Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.8 LAccepted-AOC LAMBA LINE PB NO 414 JUNGLIGHAT PO PORT BLAIR A N 744103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L1 | Accepted-AOC L1 | |
| 2 | L2₹52.3 L+₹1.7 L (3.45%)Rejected-Finance 94A APR COLONY BILHARI JABALPUR MP | JABALPUR | MADHYA PRADESH | 482020 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹52.7 L+₹2.2 L (4.32%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹53.2 L+₹2.6 L (5.21%)Rejected-Finance PB NO 809 ABERDEEN BAZAR PO ATLANTA POINT NEAR POLICE WIRELESS PORT BLAIR 744104 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744104 | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹54.0 L+₹3.4 L (6.79%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
24 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Minniebay
GE Minniebay Junglighat Post Minniebay Port Blair 744103
REPAIR, MAINT AND RENEWAL OF GEYSERS,FANS, LIFTS AND ALLIED WORKS AT MINNIE BAY AND REPAIR MAINT OF INTERNAL ELECTRICAL SUPPLY ALONG WITH ITS ELECTRICAL FIXTURES AT HQ 34WEU UNDER AGE EM-I MINNIE BAY AT GE MINNIE BAY PORT BLAIR
2023_MES_599034_1
8260/E8
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
Minniebay Port Blair
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE Minniebay
₹98,000
Yes
1 Jul 2023
27 May 2023
26 Jun 2023
28 May 2023
24 Jun 2023
11 Jun 2023
Amount
M&L for taking down carefully existing aluminium point wiring (light, fan, socket or power) complete fittings fixture such as switches Ceiling roses, pendents,regulators, sockets etc to be measured separately)unscrewing from Board/outlet boxes, fittings & fixtures such as switches, sockets, ceiling rose lamp holder tube/ceiling fitting, bulk head fittings, tube lights & regulator etc and making good disturbed surfaces of walls, floors etc. complete all as specified and as directed by Engineer-in-Charge.
M&L for taking down carefully existing old DBs and making good disturbed surfaces of walls to match the existing surfaces complete all as specified and as directed by Engineer-in-Charge.
M&L for taking down unserviceable submain wiring alongwith batten/PVC/steel conduits etc and making good disturbed surfaces of walls/ floors to match the existing surfaces complete all as specified and as directed by Engineer-in-Charge.
M&L for point wiring with two runs of single core PVC insulated unsheathed 1100 volts grade multistranded copper conductor of size 1.5 Sqmm nominal area (FRLSH) drawn through & including rigid non metallic PVC conduit medium grade of size not less than 20mm dia for concealed wiring with PVC conduit accessories or PVC casing capping of suitable size but not less than 20 mm in width for surface wiring with PVC casing capping fitting accessories along with 3mm laminated sheet and PVC terminal box including continuous earth wire of PVC insulated unsheathed 1100 volts grade multistranded copper conductor of size 1.5 Sqmm nominal area (FRLSH) connecting to common earth dolly using color code system complete all as specified and as directed by Engineer-in-Charge.
One light point controlled by one way switch.
One 3 pin socket outlet, 5 Amps, on the same board with other switches.
One 3 pin socket outlet 5 Amps, independent.
All as per item No 04 above but cable with 2.5 sqmm size for socket outlet 15 amps on independent board.
S&F wiring for submain wiring with two run of single core PVC insulated unsheathed, 1100 volts grade, multistranded copper conductor cable of size 6 Sqmm nominal area (FRLSH) drawn through in and including rigid non metallic PVC conduit ISI marked medium grade of size not less than 25mm dia with conduit accessories or PVC casing capping of size not less than 25mm in width with PVC casing capping fitting accessories laid on wall/ceiling and one run of 6 Sqmm PVC insulated copper conductor(FRLSH) for earth continuity wire complete all as specified and as directed by Engineer-in-Charge. Note : Two runs of single core cable with one run of earth continuity conductor and one run of PVC conduit/PVC casing capping will be measured as one unit length.
S&F submain wiring with two run of single core PVC insulated unsheathed, 1100 volts grade, multistranded copper conductor cable of size 2.5 Sqmm nominal area (FRLSH) drawn through in and including rigid non metallic PVC conduit medium grade of size not less than 20mm dia with conduit accessories or PVC casing capping of size not less than 20mm in width with PVC casing capping fitting accessories laid on wall/ceiling and one run of 2.5 Sqmm PVC insulated copper conductor(FRLSH) for earth continuity wire complete all as specified and as directed by Engineer-in-Charge. Note : Two run of single core cable with one run of earth continuity conductor and one run of PVC conduit/PVC casing capping will be measured as one unit length.
S&F submain wiring with two run of single core PVC insulated unsheathed, 1100 volts grade, multistranded copper conductor cable of size 1.5 Sqmm nominal area (FRLSH) drawn through in and including rigid non metallic PVC conduit medium grade of size not less than 20mm dia with conduit accessories or PVC casing capping of size not less than 20mm in width with PVC casing capping fitting accessories laid on wall/ceiling and one run of 1.5 Sqmm PVC insulated copper conductor(FRLSH) for earth continuity wire complete all as specified and as directed by Engineer-in-Charge. Note : Two run of single core cable with one run of earth continuity conductor and one run of PVC conduit/PVC casing capping will be measured as one unit length.
S&F switch piano, flush type, single pole, one way 5 Amp complete all as specified and as directed by Engineer-in-Charge.
S&F switch piano, flush type, single pole, one way 15 Amp complete all as specified and as directed by Engineer-in-Charge.
S&F switch socket combination 3 pin, 6 and 15/16 Amp flush type complete all as specified and as directed by Engineer-in-Charge.
S&F switch socket combination 5/6 Amp flush type complete all as specified and as directed by Engineer-in-Charge.
S&F ceiling Rose, 3 terminal polycarbonate isolated body complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair switch piano, flush type, single pole, one way 5 Amp complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair switch piano, flush type, single pole, one way 15 Amp complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flush type complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair switch socket combination 2 in 1, 6 Amp flush type complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair ceiling Rose, 3 terminal polycarbonate isolated body complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair PVC Surface box suitable for switch socket combination 6 and 16 Amp complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair LED lights fitting 1x 20W, 4 feet 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED luminaire 600 mm x 600 mm 40 watt, 220V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair LED Foco bulb 9 watt, B22 complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair modular switch one way, 6 Amps, 1 module complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair modular switch one way, 16 Amps, 1 module complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair modular socket, 2/3 pin, 6 amps, 2 module complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair modular socket, 2/3 pin, 6/16 amps, 2 module complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair modular metal/PVC flush box 3 module complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair modular metal/PVC flush box 6 module complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair modular white cover plate with frame 3 module complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair modular white cover plate with frame 6 module complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair Power unit modules 25A, 240V, 50HZ consists of 2 module surface mounting plastic box - 2 No, 2 module cover plate & frame - 2 No, 25Amps Motor Starter - 1 No , 25Amps socket - 01 No and 25 Amps Plug Top - 1 No complete all as specified and as directed by Engineer-in-Charge.
S & F wall mounted fan 400 mm sweep complete fixed on wall with nut bolts including provision of 3 core flexible PVC cable with stranded copper conductor of size 1.5 Sqmm from ceiling rose to connector of air circulator fan all as specified and directed by Engineer-in-Charge. Note : Old unserviceable fan shall be deposited in AGE EM store yard and necessary receipt voucher shall be attached with bill for payment purpose.
S&F as in repair of MCCB DB VTPN 4 way IP-43 made of sheet steel phos phatised, powder painted with bus bar, neutral link, earth bar and Din rail ,415 Volts with double door with MCCB incomer and MCB outgoing and fixing of cable with suitable size of lugs complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair MCB DB SPN 8 way, double door, sheet metal enclosure, 240V, 100 amps rated busbar including fixing of cable with appropriate size of lugs complete all as specified and as directed. Note : Cost for concealed the DBs on wall including making good disturbed surfaces with existing colour shall be deemed to be included in the quoted rate.
S&F as in repair MCCB 4 Pole, 415V, Adjustable type, 100 to 125 Amps with breaking capacity 16 KA complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair MCB SPN 40 to 63 Amps ,10 KA, C Curve, 230 Volt, 50 HZ complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair MCB SP 6-32 Amps ,10 KA, C Curve, 230 Volts ,50 HZ complete all as specified and as directed by Engineer-in-Charge.
M&L for earthing complete with Galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below GL) with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanized earth strip 32x6 mm size connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 40 mm dia GI pipe medium grade for protection of GI earth lead and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type CI chamber. MS funnel, wire gauge. 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos. 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I including replacement of old unsv earthig complete all as specified and as directed by Engineer-in-Charge. Note: (i) Cost of GI earth strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returning & filling, PCC chamber pit, RCC cover & test point.(iii) All accessories required for galvanized steel plate electrode required, as specified and as directed.(iv) If the desired earth resistance is not achieved during testing as per IS , the complete earthing shall be replaced / repaired by the contractor at his own cost and no extra claim shall be admissible. (v) Earth test report shall be submitted to Accepting Officer for the payment of RAR / FB
S&F in replacement of on load change over switch 415 V, 4pole,630amps as per existing make and model suitable or equivalent make as per list of make at PS complete all as specified and directed by Engineer-in-Charge.
S&F as in repair MCCB 400 Amps, 4 pole, 415 volt, breaking capacity 25 KA complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair MCCB 250 Amps, 4 pole, 415 volt, breaking capacity 25 KA complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair MCCB 4 Pole 125 A, 16 KA breaking capacity with suitable size of lugs including taking out old unserviceable MCCB complete all as specified and as directed by Engineer-in-Charge. Make: L & T or equivalent
Supply and fix in repair MCCB 4 Pole 100/63 A with suitable size of lugs including taking out old unserviceable MCCB complete all as specified and as directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3½ core including taking down unserviceable cable complete all as specified and as directed by Engineer-in-Charge. Note : Necessary earthwork shall be measured and paid separately.
Supply & Laying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 300 mm and inner dia 260 mm polythylene including coupler & Bend with smoooth inernal and profiled external surface for non pressue under ground cable including taking down unserviceable DWC pipe complete all as specified and as directed by Engineer-in-Charge.
M&L for Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of pipe line and getting out in hard/dense soil complete all as specified and as directed by Engineer-in-Charge.
M&L for Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm in hard/dense soil complete all as specified and as directed by Engineer-in-Charge.
M&L for Removing excavated material in soils n exc.50m and deposting where directed at a level n exc.1.5m above the starting point all as directed by Engineer-in-Charge.
S&F for cable jointing kit for 1100Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 185 to 240 Sqmm 3.5 Core as in repairs complete all as specified and as directed by Engineer-in-Charge.
M&L for taking down existing street light fitting of any type from the street light poles of any height complete all as specified and as directed by Engineer-in-Charge.
Dismantling the existing old rusted /unserviciable Steel / RCC poles of any type including all fitting fixture complete all as specified and as directed by Engineer-in-Charge.
S&F of GI tubular swaged poles complete with GI base plate finial taper plug, bolts, nuts and screws, with two holes for drawing conductor between pole box to street light fitting all as specified type 410 SP-31 of height 9m including necessary Earth work,PCC foundation copping etc and refixing of all existing fitting fixture exist in old electric pole complete all as specified and as directed by Engineer-in-Charge.
M&L for painting to Steel tublar / RCC poles 9 m long with one coat of Synthetic enamel paint black/yellow combination Zebra marking up to 1 m from ground level / copping remaining Job portion painting with one coat of aluminium paint including preparation of old painted surfaces and painting the pole terminal etc.complete all as specified and as directed by Engineer-in-Charge.
Supply and laying as in repair 2.5 Sq.mm x 3 run PVC unsheathed multi strandard copper conductor PVC insulated 1100 volt FRLSH grade cable drawn through CPVC Pipe not less than 20 mm dia for connecting the street light fittings including aluminium clamp complete all as specified and as directed by Engineer-in-Charge.
Supply and fix GI bracket for street lights made out of medium grade GI pipe 40mm dia, 1.2 mtr long bend to shape as directed, fixed on poles with two Nos GI clamp of size 40 x 6mm flat iron suitable for steel tubular pole including suitable GI nuts and bolts washers complete all as specified and as directed by Engineer-in-Charge.
S&F energy efficient street light luminaire LED type 90 watts, IP66, 230volts, 50 Hz, in Deepdrawn aluminium housing and cast aluminium pipe mounting attachment including suitable heavy duty electronic driver also driver should withstand 265 volts and complete accessories, pre-wired and connection complete with suitable size of stranded copper flexible conductor complete all as specified and as directed by Engineer-in-Charge.
S&F energy efficient street light luminaire LED type 72 watts, IP66, 230volts, 50 Hz, in Deepdrawn aluminium housing and cast aluminium pipe mounting attachment including suitable heavy duty electronic driver also driver should withstand 265 volts and complete accessories, pre-wired and connection complete with suitable size of stranded copper flexible conductor complete all as specified and as directed by Engineer-in-Charge.
S&F LED Bollard 10 W light made in cast aluminium spigot housing withdecorativecleare opal arcylicdiffuser and IP 65 protection complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED security light fitting 24 watt 230V AC outdoor type pressure die cast housing with epoxy powder coated, poly carbonate cover with individual LED lenses with IP 65 protection complete all specified and as directed by Engineer-in-Charge.
Supply and fixing LED flood light 100 watt 230V AC outdoor type pressure die cast housing with epoxy powder coated, poly carbonate cover with individual LED lenses with IP 65 protection complete all specified and as directed by Engineer-in-Charge.
Supply & fixing IP 66 thermoplastic-polycarbonate cable junction box of size 155X210X92 with terminal suitable for 10 to 16 Sqmm ,which is totally shock proof, water proof, halogen free, silica and having internally embedded gasket technology fixing on pole / surface / frame with the help of required size / self drill screw & 1 No of MCB SP 6 to 32 amps and four way 32 Amp Connector complete all as specified and as directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3½ core complete all as specified and as directed by Engineer-in-Charge.
Supply & Laying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polythylene including coupler & Bend with smoooth inernal and profiled external surface for non pressue under ground cable complete all as specified and as directed by Engineer-in-Charge.
M&L for servicing of split type air conditioner 1.5/2 ton capacity by removing airfilter/bacteria filter and washing by soap water, cleaning of cooling fins and outdoor unit by using blower for making dust free and applying lubricants to all the moveable parts and replacement of worn out bolts & nuts and remote batteries etc at site and reassembling & fixing back their original position including testing complete all as specified and as directed by Engineer-in-Charge.
M&L leak testing for split type air conditioner 1.5/2 TR by removing refrigerant from the unit, pressurize the nitrogen gas of suitable pressure to carryout an effective leak test and the found leakage to be arrested by using refrigerant leak sealant/soldering complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of running capacitor 36 MFD of suitable model for Split AC 1.5/2 TR complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of running capacitor 45 MFD of suitable model for Split AC 1.5/2 TR complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of running capacitor 2.5 MFD of suitable model for Split AC 1.5 / 2.0 TR complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of running capacitor 4.0 MFD of suitable model for Split AC 1.5 / 2.0 TR complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of outdoor condenser coil made up of copper tubes suitable for 1.5 TR air conditioner complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of outdoor condenser coil made up of copper tubes suitable for 2.0 TR air conditioner complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of air conditioner mounting bracket heavy duty GI steel/MS, Powder coating finish inclusive of nuts and bolts for mounting the bracket on existing place complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of PC board complete suitable for existing model of split AC 1.5 TR capacity complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of PC board complete suitable for existing model of split AC 2.0 TR capacity complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of PC board complete suitable for indoor unit of inverter type split type AC 1.5 TR capacity of existing place complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of PC board complete suitable for indoor unit of inverter type split type AC 2.0 TR capacity of existing place complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of PC board complete suitable for outdoor unit of inverter type split type AC 1.5 TR capacity of existing place complete all as specified and as directed by Engineer-in-Charge by Engineer-in-Charge.
Supply and fixing as in repair of PC board complete suitable for outdoor unit of inverter type split type AC 2.0 TR capacity of existing place complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of single shaft outdoor unit blower fan motor suitable for any model of split type AC 1.5 TR capacity, single/ double speed, single phase, 230Volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of single shaft outdoor unit blower fan motor suitable for any model of split type AC 2 TR capacity, single/ double speed, single phase, 230Volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of indoor swing motor suitable for any make/model of split type AC 1.5 TR, 12V DC complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of indoor swing motor suitable for any make/model of split type AC 2.0 TR, 12V DC complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of single shaft indoor unit blower fan motor suitable for any model of split type AC 1.5 TR capacity, single/ double speed, single phase, 230Volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of single shaft indoor unit blower fan motor suitable for any model of split type AC 2.0 TR capacity, single/ double speed, single phase, 230Volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of sealed unit compressor (OEM approved) for Split type AC 1.5 TR of any make/model, copper tube connection at suction & discharge side with the help of copper brazing, connect the all electrical connection and charging the system with required gas and necessary testing and commissioning complete all as specified and as directed by Engineer-in-Charge. Note : Refrigerant gas shall be measured and paid separately.Any defects observed shall be replaced suitably by contractor on free of cost.
Supply and fixing as in repair of sealed unit compressor (OEM approved) for Split type AC 2.0 TR of any make/model, copper tube connection at suction & discharge side with the help of copper brazing, connect the all electrical connection and charging the system with required gas and necessary testing and commissioning complete all as specified and as directed by Engineer-in-Charge. Note : Refrigerant gas shall be measured and paid separately.
Supply and fixing as in repair of sheet metal enclosure with socket plug top & MCB single pole and neutral enclosure with a two pin and earth plug & socket complete with one single pole MCB 06-32 Amps complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of 1100 volts PVC insulated, multistranded copper conductor FRLSH grade of size 2.5 sqmm, 3 core complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of Copper tubing of size 5/8" flare size conforming to relevant IS complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of Copper tubing of size 1/2" flare size conforming to relevant IS complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of Copper tubing of size 1/4" flare size conforming to relevant IS complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of Copper tubing of size 3/8" flare size conforming to relevant IS complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of nitrile insulation of copper tubing for split unit of any capacity & any size from indoor to out door unit complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of Voltage Stablizer of 5KVA capacity for automatic operation single phase naturally air cooled, indoor type, designed for input variation between 170V to 250V with output voltage stablizeed at 230V with accuracy of 2.5% as per existing make and refixing the all electrical connection making suitable fixing arrangement as required at existing place, necessary testing and commissioning complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of Voltage Stablizer of 4 KVA capacity for automatic operation single phase naturally air cooled, indoor type, designed for input variation between 170V to 250V with output voltage stablizeed at 230V with accuracy of 2.5% as per existing make and refixing the all electrical connection making suitable fixing arrangement as required at existing place, necessary testing and commissioning complete all as specified and as directed by Engineer-in-Charge.
Supply only Refrigerant gas R-32 in manufacturer's sealed cylinder complete all as specified and as directed by Engineer-in-Charge. (i) Empty cylinder shall be returned to the contractor. (ii) Payment shall be made for net weight of gas.
Taking down carefully existing aluminium point wiring (light, fan , socket or power) complete fittings fixture such as switches Ceiling roses, pendents,regulators, sockets etc to be measured separately)unscrewing from Board/outlet boxes, fittings & fixtures such as switches, sockets, ceiling rose lamp holder tube/ceiling fitting, bulk head fittings, tube lights & regulator etc and making good disturbed surfaces of walls, floors etc. complete all as specified and as directed by Engineer-in-Charge.
M&L for point wiring with two run of single core PVC insulated unsheathed 1100 volts grade multistranded copper conductor of size 1.5 Sqmm nominal area (FRLSH) drawn through & including rigid non metallic PVC conduit ISI marked medium grade of size not less than 20mm dia for concealed wiring with PVC conduit accessories or PVC casing capping of suitable size but not less than 20 mm in width for surface wiring with PVC casing capping fitting accessories including continuous earth wire of PVC insulated unsheathed 1100 volts grade multistranded copper conductor of size 1.5 Sqmm nominal area (FRLSH) connecting to common earth dolly using color code system complete all as specified and as directed by Engineer-in-Charge.
One fan point controlled by one switch.
S&F as in repair stepped type electronic fan regulator (Socket size), flush type complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair stepped type electronic fan regulator (Switch size) flush type complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair modular fan step regulator, 120W-2 module complete all as specified and as directed by Engineer-in-Charge.
M&L for taking down ceiling fan of any sweep, sealing cable end, dismantling blades, painting of ceiling fans complete with synthetic enamel paint white by spraying including filling cavities with filler, one coat after cleaning all dust etc., including fixing at the same position and provision of cable from ceiling rose or connector to fan complete all as directed by Engineer-in-Charge.
Taking down ceiling mounted of size 400/450 mm of any type, any make , by opening of body carefully checking for replacement of unserviceable spares, including replacement of spares by new one, re-assembling of all components in original position, cleaning, oiling, greasing, testing and fixed in original position complete all as directed by Engineer-in-Charge. Note: New spare parts required for renewal shall be measured and paid separately as 'Supply only'.
Supply only following spares of ceiling fan complete all as specified and as directed by Engineer-in-Charge.
Ball Bearing 6201
Ball Bearing 6202
MS Shaft
Canopy (Top & Bottom)
Blade of size 1200 mm
Bobin Set
Capacitor 2.5 Mfd
Supply & Fix 1400 mm sweep ceiling fan, BLDC, 240 volt , Opal . White/brown including rod minimum length 1.5 m and bush , nut bolts , capacitors including drilling on roof and fixed 1 to 1.5 feet rod and connecting bolts etc complete all as specified and as directed by Engr-in-Charge Make : Havells model No Effciencia Neo or equivilant makes mentioned in list of makes Note : Old unserviceable fan shall be deposited in AGE EM store yard and necessary receipt voucher shall be attached with bill for payment purpose.
M&L for taking down exhaust fan of any size/make for repairing and fixing of exhaust fan at same place after repairing including provision of cable from ceiling rose or connector to fan & nut and bolts complete all as specified and as directed by Engineer-in-Charge. Notes : Spares shall be measured and paid under relevant item as "Supply Only"
Supply only the following spares of exhaust fan any size/make complete all as specified and as directed by Engineer-in-Charge.
copper bush suitable for exhaust fan 250/300 mm
MS Shaft suitable for 300/450 mm sweep exhaust fan
Exhaust fan blade of size 300mm
S&F as in repair exaust fan louver aluminium suitable for hole size 300mm fixing up to 3rd floor including scaffolding and safety arrangement complete all as specified and as directed by Engineer-in-Charge. Note : The cost for scaffolding and safety arrangement shall be deemed to be included in the quoted rate.
Supply & Fix exhaust fan PVC body, 200mm sweep 240 volt , 1300 rpm, Opal . White/brown including making hole suitable size for fixing and making good to disturbed surface, fixing flap cover including fixing accessories complete all as specified and as directed by Engr-in-Charge. Note : Old unserviceable fan shall be deposited in AGE EM store yard and necessary receipt voucher shall be attached with bill for payment purpose.
Supply & Fix exhaust fan PVC body, 250mm sweep 240 volt , 1300 rpm, Opal . White/brown including making hole suitable size for fixing and making good to disturbed surface, fixing flap cover including fixing accessories complete all as specified and as directed by Engr-in-Charge. Note : Old unserviceable fan shall be deposited in AGE EM store yard and necessary receipt voucher shall be attached with bill for payment purpose.
Supply & Fix exhaust fan metal body, 450mm sweep 240 volt , 1400rpm,Opal . Brown / Black including making hole suitable size for fixing and making good to disturbed surface, fixing flap cover including fixing accessories complete all as specified and as directed by Engr-in-Charge. Note : Old unserviceable fan shall be deposited in AGE EM store yard and necessary receipt voucher shall be attached with bill for payment purpose.
S&F as in repair 1100 volts PVC insulated, sheathed multistranded copper conductor FRLSH grade cable of size 1.5 sqmm, 3 core complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair heavy duty air circulator of sweep 600 mm, 230V, metal body complete all as specified and as directed by Engineer-in-Charge. Note : Old unserviceable fan shall be deposited in AGE EM store yard and necessary receipt voucher shall be attached with bill for payment purpose.
Dismantling to geyser of capacity 25 ltr of any make, taking out inner tank, descaling the inner surface by scrapping carrying out soldering/ brazing/gas welding to prevent the leakage, filling of glass wool & assembling the same after repair including replacement of required number of stainless steel screws, nuts & bolts for fixing of siphon assembly etc complete all as specified and directed by Engineer-in-charge. Note : Glass wool shall be measured & paid under this quoted item. Spares shall be measured and paid separately under relevant item as "Supply only"
Supply only the following spares of geyser any capacity/make complete all as specified and as directed by Engineer-in-Charge.
Thermostat suitable for geyser 25 ltrs capacity
Heating element 2 KW suitable for existing make/model of geyser
Indicating lamp (Red/Green)
Stainless steel geyser connection pipe for hot/cold water 450mm long with brass end nuts suitable for 15mm dia GI tubing complete
Geyser pressure safety relief valve
Taking down carefully old unserviceable geyser 50 Ltr capacity with necessary fitting and making good to damaged surface of wall to match existing finish , depositing to MES store and Supply and fix energy efficient new 50 liters capacity electrical geyser white/half white, copper container inner tank with fibre reinforced body (FRB) puff insulation for both inner tank & for hot outlet copper connection pipe with all in built in safety accessories like thermostat/automatic thermal cut out with ON /OFF /CUT out indicators all pre-wired and additional safety accessories like pressure release valve/pressure reducing valve, non return valve, rate shall be including for new PVC heavy duty pipe with brass ferrule fitting for HOT and COLD water connections fixed in same or new location as ordered/required as per manufacturers instruction with suitable size nuts & bolts, making necessary connection & testing on completion complete all as directed by Engineer-in-Charge.
S&F as in repair PVC insulated, sheathed multistranded copper conductor cable of size 2.5 sqmm, 3 core complete all as specified and as directed by Engineer-in-Charge.
M&L for taking down wall fan of any size/make for repairing and fixing of wall fan at same place after repairing complete all as specified and as directed by Engineer-in-Charge. Notes : Spares shall be measured and paid under relevant item as "Supply Only"
Supply only the following spares of wall fan any size/make complete all as specified and as directed by Engineer-in-Charge.
Fan wall mount bracket
Wall fan capacitor 1.5 Mfd
Fan guard ring
Wall fan blade of size 400/450 mm
S & F in repair wall mounted fan 400 mm sweep complete fixed on wall with nut bolts including provision of 3 core flexible PVC cable with stranded copper conductor of size 1.5 Sqmm from ceiling rose to connector of air circulator fan all as specified and directed by Engineer-in-Charge. Note : Old unserviceable fan shall be deposited in AGE EM store yard and necessary receipt voucher shall be attached with bill for payment purpose.
S & F in repair wall mounted fan 450 mm sweep complete fixed on wall with nut bolts including provision of 3 core flexible PVC cable with stranded copper conductor of size 1.5 Sqmm from ceiling rose to connector of air circulator fan all as specified and directed by Engineer-in-Charge. Note : Old unserviceable fan shall be deposited in AGE EM store yard and necessary receipt voucher shall be attached with bill for payment purpose.
S&F as in repair Plug top 16 Amp 3 pin complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair metal clad plug 20 Amp 3 pin complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair Plug top 5/6 Amp 3 pin complete all as specified and as directed by Engineer-in-Charge.
Comprehensive maintenance and repair including renewal/ replacement of minor/ major defective parts of electrically operated lift of capacity stretcher cum 20 passenger (1360 Kgs), fully down collective with microprocessor based control panel gear lift, automatic operated sliding doors serving ground plus upper three floors (G+3), Make "JOHNSON" installed at INHS Dhanvantari including carrying out the monthly check and routine periodical service as mentioned in PS of fully automatic electric lift without attendant with power operated door duplex collective control system MRL, Gear with replacement of unserviceable parts such as bearing, bushes, all type of shoes, headers, hangers, door cards, door lock, control cards, control connectors/ links, hall push buttons, hall push button covers, rewinding of motors, welding of crack/ broken MS parts, repairs to door,safety edge working at any principle and any type of sensor or mechanical safety lock, magnetic lock or contact, cop buttons, car position indicator, door cill, car door cill, necessary wiring and cable, infrared sensor and all major/minor parts as per requirement for safe operation of lift, lift cabin fan, cabin light, ARD Batteries wincluding tube rod & tube light fitting etc.complete to ensure safety and smooth operation of lift. - 02 Nos of Lifts (Platinum service provided by the OEM) complete all as specified and as directed by Engineer-in-Charge.
Comprehensive maintenance and repair including renewal/ replacement of minor/ major defective parts of electrically operated lift of capacity Goods cum 20 passenger (1360 Kgs), fully down collective with microprocessor based control panel gearless lift, automatic operated sliding doors serving ground plus upper three floors (G+2), Make "JOHNSON" installed at INHS Dhanvantari including carrying out the monthly check and routine periodical service as mentioned in PS of fully automatic electric lift without attendant with power operated door duplex collective control system MRL, Gearless with replacement of unserviceable parts such as bearing, bushes, all type of shoes, headers, hangers, door cards, door lock, control cards, control connectors/ links, hall push buttons, hall push button covers, rewinding of motors, welding of crack/ broken MS parts, repairs to door,safety edge working at any principle and any type of sensor or mechanical safety lock, magnetic lock or contact, cop buttons, car position indicator, door cill, car door cill, necessary wiring and cable, infrared sensor and all major/minor parts as per requirement for safe operation of lift, lift cabin fan, cabin light, ARD Batteries including tube rod & tube light fitting etc.complete to ensure safety and smooth operation of lift. - 01 No of Lift (Platinum service provided by the OEM) complete all as specified and as directed by Engineer-in-Charge.
Notes for SI Item Nos 127 to 128 (i) The comprehensive maintenance (Platinum Agreement) shall be done through respective OEM of existing lifts i.e of M/s Johnson Lifts Pvt Ltd. (ii) The contractor will have to submit MOU on stamp paper of Rs 100/- duly notarized, as per specified perform given on Particular Specification from respective OEM of existing lifts i.e of M/s Johnson Lifts Pvt Ltd. within Twenty Eight days from date of receipt of acceptance of tender, failing which the contract will be liable to be cancelled and further action to be taken as per policy in vogue of the contractors default. (iii) Contractor will conclude AMC with OEM and copy of the agreement along with Tax invoice will be submitted to Engineer-in-charge and GE before commencement of AMC. No payment will be made to contractor without submission of valid AMC agreement. (iv) The above maintenance include complete maintenance of existing lift by regularly and systematically examining adjusting fabricating as and attending complaints within respective time frame as catered in Particular specification for smooth and efficient functioning of the equipment/lift. (v) The Contract includes for repair, replacement of spare parts etc as mentioned in Sch ‘A’ (BOQ).
Notes for SI Item Nos 127 to 128 Contd..... (vi) Contractor will prominently display his contact/ mobile number and OEM contact number inside and outside the lift on each lift for call in emergency. (vii) All existing earthing of the lifts shall be maintained and made fully functional by the contractor to the entire satisfaction of the Engr-in-charge / GE. (viii) Contractor shall submit Safety security certificate of lifts from OEM in every month as per performa given in particular specification and also contractor to ensure serviceability of lights and fans in lifts and machine room in every month in wiring and shall be submitted along with running account receipts and final bill failing which payment shall not be processed. (xi) The OEM will also detail one technician staff to inspect the lift every week regarding functioning of lifts or any other issues arising in the lift. The details of technician shall be forwarded for approval before commencement of work. The problem noticed if any to be informed immediately to JE E/M / Engr-in-charge. Incase no technician detailed Rs 500/- per week per lift will be deducted from contractors dues. Technician should always carry service tools during site visit in every week. (x) Monthly maintenance check will be carried out by OEM as per monthly maintenance check list mentioned in particular specification.
S & F as in repair of the following items for the service lift prior to AMC for lift No. L-H 5936 complete all as specified and as directed by Engineer in Charge: (a) Charger Unit - 01 No (b) Charger battery - 01 No (c) Three way intercom (press & speak) speaker - 01 No (d) Three way intercom (press & speak) handset - 01 No (e) Metal roller 'V' Assy - 08 Nos (f) OSG Assy (1.00MPS/ with limit switch / machine room/ OSG wheel dia 300 mm) - 01 No (g) Bearing oil - 03 Ltrs (h) Door belt (big) - 01 No (j) Door belt (small) - 01 No (k) Gong bell PCB Assy incl LED back light with coil (white), voice board ver V3 - 12-24 V DC - 04 Nos (l) OSG tension WT. wheel - 01 No
S & F as in repair of the following items for the service lift prior to AMC for lift No. L-H 5937 complete all as specified and as directed by Engineer in Charge: (a) Orange square dot matrix display with gong driver SG 1005 - 01 No (b) Charger battery - 01 No (c) Bearing Oil - 03 Ltrs (d) Three way intercom (press & speak) handset - 01 No (g) Door belt (big) - 01 No (j) Gong bell PCB Assy incl LED back light with coil (white), voice board ver V3 - 12-24 V DC - 02 Nos.
S & F as in repair of the following items for the service lift prior to AMC for lift No. L-H 5938 complete all as specified and as directed by Engineer in Charge: (a) Charger battery - 01 No (b) Metal roller 'V' Assy - 16 Nos (c) Bearing oil - 3 Ltrs (g) Door belt (big) - 01 No (h) Door belt (small) - 01 No (j) Gong bell PCB Assy incl LED back light with coil (white), voice board ver V3 (12-24)V - 03 Nos
Taking down existing old unserviceable Lead acid battery 12V 20 AH maintenance free and replacing the same with new one as per OEM recommendation for automatic rescue device (ARD) for 20 Passanger lift installed complete all as specified and as directed by Engineer-in-charge.
Taking down existing old unserviceable hooter assembly and replace the same with new one as per OEM recommendation along with necessary cables suitable for 20 passanger lift complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of old steel surfaces and applying one coat of synthetic enamel paint over the surfaces of electronic lift machineries such as motor, gear box, control panel etc including writing of MES number complete all as specified and as directed by Engineer-in-charge.
Ravi Enterprises
SK CONSTRUCTION
Chandra Construction Enterprises
DHAKSHNA MOORTHY AND SON
M/s Karbhagam Sales Agency
SKY GROUP
MGP Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .