Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 CrAdmitted-Finance 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | ₹2.6 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.8 CrAdmitted-Finance 4TH FLOOR VOLTAS HOUSE A BLOCK DR BABASAHEB AMBEDKAR ROAD CHINCHPOKLI MUMBAI MAHARASHTRA 400033 | MUMBAI | MAHARASHTRA | 400033 | ₹2.8 Cr | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technically Not Qualified |
| Sl No | Description | Qty | Unit | Blue Star Limited L1 | VOLTAS LIMITED L2 |
|---|---|---|---|---|---|
| 1.00 | Client workstation: SITC of BMS Computer System: i7 Processor or Equivalent Server PC, Intel(R) Xeon(R) Processor, 2.93GHz, 4MB Cache with 16 GB RAM, & 1 TB SSD, 10/100 Mbps Ethernet card, USB connection & internal modem, Microsoft(R) Windows(R) 10 OS Professional Enterprise, Web server software, DVD-ROM Drive (with RAM), 100/1000 Mbps NIC for Network connection and anti virus software with 32" colour graphics monitor as per Tender Specifications. Accessories included Optical Mouse, Key Pad, Laserjet colour A4 printer with the above BMS System configuration. Windows Licensed software compatible with the BMS platform etc. complete as required. | 1 | Job | 1,65,200 ₹1.7 L | 2,03,325 ₹2.0 L |
| 2.00 | SCADA Software: SITC of BMS Software. The software shall be open system architecture type which facilitates interoperability with other system. Complete functions as described in specs shall be included. The system should comply with 21 CFR Part II.
The following software packages shall have below minimum features and compliances. Software shall have minimum 2000 BACnet Data Points with 600 validated points and shall have future expansion capability at least 20%. Additional 1 Client required.
(Make:- Johnson Control-Metasys/ Siemens-Desigo/ Honeywell-EBI/ Beckhoff )
a) 3D & HD vector dynamic graphics with AutoCAD import of plan with Zoom In & Zoom Out facility
b) Native 64 Bit System, BTL (BACnet Testing Laboratories), UL (Underwriters Laboratories), EN (European Norms) Certified System, BACnet Profile B-AWS (Advanced workstation) as per the BTL Listing
c) Multi-Monitor Support-( Min 4 Nos), Multi-language support, Object tracking on multiple cameras
d) Certified OPC DA Server by OPC Foundation
e) HTML5 based Web-Server software shall permit use of Standard Web-Browsers such as Microsoft Edge, Google Chrome, Mozilla Firefox, etc
f) The Software shall comply to international standards and strive to deliver products that meet security standards such as ISA/IEC 62443, UL2900, ISO/IEC 27001, ISO/IEC62443 and OWASP (Open Web Application Security Project)
g) Cybersecurity SL2, Seamless integration of Security certificates within customer IT infrastructure, Microsoft’s active directory-based authentication, LDAP (Lightweight Directory Access Protocol) integration, Use of network infrastructure that supports physical network or VLAN segmentation, End-to-end encryption from client to server, End-to-end encryption between servers, Certificate-based data exchange, Encrypted backups
h) Audit Trail, 4-Eye Principle, Data Point Validation, Verified tempering evidence for report transmission
i) The software shall integrate with BIM data seamlessly
j) Ability to provide data to other systems thru OPC DA Server and / Or Rest web services interface
k) Reports - Customized reports for Trends and alarm with Graphic screen shots. Report facility should be inbuilt in software.
l) Seamless integration of Fire alarm system should be there
m) Alarm Escalation: Assisted treatment of alarms which helps in Predefined & fast intervention steps for faster response
n) Energy dashboards having cockpit view of total energy utilized. Energy and Power reports. | 1 | Job | 2,36,000 ₹2.4 L | 3,63,520 ₹3.6 L |
| 3.00DDC Controllers: SITC of True IP Based BTL & UL Listed for third party integration. The controller shall have 2-port Ethernet switch and WLAN interface. It should have BTL label (BACnet communications passed the BTL test) and consisting of Dual microprocessor with Storage capacity of 1 GB RAM. It should support Real Time clock with backup of upto 7 Days using super capacitor and also should have option for external battery if required. It should Support the major communication protocols: BACnet,/IP, BACnet MS/TP, Modbus IP and Modbus RTU upto 500 points. Cloud connectivity for remote access. Modbus-RTU communication should have inbuilt short circuit protection. Operating voltage AC/DC 24 V. Cybersecurity protection with BACnet Secure Connect communication as BACnet/SC node protocol. Note: 3rd party make integrator is not acceptable. Controller should be in metal enclosure with all accessories like SMPS, MCB, connectors, etc. (Make:- Johnson Control-Metasys/ Siemens-Desigo/ Honeywell-Comfort Point) | |||||
| 3.01 | DDC for Chillers, motorized valve and sensors ( 3 chillers in one) (10 -AI , 2-AO,15-DI,12-DO , 300- soft points) | 1 | Each | 6,49,000 ₹6.5 L | 1,34,564 ₹1.3 L |
| 3.02 | DDC for Primary Pump ( 3 pumps in one) (4 -AI , 2-AO, 12-DI, 5-DO ) | 1 | Each | 100 ₹100 | 96,117 ₹96,117 |
| 3.03 | DDC for Secondary Pump & sensor ( 3 pumps in one) (6 -AI, 5-AO, 15-DI, 5-DO ) | 1 | Each | 100 ₹100 | 1,04,127 ₹1.0 L |
| 3.04 | DDC for Condenser Pump (3 pumps in one) (4 -AI , 2-AO,12-DI,5-DO) | 1 | Each | 100 ₹100 | 96,117 ₹96,117 |
| 3.05 | DDC for Cooling Tower (5 -AI , 2-AO, 24-DI, 8-DO ) (3 Cooling Towers) | 1 | Each | 100 ₹100 | 1,34,564 ₹1.3 L |
| 3.06 | DDC for AHU's (8 -AI , 4-AO,12-DI, 8-DO ) | 40 | Each | 81,125 ₹32.5 L | 99,321 ₹39.7 L |
| 4.00Field Devices | |||||
Tender Value
₹3.7 Cr
EMD Value
₹7.3 L
Closing Date
2 Feb 2026, 3:00 pmClosed
Executive Engineer
Assistant Executive Engineer-in-charge, AC Division, Works Department, IIT Delhi, Hauz Khas, New Delhi - 110016
Providing, Installation, Integration and Commissioning of Building Management System for Central Air Conditioning System of LHC Building, IIT Delhi
2026_IIT_895232_1
IITD/WORKS (SP- 5235)/2026
Open Tender
Miscellaneous Works
90 days
Indian Institute of Technology Delhi
As per tender documents
16 documents required · 16 mandatory
₹0
₹7.3 L
13 Feb 2026
22 Jan 2026
3 Feb 2026
22 Jan 2026
2 Feb 2026
22 Jan 2026
Client workstation: SITC of BMS Computer System: i7 Processor or Equivalent Server PC, Intel(R) Xeon(R) Processor, 2.93GHz, 4MB Cache with 16 GB RAM, & 1 TB SSD, 10/100 Mbps Ethernet card, USB connection & internal modem, Microsoft(R) Windows(R) 10 OS Professional Enterprise, Web server software, DVD-ROM Drive (with RAM), 100/1000 Mbps NIC for Network connection and anti virus software with 32" colour graphics monitor as per Tender Specifications. Accessories included Optical Mouse, Key Pad, Laserjet colour A4 printer with the above BMS System configuration. Windows Licensed software compatible with the BMS platform etc. complete as required.
SCADA Software: SITC of BMS Software. The software shall be open system architecture type which facilitates interoperability with other system. Complete functions as described in specs shall be included. The system should comply with 21 CFR Part II. The following software packages shall have below minimum features and compliances. Software shall have minimum 2000 BACnet Data Points with 600 validated points and shall have future expansion capability at least 20%. Additional 1 Client required. (Make:- Johnson Control-Metasys/ Siemens-Desigo/ Honeywell-EBI/ Beckhoff ) a) 3D & HD vector dynamic graphics with AutoCAD import of plan with Zoom In & Zoom Out facility b) Native 64 Bit System, BTL (BACnet Testing Laboratories), UL (Underwriters Laboratories), EN (European Norms) Certified System, BACnet Profile B-AWS (Advanced workstation) as per the BTL Listing c) Multi-Monitor Support-( Min 4 Nos), Multi-language support, Object tracking on multiple cameras d) Certified OPC DA Server by OPC Foundation e) HTML5 based Web-Server software shall permit use of Standard Web-Browsers such as Microsoft Edge, Google Chrome, Mozilla Firefox, etc f) The Software shall comply to international standards and strive to deliver products that meet security standards such as ISA/IEC 62443, UL2900, ISO/IEC 27001, ISO/IEC62443 and OWASP (Open Web Application Security Project) g) Cybersecurity SL2, Seamless integration of Security certificates within customer IT infrastructure, Microsoft’s active directory-based authentication, LDAP (Lightweight Directory Access Protocol) integration, Use of network infrastructure that supports physical network or VLAN segmentation, End-to-end encryption from client to server, End-to-end encryption between servers, Certificate-based data exchange, Encrypted backups h) Audit Trail, 4-Eye Principle, Data Point Validation, Verified tempering evidence for report transmission i) The software shall integrate with BIM data seamlessly j) Ability to provide data to other systems thru OPC DA Server and / Or Rest web services interface k) Reports - Customized reports for Trends and alarm with Graphic screen shots. Report facility should be inbuilt in software. l) Seamless integration of Fire alarm system should be there m) Alarm Escalation: Assisted treatment of alarms which helps in Predefined & fast intervention steps for faster response n) Energy dashboards having cockpit view of total energy utilized. Energy and Power reports.
DDC for Chillers, motorized valve and sensors ( 3 chillers in one) (10 -AI , 2-AO,15-DI,12-DO , 300- soft points)
DDC for Primary Pump ( 3 pumps in one) (4 -AI , 2-AO, 12-DI, 5-DO )
DDC for Secondary Pump & sensor ( 3 pumps in one) (6 -AI, 5-AO, 15-DI, 5-DO )
DDC for Condenser Pump (3 pumps in one) (4 -AI , 2-AO,12-DI,5-DO)
DDC for Cooling Tower (5 -AI , 2-AO, 24-DI, 8-DO ) (3 Cooling Towers)
DDC for AHU's (8 -AI , 4-AO,12-DI, 8-DO )
SITC of Motorized Butterfly Valves & Actuators - 200 mm for Condenser Line of Chiller Plant
SITC of Motorized Butterfly Valves & Actuators - 150 mm for Evaporator Line of Chiller Plant
SITC of AHU 2 Way Modulating valve and actuator - 50 mm
SITC of AHU 2 Way Modulating valve and actuator - 65 mm
SITC of AHU 2 Way Modulating valve and actuator - 80 mm
SITC of Fresh Air Modulation Damper actuator
SITC of Supply and Return air damper on/off type actuator
SITC of Balancing Valve - 50 mm
SITC of Balancing Valve - 65 mm
SITC of Balancing Valve - 80 mm
SITC of Immersion temperature sensor 100 mm Pt1000 with Brass Thermowell
SITC of PT 1000 Duct Temperature sensor with thermowell
SITC of Duct type CO2 sensor
SITC of Ultra sonic Flow Meter ( common Chilled water header)
SITC of 2 Core, 1 Sq mm Cable, Shielded, Armoured, twisted pair cable (ISI marked)
SITC of 4 Core, 1 Sq mm Cable, Shielded, Armoured , twisted pair cable (ISI marked)
SITC of CAT 6 Cable (ISI marked)
SITC of 100 mm GI Tray
SITC of 50 mm GI Tray
Supply, installation, testing and commissioning of Layer 2 switch with 16 ports (RJ-45) including SFP modules, rack mountable, SMPS power supply & other termination accessories (Like Pigtails/LIUs/ Convertors/Splicing equipment, Patch panel, Patch Cord, etc.) complete as per specifications and as required for BMS DDC Panel Networking. The switch-to-switch distance shall not exceed beyond 80 meters. (Make: - HP / Avaya/ Tyco / Panduit / Molex)
Commissioning of the entire system and trial run for 7 days with necessary technician / engineer / manpower etc as required.
1st Year (Defect Liability Period)
Operation, Control and Monitoring
Operation, Control and Monitoring
CAMC (1 Job means for a period of 12 calendar months)
Operation, Control and Monitoring
CAMC (1 Job means for a period of 12 calendar months)
Operation, Control and Monitoring
CAMC (1 Job means for a period of 12 calendar months)
Operation, Control and Monitoring
CAMC (1 Job means for a period of 12 calendar months)
Operation, Control and Monitoring
CAMC (1 Job means for a period of 12 calendar months)
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.00 MB
BOQ_940964.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid