RequiredOEM Annual Turnover Bid to RA enabled No Note: 1. OEM Turn Over Criteria: The minimum average annual financial turnover of the OEM of the offered product during the last three years
Requiredending on 31st March of the previous financial year
Requiredshould be as indicated in the bid document. Documentary evidence in the form of certified Audited Balance Sheets of relevant periods or a certificate from the Chartered Accountant/Cost Accountant indicating the turnover details for the relevant period shall be uploaded with the bid. In case the date of constitution/incorporation of the OEM is less than 3 year old
Requiredthe average turnover in respect of the completed financial years after the date of constitution shall be taken into account for this criteria. Modular Cold Rooms ( 1 pieces ) Technical Specifications * As per GeM Category Specification 1/5 Specification Specification Name Values Bid Requirement (Allowed Values) TYPE/SIZE TEMPERATURE Application Forensic
Requiredlaboratories
RequiredH ospitality
RequiredPharmaceutic al
RequiredHoriculture
RequiredFloricultu re
RequiredSericulture
RequiredBiotechn ology
RequiredDairy and Food Processing Forensic
Requiredlaboratories
RequiredHospitality
RequiredPharmaceutical
RequiredHoriculture
RequiredFloriculture
RequiredSericulture
RequiredBiotechnology
RequiredDairy and Food Processing Type Chiller (Positive Temperature Condensing unit) Chiller (Positive Temperature Condensing unit) "Size - Outer Dimensions (feet x feet x feet)" 10x10x8 10x10x8 Maximum Ambient Temperature 45 * Cold Room set Temperature Range(Degree C) (+ 2 to + 8) (+ 2 to + 8) Tolerance on Cold Room set Temperature Range (±) 1 * RH Range 61 to 80 61 to 80 COOLING UNIT Evaporating Temperature -3 -3.0 Total Number of Cooling Units 1 * Standby units (for Redundancy) 1 1 "Nominal cooling Capacity of each unit of the Chiller @ evaporating Temp (BTU/hr) 15000 15000 "Nominal cooling Capacity of each unit of the Freezer @ evaporating Temp (BTU/hr) NA FOR CHILLER TYPE NA FOR CHILLER TYPE Type of Compressor Reciprocal Reciprocal Compressor Sealing Fully Hermetical * Number of Fans in each evaporator unit 3 * Size of Evaporator Fans 12 * Number of Fans in each Condersor unit 1 * 2/5 Size of Condensor Fans 18 * Maximum Sound level in dB - * Length of Refregirant Piping inclusive in the scope of supply Upto 10 meter Upto 10 meter CONSTRUCTION Insulation Type Poly Urethane Foam * Insulation Panel Thickness (Minimum) 60 60.0 "Density of Panels (± 2) (Kg/cubic meter)" 40 * Floor Lamination Aluminium Chequered Sheet Aluminium Chequered Sheet External Panel lamination Material Pre-Painted Galvanized Iron Sheet (PPGI) Pre-Painted Galvanized Iron Sheet (PPGI) Internal Panel lamination Material Pre-Painted Galvanized Iron Sheet (PPGI) Pre-Painted Galvanized Iron Sheet (PPGI) External Panel Sheet Thickness 0.5 * Internal Panel Sheet Thickness 0.5 * Cold Storage Door Type Swing/Hinge Door Swing/Hinge Door Number of Doors 1 * Location of the Door As per buyer's approved Drawing * Locking Mechanism Cam Lock with metallic plunger Embedded in Foam * Number of Racks/Rack Size As per buyer's approved Drawing * Number of adjustable shelfs in each Rack 4 4 Rack Material GI GI Load bearing capacity of Rack 10 10
Required25
Required50
Required75 Or higher DISPLAY/CONTROL INTERFACE Display Features LCD
RequiredBcklit LCD
RequiredLED
RequiredBacklit LED
RequiredTFT
RequiredTouch Screen Display
RequiredMonochrome Display
RequiredColour Display LCD
RequiredBcklit LCD
RequiredLED
RequiredBacklit LED
RequiredTFT
RequiredTouch Screen Display
RequiredMonochrome Display
RequiredColour Display Diplay Size 10 10.0 - 12.0 Or higher "Parameters Displayed Temperature
RequiredRH
RequiredBarom * 3/5 (Select only the Displayed parameters)" etric Pressure SALIENT FEATURES "salient Features (Select applicable features only)" Food safe and CFC free refrigerants used
RequiredMicro- processor based electronic control panel board
RequiredPower Panel with necessary accessories
RequiredNA Food safe and CFC free refrigerants used
RequiredMicro- processor based electronic control panel board
RequiredPower Panel with necessary accessories
RequiredNA POWER Power Supply Single Phase
Required230 ± 10% V AC Single Phase
Required230 ± 10% V AC Power Consumption - * INSTALLATION & COMMISSIONING Installation and Commissioning With Installation and Commissioning (inclusive in the scope of supply) * WARRANTY Warranty on Compressor Equipment 3 3
Required5
Required7 Or higher Warranty of Cold Storage Room 1 1
Required2
Required3 Or higher * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.