Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.1 LAccepted-Finance 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | L1 | Accepted-Finance Admitted being the lowest | |
| 2 | L2₹9.1 L+₹1.1 L (13.5%)Rejected-Finance D 3 7TH BLOCK JAIN GREEN ACRES DHARGA ROAD ZAMIN PALLAVARAM CHENNAI 600043 | CHENNAI | CHENNAI | TAMIL NADU | 600043 | L2 | Rejected-Finance L1 BEING ACCEPTED | |
| 3 | L3₹9.2 L+₹1.1 L (13.8%)Rejected-Finance 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | L3 | Rejected-Finance L1 BEING ACCEPTED |
Tender Value
₹10.0 L
EMD Value
₹20,000
Closing Date
21 Aug 2023, 6:00 pmClosed
Garrison Engineer (I)(CG) Chennai
Garrison Engineer (I) (CG) Military Engineer ServiceCGRA Meenambakkam Building No P 16 NGO Colony 4th Street Nanganallur Chennai 600 061
Maintenance Replacement of spare parts of split AC casette AC Refrigerator Water Cooler Deep Freezer and allied works at ICGAS Minambakkam CGRA Thalakanchery under GE (I) (CG) Chennai.
2023_MES_612260_1
8057/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
Garrison Engineer (I)(CG) Chennai
All as per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (I)(CG) Chennai
₹20,000
Yes
12 Sept 2023
5 Aug 2023
23 Aug 2023
5 Aug 2023
21 Aug 2023
11 Aug 2023
Amount
Labour for checking of split type air conditioner of capacity 1.0/1.5/2.0 TR to find out the defect and regular servicing of air conditioner unit (i.e) washing of air filter, cleaning of surface of indoor unit, flushing of drainage system,cleaning of coils and fins etc complete all as specified and directed. Note : Replacement of spare parts shall be measured and paid for seperately.
Labour for checking of Cassette type air conditioner of capacity 2.0/3.0 TR to find out the defect and regular servicing of air conditioner unit (i.e) washing of air filter, cleaning of surface of indoor unit, flushing of drainage system,cleaning of coils and fins etc complete all as specified and directed. Note : Replacement of spare parts shall be measured and paid for seperately.
Supply and fix remote control suitable for 1.5/2.0/3.0 ton capacity Split type/Cassette AC including testing and commissioning etc and taking down unserviceable item and taken as credit complete all as specified and directed. Make:Carrier/Hitachi/voltas/Blue star/llyod
Description all as per Sl item No 3.00 herein before but Copper Condenser coil and including servicing complete unit as per existing make and model
Description all as per Sl item No 3.00 herein before but condenser fan motor of suitable capacity and including servicing complete unit. Make Frogmaster/AUE
Description all as per Sl item No 3.00herein before but Indoor unit blower motor for 1.5/2.0/3.0 ton capactiy.Make:Frog master/AUE
Description all as per Sl item No 3.00 herein before but Indoor unit swing motor or 1.5/2.0/3.0 ton capactiy and including servicing complete unit
Description all as per Sl item No 3.00 herein before but fan blade set. Make:Arvind or equivalent
Description all as per Sl item No 3.00 herein before but PVC drain pipe flexible type of suitable size and including servicing complete unit
Description all as per Sl item No 3.00 herein before but wiring kit complete as per existing make and model
Description all as per Sl item No 3.00 herein before but Dual capacitor 50+ 6 MFD .Make:Keltron/usha/upron
Description all as per Sl item No 3.00 herein before but thermostat.Make : Indfoss /Renutrol/Sriram
Description all as per Sl item No 3.00 herein before but Contactor relay.Make:AE/Keltron/indfoss
Description all as per Sl item No 3.00 herein before but air filter
Description all as per Sl item No 3.00 herein before but suction valve,
Description all as per Sl item No 3.00 herein before but discharge valve
Description all as per Sl item No 3.00 herein before but Outdoor unit wall mount powder coated metal brackets with accessories.
Supply and fix Copper Cooling coil suitable for 1.5/2.0 ton capacity Split type including testing and commissioning etc and taking down unserviceable item and taken as credit complete all as specified and directed.
Supply and fix Copper Cooling coil suitable for 2.0/3.0 ton Cassette type including testing and commissioning etc and taking down unserviceable item and taken as credit complete all as specified and directed.
Supply and fix copper pipe for Suction line of size 1/2" or 5/8" with insulation and sleeve for all Split/cassette AC of any capacity including dismantling the unserviceable pipe and taken as credit complete all as specified and directed.
Supply and fix copper pipe for Discharge line of size 1/4" or 3/8" insulation and sleeve for all Split/cassette AC of any capacity including dismantling the unserviceable pipe and taken as credit complete all as specified and directed.
Supply and fix three core flexible cord copper wire of size 2.5 /4Sqmm complete all as specified and directed.Make:Finolex/KEI/Anchor
Dismantling unserviceable uncut hermitically sealed compressor from the split type AC unit and replaced with new hermitically sealed compressor for split type Air conditioner 1.5 Ton capacity including transporting and including servicing complete unit all as specified and as directed. Note :- (i)Compressor test reports along with warranty shall be provided for record. (ii) Gas charging shall be measured and paid for separately.Make:Carrier/Hitachi/voltas/Blue star/llyod
Dismantling unserviceable uncut hermitically sealed compressor from the split type / Cassette type AC unit and replaced with new hermitically sealed compressor for split/cassette type Air conditioner 2.0 Ton capacity including transporting and including servicing complete unit all as specified and as directed. Note :- (i)Compressor test reports along with warranty shall be provided for record. (ii) Gas charging shall be measured and paid for separately.Make:Carrier/Hitachi/voltas/Blue star/llyod
Dismantling unserviceable uncut hermitically sealed compressor from the Cassette type AC unit and replaced with new hermitically sealed compressor for cassetee type Air conditioner 3.0 Ton capacity including transporting and including servicing complete unit all as specified and as directed. Note :- (i)Compressor test reports along with warranty shall be provided for record. (ii) Gas charging shall be measured and paid for separately.Make:Carrier/Hitachi/voltas/Blue star/llyod
Supply and fix single pole and neutral sheet metal enclosure with two pin and earth plug and socket complete with single pole MCB 20 Amps,240 V including taking down old item and taken as credit complete all as specified and as directed. Make : Indo Asian/L&T/Siemen
Dismantling unserviceable Outdoor unit from the split/cassette type unit and replaced with new outdoor unit (Includes compressor,condenser coil, condenser fan motor etc.) with suitable refrigerant gas support(R32/R410A/R22) of BEE 3 star rating 1.5 ton capactiy complete all as specified and directed. Note : (i)Gas charging shall be measured and paid separately. (ii) Company warranty certificate shall be produced by the contractor.Make:carrier/Hitachi/Voltas/Blue star/llyod/ O general/LG
Description all as per Sl item No 27.00 herein before but of 2.0 Ton capacity. Note : (i)Gas charging shall be measured and paid separately. (ii) Company warranty certificate shall be produced by the contractor Make:carrier/Hitachi/Voltas/Blue star/llyod/ O general/LG
Dismantling the unserviceable Indoor unit of the split type unit and replaced with new indoor unit(Includes evaporator coil, PCB etc.) with suitable refrigerant gas support(R32/R410A/R22) for split type AC BEE 3 star rating 1.5 ton capactiy complete all as specified and directed.Make:carrier/Hitachi/Voltas/Blue star/llyod/ O general/LG Note : (i)Gas charging shall be measured and paid separately. (ii) Company warranty certificate shall be produced by the contractor Make:carrier/Hitachi/Voltas/Blue star/llyod/ O general/LG
Description all as per Sl item No 29.00 herein before but of 2.0 Ton capacity. Note : (i)Gas charging shall be measured and paid separately. (ii) Company warranty certificate shall be produced by the contractor Make:carrier/Hitachi/Voltas/Blue star/llyod/ O general/LG
Material and labour for pressure testing the Split AC 1.50/2.00TR capacity, with nitrogen gas after flushing out the system free from refrigerant ,checking for leakages if any in the refrigerant system making good the leaking spots with necessary brazing/welding, ensuring leak proof system charging the refrigerant gas including replacing the strainer & capillary etc with new items and testing for satisfactory performance complete all as specified and as directed Note:Refrigerant gas charged shall be measured and paid separately under relevant item mentioned below.
Description all as per Sl item No 31.00 herein before but for cassette AC 2.0/3.0 TR capacity
Taking down existing worn out winding from fan motor , rewinding the fan motor of Split AC of capacity 1.5 TR/2.00 TR with super enamelled copper wire of suitable gauge capacity, bringing back to worksite and refixing the same on its position including replacement of bushes complete all as specified and as directed.
Taking down the PCB control box assembly and check for the fault on electronic components such as Integrated circuits,diodes,resistors,capacitors,transformer,indoor fan motor capacitor,sensors,buzzer,relay,indicators etc and replaced the worn out component with new items for Fixed speed/Non inverter type Split type AC of capacity 1.5 TR/2.00 TR , bringing back to worksite and refixing the same on its position complete all as specified and as directed.
Description all as per Sl item No 34.00 here in before but for Inverter type split type AC of 1.5 TR/2.0 TR capacity.
Description all as per Sl item No 34.00 here in before but for Cassette type AC of 2.0 TR/3.0 TR capacity.
Labour for water leak arrest of split type AC of any capacity by unblocking the clogged drain pipe by removing dirt and debris and make smooth flow of condensate drain water complete all as specified and directed.
Description all as per item no:37 here in before but for cassette AC of any capacity.
Supply only Refrigerant Gas R-22 complete all as specified and directed
Supply only Refrigerant Gas R-410A /R-32 complete all as specified and directed
Shifting of split type Air conditioner any capacity including fixing only powder coated metal bracket support suitable to mount out door unit (one pair per AC) and indoor unit duly making holes into the wall for insertion of copper pipe,drain pipe and 3 core cable,and making good the distrubed surfaces complete and including servicing complete unit all as specified and as directed.
Matrial and labour for Spray painting to the whole out door unit of split type air conditioner 1.5/2.0 Ton with two coats of synthetic enamel paint after cleaning the unit assembly and including servicing the entire unit complete all as specified and directed.
Dismantling the unserviceable uncut hermitically sealed compressor from the water cooler unit and replaced with new re-conditioned hermitically sealed compressor for water cooler any make 40/ 80 ltrs capacity and including servicing complete unit all as specified and as directed. Note :(i)Gas charging shall be measured and paid separately. (ii) Company warranty certificate shall be produced by the contractor. Make:voltas/Blue star/Usha
Supply and fix Starting relay for 40 to 150 Ltrs water cooler including dismantiling the old unserviceable one and including servicing complete unit all as specified and directed. Make:AE/Keltron/Indfoss
Description all as per Sl item No 44.00 herein before but over load protector and including servicing complete unit. Make:Renutral/Annapurna
Description all as per Sl item No 44.00 herein before but thermostat.Make : Keil/Tiplon
Description all as per Sl item No 44.00 herein before but Fan blade assembly suitable.Make:Arvind or equivalent
Description all as per Sl item No 44.00 herein before but wiring kit
Description all as per Sl item No 44.00 herein before but push lock Brass chromium plated of size 15 mm dia
Description all as per Sl item No 44.00 herein before but branded new fan motor with base 1/10HP .Make:Frog master/AUE
Description all as per Sl item No 44.00 herein before but top lid gasket for 80/120 Litre capacity water cooler
Description all as per Sl item No 44.00 herein before but drain stainless steel tray with drain elbow and connector
Description all as per Sl item No 44.00 herein before but Gate valve brass screwed both ends of size 15mm bore .Make:Leader/Zoloto
Description all as per Sl item No 44.00 herein before but Float valves brass with PVC ball complete suitable for 15mm bore ISI marked. Make:Leader
Description all as per Sl item No 44.00 herein before but PVC hose connection pipe both ends having brass coupling threaded for 15mm GI tube of standard length
Dismantling the unserviceable uncut hermitically sealed compressor from the Refrigerator unit and replaced with new hermitically sealed compressor for refrigerator any make 165 litre to 310 litre capacity and including servicing complete unit all as specified and directed Note : Gas charging shall be measured and paid separately Make:LG/Whirlpool
Supply and fix relay for 165 to 310 Litres Refrigerator including dismantling the old unserviceable one complete all as specified and directed.Make : Indofoss/Ranutral/Annapurna
Description all as per Sl item No 57.00 herein before but over load protector 1/6 HP .Make:Whrilpool/ Kelvinator/Godrej
Description all as per Sl item No 57.00 herein before but bulb pin/screw type 10/15 W capacity.Make : Philips/Bajaj/CG
Description all as per Sl item No 57.00 herein before but thermosat defrosting type Make :Keil/Tiplon
Description all as per Sl item No 57.00 herein before but light switch for refrigerator
Description all as per Sl item No 57.00 herein before but cooling coil
Description all as per Sl item No 57.00 herein before but condensor coil
Description all as per Sl item No 57.00 herein before but freezer door
Description all as per Sl item No 57.00 herein before but vegetable tray with glass.
Description all as per Sl item No 57.00 herein before but PVC ice tray.
Description all as per Sl item No 57.00 herein before but new frost freezer motor
Renewal of entire portion of base plate and legs ,welding with proper gauge new MS sheet complete all as directed and specified of refrigerators capacity 165 litres to 310 litres complete all as specified and directed.
Dismantling the unserviceable uncut hermitically sealed compressor from the deep freezer unit and replaced with factory re-conditioned hermitically sealed compressor for deep freezer any make up to 500 litres capacity complete all as specified and directed Note : Gas charging shall be measured and paid separatly. Make:LG/Whirlpool
Supply and fix relay box type deep freezer including dismantling the old unserviceable items complete all as specified and directed.
Description all as per Sl item No 70.00 herein before but overload protector 1/6HP. .Make:Whrilpool/ Kelvinator/Godrej
Description all as per Sl item No 70.00 herein before but door magnetic gasket.
Description all as per Sl item No 70.00 herein before but condenser coil
Description all as per Sl item No 70.00 herein before but brand new fan motor with base 1/10HP Make Frogmaster/AUE
Renewal of entire portion of base plate and legs ,welding with proper gauge new MS sheet complete all as directed and specified for deep freezer of capacity 500 litres complete all as specified and directed.
Taking out voltage stablizer of any make and of capacity 5 KVA from site and transporting to service centre to detect /identify the nature of defects/repairs and reassembling after repair/servicing commissioning at site and testing to the entire satisfaction of Engineer-in-Charge complete all as specified and directed.
Description all as per Sl item No 76.00 herein before but of capactity 4 KVA.
Dismantling the burnt out transformer from the 5 KVA capacity stablizer of any make and rewinding the same with supper enameled copper wire including provision of all materials and refixing into the stablizer and testing complete all as specified and directed.
Description all as per Sl item No 78.00 herein before but of capactity 4 KVA.
Supply and fix relay set of two for voltage stabilizer up to 5 KVA capacity complete all as specified and directed.
Description all as per Sl item No 80.00 herein before but PCB (printed circuit board)
NOTE: (i) Total 1 Nos of AC Technician (Each Area 1 no of Electrain) as specified below A. CGAS and othere Area shall be employed daily by the contractor for the purpose of maintaining the Air conditioning throughout the contract period . (ii)The tenderers are advised to visit the work site and assess the quantum of work to be executed before quoting the tender. (iii) A register shall be maintained to show the date and time of complaint and date and time of rectification duly signed by a rep of users of the unit concerned and countersigned by JE/AGE.
lakshmibuilders
EVEREST ENGINEERING WORKS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .