Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 LAccepted-AOC NO 5 3 JJ KHAN ROAD 1ST LANE ROYAPETTAH CHENNAI 600 014 | CHENNAI | TAMIL NADU | 600014 | L1 | Accepted-AOC L1 | |
| 2 | L2₹17.6 L+₹11,730 (0.67%)Rejected-Finance 4 1 70 1 ROAD NO 11 SNEHAPURI NACHARAM HYDERABAD 500 076 | HYDERABAD | MEDCHAL MALKAJGIRI | TELANGANA | 500076 | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹18.5 L+₹99,730 (5.70%)Rejected-Finance CHENNAI | CHENNAI | TAMIL NADU | 600001 | L3 | Rejected-Finance L1 being accepted | |
| 4 | L4₹18.8 L+₹1.3 L (7.22%)Rejected-Finance 184 C 13 THURAIYUR SAMINATHAN NAGAR PERAMBALUR SALAI TIRUCHIRAPPALLI TAMIL NADU 621010 UDYAM TN 27 0052941 | TIRUCHIRAPPALLI | TAMIL NADU | 621010 | L4 | Rejected-Finance L1 being accepted | |
| 5 | L5₹19.8 L+₹2.3 L (13.0%)Rejected-Finance CHENNAI | L5 | Rejected-Finance L1 being accepted |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
26 Nov 2020, 6:00 pmClosed
GE Tirunelveli
GE TIRUNELVELI INS KATTABOMMAN NAVAL BASE POST VIJAYANARAYANAMTIRUNELVELI
REPAIRS/REPLACEMENT OF INTERNAL WIRING, RENEWAL OF FTL/CFL LIGHT FAN ANd GEYSERS AT CERTAIN MARRIED ACCN AT KATTABOMAN AND RSP UNDER GE TIRUNELVELI
2020_MES_388642_1
GE/TVL/8129
Open Tender
Miscellaneous Works
Item Rate
180 days
Vijayanarayanam
As per NIT/ Tender documents
8 documents required · 8 mandatory
₹500
GE Tirunelveli
₹40,000
Yes
4 Jan 2021
21 Oct 2020
28 Nov 2020
21 Oct 2020
26 Nov 2020
4 Nov 2020
21 Oct 2020 - 30 Oct 2020
Amount
SCHEDULE 'A'(PART-I INTERNAL ELECTRIFICATION)
Taking down carefully copper/aluminium point wiring (light, fan, socket and power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc and making good disturbed surfaces of walls, floors etc.
Supply and fix for Point wiring with two single core 1100 V grade conforming to IS-694 PVC insulated unsheathed cables of size 1.5 Sq mm multi-stranded Copper conductor FRLS drawn through and including 20mm dia rigid PVC conduit and conduit accessories fixed on surface making good to disturbed surfaces in wall/roof/ceiling where required complete with 3 mm hylam sheet cover with an earth wire of PVC cable 1.5 Sqmm multi stranded copper conductor FRLS and connected to all metal boxes and common earth dolly all as specified and directed for the following :-
(a) One light/fan point/ bell point controlled by one one-way switch SP 5 Amps
(b) One 3 pin 5 Amps switch socket combination on the same board with other switches, with cables 1.5 Sqmm size all specified and as directed.
All as per item 3.0 but only wiring with two single core 1100 V grade conforming to IS-694 PVC insulated unsheathed cables of size 1.5 Sq mm multi-stranded Copper conductor FRLS including an earth wire of PVC cable 1.5 Sqmm multi stranded copper conductor FRLS drawn through pvc counduit surface type wiring complete all specified and as directed for the following :-
One light/fan point/ bell point controlled by one one-way switch SP 5 Amps
One 3 pin 5 Amps switch socket combination on the same board with other switches, with cables 1.5 Sqmm size all specified and as directed.
All as per item 3.0 but only wiring with two single core 1100 V grade conforming to IS-694 PVC insulated unsheathed cables of size 1.5 Sq mm multi-stranded Copper conductor RRLS including an earth wire of PVC cable 1.5 Sqmm multi stranded copper conductor FRLS drawn through on existing conduit in cocealed without conduit complete all specified and as directed for the following :-
One light/fan point/ bell point controlled by one one-way switch SP 5 Amps
One 3 pin 5 Amps switch socket combination on the same board with other switches, with cables 1.5 Sqmm size all specified and as directed.
All as per Item No. 03, but 2.5 Sqmm size copper conductor cable FRLS and 1.5 Sqmm copper earth wire cable FRLS drawn through 20 mm dia PVC conduit including provision of conduit and conduit accessories for One 5 pin, 15 Amps Multi purpose switch socket combination on independent board complete all specified and as directed.
All as per Item No. 12, but 2.5 Sqmm size copper conductor cable FRLS (concealed and make good distrubed surface) and 1.5 Sqmm copper earth wire cable FRLS drawn through 20 mm dia PVC conduit including provision of conduit and conduit accessories for One 5 pin, 15 Amps Multi purpose switch socket combination on independent board complete all specified and as directed.
All as per Item No. 12, but 2.5 Sqmm size copper conductor cable FRLS and 1.5 Sqmm copper earth wire cable FRLS drawn through in existing PVC conduit/surface for One 5 pin, 15 Amps Multi purpose switch socket combination on independent board all specified and as directed.
Supply and Fix in repairs Switch Piano, flush type, Single Pole, 230 Volts, AC, one-way 5 Amps with ISI mark all specified and as directed. Make: Anchor Cat Part No 38739 or equivalent with ISI mark.
Supply and Fix in repairs Switch socket outlet, multipurpose, flush type, 3/5 Pin,AC, 230 Volts, 5 Amps complete all specified and as directed. Make: Anchor Cat Part No 38820 or equivalent with ISI mark.
Supply and Fix in repairs switch socket outlet, multipurpose, flush type, 5 in 1, 5 A/16 Amps, AC, 230 Volts, complete all specified and as directed. Make: Anchor Cat Part No 38819 universal with ISI mark or equivalent.
Supply and fix in repairs for Bell push, AC, 230 V flush type single pole, 5 Amps complete all specified and as directed. Make: Anchor Cat Part No 38750 with ISI mark or equivalent.
Supply and Fix in repairs for DING DONG bell AC 240 V single pole 50 Hz and connecting up complete all specified and as directed. Make : Anchor/Bajaj/Plaza/Leader
Supply and fix in repairs electronic type fan regulator rotary step 100 watts complete all specified and as directed. Make: Anchor Cat Part code No 38660 or equivalent.
Supply and Fix in repair Ceiling rose 2 to 3 terminals, surface bakelite 65 x 50mm complete all specified and as directed. Make : Anchor / Bajaj / Leader / Cona with ISI mark.
Supply and Fix in repairs of bottom and top conopy of ceilling fan of any size all as specified and directed. Make : Usha or equivalent to CG / Bajaj
Supply and Fix in repairs of ceilling fan clamp with suitable nut, bolt, washer and split pin etc. all as specified and directed.
Supply and fix in repair Sheet metal enclosures for DBs single pole 8 way 240 V with neutral bus bar 200 Amps double door type with locking arrangement complete all specified and as directed. Make : Legrand/ Asian /Indokopp/ Standard/ ABB /Havells.
Supply and fix in repair Sheet metal enclosures, double door for MCB DB, 4 way, TPN, AC 415 Volts complete all specified and as directed. Make : Legrand/ Asian /Indokopp /Standard /ABB /Havells
Supply and fix in repairs MCB TPN, AC 415 Volts 40 Amps 10 KA complete all specified and as directed.
Supply and fix in repairs for MCB SPN, AC 240 Volts 32 Amps 10 KA complete all specified and as directed.
Supply and fix in repairs MCB SP 240 V, 6A to 30 Amps 10 KA rupturing capacity complete all as specified and as directed.
Taking down carefully sub main wiring of any description including batten / PVC conduit pipe on surface and making good disturbed surfaces to match existing all as specified and as directed.
Material and Labour for sub main wiring with single core 1100 V grade conforming to IS 694 PVC insulated unsheathed cables two run 6 Sq mm multi stranded copper conductor FRLS drawn through and including 25 mm dia non metallic PVC rigid conduit and conduit accessories fixed on walls/roof/floors/ceiling etc with an earth wire of one run 4 sqmm copper wire earth continuity conductor etc and making good disturbed surfaces to match existing all as specified and directed. Note : Two runs of 6 sqmm cable & one runs of 4 sqmm cable and one run of PVC conduit shall be measured as one run.
Supply and fix capacitor 2.5 mfd suitable for ceiling fan complete all as specified and as directed.
Taking down geyser of any make, type and any capacity after disconnecting the water and electric line connections from any height, bringing down to floor, dismantling the Geyser and overhauling by means of repair/replacement of the defective spares, descaling of tank and inlet/outlet pipes, checking/testing of all safety devices etc including cleaning externally and internally re-assembling the geyser, fixing in position and testing for satisfactory working etc complete. Note: Replacement of defective spares shall be measured and paid under relevant item separately.
Supply only following spares suitable for Geyser:-
Neon lamp indicator
Bottom flange with inlet and outlet pipe (Apparatus plate)
Thermostat conforming to IS 3017 including setting
Flexible connection for cold/hot water
Heating element 1.5 KW
Heating element 2 KW
Taking out copper container carefully from geyser rectifying the leakages by bracing, re-fixing back including replacing insulating materials all as directed by Engineer-in-Charge for 25 Litres capacity complete all as directed.
All as per item No.40, but for 50 Litres capacity
Material and labour for Spray painting and numbering of geyser complete with one coat of synthetic enamel paint with approved quality including preparation of the surface all as directed for the following capacities:-
(a) 25 Litres capacity Geyser
(b) 50 Litres capacity Geyser
Taking down existing unserviceable 4 feet with bipin holder 2 Nos and Supply and fixing of new LED lamp 4 feet including bipin holder 2 Nos all as specified. Make-Philips Cat No Stellar Bright TLED 6500K tube or equivalent to Crompton/Havells
Supply and fix in repairs LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver including Stellar bright 20 watt TLED box type complete with all accessories internally pre wired and including connecting up with twin / three core flexible copper conductor cable with suitable size from ceiling rose to fitting etc, including taking down existing fitting complete all as specified and as directed. Make : PHILIPS Cat No. Stellar Bright TLED 6500K with Batten or equivalent to C&S/Crompton
Supply and fix in repair LED energy saving surface mounted decorative oval bulk head edge light comprising of high brightness 10W, 6000K LEDs complete with all accessories internally pre wired and including connecting up with twin / three core flexible copper conductor cable with suitable size from ceiling rose to fitting etc, including taking down existing fitting complete all as specified and as directed. Make : LED 10W Bulk Head C&S LTB10WLED or equivalent in Philips / Crompton Greaves.
Supply and fix in repairs LED mirror light fiiting surface mounted type 2 feet x 10W LED complete with all accessories internally pre wired and including connecting up with twin / three core flexible copper conductor cable with suitable size from ceiling rose to fitting etc, complete all as specified and as directed. Make : C&S Cat Part No LTTB2F10WLED/W or equivalent in Philips / Crompton.
Supply and fix in repairs LED square light luminarie fitting surface mounted type 18 W LED complete with all accessories internally pre wired and including connecting up with twin / three core flexible copper conductor cable with suitable size from ceiling rose to fitting etc, including taking down existing fitting complete all as specified and as directed. Make :C&S Cat Part No LTCRSUR18HPLEDSQ/W or equivalent in Philips / Crompton Greaves.
Supply and fix in repairs LED Security light fiiting 15 W LED complete with all accessories internally pre wired and including connecting up with twin / three core flexible copper conductor cable with suitable size from ceiling rose to fitting etc, including necessary suitable clamps & bracket GI Tubing medium grade 1mtr long bend into shape including taking down existing fitting complete all as specified and as directed. Make : C&S Cat part No LTESSE15WLED or equivalent in Philips / Crompton Greaves.
Supply and Fix in repairs battern holder (angle / straight), two pin type suitable for self ballast LED lamps screwed with round block including connecting up with twin / three core flexible copper conductor cable with suitable size from ceiling rose to fitting etc, including taking down existing fitting complete all as specified and as directed. Make: Anchor or equivalent in C&S
Supply and fix in repairs LED lamp 7 W 2 pin complete all specified and as directed. Make : Philips Cat No. CDL & WW : E27 & B22 or equivalent in Philips/Havells
Taking down carefully Electric Energy Meter any type and deposite to MES store all as per specified and directed by Engr-in-Charge.
Fixing only Electric Meter above 25 Amp and connecting to electric circuit with the help of two single core 1100 V grade FRLS insulated unsheathed cables of suitable size multi-stranded Copper conductor FRLS including flexible PVC pipe complete including fixing arrangement , nut, bolt, washers and clamps etc. all as specified and directed by Engr-in-Charge. Note: Electric meter will be issued by Depatment.
S&F in repairs LED Slim wall mounting light fitting 17W 220V all as specifie and directed by Engr-In-Charge Make : Philips Model No - 48027 or equivalent to C&S/ Crompton
S&F in repairs LED track light complete set 12W 220V all as specifie and directed by Engr-In-Charge Make : AEC Model No - AEC 205-18 or equivalent to C&S/ Crompton
S&F in repairs LED track light complete set 18W 230V all as specifie and directed by Engr-In-Charge Make : AEC Model No - AEC 239-30 or equivalent to C&S/ Crompton
S&F in repairs LED track light complete set 30W 220V all as specifie and directed by Engr-In-Charge Make : AEC Model No - AEC 229-30 or equivalent to C&S/ Crompton
S&F in repairs LED bracket light complete set 30W 220V all as specifie and directed by Engr-In-Charge Make : AEC Model No - AEC 135TR or equivalent to C&S/ Crompton
Taking down carefully Light fitting any type for reuse at same place including keeping in safe custody , including refixing light fitting in same position complete connecting from ceiling rose to fitting with 2 core copper flexible cable/conductor complete all as per specified and directed by Engr-in-Charge.
Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized earth Lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No.3 and connected to earth testing point all as specified and directed including testing on completion complete all as specified and as directed by Engr-in-Charge including taking down old complete Earthing system complete all as directed by Engineer-in-Charge. Note No.1: The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 20 mm dia watering pipe, wire mesh, 40mm dia light grade GI protection pipe for earth lead etc., complete
SIRITEL SYSTEMS PRIVATE LIMITED
KRA Engineering and Construction
NLK Construction
VVM CONSTRUCTIONS
GMS Builders
M/s Shana Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .