Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance R 1 BEHIND MOTOR AIDS PETROL PUMP SWARG SHASTRI NAGAR JHOTWARA ROAD VILLAGE TOWN JAIPUR CITY JAIPUR JAIPUR RAJASTHAN 302016 INDIA | JAIPUR | RAJASTHAN | 302016 | Admitted-Finance |
| 2 | Admitted-Finance B 16 SHREEJI NAGAR DURGAPURA JAIPUR RAJASTHAN 302018 | JAIPUR | RAJASTHAN | 302018 | Admitted-Finance |
Tender Value
₹57 L
EMD Value
₹1.1 L
Closing Date
27 Jul 2023, 5:00 pmClosed
Commissioner, DoIT and C
IT Building, Yojana Bhawan Campus, Tilak marg, Jaipur
RFP for Additional work of Furniture, Civil and MEP at Makeshift JVNU Campus, Jodhpur
2023_DoIT_348117_1
F11(24)/DOIT and C/Prj/2023/ ML-973/ 2023
Open Tender
Miscellaneous Works
Item Wise
90 days
as per RFP
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,500
Commissioner, DoIT and C
₹1.1 L
Yes
LIC Building
4 Aug 2023
7 Jul 2023
28 Jul 2023
7 Jul 2023
27 Jul 2023
14 Jul 2023
12 Jul 2023
Amount
Furniture works
SITC of 3-Seater Sofa The top shall be of Upholstery with PU Finish. The sofas are made of solid wood base, reinforced with supportive addendum in the seat. Engineered wood panels form/support the overall design structure, they synergize with the solid wood to offer unparalleled life to the product. Foam padding of multi-density and varying thicknesses provide cushion for the sofa. PU foam used is made Hennecke foam plants using German Technology capable of producing the high-quality flexible polyurethane foam. It provides unparalleled comfort, ease of use and durability. The foam used is 32 Density for seating areas and 28 Density for backrest. The super soft foam used is in seating areas in 32-35 Density High-resilience (HR) foam which is unique and rarely used by manufacturers. Webbing: Interwoven high tensile elastic bands for optimum comfort and endurance. Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
SITC of Conference table 1) Conference furniture’s top shall be of 25 mm thick MDF board. 2) The working side edge: - Audit certified design feature (from UL / Intertek / NABL / reputed test laboratory) on front modular Polyurethane (PU) Edge. High density Poly Urethane Foam moulded on industrial grade aluminum core to form minimum 50mm deep tapered edge to be installed on worktop. The edge shall be mechanically replaceable within 30 minutes in case of damage or wear without opening or removing the top. 3) Legs: Ergonomically designed and matching with the open office concept. The leg is made out of metal sheet. 4) Under structure pipe shall be made up of minimum 1.6mm thick CRCA Laser cut components, powder coated with the matching shade/color/finish. 5) Cable tray: Shall be made up of 1mm thick CRCA sheet, Cable tray is used for running the wires between the desk. Powder coating as per RAL shade incompliance with IS standard (CRCA sheet: IS 513, Powder Coating ISI 01). Provision of switch socket and wire flow can be made as per requirement of Engineer in charge. 6) Accessories: Flap with SITC of Switch and Socket and wire flow as per the direction of engineer in charge. 7) The manufacture shall be FSC certified. 8) The table shall be Greenguard gold tested/certified (from UL / Intertek / NABL / reputed test laboratory). Approximate minimum Dimensions – 4000mm (W) X 1200mm (D) X 750mm(H) Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
Civil works
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete:
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required. 0.80 mm thick with zinc coating not less than 275 gm/m2
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete. 75mm thick with 20mm thick nominal size aggregate.
Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5 m , disposed earth to be levelled and neatly dressed : All kinds of soil
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Providing and laying Random rubble dry stone Kharanja under floor.
Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation, footing, strap beam, raft, bases of column etc. ( Footings and Plinth Beam & Column)
Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level.- Thermo-mechanically Treated bars (Conforming of relevent IS code)
Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1 cement : 4 coarse sand)
Providing and fixing Chicken mesh jali (22 gauge) at the junction of 2 different surfaces of different material component at the time of plastering to prevent cracking in plaster surface as and where directed at all floors with all leads and lifts etc.complete.
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: Two or more coats on new work including prepartion of base with primer complete in all respect.
Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete.
Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm).
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : One or more coats on old and New work.
Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 4 (1 cement : 4 coarse sand)
Half brick masonry in Superstructure , above plinth level upto floor V level using bricks of designation 75 Cement mortar 1 : 4 (1 cement : 4 coarse sand)
Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.
Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite/Kota Stone Work Full Edge moulding
Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete
Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete
Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 5 KM lead as per direction of Engineer-in-charge:
Supply and Installation of Water/Door matt Material: Polyvinyl Chloride, Color: Grey Shape - Rectangular
Supply and Installation of Glass stand Material: Polyvinyl Chloride,
Supply, Printing and installation of Main Exterior Signage - 3mm ACP Sheet mounted on 1.5"x1.5" MS Square pipe with heave iron angle with "RAJIV GANDHI FINTECH DIGITAL INSTITUTE" & "Logo" in embosed acrylic letters & remaining matter in 3mm thick Black & red acrylic cut letters(Nonlit)
Providing and fixing wall poster on wall/paneling of 3mm thick Sunboard sheet with Digital printed vinyl (HP Latex 570 model) in high quality mode.
P & F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor : 1.0 mm thick stainless steel AISI -304 & IS 13983-1994 kitchen sink of approved make as per Engineer-in-charge with large waste coupling. Size :- 45 x 20 x 8 20x16x8 (with drain board)
Providing & fixing WVC JAVA Wash Basin (1st quality, IS: 2556 mark) of approved make with C.I. Brackets duly painted, 1.No.15mm C.P. Pillar cock (I.S.: 8934 mark) & 32mm C.P. brass waste coupling of approved make, 25mm G.I. waste pipe complete including cutting and making good the wall : Size 560 mm x 475 mm.
Providing & Fixing Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin etc. C.P. Inlet connection 15mm.Brass (IS : 8931 marked)
Providing and fixing Superior quality CP Brass fittings of approved make as per direction of Engineer-in-charge Pillar Cock 15 mm nominal size
Providing and fixing Superior quality CP Brass fittings of approved make as per direction of Engineer-in-charge Bib Cock 15 mm nominal size
Providing & Fixing PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design:1000 litres capacity.
P & F Liquid Soap Container with brackets complete of approved make: C.P. brass
Providing & fixing of uPVC SWR pipes (Type-A) conforming to IS 13592 along with all required fittings like tees, bends, crosses with or without access doors jointed with approved solvent cement fixed to walls with clamps complete including angle supports, brick work (slab/beam/wall) and making good the floors and walls with cement mortar where required complete of outer diameter.
75 mm dia
110 mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge. (External work).
25 mm dia.
32 mm dia.
40 mm dia.
Providing and fixing non return valves with complete in all respects.
40 mm dia.
50 mm dia.
Providing and fixing BRASS ball valve with cenemnt solvant complete in all respect..
40 mm dia. nominal bore
50 mm dia. nominal bore
Providing and fixing uPVC Floor Drain with PVC grating 75 mm dia. or 75 x 75 mm square with frame complete in all respects. Floor drain: Size 110 X 90 mm
Providing & Fixing Grating of approved quality/make: Stainless Steel Sheet Square 150 x 150 x 8mm. (Anti Cockroach)
Excavating trenches of required width for pipes, cables, etc including excavation for sockets also including for cement concrete cradles, and dressing of sides, ramming of bottoms, depth up to 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50 m.
Pipes, exceeding 80mm dia but not exceeding 300mm dia in all types of soils.
Providing and laying cement concrete 1:5:10 (1 cement : 5 fine sand 10 graded stone aggregate 40 mm nominal size) all-round S.W pipes including 150 mm thick bed concrete as per standard design.
150 mm dia
Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.: Size 300 Cm. dia outside & 300 Cm. depth .
Constructing brick masonry rectangular type manhole of size given below and depth as per the drawing in cement mortar 1:4 (1 cement : 4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and outside rough cement plaster 15 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement all complete as per standard design.
MEP works
SITC of Radiator Cooled and Turbo charged Silent DG Set (As per latest CPCB emission norms) having specifications as per A, B, C, D, E, F,G,H & I A) 1500 RPM Diesel Engine conforming to BS:649/5514 of suitable BHP (up to 82.5 kVA 6 cylinder or Below required, 125 kVA & Above ratings 6 cylinder or above required ) capable of taking 10% over loading for one hour after 12 hours of continuous operation., Dry exhaust mainfold with Hospital grade silencer and catalytic convertor(isolated from main DG chamber), up to 3 M exhaust piping (with LRB insulation & Alum. cladding ) as required . B) AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS/IEC 60034-1. . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).Engine & Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled C) CPCB / ARAI approved Standard canopy with Weatherproof, powdercoated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with sidewall fabricated from 1.6 mm CRCA sheet & filled with glasswool (96Kg/m3) / Foam. as per IS8183 the doors of 28/40/50/85mm thick as perrating and fabricated from 1.6mm CRCA sheet packed with accoustic material, All doors/opening are sealed with neoprene /EPDNgaskets. The DG Set has Inbuilt / External in fuel tank to run 6 to 8 Hrs as per OEM standard, with protection and tripping of DG set against temperature of more than 50 degree centigrade.
D) Electronic / Mechanical governor, Manual & electric Start ,Batteries with battry charger, Engine instruments panel,AVM pads All controls for operation of DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring like Running Hour, RPM, Low Lube Oil tripping & control system, Panel mounted MCCB/ACB of suitable rating, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level shall be less than 75 dB at a distance of 1 Mtrs. duly certified by authorised agency etc. complete in all respect of following capacity : E) (i) Accoustic glass wool wall thickness should not be less then 40mm and not less then 20mm PU foam upto rating 100 KVA. (ii).Accoustic glass wool wall thickness should not be less then 65mm and not less then 50mm PU foam upto rating 250 KVA. (iii)Accoustic glass wool wall thickness should not be less then 100mm for rating above 250 KVA. F) First filling of the fuel tank shall be done by contractor and the prevailing fuel cost at that time shall be reimbursed to the contactor by department. G) Servicing Contract of DG Set from OEM's Authorised Service Dealer as per OEM guidelines during the DLP period shall be done by contractor including all consumables, actual charges shall be reimbursed to the contractor by End User Department. H) Manufacturer / OEM must have its authorized service dealer in Rajasthan. Which can provide service within 6 Hours of compalint registration.
I) DG set will be offered for Inspection and Testing at Manufacturer's Works in presence of Departmental Engineers. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached as per PWD Electrical BSR 2022 . j) Suitable for synchronization
160 KVA at 0.8 pf 415V 50Hz 3-ǿ
Audio System for classroom
In ceiling speaker shall have 6 Inches HD Driver and 1 inch High Frequency Driver. It shall have a frequency response of 100 Hz to 20,000. The speaker shall have a 16/8 Ohm as well as 70V/100V Taps. It shall have a Transformer tapping of 30/20, 15/10 Watts or better. It shall have low impedance RMS Power of 30 Watts or more. It shall have a maximum SPL of 101dB. Below that would not be accepted. It shall have metal front grille.
Wireless Omni Directional Lapel Microphone having Frequency Modulation and Operating Range of 100 m or more. It shall have THD of ≤ 0.9% or better. It shall have frequency response of 50 to 16,000 Hz (–3 dB) or better. It shall have Squelch Control. It shall have Balanced XLR Audio output and Unbalanced Audio Output. It shall have Operating Time of 8 Hours or more. It shall have maximum audio level of 12 dB or more. It shall have rated impedance of 1 ohm or better. It shall be supplied as 1 receiver, 1 bodypack transmitter, 1 clip on Microphone, 1 power adaptor, 1 AA batteries, and 2 receiver antennas complete in all respect.
Mixing Channel Amplifier which shall be 240 Watts or more. It shall have Microphone frequency response of 40Hz- 17000Hz or better. It shall have a Line Frequency Response of 40 Hz-18000 Hz or better. It shall have minimum impedance load bridged of 4 ohms per channel. It shall have 4 or more balanced microphone inputs. It shall have 2 or more-line inputs. It shall have 4 numbers individual phantom power for all microphone inputs. It shall have 1 unbalanced Line output or better. It shall have input sensitivity of ± 2.5 mV/ 2k ohm for balanced Microphone inputs. It shall have input sensitivity of 1000 mV/10kOhm, Unbalanced RCA Input for AMP input. It shall have input sensitivity of 350mV/10k ohm for unbalanced Aux input. It shall have an output sensitivity of 200mV/470 ohm for record output. It shall have 100V line, 70V line as well as 4-to-16- ohm impedance output. It shall have THD of >0.1% at 1 KHz, 1/3 rated Power or better. It shall have Microphone input overload of fifteen db or greater. The microphone inputs shall override over other audio inputs by 30 dB attenuation via switch. It shall have a gain control of ± two and half millivolt to ± seventy-five millivolt @ thirty dB. It shall have a cross talk of less than or equal to fifty dB or better. It shall have high temperature, overload and short circuit protection. It shall get operated from AC as well as DC. It shall be supplied with 60 meters Speaker Cable and 10 meters Audio Cable. Digital Signal Processor Digital Signal Processer with inbuilt Acoustic Echo Cancellation which shall have 6.5mm Line Input and Line Output Terminal. It shall have USB Type-B Audio Port. It shall have Echo Cancellation ≥68dB. it shall have Signal to Noise Ratio: 84dB or better. it shall have Full duplex, Two-way communication. It shall support Noise Reduction & AGC.
Supply & Installation of IP-20 & IK-08 , UL Listed Wall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with 'U'Marking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19" angles with wall mounting provision on wall. Accessories like: 1 No of 19" 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19" 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastner etc as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with Electrical BSR 2022 .
9 U Rack with Width 600 mm & Depth 400 mm + 100 mm
Supply, Installation, Testing & Commissioning- Podium with Gooseneck mic made of high-quality metallic sheets powder coated/ good finish with cooling fans, louvers for heat dissipation, caster wheels. 21.5 Inches Touch Screen Display with Full High-Definition Resolution. Front Height- 40- inch, Height (Presenter side)- 42-inch, Width- 24-inch, Depth- 21 inch. Podium to be supplied with gooseneck Microphone with pre polarized Condenser mic with cardioid Pickup Pattern, XLR connectivity and 130dB or more SPL.
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached With Electrical BSR 2022.
Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring, Compression Nut, heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as per IS 8337-1976 of following size of PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
3.5 x 150.0 sq.mm
3.5 x 185.0 sq.mm
S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached as per PWD Electrical BSR 2022.
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached as per PWD Electrical BSR 2022.
3x 1.5 sq.mm
2 x 2.5 sq. mm. + 1x1.5 Sqmm
Wiring of light point/Fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached as per PWD Electrical BSR 2022
Medium point (up to 6 mtr.)
Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification of Wiring accessories refer Chapter E - 07 related item & For additional technical parameters of product / work refer Annexure 'A' attached as per PWD Electrical BSR 2022
Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached With Electrical BSR 2022 .
Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached With Electrical BSR 2022 .
30mm x 5 mm copper strip with PVC Sleeve
32mm x6mm G.I. ( Hot Dipped ) Strip
160 to 200 KVA
Providing & Fixing of of BLDC Technology ventilating fans , single phase with PVC impeller, ABS body, Double Ball bearing, automatic back lower shutter including making connection, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with Electrical BSR 2022 .
200 mm sweep with Min. Air delivery 800 cmh, 1600 RPM
Providing & Fixing of IP 20 box made out from 1.2mm thick CRCA sheet steel with depth of minimun 30 mm and finished with powder coating and suitable for mounting LED tube including side covers, holders , internal wiring to illuminate the single sided connection LED tube. ( Without tube). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with Electrical BSR 2022 .
Suitable for 4' LED Tube shape fixture for single rod
Supply , Installation, Testing and Comissioning of Inverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and 50 hz , single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached With Electrical BSR 2022 .
1.5 TR ISEER not less then 4.6
2.0 TR ISEER not less then 4.6
SITC of wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as per TTA & PTA specification for electrical Works, made out of CRCA sheet . Other parameters required as per point (a) ,(b), (c)below:- (a)Thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors with / without detachable extension type structure (b)panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware, separate detachable gland plate M.S. base channel (min75mm) , hinged door with locking arrangement for equipment/switchgear [c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 125 amp ) and by solid bus bar (>125 amp ) . All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar.
100kVAR APFC PANEL TTA PANEL AS PAR IEC-61439 Incomer : MCCB 200 A 3P 25 Ka TM Based - 1 Nos External Rotary Handle for MCCB- 1 Nos Spreader link for MCCB- 1 Set Digital Multifunction meter CL1.0 with RS485- 1 Nos CT-200/5A, CL-1, VA-15VA for metering- 3 Nos CT short Link- 3 Nos R,Y,B Indication Lamp 230 V AC- 3 Nos 6A SP MCB C-Curve , 10 kA- 3 Nos Neutral Link- 1 Nos 12 Stage APFC Relay 3 CT- 1 Nos Exhaust Fan with Air Filter
Eminent Colonizers Private Limited
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .