Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.2 LAccepted-AOC | L1 | Accepted-AOC 1st Lowest | |
| 2 | L2₹39.4 L+₹75,419 (1.95%)Rejected-AOC | L2 | Rejected-AOC 2nd Lowest | |
| 3 | L3₹39.8 L+₹1.1 L (2.86%)Rejected-AOC | L3 | Rejected-AOC 3rd Lowest | |
| 4 | L4₹39.9 L+₹1.2 L (3.18%)Rejected-AOC | L4 | Rejected-AOC 4th Lowest | |
| 5 | L5₹41.1 L+₹2.4 L (6.14%)Rejected-AOC | L5 | Rejected-AOC 5th Lowest |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
29 Mar 2023, 6:00 pmClosed
GE 868 EWS
GE 868 EWS PIN- 913 868 C/o 99 APO
ADDN ALTN TO BLDG NO T 60 IN I ZONE BLDG NO T 1 AT TRANSIT CAMP PROVN OF PCC WITH CHEQUERED TILES PATHWAY FROM TOWER NO 13 TO BT 09 AT TRANSIT CAMP PROVN OF FLOORING FALSE CEILING IN DISPATCH HALL BLDG NO P 217 AT ARO PROVN OF KOTA STONE FLO
2023_MES_584455_1
8523/C/E8
Open Tender
Civil Works
Item Rate
180 days
RANGAPAHAR
Class D , category a(I)
2 documents required · 2 mandatory
₹500
GE 868 EWS
₹76,000
27 Apr 2023
4 Mar 2023
31 Mar 2023
4 Mar 2023
29 Mar 2023
22 Mar 2023
4 Mar 2023 - 11 Mar 2023
Amount
Demolition of plain cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Taking down chowkhat or frames not exc 1.5 Sqm each (without taking off shutter from the frame) complete all as specifed and directed.
Taking down chowkhat or frames exc 1.5 Sqm but not exc 4 Sqm each (without taking off shutter from the frame) complete all as specifed and directed.
Dismantling timber scantlings unframed work 40 sqcm and over in section in any position complete all as specified and directed.
Demolition of reed, lathing single or double, including battens and plaster or chicken wire lathing complete all as specified and directed.
Dismantling Asbestos cement sheet (Corrugated, semi corrugated etc ) in roof covering complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Disamantling wall and ceiling boards (fibre, pulp, insulation, etc.) any thickness including cover fillets complete all as specified and directed.
Dismantling boarding any description fixed in any position with nails complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description etc complete all as specified and as directed.
Surface dressing n exc15 cm deep in soft/loose soil etc complete all as specified and as directed.
M&L broken stone or boulders Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface.
M/L 100mm thick PCC (1:3:6) type C2 using 40mm graded stone aggregate as in floor etc complete all as specified and as directed.
M&L for Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound grade 'A' complete
M & L for PCC 25mm thick type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in floor complete all as specified and directed.
M&L for roughening surface of old concrete floor by picking ,sweeping clean and washing down with water to remove dust etc.
M & L for screed bed or bedding layer of mortar 20mm thick in CM 1:6 for laying floor finishes etc complete all as specified and as directed.
M & L for chequered cement concrete tiles of Size 25mm thick any description jointed and pointed in neat cement slurry in floors with grey cement and pigment
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over 20mm thick screed bed in CM 1:3 complete all as specified and directed.
M & L for 15 mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and directed.
M & L for coloured non skid ceramic tiles 7 to 8 mm thick (square/rectangular) in section exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
All item as per ser No 22 here-in-before on vertical surfaces such as skirting , dado risers to steps over and including 10 mm thick bedding layer in CM 1:4 , set and jointed in neat cement slurry and pointed in white or coloured cement to match all as directed.
M & L for coloured non skid ceramic tiles 7 to 8 mm thick (square/rectangular) in section exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick CM (1:4) backing coat etc complete all as specifed and as directed.
S & F Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed.
S & F Pre-painted galvatume aluminum zinc coating GI based Plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed.
S/F for joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated confirming Fe 410-W (Gde-E- 250) quality- A etc complete all as specified and as directed.
M/L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe 410 -W (Gde-E- 250) quality-A etc complete all as specified and as directed.
S & F of steel work as in tubular trusses including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS – 1161 – 1979 grade St – 240 complete all as specified and directed.
S&F for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe 410 -W (Gde-E- 250) quality-B
S &F for 2nd class hard wood scantling as in purlins rafters & framed work etc clean sawn complete all as specified and directed.
All as per item 32.00 here-in-before but except timber complete all as specified and directed.
S & F for 4 mm thick of size 600x600mm HSPC (high pressure Steam Cured) pre-painted self embossed, textured designer board E-Board Classic to be fixed or laid with GI frame grid/section size 600mm x 600mm with main runner 38x24x0.9 mm thick, cross tee 8.6x24x0.9mm and wall angle 19 x19x0.9mm duly suspended with 2mm dia GI bar hangers 1200mm centre to centre both ways fixed with steel dash fasteners or from purlin from the roof with alignment clip including providing provisions for light fixtures of any size complete all as specified.
M & L 25mm thick second class hard wood boarding , plained one side with butt joints as in eaves boards complete all as specified and directed.
M/L for 75 mm thick PCC 1:3:6 type C2 , using 40 mm graded agg in plinth protection/aprons/path laid to slope of 1:12, finished fair and even without using extra cement with and including all necessary formwork to divide tha area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 10 mm wide joints throughout thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and directed
M&L GI wire netting 0.71 mm dia and 12 mm mesh lathing in to reed in walls incl all laps cutting and waste complete all as specified and directed.
M&L 15mm thick plastering in CM 1:4 on one side of lathing in two separate layers even and smooth without using extra cement complete all as specified and directed.
M&L 10 mm thick plastering in CM 1:6 the other side of lathing finished even and smooth without using extra cement complete all as specified and directed.
S&F anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
S&F for anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section of size 40 x 18 x 1.29mm thick including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified.
S & F for aluminium door shutters, without sash bars, aluminium sections weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing ,handles 2 Nos in each door,hinges, anodised aluminium snap beading screws,mortice lock with keys etc. complete all as specified.
S&F for aluminium (extruded section) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed.
S&F Sheet glass 4.8mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.5sqm in each pane etc complete all as specified and as directed.
S&F Sheet glass 4.8mm thick, ordinary quality and glazing with oil putty in squares exceeding 0.5sqm in each pane etc complete all as specified and as directed.
M&L for fixing 4 mm thick anodised aluminium composite panel fixed in aluminium frame including necessary rubber beading, jointing cleats complete all necessary items to fix with frame and all as specified and directed by Engineer-in Charge.
S & F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples
M&L for 2nd class hard wood plain solid straight chowkats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pined joints complete all as specified and directed.
S & F for Pressed steel frames (1.25 mm thick MS Sheet) of 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and as directed.
M&L for 35 mm thick 2nd class hardwood plain framed pannelled shutter (any number of panels) with panels of timber flat on both sides or of veneered particle board medium density , wood particle board with commercial face veneers , supplied and fitted to chowkats complete all as specified and directed.
M/L 30mm thick 2nd class hard wood Glazed and skelton window and ventilator shutter, open rebated and prepared to receive glass, gauge etc. devided into squares with plain chamfered or rounded, mitred and rebated without sash bars edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I Section-8 clause 8.24(b) complete all as specified.
M & L sheet glass ordinary quality 3mm thick and glazing with oil putty/rebates in squares n.exc. 0.5 sqm each pane complete all as specified and directed.
S&F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples all as directed by Engineer- in -Charge.
S&F in repairs galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples all as directed by Engineer- in -Charge.
S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, overall length of cover plate 140mm etc complete all as specified and as directed.
S & F stainless steel sink, 1mm thick for kitchen with draining board with plug and PVC waste pipe including bedding in cement mortar, fixing brackets overall size 915x460mm, bowl size 410x330x 160mm, as fixed in repairs complete all as specified and directed.(Make: Nirali (Kitchen Queen)/Dimond/Neelkanth/ Prayag/ Blue Star).
S/F second class hardwood clean sawn of 15/20mm thick with butt joints boarding in in shelves; partitions and shelves of built-in cupboards, almirahs, book cases, toilet boxes, racks, pelmets and similarr work with nails in any situation (except flooring and skirting) etc complete all as specified and as directed.
M&L cement concrete type C2 1:3:6 (40 mm graded stone agg) as in surface channels and drains etc complete all as specified and as directed.
M/L PCC (1:2:4) type B1 using 20mm graded stone agg in plinth courses, string courses, parapets, kerbs, bed plates and the like including weathering slightly rounded or chamfered angles and throating, as directed and as in coping including necessary formwork complete all as specified and directed.
Taking down cement plaster on brick walls including raking out joints hacking for key, scrubbing down with water etc complete all as specified and as directed.
Demolition of brick work built in cement mortar incl all quions, arches pillars etc but excl ashalar facing etc complete all as specified and as directed.
M&L brick work with old size sub class B bricks straight or curved on plan exc 6 m mean radius in CM 1:6 etc complete all as specified and as directed.
M&L brick work with old sizesub class B bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 etc complete all as specified and as directed.
M & L rendering 15mm thick in cement mortar 1:4 on fair faces of brick or concrete work even and smooth without using extra cement etc complete all as specified and as directed.
M & L rendering 10mm thick in cement mortar 1:6 on fair faces of brick or concrete work even and smooth without using extra cement etc complete all as specified and as directed.
S & F for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete confirming Fe-290 (Gde E- 165).
S/F Mild steel, plain, black sheet in wall cladding, steel gates and similar work, 1.60mm thick cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required.
Cutting holes in brick walls built in cement mortar or cement lime mortar and stone walls built in lime mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 exc. half brick but not Exc. one brick as required.
M&L for applying two coats of oil bound distemper on new plastered surfaces of walls including preparation of surface and priming with chalk whiting, on plastered surfaces, preparatory to distempering complete all as specified and directed.
M&L for preparation of old decorated surfaces of walls by washing, rubbing down and stopping of distempered surfaces and applying one coat of oil bound distemper of approved shade/tint all as specified.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint of approved shade on walls including priming plastered and other surfaces with alkali resistant priming paint all as specified & directed by Engineer-in-Charge
M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces and applying two coats of cement base paint of approved shade on walls all as specified and directed by Engineer-in-Charge
M&L for preparation of new untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer.
M&L for preparation of old painted surfaces of wood and wood based material of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint all as specified.
M&L for preparation of new steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified & directed
M&L for preparation of old steel surfaces exc 10cm width or girth and applying one coat of synthetic enamel paint all as specified & directed.
S&F grating doom 125mm dia with waste hole of PTMT (Min wt 40 gms) etc complete all as specified and directed.
S & F for towel ring of PTMT fixed with and including Chromium plated Brass Screws and wooden/ plastic cleats ( Minimum weight 90 gms) etc fixed in kitchen.
S&F in repairs for 4 mm thick veneered decorative Plywood (no of ply 05), grade-I (with BWR resin) with decorative face veneers on one face, fixed with screws to timber frame work complete all as specified and directed.
M&L second class hardwood plain fillets exc 13sqcm and not exc. 25sqcm, square or rectangular in section, wrought, secured with nails or brads.
M & L for 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, complete all as specified and directed.
S & F 75mm bore PVC (SWR) bends any radius complete all as specified and directed.
Re-fixing of Wash basins, Vitreous China (flat back or angle back type) any size, including cutting for and pinning in ends of brackets or erecting stand complete all as specified & directed by Engineer-in-Charge .
Taking up or down steel tubing and connections including cleaning for refixing with all fittings for 15 mm bore GI tubing etc complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning for refixing with all fittings for 20 mm bore GI tubing etc complete all as specified and directed.
Refixing of old steel tubing and connections in new or old position with new fittings to floor, wall or ceiling as directed, for 15mm bore GI tubing.
S&F tubes medium grade, galvanised wih all fittings and fixed complete to walls and ceiling or laid on floors etc, 15 mm bore etc complete all as specified and directed.
S&F tubes medium grade, galvanised wih all fittings and fixed complete to walls and ceiling or laid on floors etc, 20 mm bore etc complete all as specified and directed.
S&F in repairs for 15mm dia of pipe bib taps cast copper alloy, fancy type, chromium plated with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule and fixed etc complete all as specified and directed.
S&F in repairs for Draperly rod /Harrison rails of CP of 20mm dia with fixing brackets , stops, rollers and rings etc complete all as specified and directed.
Dismantling timber in fillets rails, posts, rafters, parlins etc under 40 Sqcm in section complete all as specified and as directed.
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete, including fitting & fixtures such as switches with board, ceiling roses, pendents, bell/ buzzer, bell push, lamp holders, regulators, sockets, light fittings etc., removing material from site and making good to the disturbed surfaces of walls, ceiling, floors etc. including making good the disturbed surfaces and paint touch up to match with the existing surface complete all as specified and as directed.
M&L for Point wiring complete with two runs of 1.5 sqmm single core PVC insulated FR-LSH cable 1100 volts grade with multi-stranded copper conductors, drawn through and including PVC double locked Casing & caping including provision of 1.5 sqmm, FR-LSH, PVC insulated copper cable as earth continuity conductor connected to common earth dolly, including PVC rectagular box for mounting switches / sockets / regulators etc. with 3 mm thick plastic laminated sheet cover of suitable size as required at site complete all as specified and as directed.Make:-Richa/KEI/Havells/RR Kabel Make of caping/casing & PVC boxes :- Prestoplast/Finolex/supreme/Richa
One light/Fan/Call bell point controlled by one, one way switch .
One 3 pin socket outlet 5 Amps on the same board with other switches.
One 3 pin socket outlet 5 Amps on the independent board.
All as per item No- 94 here-in-before but with 2.5 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor connected to common earth dolly complete all as specified and as directed.
M&L for Switch piano flush type single pole, one way 5 Amp complete all as specified and as directed. Make:- Havells/Legrand/An
M&L for Socket outlet, 2 in 1, 3 pin 5A flush type complete all as specified and as directed. Make:- Havells/Legrand/Anchor
M&L Switch socket combination 2 in 1, 5A flush type complete all as specified and as directed. Mcomplete all as specified and as directed. ake:- Havells/Legrand/Anchor
M&L Switch socket combination 2 in 1, 5A/16A, 5 in 1 flush type complete all as specified and as directed. Make:- Havells/Legrand/Anchor
M&L for bell push switch 5 amp flush type complete all as specified and as directed. Make: Plaza/SSK/Hager
M&L for Bell, AC, 230 Volts, single pole complete all as specified and as directed.
M&L for ceiling rose 3 terminal PVC/Polycarbonate isolated body complete all as specified and directed. Make:- Havells/Legrand/Achor
M&L for stepped type electronic fan regulator 100/120 Watt socket size flush type on the existing phenolic laminated sheet etc.Make:- Havells/Legrand/Achor
S&F for , IP>= 20, Class-I, LED Light fitting 1 x 20 watt (4 Ft), 240 V, PF-0.9, CRI >= 80, CT>= 6000 K, Wall/ Surface mounted, intergrated type with all accessories internally prewired and incl connecting up with and incl twin/ three core twisted flexible copper conductor cable of suitable size in and incl flexible hose from ceiling rose to fitting complete all as specified and as directed. Make : Crompton/Havells/Bajaj/ Philips
M&L for 10 Watt LED, 2', Wall mounted decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack complete all as specified and as directed. Make : Crompton/Havells/Bajaj/ Philips
M&L in replacement for Decorative wall mounted light fitting made up of polycarbonate including 9 watt LED lamp with B-22 base including taking down old unsv light fitting complete all as specified and as directed. Make: Havells/Bajaj/Surya
Supply , fixing and testing in replacement of LED Bldg Security light fitting of capacity 20 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including 1.2 mtr GI bracket of 25mm bore light grade bent to shape and fixed on wall with metal fastners 2 Nos 10mm dia incl drilling of holes as reqd and connecting up with flexible copper cable of size 0.75 sqmm 3 core from ceiling rose to the light fitting and all as specified and directed by Engr-in-Charge. Make : Crompton/Havells/Bajaj/ Philips
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed.Make : Usha/Bajaj/CG
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete all as specified and as directed.Make : Bajaj/CG/V-Guard
Supply and fixing LED luminaire 600 mm x 600 mm, 40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. Make : Crompton/Havells/Bajaj/ Philips
Supply and fixing for Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20 Amps complete all as specified and directed. Make :Legrand/Havells/Siemens
M&L for MCB Distribution board double door type SPN 8 way, sheet steel, powder painted, with copper bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity including taking down old unsv MCB DBs complete all as specified and as directed. Make :Legrand/Havells/Siemens
M&L for MCB Distribution board double door type SPN 4 way, sheet steel, powder painted, with copper bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity including taking down old unsv MCB DBs complete all as specified and as directed. Make:- Legrand/Havells/Siemens
M&L for MCB SPN 40-63 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB 'C' series incl taking down old unsv MCB complete all as specified and as directed. Make:- Legrand/Havells/Siemens
M&L for MCB SPN 32 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB 'C' series incl taking down old unsv MCB complete all as specified and as directed. Make:- Legrand/Havells/Siemens
M&L for MCB SP 6-32 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB 'C' series incl taking down old unsv MCB complete all as specified and as directed. Make:- Legrand/Havells/Siemens
Taking down existing burnt aluminium/ copper sub main wiring and M&L for sub main wiring with two runs of 4 Sq mm and one run of 4 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn through and including PVC double locked Casing & caping including complete all as specified and as directed. NOTE:- two runs of 4 Sq mm + one run of 4 Sq mm and one run of PVC casing & capping and its accessories of suitable size shall be measured as one unit length Make:-Richa/KEI/Havells/RR Kabel Make of caping/casing & PVC boxes :- Prestoplast/Finolex/supreme/Richa
Taking down Exh/Ceiling fan of any sweep carefully from its installed position, dismantling complete, cleaning all dust, applying grease for bearing, including filling cavaties with filler, after cleaning all dust, reassembling the fan and blades, hanging/ fixing the fan in its original position and testing on completion complete all as specified and as directed.
Taking down burnt unsv LT UG cable of any size and M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 16 sq mm, 2 core complete all as specified and as directed. Make:- Havells/Finolex/Polycab (NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items.)
Taking down burnt unsv LT UG cable of any size and M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 25 sq mm, 2 core complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all complete all as specified and as directed.
Removing of excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all complete all as specified and as directed.
M&L for spread fine river sand in trenches complete all as specified and as directed. NOTE: For measurement purpose, punned down thickness shall only be taken.
M&L for laying brick sub class 'B' old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and as directed
Supply & laying tubes 'light grade' galvanised, with all fittings, fixed complete to walls, poles, ceilings for protection of cables of size 40 mm dia bore including taking out unsv GI tubing complete all as specified and as directed. Make:- Jindal/TATA/Prakash surya
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead strip 32x6mm by means of bolts, nuts check nuts and washers of galvanised iron or steel as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified orindicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1, RCC (1:1.5:3) type A1 precast cover (54cmx54cmx5cm) duly reinforced with including 8 mm dia TMT bar @ 150mm c/c both ways, one lifting handle made of 8mm dia TMT bar, embeded in precast cover slab, funnel, 20mm dia GI medium grade watering pipe, 15mm dia GI light grade earth lead protection pipe, chorcoal and common salt in alternatee layer complete all as specified and directed by Engr-in-Charge.
M/S VIKASH TRADERS
SHRI HRIDAY NARAIN GIRI
M/S SANGITA TRADERS
PERFECT BUILDERS AND SUPPLIERS
MS SADHNA RAHUL
Shri B K Ukil
M/S Lucky Builders
SHRI BANARSI PRASAD
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .