| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.2 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹33.8 L+₹1.6 L (4.95%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹35.0 L+₹2.7 L (8.49%)Rejected-Finance C O PRAMOD KUMAR SHAH BUS STAND NANDPRAYAG NANDPRAYAG CHAMOLI UTTARAKHAND 246429 | NANDPRAYAG | CHAMOLI | UTTARAKHAND | 246429 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹35.6 L+₹3.3 L (10.4%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹37.7 L+₹5.5 L (17.1%)Rejected-Finance CHATAI SHEEP WARD NO 07 NEW MARKET ROAD AHIWARA DURG CHHATTISGARH 490036 | DURG | CHHATTISGARH | 490036 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹43.2 L
EMD Value
₹87,000
Closing Date
19 Mar 2024, 6:00 pmClosed
Garrison Engineer Gwalior
Garrison Engineer Gwalior Morar Cantt
8944/GWL/E8 PROVISION OF DRAINAGE SYSTEM AND OPEN MT SHED WITH HARD STAND IN THE AREA OF AGE B/R-II AT MORAR CANTT GWALIOR
2024_MES_643253_1
8944/GWL/E8
Open Tender
Civil Works
Works
180 days
Garrison Engineer Gwalior
Please refer tender documents
9 documents required · 9 mandatory
₹500
Garrison Engineer Gwalior
₹87,000
Yes
13 Jun 2024
20 Feb 2024
21 Mar 2024
20 Feb 2024
19 Mar 2024
6 Mar 2024
Amount
M&L for Surface Excavation n.exc 30 cm deep of avg 15cm in Hard /dense type soil and getting out complete all as specified and directed.
Add or deduct above item No 1 for every 3 cm or part thereof above or below 15cm average complete all as specified and directed.
M&L for rolling and consolidating formation surfaces in cutting with power roller of capacity exc 8 tonne and n.exc 12 tonne complete all as specified and directed.
M&L moorum /red bajri filling in floors or paving laid in layers n.exc 15cm thick spread leveled and rammed including watering complete all as specified and directed.
M&L for hard core of broken stone of gauge not exceeding 63 mm, deposited, spread & levelled in layers n.exc 15 cm thick watered and rammed to a true surfaces complete all as specified and directed.
M&L for PCC (1:4:8) Type D2 (using 40mm graded stone aggregate) as in foundation filling mass concrete complete all as specified and directed.
M&L for 125 mm thick PCC (1:2:4) Type B2 (using 40 mm graded stone aggregate) as in levelling course/mass concrete, Finishing surface of concrete toping even and smooth without using extra cement including necessary formwork complete all as specified and directed. Note: Rate of formwork included in above mentioned item, PCC will be casted in 4mX4m Panel using MS angle or channel formwork laid in alternate panels or directed by Engineer In Charge.
M&L for forming 12mm thick expansion joints filled with pre-formed bituminous filler and to 30mm primed and sealed with sealing compound, grade 'A' thickness 100mm complete all as specified and directed.
S&F for Pre painted galvalum sheet 0.50 mm thick having aluminum zinc coating 150 gsm/sqm steel sheet any colour having tensile strength of 550 Mpa as in Roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed.
M&L for excavating in posts holes (or similar holes) in hard/dense soil each n.exc 0.50 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25cm thick each layer, watering, and removing surplus soil to a distance n.exc 50m and making good surface complete all as specified and directed.
S&F for rolled section as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates confirming to Fe-290 (Gde E-165) complete all as specified and directed.
M&L for Hand rails, half round or other stock section or core for wooden hand rail straight portion, drilled and counter sunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing post including cutting tops to shape as directed, drilling holes, notching for wire, etc flat iron fillets (for securing wire mesh etc including all necessary drilling, bolting or rivetting, etc, and similar work conforming to Fe-290 Gde E-165 with and including applying two coats of synthetic enamel paint over a coat of primer alround before fixing in position complete all as specified and directed.
S&F Framed work ORNAMENTAL AND INTRICATE DESIGN such as grills,gratings, etc with ends of barss shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework of water tanks and similar work conforming to Fe-290, Gde-E-165 complete all as specified and directed.
M&L for preperation of new surface and applying two coats of synthetic enamel paint over coat of Red oxide primer over new surfaces n.exc 10 cm width or girth complete all as specified and directed.
M&L for applying for two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces over 10 cm width or girth including preparation of new surfaces complete all as specified and directed.
M&L for Brick work with sub class B bricks straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and as directed.
M&L for rendering 10 mm thick in CM (1:4) on fair faces of brick work or conrete surfaces/stone masonary and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered sufaces of walls & applying 2 coat of cement base paint over a coat of primer complete all as specified and directed.
M&L for random rubble uncoursed masonary, well bounded, bedded and solidly hearted built in cement mortar 1:6 complete all as specified and directed.
M&L for flush pointing to RR masonary walling brought upto course in CM (1:4) complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in coping, kerb, haunching etc including necessary formwork complete all as specified and directed.
M&L for excavation in trenches not exc 1.5 mtr depth for foundation etc n.exc 10sqm on plan in and getting out in hard/dense soil complete all as secified and directed.
M&L for excavation in trenches exc 1.5 m wide and exc 1.5m deep and n.exc 3.0 m deep for foundation beyond the first 1.5 m, etc or for shafts, wells cesspits, manholes, pier holes, etc n exc.10 sq m on plan and getting out in soft/loose soil complete all as specified and directed.
M&L for returning filling in including spreading, levelling, watering and well ramming in layer n.exc 25 cm thick each layer in soil complete all as secified and directed.
M&L for removing excavated soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as secified and directed.
M&L for PCC (1:2:4) Type B0 (using 12.5 mm graded stone aggregate) as levelling course/mass concrete complete all as specified and directed.
M&L for soakage well excavation in any type of soil, foundation of PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) Walls of honey combed brick masonary with top ring of M-25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM (1:4), RCC cover slab in M-25/ SFRC Cover, interconnecting pipes of RCC/DWC complete filled with brick bats, size of well 1.2MX 4.5M Effective Depth complete all as specified and directed.
M&L for Steel tublar swaged poles, complete with cast iron base plate, finials taper plug , bolts, nuts & screws as specified type 410 SP-31 (9.00 mtr long) complete all as specified and directed. Note : Earth work and PCC shall be measured & paid separately under respective items .
M&L for ACSR conductor on existing or new poles complete all as specified and directed.
M&L for GI Pipe light grade complete with fittings laid in floor/ trenches/ wall as cable protection of 80 mm dia complete all as specified and directed.
M&L for cross arms, bracing, supports, clamps and back plated fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as directed inclusive of two coats of aluminium paint over a coat of red oxide primer after dismantling old unserviceable cross arms complete all as specified and directed.
M&L for stay assembly 16/20mm dia rod complete with accessories as shown in electrical plate No 1 (Loop type insulator, stay clamps, excavation and concrete measured separately) complete all as specified and directed.
M&L for loop type insulator, vitreous porcelain,white, brown or green Small size, with overall dimensions 65 x 90mm, clearance of hole 16mm complete all as specified and directed.
M&L for Cable joining kit for LT cable for outdoor termination heat shrink type joint complete with joining material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 sqmm to 70 sqmm complete all as specified and directed.
Supply, laying and testing of cable XLPE insulated, armoured,heavy duty, electric LT UG cable with multi stranded aluminium conductor, 1100 Volts grade, of 70 Sqmm 3.5 Core size complete all as specified and directed. Note : for MT Shed
Supply, laying and testing of cable XLPE insulated, armoured, heavy duty, electric LT UG cable with multi stranded aluminium conductor, 1100 Volts grade of 25 Sqmm 3.5 Core size complete all as specified and directed. Note : for washing Point.
Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type & high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impactand corrosion resistant including thermal management in multiple optics & suitable connection with photoelectric sensor complete with IP 65/66 protection complete all as specified and directed.
S&F for Flood light fitting, complete with switch gear control gear unit lamp and fixing for 100 Watt LED light including necessary clamps, nuts and bolts as per site requirement including fixing on pole/shed with light fittings make a connection with sensor complete all as specified and directed.
S&F for outdoor type Photo Sensitive smart sensor with automatic switch-ON and switch-OFF operation based on ambient lux levels with voltage 220-240V, Rated currrent : 6-10 Amp and Ambient light <5-15 Lux complete & wired with all accessories IP65/IP66 complete all as specified and directed.
S&F for PDC housing integrated LED flame proof highbay with 120 watt capacity luminaire with heat resistant toughened glass with IP 66 protection rating & T 6 temperature class compatible complete including required length of GI wire for hanging of Highbay light complete all as specified and directed.
M&L for sand filling/cushioning in trenches for cable protection including consolidation complete all as specified and directed.
M&L for supplying and laying un-reinforced precast concrete cable cover Class LV, Type I, flat of size 250mm x 150mm x 40mm complete all as specified and directed.
M&L for sub main wiring with two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 6 sqmm size drawn in and including non metallic rigid PVC casing caping/conduit pipe of size as directed by E-in-Charge medium grade (ISI marked with valid CML No) with all fitting & fixing accessories including one run single core PVC insulated unsheathed 6 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed. NOTE: (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc.
M&L for sub main wiring with two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 1.5 sqmm size drawn in and including non metallic rigid PVC casing caping/conduit pipe of size as directed by E-in-Charge medium grade (ISI marked with valid CML No) with all fitting & fixing accessories including one run single core PVC insulated unsheathed 1.5 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed. NOTE: (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc.
S&F in renewal for sheet metal enclosure double door distribution board factory made for MCB DB load link VTPN 4 way suitable for MCCB as incomer, 125 Amp,4 pole & Including MCCB 125 amps 4 pole 16 KA complete (when MCB's are to be used) with suitable size of busbar complete,fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed. Note : 02 Nos for MT Shed and 01 No for Washing point
S&F for pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut for 1100 volts grade complete all as specified and directed.
S&F for Shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts complete all as specified and directed.
M&L for PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete all as specified and directed.
M&L for PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete all as specified and directed.
M&L for PCC (1:2:4) type B-0 (using 12.5 mm graded BT stone aggregate) as in bed block for hold fast or coping including necessary form work complete all as specified and directed.
S&F for MCB DB, sheet metal enclosures double door SPN 8 way with bus bar 240 volts 2 in 1 shutter type (METAL DOOR) type with blanking plates where required and IP 43 degree protection complete all as specified and directed.
S&F for MCB SPN 32 Amps to 40 Amps, 240 volts 'C' series 16 KA, including connection with suitable size copper lugs complete all as specified and directed.
S&F for MCB SP 240 volts, 6 to 32 Amps, 'C' series 10 KA including connection with suitable size copper lugs complete all as specified and directed.
M&L for GI pipe Med grade of 25 mm dia alongwith all fittings and fixtures complete laid in trenches/on wall complete all as specified and directed.
S&F for gun metal gate valves with iron wheel head screwed at both ends for iron pipes of 25 mm dia complete all as specified and directed.
M&L for Cutting of existing DI Pipe for inserting pipes in position for insertion of ferrule including nut bolt clamp, for branch connection of 25 mm dia from existing pipe line.
M&L for Earthing complete with galvanised steel earth plate electrode of size 60cm×60cm×6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.
M/S NIRMAL SINGH DHANJAL
M/S SANJAY AGARWAL
lodhi builders
M/S SANTOSH CONSTRUCTION CO
MAHARAJ KUNWAR SAHAB CONSTRUCTION
mahamaya constructions
THENUA BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .