Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.1 LAccepted-AOC | L1 | Accepted-AOC Lowest and negotiated tenderer | |
| 2 | L2₹37.4 L+₹1.3 L (3.69%)Rejected-AOC NO 2 15 SANTHIYUR ATTAYAMPATTI POST MALLUR VIA SALEM DISTRICT 636 203 | NAMAKKAL | TAMIL NADU | 636203 | L2 | Rejected-AOC Unsuccessful Tenderer |
Tender Value
Refer Docs
EMD Value
₹32,600
Closing Date
20 Jan 2025, 6:00 pmClosed
The Superintending Engineer/TNPHCL/NC/Salem
The Superintending Engineer/TNPHCL/North Circle, No.1 and 7, Inspectors quarters, PGR Line, Behind CPO Building, Annadhanapatty, Linemedu, Salem 636 006.
Special repair works for the Permanent Police Training School at PRS Campus in Coimbatore City.
2025_TNPHC_517962_1
SE/NC/DB/2/2025
Open Tender
Civil Works
Lump-sum
90 days
PRS Campus in Coimbatore City.
Refer the tender docuemnts
7 documents required · 7 mandatory
₹0
₹32,600
25 Jan 2025
10 Jan 2025
22 Jan 2025
10 Jan 2025
20 Jan 2025
10 Jan 2025
Amount
1.1 : Earth work excavation in all soils (including refilling) a. 0 to 2 mt.
30 : Ellispattern
31 : Weathering course
39 : S & F of M.s Grills
40 : Painting - New "wood work"
41 : Painting - New "iron work"
47 : S & F Alu Towel rail 75 cm long
48 : S & F 5 pin Coat stand
51.2: Supply and erection of Rotational Moulded Polyethylene water storage tanks (HDPE Cylinderical vertical type) for outdoor use having capacity of 1000 litres
52 : PVC Water supply (ASTM) a. 32 mm dia
b. 25 mm dia
c. 20 mm dia
55.2 : Flat Back Urinal
Electrical arrangements 78 : Earthing Station IS3043 (Type I)
86 : Anti termite treatment
112 : S & F of Exhaust Fan 300 mm dia
ANNEXURE-I 2.1.1 : Supplying and filling Gravel
3.1.1: P.C.C.1:5:10 for Foundation & Basement (using crushed stone sand)
3.3.1 : P.C.C. 1:8:16 using 20 mm broken brick jelly (using crushed stone sand)
6.2.1.1 : Brick work in C.M. 1:5 (F& B) with Admixture using Fly ash bricks of size 230x110x70mm having the compressive strength of not less than 100 Kg/CM²
8.1.1.1 : Standardised concrete Mix M20 Grade concrete. (using crushed stone sand) a) In Foundation and Basement.
b) In Ground Floor
9.2.1.1: Brick work in Cement Mortar 1:6 (One of cement and six of Crushed stone sand) with Admixture using Fly ash bricks of size 230x110x70mm having the compressive strength of not less than 100 Kg/CM² for superstructure in the following floors a. In Ground floor
10.2.1.1 : Brick partition wall in Cement Mortar 1:4 (One of cement and four of Crushed stone sand with Admixture) 110mm thick for super structure in the following floors using Fly ash bricks of size 230x110x70mm having the compressive strength of not less than 100 Kg/CM² in the following floors b. In Ground Floor
14.1.1.II : Precast cupboard slab 40 mm tk using standardised concrete mix M20 grade.(using crushed stone sand) a. In Foundation & basement
18.1 : Formwork using M.S.Sheet a.For Column footings, plinth beam, Grade beam, Raftbeam, Raft slab etc.,
b.Plain surfaces such as Roof slab,floorslab,Beams,lintels,lofts,sill slab,staircase,portico slab and other similar works
c.For Square and rectangular columns and small quantities
21.5.2 : Supply and fixing Solid UPVC door shutter with frame
22.2 : Teak wood glazed window and ventilators shutters 6.25 x 3.12cm styles and rails and 3mm thick ground or frosted glass for panels including labour charges and cost of furniture fittings as per schedule ‘E’ and as directed by the departmental officers. a) T.W. glazed single leaf for each bay to suit window frames of over all height 135cm.
23.2.1 : 4mm thick pin headed Glass panels with Aluminium beedings
26.1 : Flooring in C.C.1:5:10 (using crushed stone sand)
28.1 : Floor plastering in C.M. 1:4, 20 mm tk. (using crushed stone sand)
29.8.1 : Glazed tiles using Grout (Tile Joint Filler) (using crushed stone sand)
29.9.1 : Floor ceramic tiles using Grout (Tile Joint Filler) (antiskid) (using crushed stone sand)
32.1.1: Finishing top of roof with one course of Hydraulic Pressed Tiles of approved superior quality of size 23cmx23cmx20mm thick laid over weathering course in cm 1:3 (One of cement and three of crushed stone sand) 12mm thick mixed with Water proofing compound at 2%
33.1 : Plastering in C.M. 1:5, 12 mm tk. (using crushed stone sand) including plasticizer
34.1 : Plastering in C.M. 1:4, 12 mm tk.(using crushed stone sand) using plasticizer
35.1.2 : Spl. Ceiling plastering in C.M. 1:3, 10 mm tk. (using crushed stone sand) using plasticizer
36.1 : Cement mortar Border in C.M. 1:5, 12 mm tk. (using crushed stone sand) b. 75mm wide
c. 50 mm wide
38.7 : Plastic Emulsion PAINT including primer for inner walls
43.1 : Supply & Fabrication of Mild steel / RTS grills (without cement slurry) for all sizes of rods.
44.2.1 : Rain water harvesting using defunct borewell and providing perforated cover slab (M20) b) Augering 30cm dia
44.6 : PVC SWR 110 mm dia with ISI mark type- A for Rain water down fall pipe
53.5.2 : Wash Hand Basin of size 550 x 400 mm (White without Pedestal)
54.1.1 : S & F of 15mm dia half turn CP long body tap
54.2.1 : S & F of 15mm dia half turn CP short body tap
57.1.2 : S & F of E.W.C (White) 500mm with PVC SWR grade "P" or "S" Trap (using crushed stone sand)
58.3 : PVC SWR pipe (Soil line) with ISI mark - type 'B'. a. 110mm dia.
b. 75mm dia.
59.2.1 : Gully Trap using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") (using crushed stone sand)
60.1 : PVC Nahani trap (4way/2way)
61.3 : UPVC Non Pressure pipe of SN8 SDR 34 (S 16.5) as per IS 15328/2003 a. 110 mm UPVC Non Pressure pipe
b. 160 mm UPVC Non Pressure pipe
64.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. a. Light point with ceiling rose
b. Light point without ceiling rose
67.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Switch Board Itself.
214 : Dismantling the damaged brick masonry works in cement mortar in all floors without affecting the adjacent structures, including the cost of required tools and plants and clearing the debris away from the site including cost of loading, unloading & vehicle hire charges etc., all complete in all respect and as directed by the departmental officers. a) Upto 3.00m height
218: Dismantling the damaged one course pressed tiles in cement mortar without affecting the adjacent structures in all floors including the cost of required tools and plants and clearing the debris away from the site etc., all complete and as directed by the departmental officers.
344 : S&F of Bevelled edge mirror 600 x 450 x 5.5mm
384: S&F of PVC flushing cistern
ANNEXURE - II A1: THREE PHASE PANEL BOARD- D.O.L WITH TWO LEVEL GUARD AND AUTO START Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately). For 5HP
A2: Supplying and laying of 80mm dia GI pipe "B" Class of best and approved quality having ISI mark including cost of labour charges & materials for earth work excavation, laying charges & jointing and cost of conveyance & necessary specials etc., all complete and as directed by the departmental officers. (Below GL)
A3: Supplying and laying of 25mm dia GI pipe "B" Class of best and approved quality having ISI mark including cost of labour charges & materials for earth work excavation, laying charges & jointing and cost of conveyance & necessary specials etc., all complete and as directed by the departmental officers. (Below GL)
A4: Supplying and fixing of following dia GM gate valve including cost of material, cost of labour charges for fixing etc., all complete and as directed by the departmental officers. a) 25mm dia Gun Metal gate valve
b) 32mm dia Gun Metal gate valve
c) 40mm dia Gun Metal gate valve
d) 65mm dia Gun Metal gate valve
e) 80mm dia Gun Metal gate valve
A5: Supplying and fixing of CP Two way Bib Cock with Health Faucet of best approved quality with ISI mark etc., including cost of material and labour charges charges etc,. all complete and as directed by the departmental officers. (Bib Cock shall be got approved from the E.E. before fixing)
A6: Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un- plasticized polyvinyl chloride (UPVC) sections.
A7: Supplying & fixing in position of UPVC Ventilator Louvered type for all sizes
A8: Supplying and fixing of Mosquito netlon for windows including cost of PVC mesh (Saint-Gobin) tape role, (Velcro) nails and fixing to the existing doors & windows including cost of materials & labour charges for fixing in position etc., all complete and as directed by the departmental officers. (The brand and colour should be got approved by the Executive Engineer before use)
A9: Supply and delivery at site and fixing of 600mm x 600mm size SFRC manhole cover with frame with locking arrangement including cost of all materials and labour charges for fixing in position etc., all complete and as directed by the departmental officers.
A10: Supply and delivery of 3 core 4.0 sqmm 1100V grade copper UG flat cable of best and approved quality having ISI mark etc., all complete as directed by the departmental officers.
A11: Run of 2 Wires of 2.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. (Open Wiring).
A12: Supplying and fixing of LED blubs suitable for fixing it to pendent / bakelite battern holder of best approved variety a) 9 watts LED bulb
A13: Supplying and fixing of 18W LED TUBE LIGHTS 4' long with necessary fittings and charges for assembling and fixing
A14: Painting the old Iron work and other similar works such as PVC /ASTM Pipes, Kerb Stone and grills with one coat of approved first class synthetic enamel ready mixed paint of approved quality and brand, with relevant Standard specifications including thorough scrapping, material & labour charges etc., all complete (paints and its shade shall be got approved from the Executive Engineer before using)
A15: Painting one coat for old wall with ready mixed PLASTIC EMULSION PAINT of first class quality paint of approved colour and shade, including cost of materials, thorough Scrapping,necessary brushes, labour charges, patty etc., all complete.
A16: Supply, installation, testing and commissioning of 15 KVA Diesel Generator set complete with all accessories like engine, alternator, batteries with leads control panel, base frame, antivibration mounts, residential silencer,100 litres fuel tank, intake & exhaust piping, fuel oil motor operated pump, other miscellaneous accessories for the total set including test trial run at load for 8 hrs at factory (inclusive of consumable oil etc) necessary control wiring for battery charger etc., complete.
A17: Supply, installation, testing and commissioning of 25 KVA Diesel Generator set complete with all accessories like engine, alternator, batteries with leads control panel, base frame, antivibration mounts, residential silencer,100 litres fuel tank, intake & exhaust piping, fuel oil motor operated pump, other miscellaneous accessories for the total set including test trial run at load for 8 hrs at factory (inclusive of consumable oil etc) necessary control wiring for battery charger etc., complete.
A18: Supply and laying of XLPE, copper conductor 1.1KV grade armoured, MV cable of the following sizes in the existing cable trays / trenches as required generally confirming to IS: 1554/Part - I / 1970. The cables are to be laid in ground / in a trench to be excavated at a depth of 0.75 Mtr. putting 0.15 Mtr. layer of sand and covering the cable completely with brick and sand and refilling the earth to make good. a. 3.5 x 25 sqmm copper cable
A19: Supply and fixing of brass cable gland for XLPE armoured LTUG cable for following sizes with earth connection. a. 3.5x 25 sqmm copper cable gland
A20: Supply and providing cable end termination of following sizes of XLPE armoured LTUG Aluminium cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete. a. 3.5 x 25 sqmm copper cable termination
A21: Plate earthing with copper plate of size 600 x 600 x 3 mm as per the ISI specification with an earth electrode of 2.1 mtr class 'B' GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry. (for neutral earthing)
A22: Supply and run of 2 of No.8 copper wire for earth connections to the individual tenements from the earth bus etc., all complete.
A23: Supply and fixing of 25mm x 6mm tin coated copper flat on wall with necessary supports for termination of earth connection in the lift machine room etc., all complete.
A24: Supply and clamping of 4 core 4 sq.mm PVC sheathed and armoured copper cable from alternator to the proposed DG panel on wall / in the hume pipe with necessary glands and crimping at both ends.
A25: Pointing the disturbed portion of Pressed Tiles in cement mortar 1:3 (One of Cement and three of crushed stone Sand) 20mm thick for full depth of tiles including curing and racking out the joints of 20mm deep and disposing the debries away from the site etc., all complete and as directed by the departmental officers
A26: Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed. Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete.
A27: Construction of Inspection chamber with brickjelly cement concrete 1:3:16 (One of cement, eight of crushed stone sand and sixteen of broken brick jelly 40mm gauge 15cm, thick for foundation and 23cm thick brick mansonry in c.m 1:5 using fly ash bricks of size 230x110x70mm and plastering with c.m 1:3 (one of cement, three of crushed stone sand and four of hard broken stone 20mm gauge) 5cm thick precast cover slab excluding the cost and fabrication of reinforcement grills but including benching channelling fixing the cover slab in position curing, finishing etc., complete in all respects. a) Inspection Chamber size 60x60x60cm
A28: Supply and laying UG cable for Below ground level with 20mm dia "B" class GI pipe and including earth work excavation, laying of cable with G.I pipe, jointing, refilling and including cost of 20mm GI pipe of best approved quality and labour charges etc., all complete as per relavent standard specification and as directed by the departmental officer.
A29: Supplying and fixing of 40mm dia PVC pipe of best approved quality including cost of pipe and required specials and labour charges etc., all complete as per relavent standard specification and as directed by the departmental officer. Above ground level
A30: Service charges for RO 250 LPH membrane chemical cleaning, Raw water pump service, Runxin auto MPV 20 NB, 2.5X20 Wound Catrdige, Dosing pump with 100 Ltr tank including cost of materials, labour for fixing etc., all complete and as directed by the departmental officers.
LGN CONSTRUCTION (BID ID -1234482)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_616405.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .