Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.2 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder. | |
| 2 | L2₹28.8 L+₹35,476 (1.25%)Rejected-Finance 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L2 | Rejected-Finance Not Lowest. | |
| 3 | L3₹34.5 L+₹6.1 L (21.3%)Rejected-Finance 1814 NARSING NAGAR RANJHI JABALPUR MP 482005 | JABALPUR | JABALPUR | MADHYA PRADESH | 482005 | L3 | Rejected-Finance Not Lowest. | |
| 4 | L4₹38.1 L+₹9.6 L (33.7%)Rejected-Finance | L4 | Rejected-Finance Not Lowest. | |
| 5 | L5₹38.2 L+₹9.7 L (34.0%)Rejected-Finance | L5 | Rejected-Finance Not Lowest. |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
4 Jan 2020, 6:00 pmClosed
GE Kamptee
Garrison Engineer, Military Engineer Services, Kamptee Cantt - 441 001
PROVN OF GEYSER, SPLIT AC, LT PANEL, SECURITY LIGHTS, WATER SUPPLY PIPE LINE AND CONVERSION OF OLD LIGHT FITTINGS WITH LED LIGHTS AT KAMPTEE AND REPAIR / REPLACEMENT OF UG CABLE / POLES AT CIVIL LINES NAGPUR.
2019_MES_305031_1
8134/E8
Open Tender
Civil Works
Item Rate
180 days
Kamptee and Nagpur
Class D, Cat b (i) and a (ii)
7 documents required · 7 mandatory
₹500
Yes
GE Kamptee
₹74,000
Yes
25 Jan 2020
9 Dec 2019
6 Jan 2020
10 Dec 2019
4 Jan 2020
25 Dec 2019
10 Dec 2019 - 24 Dec 2019
Amount
Taking down old/ unsv flourescent light fitting complete by disconnecting electrical connection complete all as specified and directed.
M&L for point wiring 1100 volt grade single core FRLSH PVC insulated & unsheathed cable with multistranded copper conductor 2.5 sqmm drawn in electrical grade PVC conduit not less than 20mm dia with IS 9537 (Part-III) 1983 marking medium grade concealed in wall/ ceiling including FRLSH PVC insulated unsheathed earth wire with copper conductor of size 2.5 sqmm pressed steel terminal modular boxes sunk on wall for mounting of switch sockets including modular white cover plate suitable for mounting modular switches, sockets, fan regulator etc with brass screw, cup washer complete all as specified and making good to distrubed surfaces for one independent board point controlled by one, one way switch. Note:- Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate. All switches, fan, sockets, cieling roses and holders shall be connected to common earth dolly.
S&F modular switch 1 way, 6 amp, 250 volts, AC, 1 module complete all as specified and directed.
M&L for sub main wiring 1100 volts grade, single core, FRLSH PVC insulated and unsheathed cable with three run of stranded, copper conductor 4 sqmm drawn in and including electrical grade PVC conduit IS 9537 (Part-III) 1983 marking medium grade concealed in wall/ceiling including PVC insulated unsheathd earth wire with copper conductor of size 4.0 sqmm complete all as specified and directed. Note:- The rate quoted shall be deemed to have included for cutting chasing and plastering as required etc and making good for concealed wiring.
S&F sheet metal enclosure, SPN with two pin, earth plug and socket complete with one single pole MCB's 20 Amps, 240V, rupturing capacity 10 KA, series 'C' complete all as specified and directed.
S&F MCB, single pole, 240 volt, 6 to 40 amps, 10 KA complete all as specified and directed.
S&F MCB, single pole and neutral, 240 volt, 6 to 40 amps, 10 KA complete all as specified and directed.
Fixing & Testing of water heater, storage type, 25 ltrs capacity with rating, single phase, 230 V, 50 Hz electric, supplied and installed including grouting with nut bolts, PVC threaded through flexible pipe / tubing of standard length for inlet/ outlet connection complete all as specified and directed. Note:- Geysers shall be be issued under Sch 'B' from AGE E/M store yard.
S&F 15 mm bore GI tubing, medium grade with all fittings to wall or laid in floors complete all as specified and directed.
S&F 15mm bore stop valves, fancy type, cast chromium plated, high pressure, screwed both ends for iron pipe or for union and fixed complete all as specified and directed.
S&F 15 mm bore bib taps, fancy type, cast chromium plated, screwed for iron pipe or for brass ferrule and fixed to pipe complete all as specified and directed.
M&L for cutting existing steel tubing for alteration or additions of 20mm dia complete with tee complete all as specified and directed.
Installation, commissioning & testing of air cooled split unit air conditioner electric driven single phase of capacity of 1.5 TR, including making all arrangements for fixing indoor & outdoor units, making necessary hole with bracket in wall to pass the tubing and cables and grouting bolt in wall, connecting suction & discharge of copper tubing, gas charge and testing complete all as specified and directed. Note:- Air conditioner shall be issued under Schedule 'B' from AGE E/M store yard.
S&F highly durable surface mounted 18/20 watts LED batten/ surface constructed of fire retardant engineering grade extruded plastic and decorative end cap complete with driver including 3 core 1.0 sqmm copper conductor cable for connection and accessories complete all as specified and directed. Make:- Philips Cat No BN150W LED20S-6500 PSE OD GR / Bajaj Cat No BLTRU 20W NW VIVA / CG Cat No LCTL-18-CDL.
S&F highly durable surface mounted 09 watts LED batten constructed of fire retardant engineering grade extruded plastic and decorative end cap complete with driver including 3 core 1.0 sqmm copper conductor cable for connection and accessories complete all as specified and directed. Make:- CG Cat No LCTL-09-CDL / Philips Cat No Slim Line 9W / Surya Cat No SLW BT 10W / Bajaj Cat No BCLSB 10 WH.
Excavation in trenches for laying of cables, poles, stay, shafts, wells, cesspits, manholes, etc in any type of soil not exceeding 1.5mtr wide and not exceeding 1.50 mtr deep and getting out in soft / loose soil complete all as specified and directed.
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
S&F double wall corrugated high density polymer ethyl (HDEP) pipe for laying of electric cable of size 50mm outer diameter and 38mm inner diameter with IS 14930 (part 2) 2001 and 6mm thickness, laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed. Make:- Ketron / Tirupati / Duraline.
S&F double wall corrugated high density polymer ethyl (HDEP) pipe for laying of electric cable of size 63mm outer diameter and 51mm inner diameter with IS 14930 (part 2) 2001 and 6mm thickness, laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed. Make:- Ketron / Tirupati / Duraline.
S&F double wall corrugated high density polymer ethyl (HDEP) pipe for laying of electric cable of size 120mm outer diameter and 103.5mm inner diameter with IS 14930 (part 2) 2001 and 6mm thickness, laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed. Make:- Ketron / Tirupati / Duraline.
Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 150 sq mm, 3.5 core including testing after laid and jointed complete all as specified and directed. Make:- Polycab / Havells / Finolex.
All as per item No 22 above but size 50 sq mm 3.5 core complete all as specified and directed. Make:- Polycab / Havells / Finolex.
All as per item No 22 above but size 35 sq mm 3.5 core complete all as specified and directed. Make:- Polycab / Havells / Finolex.
All as per item No 22 above but size 10 sq mm 4 core complete all as specified and directed. Make:- Polycab / Havells / Finolex.
S&F LED street light luminaires of capcity 60 watts with pressure die cast aluminium housing heat resistant toughened glass, IP 66 protection complete with driver, with 30x5 mm flat iron clamps, nuts, bolts, washers and fixing accessories including taking down old unserviceable fitting complete all as specified and directed. Make:- CG Cat No. LSTP-60-CDL / Bajaj Cat No BRLEP 60 W LED V2 or equivalent in Philips.
S&F bracket for street light fittings made out of 40mm dia GI pipe of light grade 1.5 mtr long each, bent to shape and size required and fixed to pole with flat iron clamps 02 Nos out of 30x5mm flat iron including GI nuts, bolts, washers and painting of clamps and street light brackets with two coats of aluminium paint over a coat of red oxide primer and fitting brackets to street light fittings including taking down old unserviceable brackets of any shape and size complete all as specified and directed.
Supply & installation of steel octagonal decorative poles 5 mtrs long complete with cast iron base plate, bolts, nuts and screws fixing on foundation with anchor bolts and nuts as specified and directed including plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation filling and mass concrete for stay, poles etc complete all as specified and directed. Note:- Dimensions of foundation concrete will be (LxBxD): 0.5m X 0.5m X 1.5m below ground level and 0.5m X 0.5m X 0.3m above ground level.
S&F thermoplastic cable junction boxes, IP 55/IP65 with metric knockout for cable entry of size 200 x 160 x98 mm, fixing on pole with 30 x 5mm MS clamps, nut bolts, washers, terminal block and glands suitable for 16 Sq mm core cable including 6 amps MCB, SPN complete all as specified and directed. Make:- HENSEL, Neptune, Sintex, Legrand.
S&F 3 core 1.5 sqmm PVC insulated, PVC sheathed, weather proof multistranded copper conductor cable, 1100 volts grade, drawn through GI conduit, on pole complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode of size 600x 600x 6mm thick burried directly in ground (earth plate not less than 2.25mtr deep below normal ground level) with top edge of the plate not less then 1.50 mtr below the normal ground level connected to galvanised earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washer of galvanised iron or steel all as shown in electrical plate No 5 connected to earthing test point all as specified and testing on completion including the material and labour for:- (a) Excavation and earth work or drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 Type B-1. (c) Pre cast RCC cover with suitable handle 40mm thick in PCC 1:2:4 reinforced with welded steel wire fabric weighting not less than 1.87 Kg/sqmm. (d) Funnel with watering pipe of GI 20mm nominal bore medium grade and copper lugs etc all as specified. (e) 15mm nominal bore meduim grade GI protec-tion pipe upto 7.50 metre long for protection of earthing lead. (f) Requisite quantity of charcoal and common salt. (g) Connection to earthing test point and testing on completion.
M&L for earthing complete with galvanized steel earth plate electrode 600x 600x 6mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of earth plate not less than 1.5m below ground level connected to galvanized iron earth strip 30 x 5 mm by means of bolts, nuts, check nuts, washers of galvanized iron and connected to main switch/ control board upto 7.5m away from the earth electrode including excavation earth work, PCC chamber, RCC cover slab char coal, watering pipe, wire mesh lugs, earth lead protection pipe 40mm bore, light grade 7.5m long as applicable and as per plate No. 3 of SSR 2009 and all as specified including: (a) Excavation and earth work in any type of soil. (b) Drilling of holes in electrode. (c) PCC pit in cement concrete (1:2:4) type B-1. (d) 40 mm thick Pre-cast RCC cover with suitable handle. (e) Funnel with watering pipe of GI 20 mm nominal bore, medium grade & copper lug etc. (f) 40mm nominal bore medium grade GI protection pipe 7.50 m long for protection of earthing lead. (g) Requisite quantity of charcoal and common salt. (h) Connection to earthing test point and testing on completion.
M&L for earth continuity conductor or main earthing lead as 4mm dia galvanized iron wire fixed to wall on batten or burried in ground or drawn in conduit /pipe or fixed to pole or any other situation for loop earthing etc complete all as specified and directed.
S&F 15mm dia GI tubes, light grade with all fitting from looping box to street light fitting, fixing with 30 x 3mm MS clamps complete all as specified and directed.
Fabrication, Supplying Installing, testing & Commissioning outdoor type feeder pillar box with rain cowl weather / vermin proof, Indoor type, factory made LT panel, from any CPRI approved manufacturer having dismensions of Suitable size with sufficient space between MCCB cable coonection place and body of panel for easily working to workers including necessary incoming & outgoing cable connections, cable glands thimbles of required sizes, made out of CRCA sheet 3.00 mm thick for outer shell and 3.00mm thick for inner shell duly powder coated paint with inner shutter & outer double door, the cubical shall have a bottom channel of size 75x40x5mm duly coated with zinc metal coating with satinless steel locking handle arrangement both side openable fixed on 50 x 50 x 5 mm MS angle frame fixed 300mm above groud level & 300 mm below the ground grouted in & including PCC 1:3:6 type C1 (using 20mm graded stone aggregate) complete all as specified, directed & comprising of following including refixing existing cables to new panels by proper lugging & cable gland as required. (a) Busbar chamber for 3 phase & nuetral of capacity 300 Amps (30mm x 10mm) alumunium bus bar duly insulated. (b) Multifunctioning meter to measure Voltage, ampere, KWH, PF -1 Nos. (c) one set of LED indication lamp. (d) On load Change Over Switch 4 pole 200 amps Make:- Legrand/L&T/Siemens. (e) Incoming MCCB 200 amps 4 Pole 415 volts 25 KA thermal magnetic setting type- 1 Nos Make:- Legrand/L&T/Siemens) (f) Outgoing Type MCCB 100 amps 3 pole 415 volts 10 KA thermal magnetic setting - 3 Nos Make:- Legrand/L&T/Siemens.
Fabrication, Supplying Installing, testing & Commissioning of outdoor type feeder pillar box with rain cowl weather / vermin proof, Indoor type, factory made LT panel, from any CPRI approved manufacturer having dismensions of Suitable size with sufficient space between MCCB cable coonection place and body of panel for easily working to workers including necessary incoming & outgoing cable connections, cable glands thimbles of required sizes, made out of CRCA sheet 3.00 mm thick for outer shell and 3.00mm thick for inner shell duly powder coated paint with inner shutter & outer double door, the cubical shall have a bottom channel of size 75x40x5mm duly coated with zinc metal coating with satinless steel locking handle arrangement both side openable fixed on 50 x 50 x 5 mm MS angle frame fixed 300mm above groud level & 300 mm below the ground grouted in & including PCC 1:3:6 type C1 (using 20mm graded stone aggregate) complete all as specified, directed & comprising of following including refixing existing cables to new panels by proper lugging & cable gland as required. (a) Busbar chamber for 3 phase & nuetral of capacity 300 Amps (40mm x 10mm) alumunium bus bar duly insulated. (b) Multifunctioning meter to measure Voltage, ampere, KWH, PF -1 Nos. (c) one set of pilot lamp. (d) Incoming MCCB 200 amps 4 Pole 415 volts 25 KA thermal magnetic setting type- 1 Nos. (e) On load change over switch 200 Amps 4 pole - 01 nos. (f) Outgoing MCCB 100 amps 3 Pole 415 volts 25 KA thermal magnetic setting type- 1 Nos. (g) Outgoing MCCB 63 amps 3 pole 415 volts 10 KA thermal magnetic setting - 3 Nos. (h) MCB TPN 32 Amps 3 pole 415 volts 10 KA - 3 Nos.
M&L for cutting of galvanised iron pipe line of 50mm bore for insertion of tees, collars, etc including dewatering work required for working water pipe line complete all as specified and directed.
S&F 50mm dia GI tubes, medium grade with all fitting such as tee, bend, elbow, socket, union to wall or laid in floors / trenches complete all as specified and directed.
All as per item No 38 above but 20mm dia complete all as specified and directed.
S&F in repair gun metal gate valve with iron wheel head, screwed both ends for iron pipe and fiixed to 50mm bore including taking down / removing old unserviceable valve complete all as specified and directed.
All as per item No 40 above but 20mm dia complete all as specified and directed.
S&F 15mm dia bib tap, standard of PTMT, any colour, high pressure, screwed for iron pipe and fixed complete all as specified and directed.
NOTE:- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs.29,020.00]
Paragon Electrotechnics
TRISHLA CONSTRUCTIONS
chronicle enterprises
Vaidehi E Link
Bidder Name
Sharma Electrical and Services
Paragon Electrotechnics
Vaidehi E Link
chronicle enterprises
TRISHLA CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .