr-in-charge.
Repair/replacement of GOD male/female contact all as specified and directed by Engr-in-charge.
Finding and rectification of fault on HT line and repair the HT line as specified and directed by Engr-in-charge.
Finding and rectification of fault on LT line and repair the LT line as specified and directed by Engr-in-charge.
Trimming of tree branches required during fault rectification all as specified and directed by Engr-in-charge.
Replacement of LED street lights of any type from existing pole all as specified and directed by Engr-in-charge.
Connecting/disconnecting of airconditioner in married offrs qtrs,OTM,Offrs mess from the existing lines all as specified and directed by Engr-in-charge.
Note(A) for Item No.40 to 49 above(A) : (a) Contractor will provide all T&P, communication device (Mobile Phone) to deployed persons required for repair of HT/LT Electrical switch gear including safety equipments such as all types of T&Ps (Bambooladders, screw drivers, wire/cable cutters with blades, multi meters, cutting pliers, tourch lights etc) for routine maintenance and protection of the trademan as well as daily activity incl safety dress, hand gloves, rubber boots, safety belts and helmets etc, complaint register, job card and necessary transportation required for attending complaints/faults/brake downs duty wiil be provided by the contractor without any extra cost. (b) On intimation of any type of fault tripping of HT/LT switch gear incomer as well as outgoing feeder the contractor is responsible to locate the fault by the dedicated team comprising tradesman helpers required numbers as per the gravity/nature of the work involved to restorethe power supply and communicate with SBA on duty and getting permit card for working on HT lines and deposit the permit card after rectification of fault, all the activities shall be carried out within reasonable time as given by the Engineer-in-charge. (c) Periodical maintenance of following feeders which includes trimming of tree branches which are touching with HT and LT feeders and overhead line, maintenance of GOD, jumpers, maintenance of defective disc or pin type insulators, tightening of jumpers, fixed and moving parts of GODs, restretching of HT/LT overhead line conductors falling due to storms.
Note (B) for item No. 40 to49 above : Penalty Charges : If any of the activity mentioned above is not performed by the contractor than recovery as under will be affected :- (a) Not providing T&P, protective clothing or safety equipment and not used by the team - Rs 500 per Job. (b) Not providing mobile phones duly re-charged or suitable transportation as per specified above or not attending the call - Rs 500 per job per mobile. (c) Not taken repair action within 01 hour after receiving job workt - Rs 500 per job.
Supply laying jointing copper service cable 16 sqmm 2 core fixing on wall/ducts etc including necessary fixing arrangement such as cable lugs glands etc complete after removing/taking out extg unsv cable to the entire satisfaction of Engr in Charge.
Supply laying jointing copper service cable 10 sqmm 2 core fixing on wall/ducts etc including necessary fixing arrangement such as cable lugs glands etc complete after removing/taking out extg unsv cable to the entire satisfaction of Engr in Charge.
Periodical cutting of all branches along above/under the over head lines with clearance of 2.0 mtr in Cantt area. (Approx length of HT/LT over head lines - 10.00 Kms)Note : (i) Periodical (Quarterly as per schedule fixed by the GE/Engr-in-Charge and approved by the Stn HQ.(ii) Payment shall be made at the end the of each qtr.(iii) Cutting/Trimming record register sign by contracrt to be maintained Quarterly basis.
R D Bansal
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .