CWE LUCKNOW
229 MG ROAD LUCKNOW CANTT
REPAIR/MAINTENANCE/IMPROVEMENT OF 11 KV EQUIPMENT (APFC PANEL/RMU/VCB)AND OTHER CONNECTED WORKS IN AGE E/M (ELECT SUPPLY) UNDER GE (E/M) LUCKNOW
2021_MES_423129_2
CWE/LKO/EM/T-56 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
MES contractors enlisted in Class D and category b(ii) and for unenlisted contractors meeting the enlistment criteria corresponding to value class and category of work and having executed similar nature of work
8 documents required · 8 mandatory
₹500
GE EM LUCKNOW
₹90,000
Yes
13 Apr 2021
19 Mar 2021
3 Apr 2021
19 Mar 2021
2 Apr 2021
21 Mar 2021
Amount
Disconnecting the all elecrical connection and taking out the unserviceable components from APFC panel 125 KVAR Make : Schneider and fixing only the following new components of the APFC panel incl testing complete all as specified and directed. Note- (i) If any part is missing in the tender, the tenderer shall visit the site before quoting the tender and include the rate for the same in the quoted rate. (ii) Any civil work required at site to be included in the quoted rate. (iii) Retro fitment job at site to be carried out by only panel make company engineer. (iv) Power factor correction system shall be got tested by the contractor from Govt approved agency at manucfactuer premises, test roport /inspection report will be sent to GE.
Supply only 250 Amp 3 pole MCCB 36 KA, built in μP based trip unit having protection functions LSIG, Variable current setting for L,S,I and G and variable time delay setting for L,S and G. Last fault trip history on LCD screen of MCCB i.e faulty phase, type of fualt and interrupted current with ROH + spraders etc Cat part No (LV525620+LV431563+LV429338) complete all as specified and directed.
Supply only 6 stage APFC relay-varlogic APFC relay- classic range (cat part 51207)
Supply only VAF, PF meter (cat part No 30002567)
Supply only LED lamp red direct integral LED 230 volts (cat part No XB7EVO04MPN)
Supply only LED lamp green direct integral LED 230 volts (cat part No XB7EVO03MPN)
Supply only LED lamp yellow direct integral LED 230 volts (cat part No XB7EVO05MPN)
Supply only Single pole MCB, 20 Amp 10 KA (Cat part No A9N1PO2C)
Supply only Current Transformer 250/5A, Class-1.0, 10 VA
Supply only 63 Amp MCCB 3 pole 36 KA, CVS TMD type (cat part NO LV510335) for 25 KVAr
Supply only TVS E type, TP, power contactor 50 Amps (cat part N0-LC1E50M7) for 25 KVAr
Supply only Var Plus Max Al detuned reactor 25 KVAr 440 &% 50 HZ (cat part No LVRO7250A44L0) for 25 KVAr
Supply only Capacitor VarPlus box energy (MD-XL) 440V range 25 KVAr (cat part No MEHVBENY250A44) for 25 KVAr
Supply only 32 Amp MCCB, 3 pole 36 KA, CVS TMD type (cat part No -LV510332) for 10 KVAr
Supply only TVS E type, TP power contractor 32 Amp (cat part no LC1E3210M7) for 10 KVAr
Supply only VarPlus Max AL detuned reactor 10 KVAr 440 7% 50 HZ (cat part No LVRO7100A44LO) for 10 KVAr
Supply only Capicitors- VarPlus box Engergy (MD-XL) 440 range 10 KVAr (cat part No MEHVBENY100A44) for 10 KVAr
Supply only 16 Amp MCCB 3 pole 36 KA CVS TMD type (cat part No LV510330) for 5 KVAr
Supply only TVS E type TP power contractor 18 A (cat part No LC1E1810M7) for 5 KVAr
Supply only Var Plus Max AL dentuned reactor 5 KVAr 440V &% 50 HZ (cat part No LVRO7050A44LO) for 5 KVAr
Supply only Capacitor VarPlus box energy (MD-XL) 440 range 5 KVAr (cat part No MEHVENYO50A44)
Repair/maintenance of transformer distribution panel and disconnecting the electrical connection from unserviceable parts and taking out the unserviceable material from the panel and fixing only the new material as per existing make/model/capacity and paiting with one coat of hammer tone synthetic enamel paint, nut bolt,washer and suitble size aluminium lugs, repair of door hinges, replacing the worn out portion incl welding etc complete all as specified and directed. Note :- (i) The rates quoted by the contactor shall be deemed to be included the cost of any other spare parts that are not mentioned herein after but essentially required for functioning of the system. (ii) Unit rates quoted by tenderers shall deem to include for, bolts, washers, lugs, thimble, wires and petty items required for efficient and smooth functioning of the equipment without any extra cost to the Govt.
Supply only MCCB 4 pole 50 KA 630 Amp with thermal & magnetic release.
Supply MCCB 4 pole 36 KA 250 Amp with thermal & magnetic release
Supply only MCCB 3 pole 36 KA 250 Amp with thermal & magnetic release
Supply only MCCB 4 pole 36 KA 200 Amp with thermal & magnetic release
Supply only MCCB 3 pole 36 KA 200 Amp with thermal & magnetic release
Supply only MCCB 4 pole 36 KA 160 Amp with thermal & magnetic release
(g) Supply only MCCB 3 pole 36 KA 160 Amp with thermal & magnetic release
Supply only MCCB 4 pole 18 KA 125 Amp with thermal & magnetic release
Supply only MCCB 3 pole 18 KA 125 Amp with thermal & magnetic release
Supply only MCCB 4 pole 18 KA 63 Amp with thermal & magnetic release
Supply only MCCB 3 pole 18 KA 63 Amp with thermal & magnetic release
Supply only MCB TPN 10 KA 63 Amp `C' curve
Supply only MCB TPN 10 KA 40 Amp `C' curve
Supply only Digital Voltmeter
Supply only Digital Ammeter
Supply only LED Indicator
Slector switch
Current transformer for measuring the current as per existing make/model/capacity and ratio
Prediodical servicing of air circuit breaker and disconnecting the electrical connection from unserviceable parts and taking out the unserviceable parts from the ACB and fixing only the new parts as per existing make/model/capacity incl cleanding and greasing fixed and moveable parts etc complete all as specified and directed. Note :- (i) The rates quoted by the contactor shall be deemed to be included the cost of any other spare parts that are not mentioned herein after but essentially required for functioning of the system. (ii) Unit rates quoted by tenderers shall deem to include for, bolts, washers, lugs, thimble, wires and petty items required for efficient and smooth functioning of the equipment without any extra cost to the Govt.
Supply only Shunt release
Supply only Under voltage release
Supply only Earth fault release
Supply only Remote fault indicator
Supply only Microswitch for indication
Supply only lockable trip push botton
Supply only locking ACB in isolating position
Supply only locking ACB in any position
Supply only racking interlock
Supply only door interlock
Supply only mechanical operation counter
Supply only Mounting kit for front mounted counter
Supply only spring charge indication microswitch
supply only racking pad lock assembly
Supply, installation, testing and commissioning of LT distribution board cubical & indoor type factory made CPRI tested, dust and vermin proof fabricated to 2 mm thick CRCA sheet size of panel as per manufacturer norms and mounted on angle iron and T section frame of size 50x50x6mm and double door front/rear opening and locking arrangment floor mounted, bus bar chamber with 1000 amps capacity aluminum bus bar fixed on post insulator inclduing painting with powder coated as specified and pre-wired with suitable size PVC insulated sheathed copper conducotr cable incl taking down old one LT panel and earth & PCC works complete in all respects with and including the following :-
One No - Air circuit breaker electrical 4 pole draw out with microprocessor release with ITD,STD instantaneous, ground fault & IED indication, auxillary switch, main CTs for polyester resin cast CTs-800/5, ATB 064 for 3 phase & ATB-060 for neutral, safety shutter, 36 way auxillary isolating contacts, AC/DC charging motor, closing coil, shunt trip, anti-pumping relay, micro switches as required for electrical operation under voltage trip device (UVT coil with 500 msec time delay upto 1600 Amp) with spare parts as per manufacturer list complete of capcity 630 amps Make : Siemens/L&T/ABB
Excavation in trenches, n. exc 1.5 m wide and n. exc 1.5m depth and getting out for foundation of pole,stay,laying of cable and pipe etc in any type of soil complete all as specified and directed.
Returing, filling in including spreading, levelling, watering and well ramming in layers n exc 25cm thick after laying of the cables, jointing & testing complete all as specified and directed.
Removing excavated material to a distance n.exc 50 m & depositing where directed at a level n. exc 1.50 m above the starting point complete all as specified and directed.
M&L for sand cushioning in trenches spreading and consolidation 8 cm thick before laying the cable and 15 cm thick after laying the cable but will be measured 18 cm thick only after punning etc complete all as specified and directed.
M&L for laying of bricks well burnt sub class B (old pattern) laid flat for cable protection with width equal to the length of bricks complete all as specified and directed
Supply, laying, jointing & testing in repair PVC insulated armoured electric cable with aluminium conductor heavy duty, conforming to IS 1554 Part I / ISI marked, including cable glands, cable lugs etc, suitable for the cable size, cables to be laid in trenches, fixed along the poles bare or through GI pipe laid under floors road etc fixed concealed in walls encased in GI pipe etc as required at site for the following sizes :-
240 sqmm 3.5 core
185 Sqmm 3.5 core
150 sqmm 3.5 core
95 sqmm 3.5 core
70 sqmm 3.5 core
50 sqmm 3.5 core
M&L for earthing with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 metre deep below ground level) vertically, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to galvanized iron strip 32x6mm by means of nuts, bolts, washers of GI steel all as shown on electrical plate No 3 of MES Schedule Part I connected to earthing test point and testing on completion with and including necessary excavation and earth work, earth electrode, earthing lead from electrode to equipment/substation, adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover, reinforced with 6mm dia bars 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 20 mm dia with CI funnel and wire mesh, and 40 mm dia GI light grade earth lead protection pipe, complete all as specified and directed. Contd...
Note : (i) Main earthing lead from earth plate electrode to test point upto length of 7.50 mtr shall deem to be included in the unit rate quoted by the tenderer against this item. (ii) GI protection pipe and earthing strip beyond 7.5 mtr long shall be measured and paid seperately. (iii) Test result should be less than 1 ohms or satisfaction of user. (iv) Material should not be less than 60 Kg Coal and 100 Kg Salt in each earthing.
M&L for disconnecting burnt end or portion of 50 sqmm to 185 sqmm 3 ½ core cable removing the cable from loop including necessary excavation, earthwork, removing brick protection and relaying same bricks and filling the earth and reconnecting the cable by removing burnt portion of cable and preparing fresh terminals of LT/HT cable to transformer/panel/pole etc complete all as specified and directed.
M&L 60mm thick PCC interlocking tiles, rubber moulded using grey cement and pigment of size and shape as approved, including 50mm thick bed with PCC (1:3:6) type C1 using 20 mm graded stone aggregate and including layer of dry sand not less than 40 mm thick, interstices filed in floors/pathway including locking the tiles on all four sides with PCC complete all as specified and directed.
M&L for surface dressing n exc 15mm deep etc complete all as specified and directed.
M&L for 100 mm thick plain cement concerete 1:3:6 type C2 (using 40mm graded stone aggregate) complete all as specified and directed.
Servicing to 11KV HT VCB/RMU any type complete with and including the following:- (a) Taking out 11KV HT VCB/(SF6 type) of 400/800 Amps rating from RMU Panel after switching off electric supply.Checking of mechanical system for proper functioning of upward/downward movement of HT VCB/(SF6 type)+D35 including opening the VCB/(SF6 type) & checking the mechanical system.Cleaning & servicing the fixed/ moving contact & blowing out dust and applying the proper lubrication/greasing and reassembling the VCB/(SF6 type) including connection to HT panel complete insulating oil to be replaced where reqd complete all as specified and directed. (b) Taking out relay set (2 Nos over current & 01 No earth fault relay) of any make from HT11KV VCB/(SF6 type) panel and cleaning the contact (NO+NC) by CTC solution and adjust the contact and calibrate the relay by relay testing kit & proper plug setting as per reqd load & time delay and fixing the relay set in HT panels complete all as specified and directed by EIC. Note for (a) & (b):- (i) Testing of above job to be carried out by engineers of authorised dealer/service centre of concerned OCB (ii) Replacing new items shall be measured and paid separately as supply only . (iii) Contractor shall submit the connected document/graph for relay calibration duly authenticated by authorised dealer / service centre). The rates quoted by the contactor shall include cost of any other spare parts/relay not mentioned hereinafter but essentially required for functioning of the system. No extra payments will be made for the spare parts/relay.
Supply only shunt trip coil assembly suitable for VCB, operating on 30/110 volt system and testing complete all as specified and directed.
Supply only closing/tripping coil operated on 110 /30 volt system suitable for working of relay of VCB complete all as specified and directed.
Supply only spring charging motor suitable for fixing with 11 KV indoor type VCB panels complete all as specified and directed.
Supply only charging bottles suitable for 11 KV VCB at RMU complete all as specified and directed.
Supply only moving contacts of VCB at RMU made of copper and suitable for 11 KV VCB compete all as specified and directed.
Supply indicator light (LED type) suitable to operate on 30 volts DC/110 V AC having two covers red/green/blue for RMU panel including taking down old one compete all as specified and directed.
Supply only cast regin wound CT as per existing ratio/make/model/capacity
Supply only Elstein HFS panel heater 300 watt suitable for 11/33 kv VCB for removing the moisture
Supply only VCB 630 Amps 11 KV with trolly for housing in existing panel as per existing model/make/capcity/size
Supply only relay as per existing make/moede/capacity
S&F cable joint kit for 11 KV (earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories sutable for XLPE armoured aluminium conductor cable of size 50-95 sqmm complete all as specified and directed.
S&F cable kit for 11 KV (earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories sutable for XLPE armoured aluminium conductor cable of size 120-185 sqmm complete all as specified and directed.
S&F cable joint kit for 11 KV (earthed) grade cable for out door termination heat shrink type joint with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 50-95 sqmm complete all as specified and directed.
S&F cable joint kit for 11 KV (earthed) grade cable for out door termination kit heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 120-185 sqmm complete all as specified and directed.
S&F cable joint kit for 11 KV (earthed) grade cable for end termination indoor heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 50-95 sqmm complete all as specified and directed.
S&F cable joint kit for 11 KV (earthed) grade cable for end termination indoor heat shrink type joint complete with jointing material and accessories suitable XLPE armoured aluminium conductor cable of size 120-185 sqmm complete all as specified and directed.
Hiring of cable fault detector machine to detect exact position of faulty XLPE /PVC HT cable, 11000 Volts grade heavy duty aluminium conductor of any size and any length including excavation, relaying of protection cable cover, & removing and earth filling etc complete all as specified and directed. Note : If any defect occurred at any place of Lucknow cantt area, the contractor will provide mechanic & fault locator with material within one hours for rectification of defects. If the contractor does not provide the mechanic and material within schedule time, the amount will be deducted @ Rs 1000/hrs after receiving phone/message/ whatsapp /email etc complete all as specified and directed.
M&L for spraying the chemical (Roundup) in the premises of sub station in the ratio 1: 3 for buring the grass at every three month all as specified and directed.
DEV INFRATECH
M/s Shiksha Enterprises
Sanjai sales and services
M/S NATIONAL ELECTRIC WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .